15.1.1 Residential Buildings
(a) Floor Space Index.
Maximum permissible FSI shall be 2.20 for purely residential, commercial or mixed use buildings. In addition to this premium FSI of 0.30 and TDR of 0.30 shall be permissible.
(b) Setback (Road side margin/s) - The minimum front setback from the existing or proposed road/roads shall be as under:-
| Sr. No. | Road width | For Purely Residential | For commercial or mixed Users |
|---|---|---|---|
| (i) | For streets more than 4.5 but upto 6.0 m. in width. | 1.00 m. | 2.00 m. |
| (ii) | For streets above 6 m. | 1.50 m | 2.50 m.2.00m. |
| (iii) | For streets below 12 m. | 1.50 m. | 2.00 m. |
| (iv) | For streets 12 m. and above. | 1.50 m. | 3.00 m. |
| (v) | For streets 18 m. and above. | 2.00 m. | 4.50 m. |
(c) Side & rear marginal distances - Side & rear marginal distances for construction in a plot shall be as below
| Residential Plot Area | Side | Rear |
| Upto 250 sq. m | 0.00 | 0.00 |
| Above 250 &upto 500 sq. m | 1.00 m. | 1.00 m. |
| Above 500 sq. m. &upto 1000 sq.m | 2.00 m. | 2.00 m. |
| Above 1000 sq.m. | As per Regulation no.15.6.a | |
| NOTE :- For light and ventilation, provisions in Regulation no.15.11 shall apply. | ||
d) For streets less than 4.5 m. in width, no setback shall be prescribed subject to condition that no lane shall be less than 4.5 m. in width clear of structural projection. For lanes less than 4.5 m. in width, a setback of 2.25 m. shall be prescribed from the centre line of such lane. Streets less than 4.5 m. shall be treated as lanes only when they serve as access to the properties fronting on them.
e) Above set back and marginal distances shall be applicable for buildings with ground + 23storey or parking + 34storey structures. For buildings having height more than this but less than 15 mtr., marginal distances shall be increased by 1 mtr. For buildings having height more than this, marginal distances shall be as per regulations of non-core area.
f) Structural projections such as balconies, cornices, weather sheds, roof projections etc. shall be allowed in the setback distance prescribed above as per Regulation no. 15.8.
g) Height- The height of the building shall be governed by Regulation no. 15.9.
h) <s>Ground Coverage-The maximum ground coverage shall be 2/3 of the plot area</s> Steps may be allowed within marginal distance.
i) Parking – parking shall be provided as per the provisions in Regulation no.20.0.
15.1.2 Public semipublic, Educational, Medical, Institutional, Mercantile, and Other Buildings
(a) Floor Space Index - Maximum FSI permissible <s>for public semipublic buildings</s> shall be 2.5and <s>for remaining buildings it shall be 2.2.</s> In addition to this premium FSI of 0.30 and TDR of 0.30 shall be permissible. The owner shall have option of availing TDR instead of premium FSI.
(b) Marginal Distance - For these buildings marginal distances shall be 3 m. on all sides.
(c)For buildings having height more than 15 m. regulations of outside core area shall apply for front, side and rear marginal distances.
Provided that for buildings like cinema theatre, multiplex, assembly buildings, shopping malls, regulation of outside core area, except FSI, shall apply.
15.1.3 Pathway for access to the internal building or interior part of the building shall not be less than 3.6m. (12 ft) in width.
15.1.4 If the width of property is less than 3.6 m. (12 ft), the entire ground floor shall be on stilts.
15.1.5 Front setback (marginal distances) as prescribed by the Highway or any other rules shall be applicable if they are over and above as prescribed in these regulations.