For plots in a scheme for Economically Weaker Section and Low Income Group Housing approved by Calcutta Metropolitan Development Authority the following regulations shall be applicable, provided that the size of the plot is not more than 65.00 sq. metres in area:
(1) (a) no building shall be allowed on a plot if the width of the means of access to the plot is less than 1.20 metres,
(b) no building exceeding 8.00 metres in height shall be allowed on a plot if the width of means of access to the plot is less than 3.50 metres;
(2) the maximum permissible ground coverage shall be 75% of the area of the plot;
(3) the maximum permissible height of the building shall be 10.00 metres;
(4) the minimum front open space shall be 0.80 metre;
(5) the minimum rear open space shall be 1.00 metre;
(6) the maximum permissible Floor Area Ratio shall be 1.75 metres;
(7) there shall be no need to provide side open spaces in the case of any such building, provided that the maximum aggregate length of such buildings in a row shall be 50.00 metres and after every 50.00 metres of length of such buildings in a row, there shall be an open space of not less than 2.50 metres in width for the entire depth of the building, and that such open space shall not be necessary if there is a street or passage at such location the minimum width of which is not less than 2.50 metres;
(8) there shall be no need to provide any car parking space within the plot;
(9) the size of rooms shall be as follows:
(a) Habitable room
the area of a habitable room shall not be less than 6.00 sq. metres with a minimum width of 2.40 metres. The habitable room for this purpose would be any room to be used for human habitation other than a kitchen, bath/water/closet, store/multi-purpose room;
(b) Kitchen
the area of kitchen shall not be less than 3.00 sq. metres with a minimum width of 1.50 metres;
(c) Water closet and bath room
the area of an independent water closet shall not be less than 0.80 sq. metre with a minimum width of 0.85 metre. The area of an independent bath room shall not be less than 0.80 sq. metre with a minimum width of 0.85 sq. metre. If water closet is combined with bath room its floor area shall not be less than 1.50 sq. metres with a minimum width of 0.90 metre.
(10) minimum height of rooms:
the height of all habitable and multi-purpose rooms shall not be less than 2.60 metres from the surface of the floor to the lowest point of the ceiling (bottom of the slab and/or beam). In the case of sloping roof, the average height of roof for habitable rooms shall not be less than 2.60 metres and the minimum height at eaves shall be 2.10 metres. The height of kitchen, bath/water closet and corridor/passage shall not be less than 2.10 metres measured from the surface of the floor to the lowest point of the ceiling (bottom of the slab and/or beam);
(11) excepting the provisions of clause (1) to (10) all other provisions of these regulations shall be applicable.