14.0 Regulations for Height of Buildings
(1) Height of building shall be the vertical distance measured from the average level of the centre line of the adjoining street or passage on which the plot abuts to the highest point of the building, whether with flat roof or sloped roof.
(2) (a) The following appurtenant structures shall not be included in the height of the building: (i) Stair cover not exceeding 2.40 metres in height;
(ii) Lift machine rooms as per the latest edition of the National Building Code;
(iii) Roof tanks and their supports, the height of support not exceeding 1.00 metre;
(iv) Chimneys;
(v) Parapet walls not exceeding 1.50 metres in height;
(vi) Ventilating, airconditioning and other service equipments.
(b) The aggregate area of the structures mentioned in clause (a) shall not exceed one-third of the area of the roof upon which these are erected.
(3) The maximum permissible height of buildings on a plot shall be as given in the table below:
| Width of means of access in metres | Maximum permissible height in metres |
|---|---|
| (a) 2.4 to 3.50 | 8.00 |
| (b) Above 3.50 to 7.00 | 11.00 |
| (c) Above 7.00 to 10.00 | 14.50 |
| (d) Above 10.00 to 15.00 | 18.00 |
| (e) Above 15.00 to 20.00 | 24.00 |
| (f) Above 20.00 to 24.00 | 36.00 |
| (g) Above 24.00 | 1.5× (width of means of access + required width of front open space) |
(4) For plots in a scheme for Economically Weaker Section and Low Income Group Housing approved by the Calcutta Metropolitan Development Authority, the maximum permissible height of building shall be as laid down in Chapter 19 of this Land Use and Development Control Plan.
(5) For any building, to be erected or re-erected or added to which may affect the functioning of any microwave system for telecommunication purposes, the height of such building shall be governed by such rules or directions as may be made or issued in this behalf by the Central Government or any other concerned authority.