- Structural Safety.— (1) In the cases of Non High Rise buildings with height upto 12m., industrial or institutional buildings upto G+1 floors in height and with floor area both existing and proposed not exceeding 300 sq.m. the provisions in this part of the rules relating to structural design, submission of working drawings or structural drawings, etc. shall not apply except that all such applications and plans for these developments shall be signed by the owner or Registered Developer, and the Registered Engineer or Architect who prepared the plan and further the Registered Engineer or Architect shall certify that the structural design of the small development has been done as per the latest Indian standard Specifications and the National Building Code.
(2) Structural design.— The structural design of foundations, elements of masonry, timber, plain concrete, reinforced concrete, pre-stressed concrete and structural steel shall conform to the provisions of part VI Structural Design Section – 1 Loads, Section – 2 Foundation, Section – 3 Wood, Section – 4 Masonry, Section – 5
Concrete and Section – 6 Steel of National Building Code of India, taking into consideration the Indian Standards as given in the Annexure - XI
(3) Structural Design Basis Report [SDBR] .— Drawings and Documents to be submitted for approval of appropriate authorities shall include SDBR. In compliance of the design with the Indian Standard the Registered Structural Engineer on Record shall submit a structural design basis report in Form 1 in Annexure - XIV.
(4) Review of Structural Design.—The competent authority for issue of Building permit in case of Village Panchayats, if necessary, shall constitute a Structural Design Review Panel (SDRP) consisting of senior SERs whose task will be to review and certify the design prepared by SER for all High Rise buildings and in cases of other developments whenever referred by the competent authority excluding for Non High Rise buildings with height upto 12m.
(5) Certification Regarding Structural Safety in Design.— The Registered Structural Engineer on Record (SER) shall give a certificate of structural safety of design as per Proforma given in Form8 in Annexure - XIV at the time of completion and structural inspection report as per proforma given in Form 9 at different stages of construction.
(6) Constructional Safety.— (a) All construction except Non High Rise buildings with height upto 12m. shall be carried out under supervision of the Registered Construction Engineer on Record (CER)
(b) CER shall give a certificate of structural safety of construction while submitting the progress report as per proforma given in Form 3 and 4 in Annexure - XIV at the different stages of construction and at the time of completion as per proforma given in Form 7 in Annexure - XIV.
(7) Quality Control and Inspection.— (a) All High rise building construction with more than 18.30m. in height shall be carried out under quality inspection program prepared and implemented under the the Registered Quality Auditor on Record (QAR).
(b) The Registered Quality Auditor on Record (QAR) shall give a certificate of quality control as per proforma given in Form10 in Annexure - XIV .
(c) Quality Inspection Programme to be carried on the site shall be worked out by QAR in consultation with the owner, builder, CER.
(8) Protective Measures in Natural Hazard Prone Areas.— In natural hazard prone areas, structures, buildings and installations, which cannot be avoided, such constructions or developments should be properly safeguarded by taking protective measures as recommended in Annexure - XII
(9) Maintenance of buildings in seismic Zone-III.— In case of High rise buildings and buildings for public assembly older than fifty years, it shall be the duty of the owner of a building, to get his building inspected by a Registered Structural Engineer (RSE) within a year from the date of coming into force of these rules. The Structural Inspection Report in Form 9 in Annexure - XIV shall be produced by the Owner to the competent authority. If any action, for ensuring the structural safety and stability of the building is to be taken, as recommended by SER, it shall be completed within five years. For other buildings less than fifty years old, the owner shall get his building inspected after the age of building has crossed fifty years. The procedure shall be followed as per above rule.
(b) Seismic Strengthening or Retrofitting.—Prior to seismic strengtheningor retrofitting of any existing structure, evaluation of the existing structure as regards structural vulnerability in the specified windor seismic hazard zone shall be carried out by a Registered Structural Engineer. If as per the
evaluation of the Registered Structural Engineer the seismic resistance is assessed to be less than the specified minimum seismic resistance as given in the “note” below, action should be initiated to carry out the upgrading of the seismic resistance of the building as per applicable standard guidelines.
Note:
(i) for masonry buildings reference is to be made to IS: 4326 and IS: 13935 and
(ii) for concrete buildings and structures reference to be made to IS code on evaluation and seismic strengthening for retrofitting of RCC buildings under preparation at present.
- Requirements of parts of buildings.— (1) Plinth.— (a) Main buildings: The plinth or any part of a building or out house shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth shall be not less than 45 cm from the surrounding ground level. However in flood prone areas, plinth shall be above the maximum flood level notified by the concerned authority.
(b) Interior court yards and covered parking areas shall be raised at least 15 cm above the determining ground level and shall be satisfactorily drained.
(2) Walls .— (a) The outer walls of a building shall be constructed of bricks or stone or other incombustible material.
(b) All walls of a building must be properly bonded.
(c) Damp-Proof
(i) Every wall and pier of the building except when built on materials such as steel or reinforced cement concrete shall be provided with a dampproof course.
(ii) Damp-proof course shall be laid at a level not higher than the lowest part of underside of the construction of the ground floor and shall extend to the full width and extent of such walls or piers. It shall be at least two centimeters thick. Where the damp-proof course is provided below the plinth level, vertical damp-proof course shall be provided between the floor and the inside of the plinth.
(3) Paving materials.— In the case of every building intended to be used for human habitation, every part of each floor of such building, including every passage and airy verandah therein, every lavatory, urinal, washing or bathing place included in it, shall be laid or paved with stone or non-absorbent tiles laid in cement or other durable material, impervious to moisture.
(4) Structural metal.— shall not be used for conducting electrical or service currents:
Provided that such metal may be used as part of a sufficient and properly earthed apparatus for protection of the building against damage by lightening.
(5) Habitable rooms.— (a) Height: The height of all rooms for human habitation shall not be less than 2.75m measured from the surface of the floor to the lowest point of the ceiling bottom of slab. In the case of pitched roof, the average height of rooms shall not be less than 2.75m. The minimum clear head room under a beam, folded plates or eaves shall be 2.4m. In the case of air conditioned rooms, a height of not less than 2.5m measured from the surface of the floor to the lowest point of air conditioning duct or the false ceiling shall be provided.
(b) Size: The area of habitable room shall not be less than 7.5sq.m with a minimum width of 2.4m. Pooja room, or store room shall not be taken as a habitable room]
(6) Kitchen.— (a) Height: The height of a kitchen measured from the surface of the floor to the lowest point of the ceiling (bottom slab) shall not be less than 2.75m, except for the portion to accommodate floor trap of the upper floor.
(b) Size: The area of a kitchen where separate dining area is provided shall be not less than 5.0 sq.m. with a minimum width of 1.8m. where there is a separate store, the area of the kitchen may be reduced to 4.5sq.m. A kitchen, which is intended for use as a dining area also, shall have a floor area of not less than 7.5 sq.m. with a minimum width of 2.1m.
(c) Other requirements: Every room to be used as kitchen shall have:
(i) Unless separately provided in a pantry, means for the washing of kitchen utensils which shall lead directly are through a sink to a grated and trapped connection to the waste pipe;
(ii) an impermeable floor;
(iii) a flue, if found necessary; and
(iv) a window or ventilator or opening.
(7) Bathrooms and Water closets.— (a) Height: The height of a bathroom or water closets measured from the surface of the floor to the lowest point in the ceiling bottom of slab shall not be less than 2.1m.
(b) Size: The area of a bath room shall not be less than 1.4 sq.m. with a minimum width of 1.0m. The floor area of water closet shall be 1.0 sq.m. with a minimum width of 0.9m. If bath and water closet are combined, its floor area shall not be less than 2.4sq.m. with a minimum width of 1.2m.
(c) Other requirements: Every bath room or water closet shall:
(i) be so situated that at least one of its walls shall open to external air;
(ii) not be directly over or under any room other than another water closet,
(iii) washing place, bath or terrace, unless it has a water-tight floor;
(iv) be enclosed by walls or partitions and the surface of every such wall or
partitions shall be finished with a smooth impervious material to a height of not less than 1m above the floor of such a room;
(v) be provided with an impervious floor covering, sloping towards the drain with a suitable grade and not towards varandah or any other room; and
have a window or ventilator, opening to a shaft or open space, of area not less than 0.3 sq.m.
(vi) the door of the water closet or bath not to be directly opened to a kitchen
(8) Mezzanine Floor.— (a) Height - It shall have a minimum height of 2.2 m.
(b) Size- The minimum size of the mezzanine floor, if it is to be used as a living room shall not be less than 9.5 sq.m.. The aggregate area of such mezzanine floor in a building shall in no case exceed 1/2nd the plinth area of the building.
(c) Other Requirements - A mezzanine floor may be permitted over a room or a compartment provided:
(i) it conform to the standard of living rooms as regards lighting and ventilation in case the size of mezzanine floor is 9.5 sq.m. or more;
(ii) it is so constructed as not to interfere under any circumstances with the ventilation of the space over and under it;
(iii) such mezzanine floor is not sub-divided into smaller compartments;
(iv) such mezzanine floor or any part of it shall not be used as a kitchen; and
(v) in no case shall a mezzanine floor be closed so as to make it liable to be converted into unventilated compartments.
(9) Store room.— Height: The height of a storeroom shall be not less than 2.2m.
Size: The size of a storeroom, where provided in a residential building, shall be not less than 3sq.m.
(10) Garage.— Height - The height of a garage shall be not less than 2.4 m.
Size - The size of garages shall be as below:
a) Private Garage - 3.0m × 6.0m, minimum; and
b) Public Garage - Based on the number of vehicles parked by Equivalent Car Unit .
(11) Basement.— (a) The basement shall not be used for residential purposes
(b) The basement shall have the following requirements:
(i) Every basement used for non-habitable purposes shall be in every part at least 2.4m in height from the floor to the underside of the roof slab or ceiling; for habitable purposes, it shall conform to the standards prescribed for habitable rooms above.
(ii) Adequate ventilation shall be provided for the basement. The ventilation requirements shall be the same as required by the particular occupancy according to National Building Code. Any deficiency may be met by providing adequate mechanical ventilation in the form of blowers, exhaust fans, air conditioning systems, etc.;
(iii) Adequate arrangements shall be made such that surface drainage does not enter the basement;
(iv) The walls and floors of the basement shall be water-tight and be so designed that the effects of the surrounding soil and moisture, if any, are taken into account in design and adequate damp proofing treatment is given; and
(v) The access to the basement shall be separate from the main and alternative staircase providing access and exit from higher floors. Where the staircase is continuous in the case of building served by more than one staircase, the same shall be of enclosed type serving as a fire separation from the basement floor and higher floors.
(vi) The exit requirements in basements shall comply with the provisions of the NBC Part 4 ‘Fire and Life Safety’
(12) Chimneys.— The chimneys shall be built at least 0.9 m above flat roofs, provided the top of the chimneys is not below the top of the adjacent parapet wall. In the case of sloping roofs, the chimney top shall not be less than 0.6 m above the ridge of the roof in which the chimney penetrates.
(13) Parapet.— Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc. shall not be less than 1.2m and not be more than 1.5m in height from the finished floor level.
(14) Roofs.— (a) The roof of a building shall be so designed and constructed as to effectively drain water by means of sufficient rain-water pipes of adequate size wherever required, so arranged, jointly and fixed as to ensure that the rain-water is carried away from the building without causing dampness in any part of the walls, roof or foundations of the building or an adjacent building.
(b) Rain-water pipes shall be affixed to the outside of the external walls of the building or in recesses or chases cut or formed in such external walls or in such other manner.
(c) Conservation of rain-water using suitable rainwater harvesting techniques including by roof water collection shall be made.
(15) Mosquito-proof Water Tank.— Water storage tank shall be maintained in a perfect mosquito-proof condition, by providing a properly fitting hinged cover, and every tank more than 1.50mts. in height shall be provided with a permanently fixed iron ladder to enable inspection by anti-malaria staff.
(16) Lighting and Ventilation.— Rooms shall have, for the admission of light and air, one or more openings, such as windows and ventilators, opening directly to the external air or into an open verandah.
(a) Notwithstanding the area of openings stated above, the minimum aggregate area of such openings, excluding doors inclusive of frames, shall be not less than one- eighth of the floor area;
Note:
(i) If a window is partly fixed, the openable area shall be counted
(ii) No portion of a room shall be assumed to be lighted, if it is more than 7.5m away from the opening assumed for lighting that portion.
(iii) The area of openings as given above shall be increased by 25% in the case of a kitchen
(iv) in cases where the ventilation is derived through open to sky. the dimensions of the open to sky need to be 1.5m x 2.5m. This will apply to kitchens and store rooms but not to lavatories and bath rooms which shall have windows or ventilators of not less than 0.5sq.m. abutting such open space
(b) For requirements regarding lighting and ventilation for different uses and occupancy reference shall be made to the NBC Part 8 ‘Building Services, Section 1 Lighting and Ventilation’.
(17) Stairways Requirements.— (a) Minimum width of staircase shall be:
(i) (a) Ordinary Residential buildings…… 0.75 m
(b) Other Residential buildings 0.90 m
(ii) Assembly buildings like : Auditoria, assembly halls….. 2.00 m
(iii) All other buildings… 1.50 m
(iv) Educational institutions… 2.00 m
b) Minimum tread
The minimum width of tread without nosing shall be 250mm for residential buildings. The minimum width of tread for other buildings shall be 300mm. In case of spiral staircases, it shall have the above minimum tread width at the outer end.
c) Maximum riser
The maximum height of riser shall be 190 mm for residential buildings and 150 mm for other buildings and these shall be limited to 15 per flight.
d) The minimum headroom in a passage under the landing of a staircase shall be 2.2m. The minimum clear headroom in any staircase shall be 2.2m.
- Exit Requirements.— (1) The following general requirement shall apply to exits:
(a) Every building meant for human occupancy shall be provided with exits sufficient to permit safe movement and also escape of occupants in case of fire or other emergency.
(b) All exits shall be free of obstructions.
(c) No building shall be altered so as to reduce the number, width or portion of exits to less than required.
(d) Exits shall be clearly visible and the routes to reach exits shall be clearly marked and signs posted to guide the occupants of floor concerned.
(e) All exit ways shall be properly illuminated.
(f) Fire fighting equipment where provided along exits shall be suitably located and clearly marked but must not obstruct the exit way and there should be clear indication about its location from either side of the exit way.
(g) Alarm devices shall be installed to ensure prompt evacuation of the occupants concerned through the exits, wherever required.
(h) All exits shall provide continuous means of egress to the exterior of a building or to an exterior open space leading to a street.
(i) Exits shall be so arranged that they may be reached without passing through another occupied unit, except in the case of residential buildings.
(2) Types of Exits.— (a) Exits shall be either horizontal or vertical type. An exit may be doorway, corridor and passage to an internal staircase or external staircase, ramp or to a verandah and/or terraces that have access to the street or to roof of a building. An exit may also include horizontal exit leading to an adjoining building at the same level.
(b) Lifts, escalators and revolving doors shall not be considered as exits.
(3) Number and size of Exits.— The requisite number and size of various exits shall be provided, based on the occupants in each room and floor based on the occupant
load, capacity of exits, travel distance and height of buildings as per provisions of the NBC Part 4 ‘Fire and Life Safety’.
(4) Arrangement of Exits.— Exits shall be so located so that the travel distance on the floor shall not exceed 22.50m. for residential, educational, institutional and hazardous occupancies and 30m. for assembly, business, mercantile, industrial and storage occupancies. Whenever more than one exit is required for a floor of a building they shall be placed as remote from each other as possible. All the exits shall be accessible from the entire floor area at all floor levels.
(b) The travel distance to an exit from the dead end of a corridor shall not exceed half the distance as stated above except in the case of institutional occupancy in which case it shall not exceed 6m.
(5) Passenger elevators or lifts.— (a) Every High rise building, in addition to the stair-case, shall be provided with lift or lifts, depending on the number of persons using each floor and which shall be installed at such places and at such distances as prescribed in the National Building Code.
(b) Every lift shall be in conformity with the following requirements:
(i) The lift way and the car shall be enclosed.
(ii) The lift shaft shall be enclosed with fire resisting materials and shall be ventilated from the highest point direct to the open air.
(iii) The motors, the winding gear and the operating mechanism shall be installed in a chamber constructed of fire resisting materials and shall be ventilated from the highest point direct to the open air.
(iv) These shall be fitted with an inter-locking device of such a type as will prevent,
(a) all landing doors, other than the door to be opening at which the lift car is at rest, from being opened and
(b) the car being moved until all doors, including the car door, are closed.
(v) Precautionary measures shall be adopted to ensure the safety of passengers in the event of:-
(a) an interruption or failure of electric supply;
(b) a defect or failure in the controlling mechanism;
(c) the rupture or displacement of ropes or shelves;
(d) over running or excessive speed of the lift-car due to electrical or other defects in the motor or other mechanism;
(e) the loading of the car in excess of its maximum capacity; and
(f) articles falling upon the lift.
(vi) The safe carrying capacity of the lift or elevator shall be conspicuously posted in or on the car or platform.
(vii) Every lift shall be properly lighted.
(viii)Once in every year, lift shall be got inspected and certified by a competent Engineer
(c) For requirements regarding planning, designing and installation, etc. of lifts and escalators, reference shall be made to the NBC Part 8 ‘Building Services Section 5 Installation of Lifts and Escalators’.