[See rule 20 (6)]
Completion Certificate Norms
- The following guidelines are issued for the purpose of treating the building as completed for issue of completion certificate
a) In respect of commercial buildings, the following items should have been completed in all respects. However, interior completion works, fixtures, flooring and partition need not be insisted.
(i) Terrace Floor with weathering course including parapet wall
(ii) Lift Machine Room, OHT and Stair-case Head room
(iii) Electrical installations (switch boxes and fixtures not to be insisted)
(iv) Sanitary and water supply installations (fixtures not to be insisted)
(v) Sump for water storage
(vi) Outer plastering of the building
(vii) Frames for joinery
(viii) No dowel rods left out in the building for vertical or horizontal expansion
(ix) Completion of Internal Plastering and Flooring need not be insisted
b) In case of residential buildings, the following items shall have been completed in the said project to consider it for issue of Completion Certificate
(i) Terrace Floor with weathering course including parapet wall
(ii) Lift Machine Room, OHT and Stair-case Head room
(iii) Electrical installations (switch boxes and fixture not to be insisted)
(iv) Sanitary and Water Supply installations (fixtures not to be insisted)
(v) Sump for Water storage
(vi) Outer plastering of the building
(vii) Frames for Joinery
(viii) Kitchen (Provision on Modular Kitchen is permitted provided provision for water supply / drainage is made)
(ix) Internal partition walls
(x) No dowel rods left out in the building for vertical or horizontal expansion
(xi) Completion of Internal Plastering and Flooring need not be insisted.
- Completion Certificate Norms
a) Norms for Non High Rise buildings with GF + 2F or Stilt + 3F subject to a maximum of 12m height with 16 dwellings or up to 300 square meters of commercial building shall be regulated according to the table below:
| Sl. No | Parameters | Norms |
|---|---|---|
| 1. | Dimension of the Building | The increase in the dimension of the building shall not exceed 0.30 mts in length and 0.30 mts in width. |
| 2. | Set Backs | The reduction in setbacks is allowed on all sides by 0.30 mts, subject to availability of minimum set back of 1.20 mts. in the event of prescribed minimum setback being 1.5m and by 0.20 mts subject to availability of minimum set back of 0.80 mts. In the event of prescribed minimum setback being 1.0m |
| 3. | Height of the Building | Increase in height of the building is permitted not exceeding 3% of the building height approved as long as such increase does not exceed 12m and does not constitute an additional floor. In case of Institutional building if it does not exceed 18.30 mts. |
| 4. | FSI Tolerance Limit | FSI Tolerance limit will be maximum of 15 sq.m over and above the permissible FSI. |
| 5. | Over Head Tank | Change in the location/ Architectural orientation permissible. In case of increase in the size of the over head tank necessary fees to be collected. |
| 6. | Inter connection between two flats | Permissible as long as it satisfies parking requirement. |
| 7. | Change in the position of the columns and introduction of new columns in the stilt floor | Permissible as long as it does not affect minimum parking lots required as per approved plan is left as car parking space. Movement and parking of required number of cars on ground can be taken irrespective of certain deviations from the approved plan, subject to conformity to DR provision relating to Parking and Driveway. |
| 8. | Non FSI area | Change in location of incident use as long as within non-FSI area permissible limit. |
| 9. | Variation between document dimension and site dimension | If on site measurements area are less than originally approved from PLR line, but even, this lesser set backs on the site confirm to these rules. |
| 10. | Entrance Arch / Pillar | As per the provision of these rules. |
| 11. | Pergola | Permissible for elevation purpose in the terrace not exceeding 10 % area of the respective floor Pergola projections in other places will be treated as architectural features, as per the provisions of these rules. |
| 12. | Rain Water Harvesting | Should be provided. |
| 13. | Compound wall constructed including the land left for road widening | Not permissible. Permanent compound wall to be constructed as per the approved plan after leaving the street alignment or road widening portion. |
b) Norms for Non High Rise buildings upto 18.30m height and exceeding 16 dwelling units and exceeding 300 square meters of commercial building shall be regulated according to the table below::
| Si. No. | Parameters | Norms |
|---|---|---|
| 1. | Dimension of the building | The increase in the dimension of the building shall not exceed 0.30 mts. In length and 0.30 mts. in width. |
| 2. | Set Backs / Distance Between Blocks. | 0.30 mts. reduction in setbacks is allowed on all sides, subject to availability of minimum set back of 1.20 mts. in the event of prescribed minimum setback being 1.5m and by 0.20 mts subject to availability of minimum set back of 0.80 mts. In the event of prescribed minimum setback being 1.0m |
| 3. | Height of the Building | Increase in height of the building is Permitted not exceeding 3% of the building height approved as long as such increase does not exceed 18.30 mts. and does not constitute an additional floor. In such cases, additional setback for the additional height increase shall not be insisted. |
| 4. | FSI Tolerance Limit | FSI Tolerance limit will be 0.03 of FSI or 50 Sq.mt. floor area whichever is higher over and above the permissible FSI. |
| 5. | OHT | Change in the location/orientation permissible. In case of increase in the size of the OHT, development charges to be collected. |
| 6. | Inter connection between two flats | Permissible as long as it satisfies parking requirement. |
| 7. | Change in the position of the columns and introduction of new columns in the stilt floor. | Permissible as long as it does not affect minimum 3.00 mts. driveway for vehicular movement and the no. of minimum parking lots required as per approved plan is left as car parking space. Movement and parking of required number of cars on ground can be taken irrespective of certain deviations from the approved plan, subject to conformity to TNCBR provision relating to Parking and Driveway. |
| 8. | Non FSI area | Change in location of incidental use within non-FSI area permissible limit. |
| 9. | Variation between document dimension and site dimension | If on site measurements are less than originally approved from PLR line, but even this lesser set backs on the site conform to these rules-Permissible. |
| 10. | Entrance Arch / Pillar | As per the provision of these rules. |
| 11. | Pergola | Permissible for elevation purpose in the terrace not exceeding 10% area of the respective floor. |
| 12. | Rain water harvesting | Should be provided. |
| 13. | Compound Wall constructed including the land left for road widening. |
HARMANDER SINGH, Principal Secretary to Government.
PRINTED AND PUBLISHED BY THE DIRECTOR OF STATIONERY AND PRINTING, CHENNAI ON BEHALF OF THE GOVERNMENT OF TAMIL NADU