16.1 Maintenance of Buildings
16.1.1 Responsibility for Maintenance of Buildings
It shall be the responsibility of the owner of a building to ensure that the building is kept in good state of repair, such that its structural stability is not compromised.
16.1.2 Periodic Inspection and Maintenance Certificate
The intervals for maintenance and inspection for different types of buildings shall be as per Schedule No. 9.
Page No 127
The inspection shall be carried out by a SEOR to ascertain that the building’s structural stability has not been compromised due to lack of adequate maintenance along with a Structural Inspection Report.
It shall be the responsibility of the owner to submit the Structural Inspection Report to the Competent Authority no later than one month after the date on which inspection is due.
16.2 Maintenance of Lifts and Escalators
16.2.1 Responsibility for Maintenance of Lift and Escalators
It shall be the responsibility of the owner of a building to ensure that lifts and escalators in the building are kept in good working condition and state of repair, such that their use is safe.
16.2.2 Maintenance Protocol
1 Maintenance protocol for lifts and escalators shall be as per following Indian Standards amended from time to time.:
a) IS: 1860 – 1980 Code of Practice for Installation, Operation and Maintenance of Electric Passenger and Goods Lift
b) IS: 6620 – 1972 Code of Practice for Installation, Operation and Maintenance of Electric Service Lifts; and
c) IS: 4591 – 1968 Code of Practice for Installation and Maintenance of Escalators.
2 The lift installation should receive regular cleaning, lubrication adjustment and adequate servicing by authorized person / firm at such intervals as the type of equipment and frequency of service demand.
3 In order that the lift installation is maintained at all times in a safe condition, a proper maintenance schedule shall be drawn up in consultation with the lift manufacturer and maintenance firm / person and strictly adhered to.
4 A logbook to record all items relating to general servicing and inspection shall be maintained.
5 The electrical circuit diagram of the lift with the sequence of operation of different components and parts shall be kept readily available for reference by persons / firm responsible for the maintenance and replacement, where necessary, to the satisfaction of the Competent Authority.
6 Any accident arising out of operation of maintenance of the lifts shall be duly reported to the Competent Authority.
16.3 Maintenance of Fire Prevention and Safety Provisions
It shall be the responsibility of the owner of a building to ensure that all the fire prevention and safety provisions in a building are kept in good working condition at all times.
The fire prevention and safety provisions shall include all the fixed fire protection systems, installations, fire extinguishers, first aid kits, fire lifts and escape stairs provided in the building.
Page No 128