(a) All counterweight sections (filler weights), metal or non-metal shall be carried in a single frame. Means shall be provided to retain counterweight sections in place and prevent displacement. In case of non-metallic filler weights, the counterweight sections shall be totally enclosed in a metallic covering. Where tie rods are used, minimum of two shall be provided, passing through all sections. The factor of
safety of steel frame members and the tie rods shall not be less than 5.
(b) If pulleys are fixed to the counterweight, they shall be provided with device to avoid,—
(i) the suspension ropes, if slack, leaving the grooves and
(ii) the introduction of objects between ropes and grooves.
The devices shall be so constructed as not to hinder inspection or maintenance of the pulleys.
(c) Counterweights shall withstand the effect of buffer impact.
(d) At least four replaceable guide shoes with renewable lining or set of roller guides shall be provided, two at the top and two at the bottom of counterweight.
- Guides .—(a) The guides of the lift-car and the counter-weight shall be rigid and shall be of steel except where the nature of the processes carried on the building renders such material unsuitable due to acid-fumes or similar cause.
(b) In case of lift working at a speed exceeding 0.4 meter per second, special’ Lift T Section Guides’ only shall be used and they shall be joined by means of machined spigot and socket joints or other adequate means.
(c) Guides shall be continuous throughout the entire length of the lift-well, and shall be provided with adequate iron or steel brackets or equivalent fixings of such design and spacing so that the guides shall not deflect more than (6mm) under normal operation.
(d) If the guides are attached to overhanging stairs, the method of fixing shall be such that no vertical stress is transferred from the guides to the stairs.
(e) Guides shall be of such length that it will not be possible for any of the car or counter-weight guide shoes to run off guides.
(f) Guide brackets and shims if and shall be of steel and shall not be directly supported and fastened to the lift-well enclosure wall unless such wall is of such construction and strength as to adequately withstand the thrust imposed on the guides under all conditions of the
lift-service. The fastenings shall be by means of bond blocks built into the Walt or expansion bolts or through bolts with metal plates of such thickness and size as to adequately distribute the load on the wall.
(g) Guides and their fixings shall withstand the application of the safety gear when stopping a fully loaded lift-car or the counter-weight if provided with a safety gear.