7.1 General Requirements
No land development /redevelopment shall be made, and/or no building shall be constructed on a plot, which comprises or includes a pit, quarry or other similar excavation or any part thereof unless such plot has been prepared or left in a manner or condition suitable for land development, redevelopment or building purposes to the satisfaction of the Authority-I.
2 No land development /redevelopment shall be made, and /or no building shall be erected on a plot liable to flood or on a slope forming an angle of more than 45° with the horizontal or on soil unsuitable for percolation or in sandy beds, unless it is proved by the owner to the satisfaction of the Authority-I that erection of such building will not be dangerous or injurious to health and the site will not be subjected to flooding or erosion or cause undue expenditure or public funds in the provisions of roads, sanitation, water supply or other public services.
3 No building or part of the building shall be allowed to be erected or re -erected and no additions or alteration to any existing building shall be allowed in the intervening spaces between the building and any overhead electric supply line.
No building or part of building shall be erected or re - erected and no addition or alteration to any existing building shall be allowed in No Development Zone declared by Integrated Island Management Plan (IIMP) for Lakshadweep Islands and its amendments from time to time.
No land development /redevelopment shall be made and or no building shall be constructed on any plot, on any part of which there is deposited refuse, excreta or other offensive matter , which in the opinion of the Authority-I is considered objectionable, until such refuse, excreta, or other offensive matter has been removed there from and the plot has been prepared or left in manner suitable for land development , redevelopment or building purposes, to the satisfaction of the Authority-I.
6 In any land designated under any legislation, for public purpose, the uses shall be permissible as per the requirements of these Bye-Laws.
The land/plot allotted to any Government or Government Autonomous body like District Panchayat, for public purpose shall be utilized for uses under 'Public Purpose' as prescribed in these Bye-Laws subject to suspension of any provision of these Bye-Laws by the Government
Subject to these Bye-Laws, the government may undertake any development without obtaining any permission under theseBye-Laws, whether of a temporary or permanent nature, that are crucial for the community's well-being and public welfare. However, they must first secure the requisite approval from the competent authority as mandated by applicable laws, orders, notifications, or circulars that may be in effect at any given time.
For Eco-Sensitive Zone / Area shall also confirm the notification published by the “Ministry of Environment and Forest”, Notification no. S.O.1067, dated,14th September 2006” and amended from time to time.
10 Residential and Industrial use shall not be allowed in the same building.
11 Land Use Zoning in Hazard Prone Areas
In natural hazard prone areas namely the earthquake prone zones as per IS:1893, the cyclone prone areas as per IS:875 Part – 3 and flood prone areas as per the Flood Atlas prepared by the Central Water Commission and/or the flood departments of the Government, the development shall be regulated to ensure special protection from hazards for any type of development irrespective of use zone. Whereas the hazard prone areas identified as per the Vulnerability Atlas of India, 1997 (hereinafter referred as Atlas) (or revisions thereof) prepared by Government of India or as may be prepared by Government from time to time shall be used for such regulations, as given in Appendix B of the Atlas. Further action for protection from these hazards is to be dealt with taking into consideration the guidelines given in Table No. 7.1 hereunder:
Page No 62
Table No.7.1: Protection of Buildings Structures and Infrastructures in Hazard Prone Areas
| A | Protection of Areas from Earthquakes(i) In those areas where there are no dangers of soil liquefaction or settlements or landslides, all building structures and infrastructures should be designed using the relevant Indian Standards as provided in the Building Regulations and the National Building Code(ii) Soils subjected to liquefaction potential under earthquake shaking, can be improved by compaction to desired relative densities, so as to prevent the possibility of liquefaction.(iii) Buildings and structures could be founded on deep bearing piles going to non-liquefiable dense layers.(iv) Steep slopes can be made more stable by terracing and construction of retaining walls and breast walls, and by ensuring good drainage of water so that the saturation of the hill-slope is avoided.(v) Any other appropriate engineering intervention to save the building structures or infrastructure from the fury of the earthquake. |
| Note:The protective action given under (ii) to (v) in this table, will usually involve large amount of costs and should only be considered in the case of large and costly structures. For ordinary buildings the cost of improvement of the site will usually be uneconomical, hence bad sites should be excluded by Land Use Zoning. | |
| B | Protection from Cyclonic Wind Damagei) Buildings, structures, and infrastructures in the cyclone prone areas should be designed according to the Indian Standards and Guidelines as provided in the Regulations and the latest National Building Code.ii) Light utility structures used for electrical transmission and distribution, and towers for communications, chimneystacks of industrial structures require special design considerations against the cyclonic wind pressures, suctions, and uplifts.iii) In case the buildings, structures and infrastructures are founded on marine clay deposits it will be advisable to adopt either under-reamed piled foundations, or individual column footing with a reinforced concrete beam located at the level of the ground, or a continuous reinforced concrete strip footing.iv) Wherever, the topsoil could become slushy due to flooding, the top layer of 30 cm depth of soil should not be considered for providing lateral stability.v) In storm surge prone areas, it will be preferable to construct the community structures, like schools, cyclone shelters, etc. by raising the level of the ground protected by provision of retaining walls at sufficient distance away from the building, taken to such depth that no erosion takes place due to receding storm surge. Alternatively, construct the community structures on stilts with no masonry or bracing up to the probable maximum surge level. |
12 In case of mixed-use buildings with residential and permissible non-residential uses, either on the ground floor or any other floors, they shall be provided with separate means of access / staircase.
Page No 63