No. PBW-B (3)-1/2007.—In exercise of the powers conferred by section 15 of the Himachal Pradesh Lifts Act, 2007, the Governor, Himachal Pradesh is pleased to make the following rules, namely:—
-
Short title.—(1) These rules may be called the Himachal Pradesh Lifts Rules, 2009.
-
Definitions.—In these rules, unless the context otherwise requires,—
(i) ‘Act’ means the Himachal Pradesh Lifts Act, 2007;
(ii) ‘bottom car runby’ means the distance between the car buffer striker plate and the striking surface of the buffer when the car is in level with the bottom terminal landing;
(iii) ‘bottom clearance’ means the clear vertical distance from the floor of the lift-pit to the lowest structural or mechanical part, equipment or device installed beneath the car-platform, except the guide shoes, rollers, safety jaw blocks and platform apron or guard located within three hundred millimeters measured horizontally from the sides of the car platform when the car rests on its fully compressed buffers;
(iv) 'bottom counter-weight runby’ means the distance between the counter-weight buffer striker plate and the striking surface of the counterweight buffer when the car floor is in level within the top terminal landing;
(v) ‘buffer’ means a device designed to stop a descending car or counterweight beyond its normal limit of travel by storing or by absorbing and dissipating the kinetic energy of the car or counterweight ;
(vi) ‘call indicator’ means a visual and audible device in the car to indicate to the attendant the lift landing from which calls have been made;
(vii) ‘car’ or ‘lift-car’ means the load carrying unit with its floor or platform, car frame and enclosing body work ;
(viii) ‘car apron’, or ‘landing apron’ means a protective screen attached to the under-side of the car-platform or lift landing, as the case may be, to prevent an object from being trapped between the car-platform and the lift-landing;
(ix) ‘car enclosure’ means the enclosing body work of the lift-car which comprises the sides and roof and is built upon the car-platform;
(x) ‘car-floor’ or ‘car-platform’ means that part of the lift-car which forms the floor and directly supports the load;
(xi) ‘car-frame’ means the supporting frame or sling to which the carplatform, safety gear, guide shoes and suspension ropes are attached;
(xii) ‘car levelling device’ means an automatic device designed to cause the lift-car to move at a reduced speed within a limited Zone and to stop substantially level with the lift-landing, independently of varying loads;
(xiii) ‘car switch control’ means a method of control whereby the movement of the lift-car is directly under the control of the lift operator by means of a switch in the lift car;
(xiv) ‘contract load’ means the load specified in the approved plans and Form’A’.
(xv) ‘contract speed’ means the speed specified in the approved plans and Form’A’ and equivalent to the means of maximum speeds attained by the lift in any part of its travel in the up and down directions, with contract load in the lift car;
(xvi) ‘control equipment’ means the components of a lift by means of which motion, direction of travel, speed and stopping are controlled;
(xvii) ‘controller’. means a device or group of devices comprising the principal components of control equipment;
(xviii) ‘counter-weight’ means a weight or series of weights to counter balance the weight of the lift-car or part of the load thereof;
(xix) ‘drum drive’ means a method of transmitting power to the suspension ropes by means of a winding drum;
(xx) ‘dual control’ means a method of alternative automatic or car-switch control, so arranged that either may be used but not both at the same time;
(xxi) ‘electro-mechanical brake’ means a brake consisting of friction shoes applied to a break drum by means of springs or weights and released electrically ;.
(xxii) ‘emergency stop switch’ means a device designed to cut off power to the control circuit to cause the lift-car to stop;
(xxiii) ‘final or ultimate limit switch’ means an emergency stop switch designed to stop the lift-car in the event of excessive over-travel;
(xxiv) ‘flexible guide clamp safety gear’ means a safety gear in which the action on the guides is effected by means of rollers or cams applied gradually in an emergency;
(xxv) ‘floor selector’ means a mechanism which forms part of the control equipment in certain automatic lifts and is designed to operate controls which cause the lift-car to stop at the required floor;
(xxvi) ‘Form’ means a form appended to these rules;
(xxvii) ‘gate-closer’ or ‘door closer’ means a device which closes a gate or door, as the case may be, automatically;
(xxviii) ‘gate lock’ or ‘door lock’ means a lock for application to a lift-landing or lift-car door or gate, as the case may be, and so designed that the door or gate, as the case may be , may only be opened when the liftcar is in the landing zone or by a special key;
(xxix) ‘gate-operator’ or ‘door-operator’ means a power operated device for opening and closing gates or doors, as the case may be;
(xxx) ‘gate switch’, ‘gate contact door’, or ‘switch door contact’ means a switch operated by the movement of a gate or door, as the case may be;
(xxxi) 'governor tripping speed’ means the speed at which a lift-car speed governor trips ;
(xxxii) 'gradual wedge clamp safety gear’ means a safety gear in which the action on the guides is effected by a screw and wedge or similar device applied gradually in an emergency;
(xxxiii) ‘guides rails’ means the members used to guide the movement of the lift-car or counter-weight;
(xxxiv) ‘guide bracket’ means the part of a guide fixing which carries the guide seating or guide clips and bolts and serves to secure them to the building or structure;
(xxxv) ‘guide fixing’ means an assembly of parts comprising a guide bracket carrying a guide-seating or guide clips and bolts and serving to secure a car guide or counter-weight guide to the building or structure;
(xxxvi) 'guide shoes’ means an attachment to the car-frame or counterweight for the purpose of guiding the lift-car or counter-weight;
(xxxvii) ‘independent counter-weight’ means a counter-weight intended to balance part of the weight of the lift-car and supported independently of the lift machine;
(xxxviii) 'instantaneous safety gear’ means a mechanical device in which the action on the guides is effected by means of serrated rollers or cams applied instantaneously in an emergency;’
(xxxix) ‘landing gate’ or landing door’ means a hinged or sliding portion of a lift-well enclosure controlling access to the lift-car at a lift-landing;
(XL) ‘landing zone’ means a space extending from a horizontal plane 40 cm below a landing to a plane 40 cm above the landing.
(XLI) ‘lift pit’ means the space in the lift-well below the level of the lowest lift-landing served;
(XLII) 'lift-well ‘ means the unobstructed space within a lift-well enclosure provided for the vertical movement of a lift-car and any counter-weight including the lift-pit and the space for top clearance;
(XLIII) 'lift-well enclosure’ means any structure which separates the lift-well from its surroundings;
(XLIV) 'moveable floor’ means a lift-car floor or platform arranged to operate a switch under the influence of the weight thereon;
(XLV) 'normal terminal limit’ means a switch arranged to open the control circuit and to stop the lift-car automatically within the limits over-travel;
(XLVI) 'over speed governor’ means an automatic device which brings the lift-car or counter-weight to rest by operating the safety gear in the event of the speed in a descending direction exceeding a pre-determined limit ;
(XLVII) ‘safety gear’ means a mechanical device attached to the car-frame or counter-weight to stop and to hold the lift-car or counter-weight to the guides in the event of free fall or if governor operated or over speed in the descending direction;
(XLVIII) 'SCHEDULE’ means the schedule appended to these rules;
(XLIX) 'section’ means a section of the Act;
(L) ’slack rope switch’ means a device incorporating a switch used in a drum-driven lift for automatically cutting off the power to the control circuit in case all or any of the suspension ropes becomes slack;
(LI) ‘top clearance’ means the shortest vertical distance between the top of the car crosshead or, where no car crosshead is provided, between the top of the car and the nearest part of the overhead structure or any other obstruction when the car floor is in level with the top terminal landing;
(LII) ‘top over-travel’ means the distance provided for the car-floor to travel above the level of the top lift-landing when the lift-car is stopped by the normal terminal stopping device;
(LIII) 'traction drive’ or ‘V-sheave drive’ means a method of transmitting power to the suspension ropes by means of a sheave;
(LIV) 'trailing cable’ means a flexible cable providing electrical connection between the lift-car and a fixed point or points;
(LV) 'travel’ means the distance between the bottom and top lift-landings served; and
(LVI) 'winding drum’ means a drum forming part of a lift machine round which the suspension ropes are wound and to which they are attached.
- Permission for installing lift or for making additions or alterations to lift already installed.—Every owner of a place intending,—
(1) to install a lift in such place; or
(2) to make additions or alterations to a lift installed at any place, shall make an application in Form ‘A’ to the officer authorised by the State Government under section 3 of the Act before any work in connection with the installation of the lift or addition or alteration thereto is started. Every such application shall be accompanied by two sets of plans of the installation or as the case may be, of the additions and alterations and by a declaration from the contractor to whom the applicant proposes to entrust the work of installing the lift or, as the case may be, of additions and alterations thereto;
(3) On receipt of an application under sub-rule (1), the officer authorised under section 3 of the Act, shall after making such enquiries and requiring the applicant to furnish such information; as he may deem necessary, forward the application with his remarks to Chief Engineer (Elect.), Himachal Pradesh Public Works Department Shimla( HP) or the officer authorised by him in this behalf under section 3 (2) of the Act, as the case may be, who may thereupon, either grant or refuse the permission applied for.
- Licence for working lift.—(1) Every owner of a place who is permitted to install a lift under rule 3 shall, within one month after the lift is installed, deliver, or send or cause to be delivered or sent to the officer authorised by the Chief Engineer (Elect.), Himachal Pradesh Public Works Department, Shimla ( HP) under sub- section (1) of section 4 (1), a notice in writing of such installation, and shall make an application to him for a licence for working the lift. The notice and the application shall be in Form ‘B’ which shall be accompanied by a certificate from the contractor who has installed the lift.
(2) On receipt of an application under sub-rule (1) the officer authorised by the Chief Engineer (Elect.),Himachal Pradesh Public Works Department Shimla (HP) under section 4 (1) of the Act, shall, after making such enquiries as he may deem necessary, forward the application with his remarks to the Chief Engineer (Elect.), Himachal Pradesh Public Works Department Shimla (HP) or officer authorised by him under section 4 ( 3 ) of the Act, as the case may be, who may, subject to the provisions of rule 5, either grant or refuse the licence. The licence shall be granted/ issued in Form’C'.
-
Terms and conditions for granting of licence.—No licence for working a lift shall be granted, unless the requirements laid down in the SCHEDULE have been complied with in respect of the lift and its installation.
-
Every application under section 5 for granting a licence for the working of a lift installed before the commencement of the Act shall be made in Form 'D'.
-
Terms on which lifts shall be worked.- Every lift shall be worked subject to the following terms:—
(i) The licencee shall maintain the lift and its installation in accordance with the requirements laid down in the SCHEDULE.
(ii) The licencee or his authorized agent or any other aggrieved person shall forthwith report to the Executive Engineer (Elect.) Himachal Pradesh, Public Works Department / Inspector of lifts for any defect in the working of the lift.
(iii) The licencee shall not carry out any additions or alteration to a lift installation without obtaining permission in that behalf under rule 3 of these rules.
(iv) The licencee shall not use or cause the lift to be used which is not in a safe working condition.
(v) Unless the licencee, in the opinion of the Chief Engineer (Elect.) or Superintending Engineer (Elect.), Himachal Pradesh, Public Works Department, as the case may be, has suitable means for the satisfactory maintenance of the lift, the licencee shall entrust the maintenance of the lift and its installation either to an approved manufacturer of lifts or an approved agent of such manufacturer of lifts or to an approved firm or company of electrical and mechanical engineers of at least five years standing.
Explanation.—For the purposes of this clause, ‘approved’ means approved by the Chief Engineer(Elect.), Himachal Pradesh Public Works Department or Superintending Engineer (Elect.), Himachal Pradesh Public Works Department, Shimla (HP), as the case may be.
(vi) Every person, firm or company entrusted with the maintenance of the lift and its installation under clause (v) above shall properly actuate all the safety devices while the lift is in use and report to the owner of the lift immediately, if any defect is found in the installation.
(vii) If any part, enclosure, gate or fastening of a lift is damaged or broken, the licencee shall immediately report and put it in good working order. He shall keep the safety gears in good order and all parts of the lift and safety gear clean and free from rubbish, dust or dirt. The licencee shall not weld any broken or damaged parts which are subject to tension, torsion or bending or parts on which the lift-car is supported.
(viii) The “licencee” shall forthwith replace all controlling, lifting and balance weight ropes which indicate excessive wear, splintering, stranding or bunching.
(ix) The “licencee” shall enter every repair and alteration to the lift in a log book, which shall be maintained in each lift installation.
(x) The “licencee” shall remedy every fault in the lift installation reported by the lift-operator, immediately.
(xi) The “licencee” shall see that the following work is carried out by his contractor at least once a month and the result entered in the log book by the contractor, namely:—
(a) Cleaning and lubricating the guides,
(b) Examining the ropes and their attachments.
(c) Examining the safety devices.
(d) Examining and lubricating the door locks.
(e) Lubricating all moving parts,
(f) Examining the worm and the gear.
(xii) Whenever the lift is out of order, the licencee shall see that all the landing gates or doors are securely locked and the users of the lift are informed by a notice pasted at any conspicuous place at each floor that the lift is out of order.
(xiii) No person shall willfully interfere with any mechanism of the lift installation.
(xiv) No person below the age of 18 years shall be engaged as a lift operator. The lift operator shall be having lift operator training or holding a licence to operate the lift.
-
Notice of accidents.—Notice of accident required to be given under section 10 of the Act shall be in Form ‘E’ and such notice shall be given within 24 hours of the occurrence of the accident.
-
Unused lifts.—When a lift installed at any place ceases to be used as such the owner shall either remove it or maintain it in safe mechanical condition after disconnecting it entirely from the electric supply. All gates and doors shall be securely locked so as to prevent the entry of unauthorized persons to the lift -well.
-
Manner of payment of fees under section 4(1) and 11(1).—The fees payable under section 4(1) and section 11(1) of the Act shall be paid,
(a) into the appropriate Government Treasury, to the credit of the Chief Engineer (Electrical) or Superintending Engineer (Electrical), Himachal Pradesh, Public Works Department by challan in triplicate, the receipt in duplicate being forwarded to the Chief Engineer, (Elect.) or Superintending Engineer (Elect.) Himachal Pradesh, Public Works Department as the case may be, by the Treasury Officer direct; or
(b) at the office of the Chief Engineer,(Elect.) or Superintending Engineer (Elect), Himachal Pradesh, Public Works Department, as the case may be, in cash or by money order or through a Bank Draft or crossed cheque payable at a local Scheduled Bank in favour of Chief Engineer(Electrical) or Superintending Engineer (Elect.) Himachal Pradesh, Public Works Department Shimla (HP).