[See rule 51 (3)]
Form 1
Structural Design Basis Report
(1) This report to accompany the application for Building Developments
| Part1 | General Data | |||
| S.No. | Description | Information | Notes | |
| 1. | Site Address...... | |||
| 2 | Name of Owner | |||
| 3 | Name of Registered Developer along with the Registration Number | |||
| 4 | Name of Registered Architect/Engineer along with the Registration Number | |||
| 5 | Name of Registered Structural engineer along with the Registration Number | |||
| 6 | Use of the building | |||
| 7 | Number of stories above ground level (including storeys to be added later, if any) | |||
| 8 | Number of basements below ground level | |||
| 9 | Type of structureLoad bearing wallsR.C.C. frameR.C.C. frame and Shear WallsSteel frame | |||
| 10 | Soil dataType of soilDesign safe bearing capacity | IS:1893 C1.6.3.5.2IS: 1904IS: 1892IS: 2131IS: 2720 | ||
| 11 | Dead loads (unit weight adopted)EarthWaterBrick masonryPlain cement concreteReinforced cement concreteFloor finishOther fill materials | IS: 875 Part 1 | ||
| 12 | Imposed (live) loads | IS: 875 Part 2 | ||
| Floor loadsRoof loads | ||||
| 13 | Cyclone/WindSpeedDesign pressure intensity | IS: 875 Part 3 | ||
| 14 | Seismic zone | IS: 1893 (2002) | |
|---|---|---|---|
| 15 | Importance factor | IS:1893(2002) Table 6 | |
| 16 | Seismic zone factor (Z) | IS:1893 Table 2 | |
| 17 | Response reduction factor | IS:1893 Table 7 | |
| 18 | Fundamental natural period - approx. | IS:1893 C1.7.6 | |
| 19 | Design horizontal acceleration spectrum value (A<sub>h</sub>) | IS: 1893 C1.6.4.2 | |
| 20 | ♥ Expansion/Separation Joints | ||
| 21 | Building is regular/irregular | IS 1893 |
Enclose detailed drawings drawn to scale for each floor
In case terrace garden is provided, indicate additional fill load and live load along with the detailed drawings drawn to scale
| Part 2 Load bearing masonry buildings | Part 2 Load bearing masonry buildings | Part 2 Load bearing masonry buildings | Part 2 Load bearing masonry buildings |
| Sl.No. | Description | Information | Notes |
| 1 | Building category | IS: 4326 C1.7Read with IS:1893 | |
| 1 | Building category | ZoneBldg. | II III IV V |
| 1 | Building category | Ordinary | B C D E |
| 1 | Building category | Important | C D E E |
| 2 | Basement Provided | ||
| 3 | Number of floors including Ground Floor (all floors including stepped floors in hill slopes) | ||
| 4 | Type of wall masonry | ||
| 5 | Type and mix of Mortar | IS: 4326 C1.8.1.2 | |
| 6 | Re: size and position of openings (See note No.[i])Minimum distance (b5)Ratio ( b₁+b₂+b₃ )/ 1₁ or ( b₆+b₇ )/ 1₂ Minimum pier width between consequent opening ( b₄ )Vertical distance ( h₃ )Ratio of wall height to thickness 4Ratio of wall length between cross wall to thickness | IS: 4326 Table 4, Fig.7 | |
| 7 | Horizontal seismic bandat plinth levelat window sill levelat lintel levelat ceiling level | P IP NA☐ ☐ ☐☐ ☐ ☐☐ ☐ ☐ | (see note No.2)IS:4326 C1 8.4.6IS: 4326 C1 8.3IS: 4326 C1 8.4.2IS: 4326 C1 8.4.3IS: 4326 C1 8.4.3 |
| at eave level of sloping roof at top of gable walls at top of ridge walls | � � �� � �� � � | IS: 4326 C1 8.4.3 IS: 4326 C1 8.4.4 | |
| 8 | Vertical reinforcing bar at corners and T junction of walls at jambs of doors and window openings | � � �� � � | IS: 4326 C1 8.4.8. IS: 4326 C1 8.4.9 |
| 9 | Integration of prefab roofing/flooring elements through reinforced concrete screed. | � � � | IS:4326 C1 9.1.4 |
| 10 | Horizontal bracings in pitched truss in horizontal plane at the level of ties in the slopes of pitched roofs | � � �� � � |
Notes: (i) Information in Item 6 should be given on separate A4 sheets for all walls with large number of openings
(ii) IP indicated “Information Provided”
IP indicates “Information to be provided”
NA indicates “Not Applicable”
Tick mark one box
| Part 3 | Reinforced concrete framed buildings | Reinforced concrete framed buildings | Reinforced concrete framed buildings |
| Sl. No. | Description | Information | Notes |
| 1 | Type of building Regular frames Regular frames with Shear Walls Irregular frames Irregular frames with Shear Walls Soft storey | IS: 1893 C1 7.1 | |
| 2 | Number of basements | ||
| 3 | Number of floors including ground floor | ||
| 4 | Horizontal floor system Beams and slabs Waffles Ribbed floor Flat slab with drops Flat plate without drops | ||
| 5 | Soil data Type of soil Recommended type of foundation -Independent footings -Raft -Piles Recommended bearing capacity of soil Recommended type, length, diameter and load capacity of pilesDepth of water tableChemical analysis of ground waterChemical analysis of soil | IS: 1498 | |
| 6 | FoundationsDepth below ground levelTypeIndependentInterconnectedRaftPiles | ||
| 7 | System of interconnecting foundationsPlinth beamsFoundation beams | IS: 1893 C1 7.12.1 | |
| 8 | Grades if concrete used in different parts of building | ||
| 9 | Method of analysis used | ||
| 10 | Computer software used | ||
| 11 | Torsion included | IS: 1893 C1 7.9 | |
| 12 | Base sheara. Based on approximate fundamental periodb. Based on dynamic analysisc. Ratio of a/b | IS: 1893 Cl. 7.5.3 | |
| 13 | Distribution of seismic forces along the height of the building. | IS:1893 Cl.7.7(Provide sketch) | |
| 14 | The Column of soft ground storey specially designed. | IS: 1893 Cl.7.10 | |
| 15 | Clear minimum cover provided inFootingColumnBeamsSlabsWalls | IS: 456 Cl. 26.4 | |
| 16 | Ductile detailing of RC frameType of reinforcement usedMinimum dimension of beamsMinimum dimension of columnsMinimum percentage of reinforcement of beams at any cross sectionMaximum percentage of reinforcement at any section of beamSpacing of transverse reinforcement in 2-d length of beams near the endsRatio of capacity of beams in shear to capacity of beams in flexureMaximum percentage of reinforcement in column · Confining stirrups near ends of columns and in beam-column joints Diameter Spacing· Ratio of shear capacity of columns to maximum seismic shear in the storey. |
Foundation
i. In case raft foundation has been adopted, indicate K value used for analysis of the raft.
ii. Incase pile foundations have been used, give full particulars of the piles, type, dia, length, capacity
iii. In case of high water table, indicate system of countering water pressure, and indicate the existing water table, and that assumed to design foundations.
Idealization for Earthquake analysis
i. In case of composite system of shear walls and rigid frames, give distribution of base shear in the two systems on the basis of analysis, and that used for design of each system
ii. Indicate the idealization of frames and shear walls adopted in the analysis with the help of sketches.
iii. Submit framing plans of each floor
iv. In case of basements, indicate the system used to contain earth pressures.
| Part 4 | Buildings in structural steel | Buildings in structural steel | Buildings in structural steel |
| 1 | Adopted method of design | o Simple o Semi-rigid o Rigid | IS:800 Cl 3.4.4 IS:800 Cl.3.4.5 IS:800 Cl.3.5.6 |
| 2 | Design based on | o Elastic analysis o Plastic analysis | IS: 800 Section-9 SP;6 (6) |
| 3 | Floor construction | o Composite o Non composite o Boarded | |
| 4 | Roof construction | o Composite o Non composite o Metal o Any other | |
| 5 | Horizontal force resisting system adopted | Frames Braced frames Frames & shear walls | Note: Seismic force As per IS:1893 Would depend on system |
| 6 | Slenderness ratios maintained | Members defined in Table 3.1, IS:800 | IS 800; Cl.3.7 |
| 7 | Member deflection | Beams, Rafters | IS:800 Cl.3.13 |
| limited to | Crane Girders, PurlinsTop of columns | ||
| 8 | Structural members | ○ Encased in concreteNot encased | IS: 800 Section-10 |
| 9 | Proposed material | ○ General weld-able○ High strength○ Cold formed○ Tubular | IS: 2062IS: 8500IS: 801, 811IS: 806 |
| 10. | Minimum metal thickness Specified for corrosion protection | ○ Hot rolled sections○ Cold formed sections○ Tubes | IS: 800, Cl.3.8Cl.3.8.1 to Cl.3.8.4Cl.3.8.5 |
| 11 | Structural connections | ○ Rivets○ CT Bolts○ S H F G Bolts○ Black Bolts○ Welding fieldShop (Specify welding type proposed) Composite | IS: 800, Section-8IS: 1929, 2155, 1149IS 6639, 1367IS 3757, 4000IS: 1363, 1367IS: 816, 814,1395, 7280, 3613, 6419, 6560, 813, 9595 |
| 12 | Minimum Fire rating proposed, with method | ○ Rating......hourso○ Method proposed.-In tumescent painting-Spraying-Quilting-Fire retardant boarding | IS: 1641, 1642, 1643 |