108. Cinemas,-Theatres-and-Assembly-Halls.—
In addition to any other Byelaws applicable to such buildings, the following shall apply:—
(a) If any portion of the cinema, theatre or assembly hall (except accommodation for caretakers and his family) is intended to be used as a domestic building such portion shall comply with all the requirements of a domestic building;
(b) Every room in such building as mentioned above shall be lighted and ventilated by doors, ventilators and windows abutting on an interior or exterior open air space which shall not be less than 1/5 of the total floor area:
Provided that if exhaust fans are installed or if it is air conditioned, the requirement of this clause shall be suitably relaxed by the Authority;
(c) Gangways and passages must not be more than 6.0 m apart. No seat must be more than 3.0 m from gangway or passage;
(d) A gangway or passage must be at least 1.2 m wide and they shall be provided at least one in the center and one on each side;
(e) The height of the bottom balcony or the gallery shall not be less than 3.0 m from the floor of the auditorium and depth under the balcony shall not be more than 3 times the clear height. The clear distance between the backs of two successive rows shall not be less than 0.9 m, but for seats with rocking backs it may be 0.8 m;
(f) The maximum slope of the floor of the auditorium shall not be more than 1 in 20;
(g) The maximum width of the balcony steps shall be 0.8 m. Provided that for the front, and rear step, this distance is 0.9 m;
(h) The maximum rise of the balcony steps shall be 0.4 m;
(i) The maximum height of the roof or ceiling at the highest step of the balcony shall be 3.0 m and at no place the distance between the nosing and lowest projection ray shall be less than 2.4 m;
(j) In the case of the cinema the Floor Area Ratio (FAR)thest seat shall not be more than 45.0 m anyway from the screen;
(k) The angle of seating shall not be less than 60 degree and the front row shall not be nearer to the screen than the half of its width;
(1) The position and height of the screen be regulated in such a way that the maximum angle of the line of vision from the front seat to the top of the screen shall not exceed 35 degrees;
(m) No corridor leading to any stair case or exit passage shall be less than 2.0 m. in width;
(n) No corridor shall be used for any purpose other than the exit and entrance from the auditorium;
(o) Doors: Entrance and exit doors shall be provided at a rate of not less than one door of a dimension of 2.0 m in width and 2.4 m in height for every 200 individuals or part thereof;
(p) All out doors for the use of the public be made open outward and in such a manner that when open they shall not obstruct any gangway or passage or stairway or landing;
(q) Staircase: - The access to the auditorium if it is on the upper storey or the galleries shall be provided by not less than two independent stairs of fire-proof-construction. Such stairs at no place shall be less than 2.0 m clear in width;
(r) No staircase shall have a flight of more than 15 steps or less than 3 steps and width of the landing between such flight shall be the same width of the staircase. The tread of the step shall not be less than 150 mm. and rise not more than 300 mm.;
(s) No space less than 2.4 m in height shall be allowed in between two intermediate floors of the auditorium;
(t) The cinematograph machine room shall be substantially constructed of fire resisting material or lined with such material.
109. Factories and building of the warehouse class.—
(a) Factories: - Every room in such building shall be lighted and ventilated by sufficient number of windows, ventilators and skylight exclusive of doors having clear opening not less 1/15 of the floor area abutting on open air space of width not less than 1/3 rd the height of the part of the building-abutting-such-open-space; provided that this requirement may be relaxed if artificial lighting and ventilation are installed to the satisfaction of the Authority;
(b) Height of the floors: - The height of the ground floor and each of the upper floors shall not be less than 4.2m and 3.9 m. respectively and the height of the cellar or basement shall in no part be less than 2.4 m., provided that these provisions shall not apply to the extensions of the ground floor and upper floors of the existing building.
110. Special regulations for construction in hilly areas.—
(a) The Authority shall ask for detailed topographic survey map of the site, showing the proposed ground levels of the plot and the remedial construction measures to check the undesired erosion that may affect the adjoining areas. The Authority may also give special direction for framing the proposal in such a way which involves least disturbance to the natural terrain and keeping of bare land which is not allowed.
(b) If terrace cutting is done for building constructed on hill the depth and slope of the cut should be restricted according to the soil characteristic of the area.
(c) Adequate drainage provision should be kept to the satisfaction of the Authority so that rain water and waste water can drain out from the plot without causing soil erosion.
(d) In hilly areas with slope greater than 10⁰ special protection measures shall have to be provided as specified by the Authority. Local ground conditions shall be taken into account in the determination of the appropriate precautionary work and protection walls as well as relevant code of I.S. as specified in Chapter-V.
(e) The maximum height of cutting for development should generally be 4 m. to 6m and cutting of slope over a height of 6m. shall not be ordinarily permitted. Height of 6m earth cutting should be from face of 1 st cutting.
(f) Detailed scheme and design to be submitted by owner for development of individual plot including earth work calculation (cutting and filling) and slope
stability analysis calculation, remedial measures etc. and the same is to be vetted by an approved third party.
(g) Rain water harvesting by roof water collection system shall be made mandatory in hilly areas.
(h) Provision of dry sump (including design calculation) in all individual plots, capable of holding rain water during peak monsoon.
(i) Provision of silt fence along plot boundary to prevent soil wasting into another's plot or into a common drainage network, shall be made mandatory.
(j) If however Authority feels that special protective measures are required in the plot prior to any construction in the plot, no construction of building shall be allowed by the Authority in such plot unless the protective measures are completed as directed by the Authority first.
(k) A minimum 30% of land in a plot in hilly areas required to be covered under vegetation.
111. Environmental-aspects-and-landscaping.—
The Authority may impose special provision for landscaping, in special type of building/ plot that is nature and number of plantation to be carried out, maintenance of vegetable cover in the plot for the environmental up gradation of the area and to restrict soil erosion. In every plot at least 20% of the land should be utilized for tree plantation and greenery which may be reduced to 10% in case of housing projects where minimum 25% of the FLOOR AREA RATIO (FAR) area is dedicated to Affordable Housing.
- (a) The authorities may impose conditions to the developerto develop the roads and drains upto the road and drain abutting the plot.;
(b) If however, the developer agrees to contribute towards the development charge for developing adjoining roads and drains or decides to relinquish a part of these land for improvement of road, drain or creation of open space for the locality without asking for any compensation to the satisfaction of the Authority, the Authority shall consider allowing additional proportionate FLOOR AREA RATIO (FAR) in that particular plot development of the area.
-
In Group Housing project and projects where a number of apartment blocks are proposed in a single plot the Authority shall impose special regulations for drains, recreational open space, garbage collection etc. in addition to the regulations contained in these Bye-laws. Both
-
Every building shall provide one or more rainwater harvesting structures to collect the roof top run-off. The total dimension of recharging/percolating pits/trenches should be at least 5 cubic metres dimension for every 100 sq. metres. of roof area, provided that such rain water harvesting structure shall also be provided in cases of all apartment houses, institutional and similar buildings and buildings in hilly areas as per Appendix-VI.
115. (a) RE-USE OF RECYCLED / WASTEWATER.—
Every group housing scheme/apartment houses and commercial complexes/institutional buildings shall be provided with installation of system of recycling of wastewater from bathrooms and kitchen sinks (excluding water closets). The final treatment plant should recycle water which should be re-used for purposes other than drinking such as gardening, landscaping, and washing of roads/pathways and so on. Accordingly the space for a wastewater treatment plant is mandatory to be proposed in the layout and constructed as per the approved norms and specifications in case of,-
i. residential layouts, areas measuring 4000 Sqm or more;
ii. group housing / Apartment houses if the area measures 2000 Sqm and above or if the consumption of water is 20000 liters per day or if it is a multi-storied building with 20 or more apartments houses;
iii. commercial Complexes / Institutional / Hotel and Lodges/Industrial Buildings etc. if the built-up area is 1500 Sqm and more or water consumption is 20,000 liters per day;
iv. hospitals/Nursing Homes with 40 or more beds.