17.1 Staircase
17.1.1 If the lifts and staircase from higher floors go directly to the basement then this area shall be protected by 1 hour fire resistance construction including fire doors subject to opinion and requirement of local fire authority in specially designed building have to be considered and observed.
17.1.2 Staircase: For above 15 meters up to 25 meters height (excluding parapet wall, lift and stair cabin, OH tank)
17.1.3 Width of staircase: 1.5 meter clear inside to inside
17.1.4 If a centrally located staircase is provided with pressurization and fire-resistant doors, the central staircase shall be in addition to the ventilated staircases require for the floor area, maintaining the travel distance.
17.2 Electrical duct
Electrical duct should have sealed metal doors with metal frame or fire rated doors at each floor level. Opening of the duct shall be from basement to terrace level.
17.3 Hollow plinth
Hollow plinth parking shall be protected with sprinklers as per Indian standard IS 15105.
17.4 Margins
All margins shall be as per CGDCR.
17.5 Ramp
Ramps shall be provided as per CGDCR.