Structural Design and Safety
Indian Standards to be taken into consideration for structural design of foundations, elements of masonry, timber, plain concrete, reinforced concrete, pre-stressed concrete and structural steel are given below:
For General Structural Safety
(1) IS: 456:2000 “Code of Practice for Plain and Reinforced Concrete”
(2) IS: 800-1984 “Code of Practice for General Construction in Steel”
(3) IS: 801-1975 “Code of Practice for Use of Cold Formal Light Gauge Steel Structural Members in General Building Construction”
(4) IS 875 (Part 2):1987 “Design loads (other than earthquake) for buildings and structures Part2 Imposed Loads”
(5) IS 875 (Part 3):1987 “Design loads (other than earthquake) for buildings and structures Part 3 Wind Loads”
(6) IS 875 (Part 4):1987 “Design loads (other than earthquake) for buildings and structures Part 4 Snow Loads”
(7) IS 875 (Part 5):1987 “Design loads (other than earthquake) for buildings and structures Part 5 special loads and load combination”
(8) IS: 883:1994 “Code of Practice for Design of Structural Timber in Building”
(9) IS: 1904:1986 “Code of Practice for Structural Safety of Buildings: Foundation”
(10) IS1905:1987 “Code of Practice for Structural Safety of Buildings: Masonry Walls”
(11) IS 2911 (Part 1): Section 1:2010 “Code of Practice for Design and Construction of Pile Foundation Section 1
Part 1: Section 2 Bored Cast-in-situ Piles
Part 1: Section 3 Driven Precast Concrete Piles
Part 1: Section 4: 1984 Bored precast Concrete Piles
Part 2: 1980 Timber Piles
Part 3 1980: Under Reamed Piles
Part 4 1985: Load Test on Piles”
For Cyclone/Wind Storm Protection
(12) IS 875 (3)-1987 "Code of Practice for Design Loads (other than Earthquake) for Buildings and Structures, Part 3, Wind Loads"
(13) Guidelines (Based on IS 875 (3)-1987) for improving the Cyclonic Resistance of Low rise houses and other building
For Earthquake Protection
(14) IS: 1893-2002 "Criteria for Earthquake Resistant Design of Structures (Fifth Revision)"
(15) IS: 13920-1993 "Ductile Detailing of Reinforced Concrete Structures subjected to Seismic Forces - Code of Practice"
(16) IS: 4326-1993 "Earthquake Resistant Design and Construction of Buildings - Code of Practice (Second Revision)"
(17) IS: 13828-1993 "Improving Earthquake Resistance of Low Strength Masonry Buildings - Guidelines"
(18) IS: 13827-1993 "Improving Earthquake Resistance of Earthen Buildings - Guidelines",
(19) IS: 13935-1993 "Repair and Seismic Strengthening of Buildings -Guidelines"
(20) The repair of structures should be undertaken as per IS:15988
For Protection of Landslide Hazard
(21) IS 14458 (Part 1): 1998 Guidelines for retaining wall for hill area: Part 1 Selection of type of wall.
(22) IS 14458 (Part 2): 1997 Guidelines for retaining wall for hill area: Part 2 Design of retaining/breast walls
(23) IS 14458 (Part 3): 1998 Guidelines for retaining wall for hill area: Part 3 Construction of dry stone walls
(24) IS 14496 (Part 2): 1998 Guidelines for preparation of landslide – Hazard zonation maps in mountainous terrains: Part 2 Macro-zonation
Note: Whenever an Indian Standard including those referred in the National Building Code or Bureau of Indian Standards is referred, the latest revision and additions of the same shall be followed except specific criteria, if any, mentioned above against that code.