1. Background
1.1. Urbanization has led to horizontal growth of the cities thus creating problems of urban sprawl. This has resulted in increase in trip lengths and higher usage of private vehicles, problems of pollution, and increased demand for infrastructure. To address these issues, many cities have strengthened their public transport by developing mass rapid transit systems (MRTS) such as metro rails and Bus Rapid Transit Systems (BRTS). It is, however, important to efficiently use these systems by integrating the land use with the transport infrastructure to make the cities liveable, healthy and smart.
2. Transit Oriented Development (TOD)
2.1. Transit Oriented Development is essentially any development, macro or micro that is focused on the integration of land use and transport planning and aims to develop planned sustainable urban growth centres, having walkable and liveable communes with high density mixed land-use. Citizens have access to open green and public spaces and at the same time transit facilities are efficiently utilised.
2.2. TOD increases the accessibility of the transit stations by creating pedestrian and Non-Motorised Transport (NMT) friendly infrastructure that benefits large number of people, thereby increasing the ridership of the transit facility and improving the economic and financial viability of the system. Since the transit corridor has mixed land-use, where the transit stations are either origin (housing) or destination (work), the corridor experiencing peak hour traffic in both directions would optimize the use of the transit system.
2.3. The primary goals of TOD are to -
(iii) Reduce/discourage private vehicle dependency and induce public transport use – through design, policy measures and enforcement.
(iv) Provide easy public transport access to maximum number of people within walking distance – through densification and enhanced connectivity.
3. TOD Zones
3.1. In order to ensure optimum utilization of scarce land resources and to provide opportunities for restructuring through Mixed Land-use along the Mass Transit corridors, Transit oriented Development (TOD) will be allowed. TOD Zones will be the area in immediate vicinity of the mass transit stations, i.e. within a walking distance and also well integrated with bicycle, feeder and transit networks. TOD Zones shall be demarcated in the Master Plan describing overall objective, Land-use and Transport strategy, provisions, and incentives for promotion of TOD.
3.2. The TOD Zone designated up to 800 meters in and around the MRTS, BRTS or Transit Stationsis proposed. It is to be clarified that in general 800 meters will be calculated from the boundaries of the MRTS or BRTS stations. For transit corridors along MRTS or BRTS, TOD zones shall be designated as 100-200 meters on either side of the corridors, barring restricted areas as per provisions of Master Plan.
3.3. In areas, where there are no MRTS or BRTS corridors or stations exists, the TOD Zones shall be designated as 100 -200 meters on either side of the Bus Transit System/ Transit Corridors as demarcated in the Master Plan based on physical condition, trend of development, availability of land.
4. High Density Compact Development
4.1. TOD promotes densification in the influence area by providing higher Floor Area Ratio (FLOOR AREA RATIO (FAR)) to support higher population and job density as compared to the area around and beyond the TOD Zone. FLOOR AREA RATIO (FAR) in the TOD zone in transit corridors along MRTS or BRTS or other public transit corridors, and nodes, as mentioned above shall be additional 40% on the maximum permissible FLOOR AREA RATIO (FAR) of the zone/plot, subject to a capping of maximum FLOOR AREA RATIO (FAR) of 400, including all. However maximum FLOOR AREA RATIO (FAR) in all the TOD zones shall not exceed 400. This will promote higher concentration of people within the walking distances of transit station, thereby increasing the
ridership of the public transport and resulting in increased Floor Area Ratio (FAR)e revenue, pollution and congestion reduction.
Detailed calculation of additional FLOOR AREA RATIO (FAR) and break-up of maximum FLOOR AREA RATIO (FAR) allowed against different uses and other details are given below:
Let,
For Transit Zone –
5. Diversity
5.1. TOD zone shall be designated as mixed-use zone. Transit stations shall be classified based on typologies and mix of land-use that optimises level of density shall be encouraged. The land use such as mixed land-use, affordable housing, employment nodes and recreational facilities/malls shall be encouraged to support TOD. The land-use such as low density housing, free parking and surface/multi-level parking, petrol pumps/CNG stations, automobile garages, warehouses and cremation grounds that does not support TOD shall be discouraged.
5.2. Mixed land-use integrated development shall be promoted for plot area more than 2000 sq. m. (with combination of housing for various income strata, commercial development, road and other infrastructure). In such developments, maximum 50% shall be allocated for Non-Residential (Commercial, Public and Semi Public and Institutional), and 50% as per existing zoning. In any zone, minimum 30% shall be reserved for residential purpose. Charges for premium FLOOR AREA RATIO (FAR) shall be exempted for affordable housing projects.
5.3. The mixed-use development has to mandatorily incorporate affordable housing and open spaces/circulation areas. In order to promote affordable housing, out of the 30% of residential use, a minimum of 30% of the built-up area shall be utilized for EWS and LIG housingup to 66 sq. m. built-up area in the TOD Zones.
5.4. Open space is critical to offset the impact of dense mixed-use developments and improve the environment and quality of life. Regulations may be framed to mandate the developer to allocate at least 10% of the land abutting the road for plot sizes more than 2500 sq.m. for the development of parks or open public spaces that are accessible to the general public subject to fulfilling the provision at SI. No. 4.4 whichever is more.
6. Destination Accessibility
6.1. In order to improve the destination accessibility, roads along the mass transit corridors and other public transport corridors shall have a minimum ROW of 24 m. At least one road on each side of the station which acts as a feeder road shall have a minimum ROW of 10m. The alignment, ROW and influence zones for Bus Rapid Transit System, Metro Rail Transit System and Bus Transit System shall be marked in each Master Plan of a Town. In TOD influence zones “Urban Design Layouts” shall be prepared.
6.2. High frequency feeder services in terms of regular buses, mini buses, mini vans shall be provided by transit agencies depending upon the commuter demand.
6.3. “Park and Ride” facilities shall be developed within station area for all the transit stations. Larger park and ride facilities shall be developed at terminal stations as well as stations at outskirts where availability of land is not a major constraint. Concessional parking rates for bicycle parking shall be adopted to promote the use of bicycles as an access mode to transit.
6.4. Direct walking paths to be provided to transit stations without any detour e.g. walking paths through parks, and exclusive skywalks from major trip generators such as malls.
7. Demand Management
7.1. There is a need to increase the supply of paid off-street parking facilities at strategic locations to contain the tendency of on-street parking. Shared parking shall be developed at depots, terminals and multi-modal hubs etc. Parking norms as per the existing building bye laws shall apply.
7.2. Regulation of hawkers is important to reduce the encroachments which obstruct the free flow of pedestrian and vehicular traffic through demarcation of hawker zones into red zone where hawkers are not permitted at all times, amber zone where hawkers are permitted during certain period of time. and green zone where hawkers are permitted all the time. The ULB shall issue the licenses with small fees to regulate the number of hawkers.
8. Applicability, Fee and Charges
8.1. Additional constructions shall be allowed on under-construction buildings but not on completed existing buildings, with the additional FLOOR AREA RATIO (FAR) under this policy. In such a case, the parking norms will have to be fulfilled. Such benefits on under-construction developments shall be allowed only after production of a structural stability certificate of the proposed constructions from Civil Engineering Departments of IIT/NIT/Government
Engineering colleges. The additional floor allowed in such buildingshall be limited to one additional storey.
8.2.The Setbacks of the building – the existing setbacks including front setback may be allowed for higher floor/floorsand necessary relaxation to that extent may be granted by the Authority subject to compliance of all fire requirements and fire NOCs. In any case existing approved setbacks shall not be reduced.
8.3.The identification of any new corridors shall be done by the competent authority and the State Government will approve the corridor on the recommendation of the Guwahati Metropolitan Development Authority (GMDA) and the provisions of this policy shall be applicable to such areas.
8.4. All the fees and charges collected shall be in the form of 'Infrastructure Augmentation Charges' and to be kept in the separate head of account as 'Infrastructure Development Fund' (IDF) and the same shall be exclusively considered for development of TOD Zones and implementation of Transit System Projects. The Authority may work out own formula for charging cost of providinghigher FLOORAREA RATIO(FAR) withapproval of theState Government.
Sd/-
Chief Executive Officer, Guwahati Metropolitan Development Authority Bhangagarh, Guwahati-5.
Abbreviation
| CCTV | Close Circuit Television |
| CTI | Common Telecommunication Infrastructure |
| DoT | Department of Telecommunication |
| FTTx | Fiber to the X Fiber |
| Fiber To The Home (FTTH) | |
| Fiber To The Premises (FTTP) | |
| Fiber To The Building (FTTB) | |
| Fiber To The Node (FTTN) | |
| Fiber To The Curb/Cabinet (FTTC) | |
| GDP | Gross Domestic Product |
| IBS | In Building Solutions |
| ISP | Internet Service Provider |
| MBIT | Megabit |
| OFC | Optic Fiber Communication |
| QoS | Quality of Service |
| RWA | Residential WelFloor Area Ratio (FAR)e Association |
| TRAI | Telecom Regulatory Authority of India |
| TSP | Telecommunication Service Provider |
KAVITHA PADMANABHAN, Commissioner & Secretary to the Govt. of Assam, Department of Housing & Urban Affairs.
Guwahati : Printed and Published by the Director, Directorate of Printing & Stationery, Assam, Guwahati-21. Extraordinary Gazette No. 1375 - 100 + 10 - 15 - 10 - 2022. (visit at– dpns.assam.gov.in)