No piece of land shall be used as a site for the construction of building
If the Authority considers that the site is insanitary, incapable of being well drained or it is dangerous to construct a building on it;
(b) If the entire site is within a distance of 6 m. from the edge of water mark of a minor watercourse (like nalla) and 15 m. from the edge of water mark of a major water course (like river) shown on Development Plan or village/city survey map or otherwise, provided that where a minor water course passes through a low lying land without any well-defined banks, the owner of the property may be permitted by the Authority to restrict and or to realign the same within the same land along with cross section as determined by the Authority;
(c) If the owner of the plot has not shown to the satisfaction of the Authority all the measures required to safeguard the construction from constantly getting damp;
(d) If the proposed building is for assembly uses, for cinemas / theatres, as well as for public worship which has not been previously approved by the appropriate Authority;
(e) If the building is proposed on any area filled up with carcasses, excreta, filth and offensive matter till the production of certificate from the Authority to the effect that it is safe from the health and sanitary point of view, to be built upon;
(f) If the use of the site is for the purpose, which in the opinion of the Authority will be a source of annoyance to the health and comfort of the inhabitants of the neighbourhood;
(g) If the proposed occupancy of the building on the site does not conform to the land use proposals in the development plans or Zoning Regulations,
(h) If the level of the site is less than prescribed datum level depending on topography and drainage aspects;
(i) If it doesn’t derive access from an authorised street/means of access described in these Regulations;
(j) If it is within the river/lake boundary and blue flood line of the river (prohibitive zone) unless flood protection measures are under taken with the approval and to the satisfaction of the Municipal Commissioner mentioned in these regulations;
(k) If the site is not developable by virtue of restrictions imposed under any law or guidelines of any Government department and;
(l) If the site is hilly and having gradient more than 1:5.
No structure including verandah or balcony shall be allowed to be erected or re-erected or any additions or alterations made to a building on a site within the distance quoted in Table No. 3 below in accordance with the prevailing Indian Electricity Rules and its amendments from time to time between the building and any overhead electric supply line.
Table No. 3
| Electric Lines | Vertically (m.) | Horizontally (m.) |
| (1) | (2) | (3) |
| (a) Low and medium voltage Lines and Service Lines. | 2.5 | 1.2 |
| (b) High voltage lines up to and including 33,000 V. | 3.7 | 2.0 |
| (c) Extra High voltage beyond 33,000 V. | 3.7 | 2.0 |
| (Plus 0.3 m. for every additional 33,000 V. or part thereof) | (Plus 0.3 m. for every additional 33,000 V. or part thereof) | |
| Note: The minimum clearance specified above shall be measured from maximum sag for vertical clearance and from maximum deflection due to wind pressure for horizontal clearance. | ||