- Lift-well.—(a) All lift-wells intended for the reception of lifts shall be exclusively reserved for that purpose and shall not be used for any other purpose.
(b) Lift-well and all equipments and apparatus fixed therein shall be rendered fire-proof to the greatest possible extent.
(c) The inner surface of the lift-well and its enclosure facing any lift-car entrance shall, so far as practicable, be kept smooth and flush devoid of projections or recesses. Where any projections or tops of the recesses cannot be rendered flush, they shall be levelled on the underside to an angle of not less than 60 degrees from the horizontal, by means of metal plates, cement rendering or other fire-resisting materials.
(d) Where a lift-car leveling device is operative with lift-car gate open, such interior surfaces shall always form a smooth and flush surface below each landing level.
(e) Sufficient space shall be provided between the guides for the car and the side-walls or the lift-well enclosure to allow safe and easy access to the parts of the safety gear for their maintenance and repairs.
(f) In the case of a lift-well which is common to more than one lift and where the lift-car or the counter-weight of one lift is working in juxtaposition to the lift-car or the counter-weight of another lift, such liftcars or counter-weights shall be guarded carefully and adequately in order to protect persons working in the lift-well or on the lift-cars from accidental contact with such cars or counter-weights in any part of their travel.
(g) In case of a completely enclosed lift-well a notice with the word ‘Lift’ shall be placed on the outside of each landing door.
(h) It is undesirable that any room, passage or throughfare be permitted under any lift well. If unavoidable then the pit floor should be strong enough to withstand the impact of free falling loaded car and counter weight.
- Lift-well enclosure.—(a) Lift-wells and wells for the counter-weight if located independently of the lift-well shall be adequately protected by means of suitable enclosure work which shall be extended on all sides from floor to ceiling.
(b) In all counter-weight wells located Independently of the main lift- well, suitable access shall be provided for the inspection, maintenance and repairs to counter-weights, wire ropes and their anchorages, guides and guide supports.
(c) All such doors giving access to such counter-weight well shall be provided with electro-mechanical locking devices.
(d) Where wire grill or similar construction is used, the mesh or opening shall be such that the opening between the bars shall reject the ball of 30 mm in diameter and the lift well enclosure shall be of sufficient strength to resist accidental impact by users of the staircase of adjoining floors or by materials or trucks being moved in the vicinity.
(e) Where the clearance between the inside of an open type lift well enclosure and any moving or movable part of the lift equipment or apparatus is less than 5 cm, the opening in the enclosure shall be further protected by netting of square mesh or aperture not greater than 1 cm and of wire not smaller than 1mm (the provision in this clause need not be adhered to for lift wells in factory premises, coming under the purview of Factories Act. In such cases provision mentioned in clause (d) is sufficient.
(f) No counter-weight shall be allowed to travel in any lift-well or part of any lift-well other than that to which it belongs.
(g) On every passenger lift, there shall be provided at each floor, a floor position indicator or ‘IN USE’ indicator or direction call registering light.
(h) Glass shall not be used for lift-well enclosure.
(i) The distance between the lift-well enclosure on the sides facing any lift-car entrance and the sill edge of the car shall not be more than 30mm in the landing zone below the landing gate. If such distance is more than 30 mm in the lift-well enclosure, the same shall be finished with suitable and smooth plaster work or facia plates so as to make the surface thereof devoid of all projections and recesses. In case the enclosure wall on the sides facing the lift-car entrance is more than 13 cms. from the sill edge of the lift-car platform, the lift-car door of such lift shall be provided with means to prevent it from being opened except when the lift-car is at the landing served by such car entrance.
(j) The distance between the edge of any landing sill and the sill of the car platform shall not be more than 25mm.
(k) No automatic fire door or shutter which operates by means of a fusible link or otherwise due to the action of heat, shall be allowed in any landing, opening or the lift-way enclosure of any lift, if such opening gives access to any exit from the building.
(l) The walls enclosing lift-well in the buildings having height more than 24 meters shall have fire resistance of not less than two hours. The liftwell shall have permanent vents immediately under the machine room not less than 0.2 Sqm. in clear area.
(m) The lift-well for fire lift (a lift to enable fire brigade personnel to get to the upper floors with the minimum delay and to be used exclusively by firm in an emergency and directly accessible to every landing on every floor), in the buildings having more than 24 meters height, shall be segregated from the other lift-well by means of brick masonry or RCC wall of a fire resistance of not less than two hours.
- Lift-pits.—(a) Lift-pits shall be soundly constructed and maintained in a dry and clean condition. Where necessary, provision shall be made for permanent drainage.
(i) Spring or oil buffers shall be provided for lift and counter- weight;
(ii) the lift-pit shall be made sufficiently strong to withstand successfully the impact of the lift-car with the rated load or the impact of the counter-weight when descending at the rated speed or at the governor tripping speed; and
(iii) the car and the counter-weight shall be provided with a governor operated safety gear.
- (1) Top car clearance.—The top car clearance shall be sufficient to avoid any protruding part fixed on the top of the Car coming in direct contact with the ceiling or diverting sheave. The clearance shall be calculated taking into account the following and shall not be less than the sum of the following four items:—
(a) The bottom counterweight run by.
(b) The stroke of the counterweight buffer used.
(c) The dimensions of the portion of the diverting sheave hanging underneath the ceiling in the lift well, and
(d) 15 cm for compensating for gravity stopping distance and future repairs to the rope connections at counterweight and at the car or at the suspension points.
(2) Bottom car clearance.—The bottom car clearance shall be maintained in such a way that the counterweight shall not come in contact with the ceiling or any part hanging underneath the ceiling, when the car completely rests on fully compressed buffers, provided the buffers are spring type mounted on solid concrete or steel bed. In case of wooden buffers the bottom car clearance shall be maintained in such a way that the total downward travel of the car from the service level of the immediate floor near the pit, shall not be more than; the top counterweight clearance, when the wooden buffers are completely crushed.
(3) Top counterweight clearance.—The top clearance for the counterweight can be calculated taking into account the following and shall not be less than the sum of the following three items:—
(a) Car runby.
(b) Compression of the buffer spring or height of the wooden block used as buffer and
(c) 15 cm to compensate for gravity stopping distance for counterweight and any future repairs to rope connections at the counterweight at the car ends or at the suspension points.
- (1) Landing doors.—The landing doors shall be imperforated;
(a) Special Case: - Goods lifts used in industrial premises may use collapsible doors or vertically sliding landing doors. The collapsible type landing doors shall be of a close picket type and no openings exceeding 5.5 cm in width shall be permitted between the vertical members of the doors when they are fully extended.
(b) The distance between the lift-well side of the car door and the lift well side of the landing door shall not exceed 13 cm; where the car door or the landing door consists of two or more panels, the 13 cm dimensions shall apply to the door panel nearest to the side edge. The distance between the car and the landing sills shall not exceed 30mm.
(c) The opening for the landing doors shall not be wider than that of the width of lift car. Minimum landing door opening width and height shall be 0.7 m and 2 m respectively.
(d) The landing doors shall be securely fixed.
(e) The landing gates or doors which are self-closing shall be equipped with safety devices preventing injury by trapping persons while entering or leaving the lift-car.
(f) All landing gates and doors and their tracks shall be capable of withstanding a thrust of (34kg) applied normally at any point excepting the vision panels, without causing permanent deformation or without being sprung from their guides.
(g) (i) Where the landing doors are solid and are manually operated and no indicators are provided either near the landing door or inside the lift-car, each of such doors shall be provided with a vision panel.
(ii) Where the vision panel is provided with glass, such glass shall be fire-resistant and safety-wired.
(iii) Any projection on or recess ( including vision panels) in any sliding door shall be kept to the minimum so as to avoid finger trapping between the sliding part of the door and any fixed part of any structure.
(h) For the lifts in buildings having height of more than 24 meters.
(i) the landing doors shall have fire resistance of not less than one hour; and
(ii) the landing door for fire lifts shall be power operated, automatic closing and opening type, and the words ’FIRE LIFT’ shall conspicuously be displayed in radium paint on lift landing doors on each floor.
- Locking devices for landing gates and doors.—(a) Every landing gate or door shall be fitted with an electro-mechanical locking device which shall comply with the appropriate requirements given hereinafter.
(b) (i) It should not be possible to open the landing gate or door from the landing side until the lift-car is within that particular landing zone. Provision shall be made for the opening of the gate or door in case of emergency by means of a special key, which shall be kept in a secured position.
(ii) It should not be possible to start the lift-car or keep it in motion unless all the landing gates or doors are locked in closed position.
Exception,—Where lift-car leveling device is provided, it is permitted to move the lift-car with the lift-car gates or doors and landing gates or doors open within the landing zone.
Note:— (i) The door shall be considered closed and the lift-car may be moved away from the landings when the door is within (58mm) of the jamb, or in the case of centre opening doors, when these are within (58mm) of each other, provided an approved attachment is fitted which will effectively prevent the doors from being reopened after they have reached a limit of (58mm) and provided also that the door closer is of such a type as will eventually carry the door or doors to and lock it or them in the closed position.
(ii) The electrical and mechanical part of all locking devices shall be of sub-station design and construction. The removal of any inspection cover or covers shall not affect the operation of a device. All locking devices shall be fixed securely to the enclosure by suitable means.
(iii) The locking devices for landing gates or doors shall be so designed that the lock contact is not closed until the gate or door is locked.
(iv) Any springs used in the locking device shall be in compression and properly supported.
(v) The contacts of the locking device shall be of solid and sturdy construction and shall be opened positively and the functioning of the interlock to prevent movement of the lift-car shall not be solely dependent on the action of a spring or springs, nor solely upon gravity, nor upon the closing of an electric circuit.
(vi) The design shall be such that reasonable wear and tear of working parts shall not create an unsafe condition or permit interference with the operation of the lift by movement of the gate or door or its fittings.
(vii) The conduct carrying the conductors to the lock or contract boxes shall be fixed securely to the boxes and shall maintain electrical and mechanical continuity.
(viii) The locking device together with the actuating rods or levers shall be protected from interference from the landing side of the lift-well enclosure.
(ix) Provision shall be made on all lifts for device to prevent the opening of any landing gate or door while the lift-car is passing through a landing zone to another floor.
- Car.—(a) Lift cars shall be enclosed on all sides by means of car body and doors or gates and such enclosures shall be at least 2m clear in height. A roof solid or perforated, capable of supporting 2 persons, that is, 2 x 68 kg shall be provided. Perforations shall be sufficiently close in mesh and shall reject a ball of 25mm diameter to provide reasonable protection against falling articles on any person traveling in the car. The car floor shall be of a flat non-slip surface or chequered surface.
(b) Each lift car shall be fixed with a light which shall be left burning during the whole time the lift is available for use.
(c) Where car leveling devices are used, substantial aprons of sufficient depth shall be fitted to the car floor to ensure that no space more than the running clearances are permitted between the threshold and the landing while the car is being levelled to the floor.
(d) Where the lift car has solid enclosure and doors, provisions shall be made for a fan and for adequate ventilation. To permit switching off the power supply to the lift without switching off the fan and light, a separate circuit with control in machine room shall be provided for fan and light. Ventilation openings shall be provided in the enclosure above 1.8 m level and below 0.3m level. The total area of openings shall be not less than 0.035 Sqm for each square meter of area of the car floor divided suitably between the top and the bottom levels. Any openings provided by a ventilating fan may be regarded as forming part of the ventilation area in that part of the car in which it is fitted.
(e) The car enclosure and doors, including their tracks of every lift car shall withstand a thrust of 345 N applied normally at any point, excepting any vision panel, without permanent deformation.
(f) A three-pin plug socket with switch for a hand lamp shall be fitted on top of the lift car for use by persons working thereon.
(g) Lift car platforms shall be of framed construction and designed on the basis of rated loads evenly distributed. Platforms for goods cars shall be designed to suit the particular condition of loading. The minimum factor of safety shall be 5 for steel and 8 for timber.
(h) Glass shall not be used in lift car except for the following purposes:—
(a) As covers for certificates.
(b) For lighting fixtures.
(c) For appliances used in connection with the operation of car, and
(d) For vision panels and mirrors.
However, conditions may be relaxed in case of specially designed, well protected, fully transparent, laminated type glass for capsule type construction only.
(i) Every lift car with solid enclosure and doors shall be provided with battery operated emergency light and emergency alarm. The lighting shall automatically come on in case of failure of normal lighting supply.
(j) Emergency stopping device in car operating panel for automatically operated lifts with imperforated doors is prohibited. However, goods lifts in industrial premises where entrances are fitted with perforated doors in conformity with 15.2.1 of IS 14665(Part 4/Sec.6) car operating panel shall be provided with emergency stopping device operated by a push button in the car and it shall be clearly marked in red.
(k) An alarm button, yellow in colour, shall be provided on the car operating panel.
- Car-frame.—(a)General Requirements.—
(i) Every passenger and goods lift suspended by wire ropes shall have a car frame.
(ii) Where the car frame is under slung or located entirely below the car platform, the vertical centre distance between the top and bottom guide shoes shall not be less than 40 percent of the distance between guide rails.
(iii) Where the platform is supported directly by the plank or by sound isolation frame, fixed to the plank, the vertical centre distance between guides shoes shall not be less than the distance between guide rails.
(b) Materials.—Materials used in the construction of car frame shall conform to the following:—
(i) Car frame shall be made of steel or any other metal.
(ii) Cast iron shall not be used for any parts subjected to tension or bending except guiding supports, guide shoes and anchorages for compensating chain and rope.
(iii) Steel used shall be rolled, formed or forged or cast.
(iv) Metals other than steel may be used in the construction of car frames, provided the metal used has the essential properties to meet all the requirements for the purpose in accordance with good engineering practices.
(c) Car frame connection.- Connections between members of car frame shall be riveted, bolted or welded. Bolts and nuts when used through greater than 5 sloping flanges of structural members shall seat on taper washer.
(d) Suspension Rope Hitch plates.-Suspension ropes attached to the car shall be attached to steel hitch plates or to structural steel shapes. If attachment is by bolts or rivets, the plates or shapes shall be secured to the underside or the webs of the car frame member with bolts, rivets or by welding, so located that tension in the suspension ropes does not develop direct tension in the bolts, rivets or weldment.
(e) Car frame with Crosshead Sheaves.—
(i) Sheaves Mounted on Car frame.- Where a suspension rope sheave or sheaves are mounted on the car frame and the sheave shaft extends through the web of carframe members, the reduction-area of the member shall not reduce the strength of the member. Where necessary, reinforcing plates shall be welded or riveted to the member to provide the required strength.
(ii) Multiplying Sheaves Mounted on Separate Sheave Shafts.- Where multiplying sheaves mounted on separate sheave shaft
are used, provision shall be made to take the compressive forces developed due to tension in the suspension ropes between the sheaves, on a strut or struts between sheave shaft supports or by providing additional compressive strength in the carframe or carframe member supporting the sheave shaft.
(iii) Sheave Mounted on Crosshead by Means of Single threaded Rod .- Where the sheave is mounted on crosshead by means of single threaded rod or specially designed member or members in tension, the following requirements shall apply:—
(a) The single rod member or members shall have a factor of safety of 50 percent higher than the factor of safety required for the suspension wire ropes, but in no case shall have a factor of safety less than 15.
(b) The means of listening the single threaded rod member or members of the carframe shall conform to 8(g).
(f) Attachments to Carframe.—Where side bracing and similar members are attached to the carframe, the reduction in area of the carframe due to attachments of the member shall not reduce the strength of the carframe below the limit for which it is designed.
-
Lift-car capacity.—The contract load in relation to the lift-car floor area shall not be less than the figures shown in graphs 1 and 1 A.
-
Load to be marked in lift-cars.—(a) There shall be marked conspicuously in every lift-car the maximum number of persons (calculated at 68 Kg.) per person) which it can safely carry. Persons in excess of the said limit shall not be carried in the lift-car.
(b) For goods lift the load shall be given in pounds and also in persons calculated at 68 Kg. per person.