22.0 Regulations for Sub-division of Plots
(1) Generally:
(a) a plot to be sub-divided shall be termed as "mother plot";
(b) sub-division shall not be allowed if the “mother plot” abuts a means of access having a width of less than 3.50 metres;
(c) every individual plot obtained by sub-division of the “mother plot” shall abut a means of access having a width of not less than 3.50 metres;
(d) the junctions of means of access within the “mother plot” shall be provided with splayed corners measuring not less than 2.50 metres on each side;
(e) these regulations are not applicable in a scheme for Economically Weaker Section and Low Income Group Housing approved by the Calcutta Metropolitan Development Authority;
(f) sub-division may be allowed on condition that the following facilities shall be provided by the owner of the “mother plot” at his own cost, as may be indicated by the Local Authority:
(i) drainage facilities ensuring drainage of each individual plot and of the means of access and passages leading to existing public drains or drainage channels;
(ii) streets and passages along with street lighting;
(iii) sanitary facilities including garbage disposal facilities;
(iv) water supply facilities;
(2) Width and length of means of access:
The maximum length permissible for the means of access shall be as given in the table below:
TABLE
| Width of means of access | Maximum length of the means of access | ||
| For means of access closed at one end | For means of access open to street at both ends | ||
| (i) | 3.50 metres and above but not more than 7.00 metres | 25.00 metres | 75.00 metres |
| (ii) | Above 7.00 metres but not more than 10.00 metres | 50.00 metres | 150.00 metres |
| (iii) | Above 10.00 metres | No restriction | No restriction |
(3) Public open space:
For "mother plot" measuring more than 5,000.00 sq. metres in area, sub-division may be allowed, provided eight per cent of the total area of "mother plot" is developed as public open space. The width of each such open space shall not be less than 10.00 metres and each such open space shall abut a street having a width of not less than 7.00 metres. The minimum area of each such open space in one parcel shall be 400.00 sq. metres. This open space shall be in addition to the land required for providing the means of access to the individual plots obtained by sub-division of "mother plot".
(4) Land for facilities:
For “mother plots” measuring more than 25,000.00 sq. metres in area, sub-division may be allowed, provided seven per cent of the total area of the mother plot is reserved for use for facilities like school, health centre, market, police outpost, milk booth, post office, power sub-station, transport terminal, water treatment plant, sewage treatment plant and the like. Such land shall abut a street having a width of not less than 10.00 metres. This shall be in addition to the land necessary for means of access and for open spaces mentioned in sub-regulation (3).