Part IVGeneral Building Requriements – Setback, Marginal Distance, Height and FSI
15.0 General
Following regulations for core area shall be applicable for the lands included in core area as shown on the Development Plan. For the areas outside core area in the Development Plan, regulation for non-core area shall apply. However, in Core area, if the original land holding is more than 0.40 Hect., then regulations of non-core area shall apply.
15.1Regulations for Core Area
15.1.1 Residential Buildings
(a) Floor Space Index.
Maximum permissible FSI shall be 2.20 for purely residential, commercial or mixed use buildings. In addition to this premium FSI of 0.30 and TDR of 0.30 shall be permissible.
(b) Setback (Road side margin/s) - The minimum front setback from the existing or proposed road/roads shall be as under:-
Sr. No.
Road width
For Purely Residential
For commercial or mixed Users
(i)
For streets more than 4.5 but upto 6.0 m. in width.
1.00 m.
2.00 m.
(ii)
For streets above 6 m.
1.50 m
2.50 m.2.00m.
(iii)
For streets below 12 m.
1.50 m.
2.00 m.
(iv)
For streets 12 m. and above.
1.50 m.
3.00 m.
(v)
For streets 18 m. and above.
2.00 m.
4.50 m.
(c) Side & rear marginal distances - Side & rear marginal distances for construction in a plot shall be as below
Residential Plot Area
Side
Rear
Upto 250 sq. m
0.00
0.00
Above 250 &upto 500 sq. m
1.00 m.
1.00 m.
Above 500 sq. m. &upto 1000 sq.m
2.00 m.
2.00 m.
Above 1000 sq.m.
As per Regulation no.15.6.a
NOTE :- For light and ventilation, provisions in Regulation no.15.11 shall apply.
d) For streets less than 4.5 m. in width, no setback shall be prescribed subject to condition that no lane shall be less than 4.5 m. in width clear of structural projection. For lanes less than 4.5 m. in width, a setback of 2.25 m. shall be prescribed from the centre line of such lane. Streets less than 4.5 m. shall be treated as lanes only when they serve as access to the properties fronting on them.
e) Above set back and marginal distances shall be applicable for buildings with ground + 23storey or parking + 34storey structures. For buildings having height more than this but less than 15 mtr., marginal distances shall be increased by 1 mtr. For buildings having height more than this, marginal distances shall be as per regulations of non-core area.
f) Structural projections such as balconies, cornices, weather sheds, roof projections etc. shall be allowed in the setback distance prescribed above as per Regulation no. 15.8.
g) Height- The height of the building shall be governed by Regulation no. 15.9.
h) <s>Ground Coverage-The maximum ground coverage shall be 2/3 of the plot area</s> Steps may be allowed within marginal distance.
i) Parking – parking shall be provided as per the provisions in Regulation no.20.0.
15.1.2 Public semipublic, Educational, Medical, Institutional, Mercantile, and Other Buildings
(a) Floor Space Index - Maximum FSI permissible <s>for public semipublic buildings</s> shall be 2.5and <s>for remaining buildings it shall be 2.2.</s> In addition to this premium FSI of 0.30 and TDR of 0.30 shall be permissible. The owner shall have option of availing TDR instead of premium FSI.
(b) Marginal Distance - For these buildings marginal distances shall be 3 m. on all sides.
(c)For buildings having height more than 15 m. regulations of outside core area shall apply for front, side and rear marginal distances.
Provided that for buildings like cinema theatre, multiplex, assembly buildings, shopping malls, regulation of outside core area, except FSI, shall apply.
15.1.3 Pathway for access to the internal building or interior part of the building shall not be less than 3.6m. (12 ft) in width.
15.1.4 If the width of property is less than 3.6 m. (12 ft), the entire ground floor shall be on stilts.
15.1.5 Front setback (marginal distances) as prescribed by the Highway or any other rules shall be applicable if they are over and above as prescribed in these regulations.
15.2Regualtions for Outside Core Area.
15.2.1 Residential Buildings
The provisions as given in Table 7 shall apply for the residential buildings, mix use building permissible in areas outside core areas and residential buildings permissible in industrial areas.
Table No. 7 PLOT SIZE/WIDTH OF PLOT/MARGINS/HEIGHTS AND FSI FOR BUILDINGS IN RESIDENTIAL ZONE IN NON-CORE AERA
Table No. 7 PLOT SIZE/WIDTH OF PLOT/MARGINS/HEIGHTS AND FSI FOR BUILDINGS IN RESIDENTIAL ZONE IN NON-CORE AERA
Table No. 7 PLOT SIZE/WIDTH OF PLOT/MARGINS/HEIGHTS AND FSI FOR BUILDINGS IN RESIDENTIAL ZONE IN NON-CORE AERA
Table No. 7 PLOT SIZE/WIDTH OF PLOT/MARGINS/HEIGHTS AND FSI FOR BUILDINGS IN RESIDENTIAL ZONE IN NON-CORE AERA
Table No. 7 PLOT SIZE/WIDTH OF PLOT/MARGINS/HEIGHTS AND FSI FOR BUILDINGS IN RESIDENTIAL ZONE IN NON-CORE AERA
Table No. 7 PLOT SIZE/WIDTH OF PLOT/MARGINS/HEIGHTS AND FSI FOR BUILDINGS IN RESIDENTIAL ZONE IN NON-CORE AERA
Table No. 7 PLOT SIZE/WIDTH OF PLOT/MARGINS/HEIGHTS AND FSI FOR BUILDINGS IN RESIDENTIAL ZONE IN NON-CORE AERA
Table No. 7 PLOT SIZE/WIDTH OF PLOT/MARGINS/HEIGHTS AND FSI FOR BUILDINGS IN RESIDENTIAL ZONE IN NON-CORE AERA
Table No. 7 PLOT SIZE/WIDTH OF PLOT/MARGINS/HEIGHTS AND FSI FOR BUILDINGS IN RESIDENTIAL ZONE IN NON-CORE AERA
Table No. 7 PLOT SIZE/WIDTH OF PLOT/MARGINS/HEIGHTS AND FSI FOR BUILDINGS IN RESIDENTIAL ZONE IN NON-CORE AERA
Table No. 7 PLOT SIZE/WIDTH OF PLOT/MARGINS/HEIGHTS AND FSI FOR BUILDINGS IN RESIDENTIAL ZONE IN NON-CORE AERA
S No
Description of Road / housing pattern
Minimum Required
Minimum Required
Minimum Required
Minimum Required
Minimum Required
Basic FSI
Premium FSI
Fun-gible FSI
Remarks
S No
Description of Road / housing pattern
Plot Size
Width Of Plot
Set Back from road front
Side marginal distance
Rear marginal distance
Basic FSI
Premium FSI
Fun-gible FSI
Remarks
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(9)
(10)
1.
National/ State Highway
450
15
6.0 m. from road line or as specified by Highway rules, whichever is more.
3.0
3.0
1.20
0.30
0.30
2.
M.D.R./ O.D.R.
450
15
6.0 m. from road line or as specified by Highwayrules whichever is more
3.0
3.0
1.20
0.30
0.30
3.
Other roads 24 m. wide and above
300
12
6.0 m.
3.0
3.0
1.20
0.30
0.30
4.
Roads of width below 24m. wide and up to 18m.
250
12
4.5m.
3.00
3.00
1.10
0.30
0.30
5.
Roads of width below 18m. wide and up to 15m.
250
10
4.5m.
2.25
2.25
1.00
0.30
0.30
Margins only for G + 2 or stilt + 2 structure
6.
Road of width below 15 m. and above 9 m.
150
8
3.0 m
2.25
2.25
1.00
0.30
0.30
Margins only for G + 2 or stilt + 2 structure
7.
Road of width upto9 m.
100
7
3.0 m.
1.5
1.5
1.00
0.30
0.3 for 6 m. and above road
Margins only for G + 1 or stilt + 1 structure
8.
Row housing on roads of width 12m. and below
30 to 125
3.50
2.25 m.
0.00(in case of corner plot, 1.5 or building line of the adjoining road whichever is more)
1.5
1.00
0.30
-do-
Margins only for G+1 or Stilt+1 structure
9.
Row housing for L.I.G. EWS/High Density Housing, Slum Up-gradation etc. by public authority
20 to50
3.00
0.90 m. from pathway 2.25 m. from road boundary
-do-
0.90
1.00
0.30
--
Only G+1 or Stilt+1 structure.
10.
36 m. wide D. P. Road from Gangapur S. No. 12 to Ambad S. No. 199 .
300
12
3.00(for commercial use also)
3.00
3.00
1.20
0.30
0.30
11.
30 m. wide D.P. road along canal in Dasak shivar.
250
10
4.5m.
2.25
2.25
1.00
0.30
0.30
Margins only for G + 2 or stilt + 2 structure
15.6Requirements of Marginal Distances
(a) Side or rear marginal distance in relation to the height of the building for light and ventilations:
The marginal distance on all sides shall be as per Table No.7 for building height mentioned therein. For height more than specified in the said table, the marginal distance on all sides except the front side of a building shall be minimum H/4 ( Where H = Height of the building above ground level) subject to a minimum of 3.0 m. for residential building, 4.5 m. for commercial building and 6.0 m. for special building mentioned in Regulation no. 6.2.6.1
Provided that such marginal distance shall be subject to maximum of 16.0 m. Such marginal distance over and above 6.0 m. (on ground) may be allowed to be left on upper floor/s to achieve required marginal distance (stepped marginal distances).
(b) Front margin – Front margin shall be as per Regulation no.15.2.1 or as given below with reference to height of building.
i)
Height above 18 m. & upto 24 m.
6.00 m.
ii)
Height above 24 m. & upto 36 m.
7.50 m.
iii)
Height above 36 m. & upto 48 m.
9.00 m.
iv)
Height above 48 m. & upto 60 m.
12.00 m.
v)
Height above 60 m.
15.00 m.
Provided that, in case of group housing scheme where building abuts on internal road, the minimum 3.0 m. set back from internal road or distance between two buildings whichever is more shall be provided. For Development plan road or classified road or through road, passing through Group Housing Scheme, the setback as prescribed in the regulations shall be provided.
(c) Distance between two buildings- The distance between two buildings shall be the side marginal distance required for the higher building between two adjoining buildings.
15.7 Buildings Abutting Two or More Streets
When a Building abuts two or more streets, the setbacks from the streets shall be such as if the building is fronting on each such street.
15.3Charges for Premium and Fungible FSI
The premium FSI and fungible FSI mentioned in above regulations shall be available on payment of charges to the Corporation as mentioned below at the rate of land mentioned in ASR prepared by Inspector General of Registration, Maharashtra State for the respective year.
Charges for Premium FSI
10% of land rate for all uses.
Charges for Fungible FSI
40% of land rate for all uses.
The Municipal Commissioner shall deposit the amount collected through the aforesaid premium in the development fund set up under section 124J of Maharashtra Regional and Town Planning Act, 1966 and shall utilise the same for up-gradation of infrastructure in the area on priority as well as implementation of Development Plan proposals and creation of civic amenities.
15.4Maximum Permissible FSI / TDR on a Plot
In case of plots located outside core area, the maximum permissible FSI including basic FSI, in-situ FSI, Premium FSI, Fungible FSI, TDR admissible under these regulations taken together shall not exceed the limit given below
Provided that, the maximum permissible limits of FSI specified above, may allowed to be exceeded in cases mentioned in chapter VIII where additional FSI is permissible over above limit. i.e. (basic + additional FSI permissible under the said chapter) – limits specified above, shall be the additional limit, if any, in such cases.
Provided further that, the maximum limits of FSI prescribed above shall be applicable to fresh permission and also to an existing building which has not been granted full occupation certificate but subject to production of stability certificate from structural engineer in respect of such existing building. However, in no case the rights of the flat owner / unit holders shall be adversely affected.
Provided further that above limits of FSI shall be exclusive of the FSI required for Inclusive housing as per Regulation no. 13.7
Provided further that the restrictions of road width mentioned above shall not be applicable in cases where, the permissible FSI is more than the basic FSI in various schemes such as, slum rehabilitation scheme, redevelopment of dangerous buildings, cluster development for core area, redevelopment of MHADA buildings etc.
15.5 FSI of Green Belt
FSI of the green belt zone shown on the development plan may be allowed on remaining land of the owner by counting area of green belt in gross area of plot subject to condition that owner shall develop cycle track and plant trees in this area with proper planning at the rate of minimum 100 trees per hector and should have been survived for atleast one year prior to issuance of occupation certificate.
Provided that, this shall not be in toto applicable where this green belt area is included in recreational open space to be left as per Regulation no.13.3.6