Registered Structural Engineer on Record (SER) or Structural Design Agency on Record (SDAR) shall give a certificate of structural safety of design as per proforma given in Form-19 and Form-21 at the time of completion.
Buildings with Soft Storey:
In case buildings with a flexible storey, such as the ground storey consisting of open spaces for parking, Stilt buildings or any other storey with open halls, special arrangements are to be made to increase the lateral strength and stiffness of the soft/open storey such as Steel bracing / Shear walls / Brick infill between columns. Dynamic analysis of building is to be carried out including the strength and stiffness effects of infill and inelastic deformations in the members, particularly, those in the soft storey, and the structural members are to be designed accordingly.
Alternatively, the following design criteria are to be adopted after carrying out the earthquake analysis, neglecting the effect of infill walls in other storeys:
(a) The columns and beams of the soft storey shall be designed for 2.5 times the storey shears and moments, calculated under seismic loads specified in the other relevant clauses; or,
(b) Besides the columns designed and detailed for the calculated storey shears and moments, shear walls shall be placed symmetrically in both directions of the building as Floor Area Ratio (FAR) away from the centre of the building as feasible; to be designed exclusively for 1.5 times the lateral storey shear force calculated as before.
For details of design and provisions, IS 1893, Part 1 shall be referred."
(f) Constructional Safety
(i) Supervision
All construction except RCC load bearing buildings up to 3 storeys shall be carried out under supervision of the Construction Engineer on Record (CER) or Construction Management Agency on Record (CMAR) for various seismic zones.
(ii) Certification of structural safety in construction
CER/ CMAR shall give a certificate of structural safety of construction as per proforma given in Form-18 at the time of completion.
(g) Quality Control and Inspection
(i) Inspection
All the construction for highrise buildings higher than seven storeys, public buildings and special structures shall be carried out under quality inspection program prepared and implemented under the Quality Auditor on Record (QAR) or Quality Auditor Agency on Record (QAAR) in seismic zone V.