Sanitation requirements
The requirement for fitments for drainage and sanitation in the use of buildings other than residential shall be in accordance with tables below
Table: 1. Sanitation requirements for shops and Commercial Offices
| Sl. No. | Sanitary Unit/ Fittings | For Personnel |
|---|---|---|
| 1. | Water closet | One for every 25 persons or part thereof, exceeding 15 (including employees and customers). For female personnel 1 for every 15 persons or part thereof, exceeding 10. |
| 2. | Drinking Water Fountain | One for every 100 persons with a minimum of one on each floor. |
| 3. | Wash Basin | One for every 25 persons or part thereof. |
| 4. | Urinals | Nil up to 6 persons 1 for 7-20 persons 2 for 21-45 persons 3 for 40-70 persons 4 for 71-100 persons From 101 to 200 add at the rate of 3%; For over 200 persons add at the rate of 2.5%. |
| 5. | Cleaners' Sink | One per floor minimum, preferably in or adjacent to sanitary rooms. |
Note: Number of customers for the purpose of the above calculation shall be the average number of persons in the premises for a time interval of one hour during the peak period. For male-female calculation a ratio of 1: 1 may be assumed.
Table:2 Sanitation Requirements for Hotels
Individual guest rooms shall have attached toilets. In addition, the following shall also be provided.
| Sl.No. | Sanitary Unit | For Residential Public staff | For non residential Staff | For non residential Staff |
| Sl.No. | Sanitary Unit | For Residential Public staff | For male | For female |
| 1. | Water Closet (W.C.) | One per 8 Persons omitting occupants of the attached water closet minimum of 2 if both sexes are lodged | 1 for 1-15 persons2 for 16-35 persons3 for 36-65 persons4 for 66-100 persons | 1 for 1-12 persons2 for 13-25 persons3 for 26-40 persons4 for 41-57 persons5 for 58-77 persons6 for 78-100 personsAdd 1 for every 6 persons or part thereof |
| 2. | Ablution Taps | One in each W.C | One in each W.C | One in each W.C. |
| 3. | Urinals | Nil | Nil up to 6 persons 1 for 7-20 persons 2 for 21-45 persons 3 for 40-70 persons 4 for 71-100 persons | Nil |
| 4. | Wash Basins | One per 10 persons | 1 for 15 persons 2 for 16-35 persons 3 for 36-65 persons 4 for 66-100 persons | 1 for 1-12 persons 2 for 13-25 persons 3 for 26-40 persons 4 for 41-57 persons for 58-77 persons 6 for 78-100 persons |
| 5. | Baths | One per 10 persons | Nil | Nil |
| 6. | Cleaner's sinks | One per 10 persons. Less occupants of room with bath in suite | Nil | Nil |
| 7. | Kitchen Sink | One in each Kitchen | One in each Kitchen | One in each Kitchen |
Note: i) It may be assumed that the two-thirds of the number are males and one- third females
ii) One water tap with drainage arrangements shall be provided for every 50 persons or part there of in the vicinity of water closet and urinals.
Table:3 Sanitation Requirements For Public halls
| Sl. No. | Sanitary Unit | For Male | For Female |
| 1. | Water Closet | One per 100 persons upto 400 persons; for over 400 add at the rate of one per 250 persons or part thereof. | Two for 10 persons upto 200 persons; over 200 add at the rate of one per 100 persons or part thereof. |
| 2. | Ablution Taps | One in each W.C. | One in each W.C. |
| 3. | Urinals | One for 50 persons or part thereof. | Nil, upto 6 persons 1 for 7-20 persons 2 for 21-45 persons 3 for 46-70 persons 4 for 71-100 persons |
| 4. | Wash Basins | One per W.C. and urinal provided | One per W.C. provided |
| 5 | Kitchen Sink | One in each kitchen | One in each kitchen |
| 6. | Bath (shower) | One per 10 persons | |
| 7. | Cleaner's sinks | One per 30 Bed rooms (one per floor mimimum) | |
Note: i) It may be assumed that the two-thirds of the number are males and one- third females
ii) One water tap with drainage arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closet and urinals.
Table:4 Sanitation Requirements for Educational Occupancy
| Sl. No. | Sanitary Unit | Boarding Institutions | Other educational Institutions | ||
| Boys | Girls | Boys | Girls | ||
| 1. | Water Closet (W.C.) | One for 8 boys or part thereof | One for 6 girls or part thereof | One for 40 boys or part thereof | One for 25 girls or part thereof |
| 2. | Ablution Taps | One in each W.C. | One in each W.C. | One in each W.C. | One in each W.C. |
| 3. | Urinals | One per every 25 pupils or part thereof | -- | One per every 20 pupils or part thereof | -- |
| 4. | Wash Basins | One for every 8 pupils or part thereof | One for every 6 pupils or part thereof | One for every 40 pupils or part thereof | One for every 40 pupils or part thereof |
| 5. | Baths | One for every 8 pupils or part thereof | One for every 6 pupils or part thereof | -- | -- |
| 6. | Drinking Water Fountains | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof |
| 7. | Cleaner's Sink | One per Floor minimum | One per Floor minimum | One per Floor minimum | One per Floor minimum |
Table:5 Sanitation Requirements for Nursery Schools
| Sl. No. | Sanitary Unit | Requirement |
|---|---|---|
| 1. | Water Closet | One for 15 boys, one for 6 girls |
| 2. | Ablution Taps | One in each W.C. |
| 3. | Urinals | one for 12 boys |
| 4. | Wash Basins | One for every 15 pupils or part thereof |
| 5. | Baths | One bath sink per 40 pupils |
| 6. | Drinking Water Fountains | One for every 50 pupils or part thereof |
| 7. | Cleaner's Sink | One per floor minimum |
Note: 1. One water tap with draining arrangements shall be provided for every 50 persons or part thereof, in the vicinity of water closets and urinal.
- For teaching staff, the schedule of sanitary units to be provided shall be the same as in case of office buildings (Table 1).
Table:6 Sanitation Requirements for Governmental and Public Business Occupancy and Offices
| Sl. No. | Sanitary Unit | For Male Personnel | For female Personnel |
| 1. | Water Closet (W.C.) | One for 25 persons or part thereof | One for 15 persons or part thereof |
| 2. | Ablution taps | One in each W.C. | One in each W.C. |
| 3. | Urinals | Nil upto 6 persons 1 for 7-20 persons 2 for 21-45 persons 3 for 46-70 persons 4 for 71-100 persons From 101 to 200 add at the rate of 3%; For over 200 persons add at the rate of 2.5%. | -- |
| 4. | Wash Basins | One for every 25 persons or part thereof | One for every 25 persons or part thereof |
| 5. | Drinking water fountains | One for every 100 persons with a minimum of one on each floor | One for every 100 persons with a minimum of one on each floor |
| 6. | Cleaner's Sinks | One per floor minimum; preferably in or adjacent to sanitary rooms. | -- |
| 7. | Executive Room / Conference Hall | Toilet Suite (1 WC, 1 washbasin, optional shower for 24 hr usage) Unit could be common for Male / Female or separate depending on the number of user of each facility | |
Note: One water tap with drainage arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closet and urinals.
Table: 7 Sanitation Requirements for Residences
| Sl. No. | Sanitary Unit | Dwelling with individual conveniences | Dwelling without individual conveniences |
|---|---|---|---|
| 1. | Bath Room | One provided with water tap | One for every two tenement |
| 2. | Water Closet (W.C.) | One | One for every two tenement |
| 3. | Sink (or Nahani) in the Floor | One | -- |
| 4. | Water Tap | One | One with drainage arrangement in each tenement One in common bath rooms and common water closet. |
Note: Where only one water closet is provided in a dwelling, the bath and water closet shall be separately accommodated.
Table:8 Sanitation Requirements for Assembly Occupancy Buildings (Cinema, Theaters, Auditoria. etc.)
| Sl. No. | Sanitary Unit | For Public | For Staff | ||
| Male | Female | Male | Female | ||
| 1. | Water Closet | One for 100 persons upto 400 persons. For over 400 persons, add at the rate of 1 per 250 persons or part thereof | Two per 100 persons upto 200 persons. For over 200 persons add at the rate of 1 per 100 persons or part thereof | One for 15 persons. Two for 16-35 persons | One for 1-12 persons. Two for 13-25 persons add at the rate of 1 per 6 persons or part thereof |
| 2. | Ablution Taps | One in each W.C. | One in each W.C. | One in each WC | One in each WC |
| 3. | Urinals | One for 50 persons or part thereof | _____ | Nil upto 6 persons One for 7-20 persons Two for 21-45 persons | _____ |
| 4. | Wash Basins | One for every 200 persons or part thereof | One for every 200 persons or part thereof | One for 1-15 persons Two for 16-35 | One for 1-12 persons Two for 13-25 persons |
| 5. | Drinking Water Fountain | One per 100 persons or part thereof | |||
| 6. | Cleaner's sink | One per floor | |||
| 7. | Shower / Bathing | As per trade requirement | |||
Note: - i) One water tap with draining arrangements shall be provided for every 50 persons or part
thereof in the vicinity of water closets and urinals.
ii) It may be assumed that two thirds of the numbers are males and one third females.
Table:9 Sanitation Requirements for Assembly Buildings (Art, Galleries, Libraries and Museums)
| Sl. No. | Sanitary Unit | For Public | For Staff | ||
| Male | Female | Male | Female | ||
| 1. | Water Closet (W.C.) | One for 200 persons upto 400 persons. For over 200 persons, add at the rate of 1 per 250 persons or part thereof | One per 100 persons upto 200 persons. For over 200 persons, add at the rate of 1 per 150 persons or part thereof | One for 1-15 persons. Two for 16-35 persons | One for 1-12 persons. Two for 13-25 persons, add at the rate of 1 per 6 persons or part thereof |
| 2. | Ablution Taps | One in each W.C. | One in each W.C. | One in each W.C | One in each W.C |
| 3. | Urinals | One for 50 persons or part thereof | -- | Nil upto persons One for 7-20 persons Two for 21-45 persons | -- |
| 4. | Wash Basins | One for every 200 persons or part thereof. For over 400 persons, add at the rate of 1 per 250 persons or part thereof. | One for every 200 persons or part thereof. For over 200 persons, add at the rate of 1 per 150 persons or part thereof | One for 1-15 persons Two for 16-35 | One for 1-12 persons Two for 13-25 persons |
| 5. | Cleaner's Sink | One per floor, minimum | |||
| 6. | Drinking Water Fountain | One per 100 persons or part thereof | |||
| 7. | Shower/Bath | As per each kitchen | |||
Table :10 Sanitation Requirements for Restaurants
| Sl.No. | Sanitary Unit | For Public | For Staff | ||
| Male | Female | Male | Female | ||
| 1. | Water Closet (W.C.) | One per 50 seats upto 200 seats. For over 200 seats, add at the rate of 1 per 100 seats or part thereof | One per 50 seats upto 200 seats. For over 200 seats, add at the rate of 1 per 100 seats or part thereof | ||