13.0 Regulations for Ground Coverage for Buildings
(1) The maximum permissible ground coverage for building when a plot contains a single building will depend on the plot size and use of the building as given in the table below:
Maximum Permissible Ground Coverage (Plot containing a single building)
| Use group of the building | Maximum permissible ground coverage for Development Control Zones | ||
| Development Control Zone 'C' | Development Control Zones other than Zone 'C' | ||
| A. | Residential and educational building: | ||
| (a) On plot size up to 200.00 sq. metres | 55% | 65% | |
| (b) On plot size of 500.00 sq. metres or more | 45% | 50% | |
| B. | Other use group including mixed use building | 40% | 40% |
(2) For a plot of size between 200.00 sq. metres and 500.00 sq. metres the maximum permissible ground coverage shall be calculated by direct interpolation of the values specified in the table at sub-rule (1).
(3) When a plot contains more than one building, the maximum permissible ground coverage for the buildings shall be as stipulated in Chapter 18 of this Land Use and Development Control Plan.
(4) For plots within a scheme for Economically Weaker Section and Low Income Group Housing approved by the Calcutta Metropolitan Development Authority the maximum permissible ground coverage shall be as laid down in Chapter 19 of this Land Use and Development Control Plan.