18.0 Regulations for Control of Development of Plot Containing More Than One Building
(1) (a) every building on a plot containing more than one building shall abut an internal road connecting the means of access of the plot. The F.A.R. shall be calculated on the basis of the width of the means of access on which the plots abuts.
(b) the minimum width of such internal roads shall not be less than 3.50 metres, where internal road of 3.50 metres of width is not possible to be provided due to an existing building constructed prior to the enforcement of this Land Use and Development Control Plan, a building of not more than 7.00 metres in height may be allowed, provided that the width of the internal road shall not be less than 1.20 metres.
(c) the maximum permissible height of any building on a plot shall be determined by the width of the means of access on which the plot abuts according to the table given in sub-regulation (3) Chapter 14 of this Land Use and Development Control Plan.
(d) the minimum width and the maximum length of all such internal roads shall be as prescribed in the table in sub-regulation (2) of Chapter 22 of this Land Use and Development Control Plan.
(e) in case the buildings within a plot are not of the same occupancy, an individual building of any particular occupancy shall comply with the regulations governing such occupancy except the provisions regarding Ground Coverage and Floor Area Ratio which shall be in accordance with sub-regulations (2) and (4) of this regulation.
(2) Ground Coverage shall be as laid down below:
(a) for plots measuring less than 5,000 sq. metres in area, the maximum permissible ground coverage shall be the values prescribed in Chapter 13 of this Land Use and Development Control Plan if the buildings are of same occupancy. If the buildings are not of same occupancy then the ground coverage shall be 40%.
(b) for plots measuring 5,000 sq. metres or more in area, the maximum permissible ground coverage shall be 40% for buildings with same occupancy and 35% for buildings with different occupancies including mixed use occupancy.
(3) Open spaces for buildings shall be as laid down below:
every building shall have minimum external open space as prescribed in Chapter 15, provided that on these open spaces internal roads may be constructed.
(4) Floor Area Ratio (F.A.R.) shall be laid down below:
(a) for plots measuring less than 5,000 sq. metres in area the maximum permissible F.A.R. for buildings of same occupancy shall be the value for that particular occupancy prescribed in Chapter 16 and for buildings with different occupancies shall be the value for that particular occupancy which gives the lowest value prescribed in Chapter 16.
(b) for plots measuring 5,000 sq. metres or more, the maximum permissible F.A.R. for buildings with same occupancy shall be reduced by 10% from the value for that particular occupancy prescribed in Chapter 16 and for buildings with different occupancies including mixed use occupancy shall be reduced by 10% from the lowest value for these occupancies as prescribed in Chapter 16.
(5) Parking:
The provision shall be the same as stipulated in Chapter 17 of this Land Use and Development Control Plan.