16.0 Regulations for Floor Area Ratio (F.A.R.)
16.1 Generally:
(i) When a plot contains one building the maximum permissible Floor Area Ratio shall be as given in the table.
(ii) The total covered area for calculation of F.A.R. shall consist of the areas of all the floors of all the buildings together with the circulation spaces including stair and lift areas, spaces for sanitary facilities and other ancillary areas within the building including the area of basement or cellar, the area of the mezzanine floors, the area of covered parking spaces, the area of walls, pillars and other structural members, the area of all the projections excepting projections for cornice, weather-shade and chajja of not more than 0.50 metre in width but shall not include the following:
(a) stair cover not exceeding 2.4 metres in height;
(b) lift machine rooms as per latest edition of the National Building Code;
(c) roof tanks and their supports, the height of support not exceeding 1.00 metre;
(d) chimneys, ventilating, air conditioning and service equipment attached to the building: Provided that aggregate area of these structures mentioned at (a) to (d) above shall not exceed one-third the area of the roof upon which these are erected;
(e) area of loft, ledge or tand;
(f) the area of covered car parking space as may have been provided for the required number of car parking spaces in accordance with Chapter 17 of this Land Use and Development Control Plan. For this calculation the area required for one car parking space is to be taken as 20.00 sq. metres inclusive of circulating spaces.
16.2 When a plot measuring 5,000 sq. metres or more contains more than one building the maximum permissible F.A.R. shall be as given in Chapter 18 of this Land Use and Development Control Plan.
16.3 The maximum permissible F.A.R. for a plot shall be on the basis of the width of the public or private street or passage that provides the means of access to the plot.
16.4 In case of re-erection of any existing building, the maximum permissible F.A.R. may be increased by 30% over the values permitted in this Land Use and Development Control Plan, subject to a ceiling of the present value of the F.A.R. of the existing building.
16.5 For plots in a scheme for Economically Weaker Section and Low Income Group Housing approved by Calcutta Metropolitan Development Authority the maximum permissible F.A.R. shall be as indicated in Chapter 19 of this Land Use and Development Control Plan.
TABLE
MAXIMUM PERMISSIBLE FLOOR AREA RATIO
| Width of the means of access (in metres) | Use groups of the buildings | ||||||
| Residential buildings | Educational buildings | Industrial hazardous & storage buildings | Other buildings including mixed use buildings | ||||
| Development Control Zones 'C' | Other Development Control Zones | Development Control Zones 'C' | Other Development Control Zones | In the Development Control Zones where such buildings are not prohibited | Development Control Zones 'C' | Other Development Control Zones | |
| (i) 1.20 to less than 2.40 | 0.75 | 1.00 | Nil | Nil | Nil | Nil | Nil |
| (ii) 2.40 to 3.50 | 1.00 | 1.25 | Nil | Nil | Nil | Nil | Nil |
| (iii) Above 3.50 to 7.00 | 1.50 | 1.75 | Nil | Nil | Nil | Nil | Nil |
| (iv) Above 7.00 to 10.00 | 1.75 | 2.00 | 1.75 | 2.00 | Nil | Nil | Nil |
| (v) Above 10.00 to 15.00 | 2.00 | 2.25 | 2.00 | 2.25 | 2.00 | 1.75 | 2.00 |
| (vi) Above 15.00 to 20.00 | 2.25 | 2.50 | 2.25 | 2.50 | 2.00 | 2.00 | 2.25 |
| (vii) Above 20.00 to 24.00 | 2.50 | 2.75 | 2.50 | 2.75 | 2.00 | 2.25 | 2.50 |
| (viii) Above 24.00 | 2.75 | 3.00 | 2.75 | 3.00 | 2.00 | 2.50 | 2.75 |