15.0 Regulations for Open Spaces for Buildings
(1) Generally:
(a) every room intended for human habitation shall abut an interior or exterior open space or an open verandah, open to such interior or exterior open space. Open spaces shall be areas forming integral parts of the plot at ground level and shall be open to the sky without any projection or overhang excepting cornices, chajjas or weather-shades of not more than 0.50 metre in width;
(b) every building shall have exterior open spaces comprising front open space, rear open space and side open spaces. The minimum width prescribed for front open space, rear open space and side open spaces shall be provided along the entire front, rear and side faces of the building respectively. For this purpose, the front of the building shall be that face of the building which faces the means of access of the building and the rear of a building shall be deemed to be that face of the building which is farthest from the means of access. These provisions shall also be applicable to each individual building when a plot contains more than one building. In the case of a corner plot located at the crossing of more than one street or passage, the rear of the building shall be deemed to be that face of the building which is farthest from the widest of all such streets and or passages;
(c) no building shall at any time be erected on any open space prescribed in these regulations for a building and from part of the site thereof, nor shall such open space be taken into account in determining the area of any open space required under these regulations for any other building;
(d) if the front open space is 3.00 metres or more, a “Gate Goomti” for security purpose may be allowed in the said open space. The covered area of such “Goomti” shall not in any case exceed 3.00 sq. metres and the height of such “Goomti” shall not exceed 3.00 metres. The covered area of the “Gate Goomti” shall not be included in the calculation of Floor Area Ratio (FAR) and Ground Coverage. For buildings exceeding the height of 14.50 metres, such “Gate Goomti” shall not obstruct the vehicular movement from the means of access to the side and rear open spaces;
(e) for erection or re-erection or addition to or alteration of any building exceeding 14.50 metres in height, the joint open space between such building and another building shall not be less than 7.00 metres. However, this rule shall not be applicable in case of a “Gate Goomti” construction;
(f) for the purpose of maintaining distance from overhead electric lines:
no building or verandah, balcony or projection in any building, shall be permitted to be erected or re-erected, added to or altered in any case where the distance between such construction and any overhead electric lines, in accordance with the provision of the Indian Electricity Act, 1910 (9 of 1910) and the rules framed thereunder, is less than as specified hereinafter:
| Vertical Clearance | Horizontal Clearance | |
|---|---|---|
| (i) Low and medium voltage lines including service lines | 2.5 m | 1.2 m |
| (ii) High voltage lines up to and including 11,000 volts | 3.7 m | 1.2 m |
| (iii) High voltage lines above 11,000 volts and up to and including 33,000 volts | 3.7 m | 2.0 m |
| (iv) For extra high voltage lines beyond 33,000 volts | 3.7 m plus 0.3 m for every additional 33,000 volts or parts thereof | 2.0m plus 0.3 m for every additional 33,000 volts or parts thereof |
Note: 'm' indicates metre.
(2) The minimum front open space shall be as follows:
A. For building not exceeding 14.50 metres in height
(a) every residential or educational building shall have a minimum front open space at ground level of 1.20 metres at its narrowest part;
(b) in the case of residential or educational building with other occupancy or occupancies covering more than 20% of the floor area at ground floor in the building, the minimum front open space at the ground level shall be 2.00 metres at its narrowest part, provided that for such building on plots with area 300.00 sq. metres or less, the minimum width of the front open space shall be 1.20 metres if the part of the building used for other occupancy or occupancies is not more than 30.00 sq. metres at the ground floor;
(c) every industrial or storage or hazardous or mercantile (wholesale) building shall have a minimum front open space at ground level of 5.00 metres at its narrowest part;
(d) in the case of industrial or storage or mercantile (retail) building on plot area of less than 300.00 sq. metres the minimum front open space shall be 1.20 metres at its narrowest part;
(e) every institutional or mercantile (retail) or business building shall have a minimum front open space at ground level of 3.00 metres at its narrowest part;
(f) every assembly building shall have a minimum front open space at ground level of 4.00 metres at its narrowest part;
(g) for mixed use buildings, the minimum front open space shall be the one applicable for that particular occupancy which gives the highest value of the minimum front open space;
(h) for plots in a scheme for Economically Weaker Section and Low Income Group Housing approved by Calcutta Metropolitan Development Authority the minimum front open space shall be as laid down in Chapter 19 of this Land Use and Development Control Plan.
B. For building exceeding 14.50 metres in height
(a) for every building there shall be a front open space of not less than 20% of the height of the building or 6.00 metres at its narrowest part whichever is less provided that such open space shall not be less than the open space specified in sub-rule (2) of this Land Use and Development Control Plan for that category to which the building belongs.
(3) The minimum rear open space shall be as follows:
(a) every building shall have a minimum rear open space at ground level of a width at its narrowest part of not less than that indicated below:
| Height of building (metres) | Minimum rear open space at its narrowest part (metres) |
|---|---|
| Up to 8.00 | 2.00 |
| Above 8.00 but not more than 11.00 | 3.00 |
| Above 11.00 but not more than 14.50 | 4.00 |
| Above 14.50 but not more than 18.00 | 5.00 |
| Above 18.00 but not more than 24.00 | 7.00 |
| Above 24.00 but not more than 50.00 | 10.00 |
| Above 50.00 | 12.00 |
(b) notwithstanding anything contained in clause (a) the minimum width of rear open space at it's narrowest part for industrial or storage or hazardous or mercantile (wholesale) building shall be 3.50 metres;
(c) for plots in a scheme for Economically Weaker Section and Low Income Group Housing approved by Calcutta Metropolitan Development Authority the minimum rear open space shall be as laid down in Chapter 19 of this Land Use and Development Control Plan.
(4) The minimum side open space shall be as follows:
(a) every building shall have minimum side open spaces at ground level of width at its narrowest part of not less than that indicated hereinafter:
| Height of building (metres) | Minimum side open space at ground level at its narrowest part (metres) | |
| Side 1 | Side 2 | |
| Up to 11.00 | 1.20 | 1.20 |
| Above 11.00 but not more than 14.50 | 1.20 | 2.50 |
| Above 14.50 but not more than 18.00 | 3.50 | 3.50 |
| Above 18.00 | 20% of the height of the building subject to a minimum of 5.50 | same as Side 1 |
(b) notwithstanding anything contained in clause (a) the minimum distance across the side open space from every new building to an existing building with a door or window opening shall be 1.80 metres for buildings not exceeding 14.50 metres in height;
(c) notwithstanding anything contained in clause (a) the minimum width of side open spaces for an industrial or storage or hazardous or mercantile (wholesale) building shall be 3.50 metres;
(d) in the case of a building more than 24.00 metres in depth on a plot, a passage along the entire depth of the building shall be provided and the minimum width of such passage shall be 4.00 metres;
(e) for plots in a scheme for Economically Weaker Section and Low Income Group Housing approved by the Calcutta Metropolitan Development Authority, the minimum side open space shall be as indicated in Chapter 19 of this Land Use and Development Control Plan.
(5) The interior open space shall be as follows:
(a) For inner courtyard
in case the whole of one side or part of at least two sides of every room excepting bath, water closets and store-room, is not abutting either the front, rear or side open spaces, it shall abut an inner courtyard whose minimum width shall be 30% of the height of the building or 3.00 metres whichever is more.
(b) For ventilation shaft
that is to say for ventilating water closet or bathroom such water closet or bathroom or kitchen or any room not intended for human habitation, if not opening on to front, rear, side or interior open space, shall open up to a ventilation shaft, the size of which shall not be less than the values given below:
| Height of building (metres) | Area of ventilation shaft (sq. metres) | Minimum width of shaft (metres) |
|---|---|---|
| Up to 11.00 | 1.50 | 1.00 |
| Above 11.00 but not more than 14.50 | 3.00 | 1.20 |
| Above 14.50 but not more than 18.00 | 6.00 | 2.40 |
| Above 18.00 | 8.00 | 2.40 |
for building of height above 30.00 metres a mechanical ventilation system shall be installed besides the provision of ventilation shaft.
Note: No chajja shall be allowed in the ventilation shaft unless the width of the shaft is 2.40 metres or more.
(c) For outer courtyard
the minimum width shall be 20% of the height of the building or 2.50 metres whichever is more.