No piece of land shall be used as a site for the construction of building
If the Authority considers that the site is insanitary, incapable of being well drained or it is dangerous to construct a building on it;
(b) If the entire site is within a distance of 6 m. from the edge of water mark of a minor watercourse (like nalla) and 15 m. from the edge of water mark of a major water course (like river) shown on Development Plan or village/city survey map or otherwise, provided that where a minor water course passes through a low lying land without any well-defined banks, the owner of the property may be permitted by the Authority to restrict and or to realign the same within the same land along with cross section as determined by the Authority;
(c) If the owner of the plot has not shown to the satisfaction of the Authority all the measures required to safeguard the construction from constantly getting damp;
(d) If the proposed building is for assembly uses, for cinemas / theatres, as well as for public worship which has not been previously approved by the appropriate Authority;
(e) If the building is proposed on any area filled up with carcasses, excreta, filth and offensive matter till the production of certificate from the Authority to the effect that it is safe from the health and sanitary point of view, to be built upon;
(f) If the use of the site is for the purpose, which in the opinion of the Authority will be a source of annoyance to the health and comfort of the inhabitants of the neighbourhood;
(g) If the proposed occupancy of the building on the site does not conform to the land use proposals in the development plans or Zoning Regulations,
(h) If the level of the site is less than prescribed datum level depending on topography and drainage aspects;
(i) If it doesn’t derive access from an authorised street/means of access described in these Regulations;
(j) If it is within the river/lake boundary and blue flood line of the river (prohibitive zone) unless flood protection measures are under taken with the approval and to the satisfaction of the Municipal Commissioner mentioned in these regulations;
(k) If the site is not developable by virtue of restrictions imposed under any law or guidelines of any Government department and;
(l) If the site is hilly and having gradient more than 1:5.
No structure including verandah or balcony shall be allowed to be erected or re-erected or any additions or alterations made to a building on a site within the distance quoted in Table No. 3 below in accordance with the prevailing Indian Electricity Rules and its amendments from time to time between the building and any overhead electric supply line.
Table No. 3
| Electric Lines | Vertically (m.) | Horizontally (m.) |
| (1) | (2) | (3) |
| (a) Low and medium voltage Lines and Service Lines. | 2.5 | 1.2 |
| (b) High voltage lines up to and including 33,000 V. | 3.7 | 2.0 |
| (c) Extra High voltage beyond 33,000 V. | 3.7 | 2.0 |
| (Plus 0.3 m. for every additional 33,000 V. or part thereof) | (Plus 0.3 m. for every additional 33,000 V. or part thereof) | |
| Note: The minimum clearance specified above shall be measured from maximum sag for vertical clearance and from maximum deflection due to wind pressure for horizontal clearance. | ||
Construction within flood line of river Godavari, Darna, Waghadi, Nasardi and Waldevi
i) Area between the river bank and blue flood line (Flood line towards the river bank) shall be prohibited zone for any construction except parking, open vegetable market with otta type construction, garden, open space, cremation and burial ground, <s>public toilet</s> or like uses, provided the land is feasible for utilization.
Provided further that development and redevelopment of the existing properties within river bank and blue flood line, in core area, marked on development plan, may be permitted at a height of 0.45 m. above red flood line level.
Provided further that development of property falling within the river bank and blue flood line, in non-core area, shall be allowed to be developed subject to flood protection measures to be undertaken by the owner to the satisfaction of Municipal Commissioner in consultation with Irrigation Department.
ii) Area between blue flood line and red flood line shall be restrictive zone for the purposes of construction. The construction within this area may be permitted at a height of 0.45 m. above the red flood line level.
iii) If the area between the river bank and blue flood line or red flood line forms the part of the entire plot in developable zone i.e. residential, commercial, public-semi-public, industrial, future urbanizable zone, then, FSI of this part of land may be allowed to be utilised on remaining land.
iv) The blue and red flood line shown on the development plan shall stand modified as and when it is modified by the Irrigation Department.
For any construction within 30 m. from railway boundary, No Objection Certificate from Railway
Authority shall be necessary.
Environmental clearance certificate shall be submitted for the project as may be prescribed by the Ministry of Environment from time to time.
Height restriction in the vicinity of the Gandhi Nagar Airport, as may be specified by the concerned authority from time to time, shall be observed.
A conservation line around Pandav Leni has been earmarked by the Archeological Survey of India. A conservation zone is upto 300 m. from the periphery of Pandav Leni subject to following conditions;
i) No construction activity is permissible within 100 meters distance.
ii) Beyond 100 m. and 300 m. construction is permissible upto a height of 9.0 m. or as specified by Archeological Survey of India form time to time.
iii) For every construction in this area, NOC from Archeological Survey of India is necessary.
The development along the highways shall be subject to the provisions of State Highways Act, 1965 and National Highway Act, 1956 and orders issued by Public Works Department in this regards, from time to time.
A service road of 12 m. wide shall be provided along State and National Highways on both sides. These service road may not be provided where development / construction is already taken place without the provision of the service roads.
The developments within 500 m. from the jail premises may be permitted with prior consent of the committee constituted in this regard vide government order no.UOR-81-2013-UD-11, Dated 4 December, 2013. This provision shall be subject to the orders issued by the Government from time to time.
For any residential development, segregating distance from the land fill site shall be observed as specified under Solid Waste Management Rules in force from time to time.