- The form of application shall be in Form-1 (Part-II).
42. Standards for Buildings.—
Foundation and Structural design:—
(a) The structural design of foundation, elements made by masonry, timbers, plain concrete, reinforced concrete, pre-stress concrete and structural steel shall be carried out in accordance with the prevailing B.I.S. code of practice taking into consideration the seismic load required to be taken for this region;
(b) Quality of material and workmanship:—
All materials and workmanship shall be of good quality conforming generally to accepted standards of A.P.W.D. and Bureau of Indian Standard specification and codes as included in N.B.C. of India;
(c) Damp proof course: - All walls internal or external shall be provided with an efficient damp proof course not less than 150 mm above ground level.
- No piece of land shall be used as a site for the construction of a building if-
(a) the Authority considers that site is insanitary or that it is dangerous to construct a building on it;
(b) if any plot is situated in already developed areas, and the means of access is less than the minimum prescribed width, the Authority may consider the proposal with 75FLOOR AREA RATIO (FAR).
44. Means of access.—
(i) No building shall be erected so as to deprive any other building of the means of access;
(ii) Every person who erects a building shall not at any time erect or cause or permit to erect or re-erect any building which in any way encroaches upon and diminishes area set apart as means of access;
(iii) The Authority may refuse or modify a proposal if it considers that site is insanitary or that it is dangerous to construct a building on it or if by virtue of smallness or odd shape of the site if the Authority considers that it is not suitable for development or if the site is near a water body or water course and the proposed development is likely to contaminate the said water body or water course or change the course of the channel or if the site is likely to be inundated and satisfactory arrangements for proper drainage is not possible or if the site is a filled up tank or low lying or made up of soil by depositing rubbish or offensive matters the proposal is likely to be effected by dampness owing to the sub soil water or if the site does not abut any existing public or private street;
(iv) The width of the main street in which the building abuts shall not be less than as given below and the width of road shall be taken as existing available road width or the road width in the revenue record whichever is less:—
| Sl | Type of Building/Use | Minimum Road Width required | Minimum Road Width required |
| Sl | Type of Building/Use | Urban Local Bodies (ULB) Area | Outside Urban Local Bodies (ULB) area but within Master Plan |
| 1 | Multistoryed commercial / Multistoryed mixed use | - 15.0 m | - 18.0 m |
| 2 | Institutional* | - | - |
| 3 | Educational Facilities(A) Schools: Primary, Higher Secondary(B) Higher Education | - 9.0 m- 12.0 m | - 12.0 m- 18.0 m |
| 4 | Health Facilities(A) Clinics(B) Hospital/ Nursing Home (up to 20 beds) (C) Hospital/ Nursing Home (>20 beds) | - 9.0 m- 12.0 m- 15.0 m | - 12.0 m- 15.0 m- 18.0 m |
| 5 | Hall for social gathering/assembly hall(A) Community Hall (up to 2000 Sq.m. plot)(B) Community Hall (>2000 Sq.m. plot)(This shall not be applicable for Restaurant, Gymnasium, clubhouse, Library for which minimum road width of 6.60 Mt shall be required) | -9.0 m-12.0 m | -12.0 m-15.0 m |
| 6 | Industrial / Warehouse etc and similar use | -12.0 m | -15.0 m |
* For other institutional uses not specified above the road width will be as prescribed above for similar nature of uses.