The quality of life in any urban centre depends upon the availability of and accessibility to quality social infrastructure. Social infrastructure can be looked at in terms of the facilities indicated in the City Level Master Plan, and Community Facilities, which are indicated at the layout plan level in various use zones. Together, these include social infrastructure facilities pertaining to health, education, sports facilities, sociocultural activities, communications, security and safety, and other community facilities pertaining to recreation, religious activities, social congregations and community events, cremation / burial grounds etc. These are generally planned in terms of population norms with stipulated permissibility conditions and development controls.
Annexure 12(I) Street Design Regulations
Based on the overall Mobility, Safety and Environmental Goals for the City, the following Regulations must be followed for design, execution, management and maintenance of all Roads:
1. To Promote Preferable Public Transport Use:
1A. Streets should be Retrofit for equal or higher priority for Public Transit and Pedestrians.
1B. Prohibit street parking or enforce high parking charges for private vehicles on public streets and spaces, in order to encourage use of other modes.
1C. Provide dedicated lanes for high occupancy vehicles (HOVs) and carpool during peak hours.
1D. Provide transit-oriented mixed landuse patterns and redensify city within walking distance of MRTS stops, wherever permissible.
2. For Safety of All Road Uses by Design:
2A. Limit speed by design on urban arterial roads and sub-arterial streets to 50 kmph and on collector and local streets to 30 kmph. Street design should be used as a means of limiting speed where possible aided by enforcement in the case of higher speed limit.
2B. Traffic calming of all streets with ROW of 12 m or less, through narrowing of driveway and meandering path with use of trees, islands and street furniture. Speed should be limited to 20 km/hr by design.
2C. Maximum kerb height shall not exceed 150 mm, as higher kerbs are difficult to climb for pedestrians causing them to walk on carriageways. Higher kerbs are also dangerous for speeding vehicles during off-peak hours as they may cause overturning of vehicles, accidents, etc.
Final road level should be fixed for all streets in the city. When repaving roads, previous layers must be scraped such that final road level remains the same.
Footpath level should never be more than 150 mm above adjoining carriageway level.
2D. Intermittent buffers, bollards and other physical elements should be used to protect footpaths from encroachment by motor vehicle parking. However, such elements should not form a barrier, such as continuous railings, that constrain
access to pedestrians. Active enforcement is required to protect encroachment of footpaths.
2E. Corner radius of Kerb should not exceed 12 m, in order to control speeding of vehicles at blind turns and intersections, causing accidents. No slip roads or free left turns should be provided on Collector or Local Streets. In case slip roads or turning pockets are provided on Arterial roads, safe at-grade pedestrian crossings with traffic calming and signal should be provided.
2F. Multi-Utility Zone (MUZ) of minimum 1.8 m width should be provided on all Collector and Arterial Roads, to accommodate bus stops, street utilities, trees, street furniture, planting for storm water management; IPT/NMT stands, paid idle parking, etc. so that these don’t encroach upon the carriageway or safe pedestrian movement spaces.
2G. Secure parking facilities and services for cyclists/ NMT should be provided on all Collector and Arterial Roads.
2H. Provide Accessible Public Toilets at every 500-800 M distance – preferably located close to bus stops for easy access by pedestrians and public transport users.
3. For Pedestrian Safety, Comfort and Convenience on All Streets:
3A. Pedestrians should remain at ground level with comfortable and safe access and minimum detours from the most direct path, unless there is no other alternative.
3B. A continuous unobstructed footpath on each side of all streets with ROW wider than 12m. Minimum width of footpath should be 1.8 m (with clear height 2.4 m.) in addition to space for trees/greenery/vending spaces and surface utilities. Width of footpath shall be determined based on pedestrian volume and have to be wider than 1.8 m wherever required.
3C. Frontage Zone or Dead Width: For sidewalks in shopping areas, an extra 1 m should be added to the footpath width. In residential areas, a dead width of 0.5 m may be added.
3D. On streets with ROW of 18 m or less, if pedestrian traffic is greater than 8000 per hour in both directions together, the entire ROW should be notified for pedestrianization. Streets may be considered for pedestrianization even if pedestrian traffic is lower than 8000 per hour depending on the potential to improve economic activity and/or safety and convenience.
3E. Elevation of footpaths over the carriageway at all times should be <150 mm and adequate cross slope for storm water runoff. The elevation should be low enough for pedestrians to step onto and off of the footpath easily.
3F. All facilities and amenities should be barrier free for universal access by all persons with reduced mobility including those with hearing and visual impairments.
3G. At least 5 safe Street-Level Crossing Opportunities per kilometer of street with 250 m being maximum spacing between two crossings. Depending on context, these crossings may be signalized and/or traffic calmed (through raising crosswalk over street level by 150 mm) to reduce vehicular speed.
Pedestrian refuge with a minimum width of 1 m at each street crossing location after crossing 7 m of one way motor vehicle carriageway or 10 m of two way motor vehicle carriageway at non signalized midblock crossings. Pedestrian refuge width may be expanded to 1.75 m where possible to accommodate a bicycle.
Grade separated structures (foot-overbridges and pedestrian-subways) should be avoided to prevent unnecessary detours to reach destinations.
If grade-separated pedestrian crossings are unavoidable due to presence of highways in peripheral zones of urban areas, then such crossings structures should be frequent. There must be at least 4 crossing opportunities per kilometer in areas with development at edges. Every crossing should be universally accessible.
3H. Natural Surveillance or “eyes on the street” should be enabled on all roads by removing setbacks and boundary walls and building to the edge of the street ROW, wherever permitted as per norms. This would allow people from inside to look out on to the pavement, thus discouraging harassment of women on footpaths, bus-stops and public spaces.
4. For climatic comfort for all Road Users:
4A. Trees are an essential component for all streets – to provide shade to pedestrians/cyclists and reduce solar gain.
At least 125 trees per km for streets with ROW smaller than 12 m. At least 125 trees per km per footpath on streets with ROW greater than 12 m. Spacing of trees at no place should be greater than 12 m except at intersections.
4B. High albedo (diffuse reflectivity) materials should be used for paving to reduce urban heat island effect.
4C. Built to Pavement Edge Buildings with overhangs and arcades provide good protection to pedestrians.
5. To ensure universal accessibility and amenities for all street users:
5A. All facilities and amenities should be barrier free for universal access by all persons with reduced mobility including those with hearing and visual impairments, as per Codes.
5B. Continuous barrier free pavement should be provided for ease of movement for elderly/ persons with disabilities. Pavement height of the footpath should be maintained at a constant level of 150 mm all along the ROW, for proper provision of table-tops / ramps, etc. at various locations such as entry to properties, crossings, etc.
5C. Provide at-grade crosswalks (and foot-over-bridges on highways or BRT corridors) at intervals of approx.70-250 M, aligning with location of transit stops, type of street / landuse activities and neighbouring building entries and destinations.
5D. Provide Accessible Public Toilets should be provided every 500-800 M distance, preferably located close to bus stops for easy access by pedestrians and public transport users.
6. To reduce Urban Heat Island Effect and Aid Natural Storm Water Management:
6A. Decrease impervious surfaces through permeable paving, tree planting zones, etc. to increase ground water infiltration & prevent seasonal flooding.
6B. Integrate Natural Storm Water filtration and absorption into street design through bio-filtration beds, swales and detention ponds.
6C. Decrease Heat Island Effect (HIE) by increasing greenery, planting trees, using reflective paving, etc.
7. Intermediate Public Transport:
Intermediate Public Transport (IPT) are hired / shared modes of transport that may serve as feeders to trunk public transport systems or as another alternative to private transport use. IPT includes cycle-rickshaws, auto-rickshaws, e-rickshaws, taxis and any other vehicle type serving as a shared mode / feeder service that is also prescribed under the Motor Vehicle Act. Taxis play an important role in providing an integrated transport service which should also be available on road like all other metro cities for people who choose not to use a car and combine taxi with public transport for certain trips. Auto-rickshaws also play an essential role as a shared or hired mode of public transport which provide door-to-door connectivity for a variety of trips and provide an affordable alternative to private modes. Adequate space for IPT, Bus, private bus, truck and commercial parking must be provided on all Layout Plans.
8. Definition of Mass Rapid Transit System (MRTS):
Mass Rapid Transit System (MRTS) may be defined as any public transit system having the capacity to carry more than 10,000 peak hour peak direction trips (PHPDT).
Annexure- 12.0 (II)
Sub Regional Transport Network Plan for Delhi
Legend
NCT Delhi Boundary Major Roads (60M & above R/W) Major Roads (45M & above R/W) Major Roads (30M & above R/W) Railway Line RRTS &Stations (Approved in 36th GBM dated 10.412) MRTS Ph- I & II MRTS Ph- III MRTS Ph- IV (Proposed) MRTS (Proposed) Monorail (Proposed) Integrated Transport Corridor/BRTS Integrated Transport Corridor/BRTS (Proposed) Integrated Passenger Terminal Interstate Bus Terminal Integrated Freight Terminal Proposed Inter-State Roads (60M & above R/W)
The capital city is strategically located and has many specialised health facilities, which serve the city population as well as that of the region, and in many respects the country as a whole. As per available statistics, there are 23 types of health units (facilities) in Delhi. The total numbers of health units are 1914 and the number of beds is 30,667. The existing bed density per thousand population in Delhi works out to only 2.2. The World Health Organization (WHO) has recommended a norm of 5 beds per thousand population. It is estimated that the total number of beds required in the year 2021 will be about 1,15,000.
The following broad strategies are proposed in order to meet the requirements of health related infrastructure:
i. Shortfall in the availability of number of beds per 1000 population is proposed to be met through-
a) Enhancement in FAR for various levels of health facilities;
b) Promoting rebuilding of the existing old hospitals and;
Shifting of contagious diseases hospitals from existing urban areas to the proposed urban extension with proper seclusion facilities and connectivity, and using the space thus made available for general hospitals.
ii. Essential provisions shall be made for Old Age Home-cum-Care Centres for Senior Citizens and Mentally Challenged by way of specialised / target group oriented facilities, which will also relieve the pressure on general hospitals to some extent.
iii. Premises earmarked for health facilities should also include other medical streams like Ayurvedic / Homeopathic medicine, governed by any statutory code / body.
iv. Complementary health facilities at par should be developed in the NCR to reduce burden on Delhi.
There shall be following 1[.] health facilities for the city population:
i. 2[Hospitals category:
a) Hospital (category of hospital shall be governed by number of beds, which shall be regulated with respect to maximum permissible FAR and area per bed is 80 sqm.)
b) Tertiary Health Care Centre;
c)] Other health facilities, which include maternity home, nursing home, family welfare centre, polyclinic, paediatrics centre, geriatric centre, diagnostic centre, etc.
ii. For health care of animals and pets the following 3 tier of health facilities has been proposed:
Veterinary Hospitals for pet / domestic animals and birds shall be provided as per need.
b) Dispensary for pet animals and birds shall be provided in all the zones at Community Level.
c) Pet clinic is permitted in all landuse zones except in Recreational use zone.
3[Table 13.1: Planning Norms and Standards for Health Facilities
Sl. No.
Category
Population / Unit
Plot Area (approx.)
123456
Hospital Tertiary Health Care Centre Other Health Facilities a. i. Maternity Home ii. Nursing Home/ Polyclinic iii. Dispensary b. i. Family Welfare Centre ii. Pediatric Centre iii. Geriatric Centre iv. Diagnostic Centre. a. Veterinary Hospital for pet animals and birds b. Dispensary for pet animals and birds
5.0 lakh 2.5 lakh 1.00 lakh 1.00 lakh 1 per 50000 1 per 50000 1 per 10000 1 each per500001 per 5.0 lakh 1 per 1.0 lakh
2.5 ha to 4.5 ha 1.5 ha to 2.5 ha 0.2 ha. to 1.5 ha.* 0.2 ha. to 1.5 ha. ] 1000 sqm to 2000 sqm 1000 sqm to 2000 sqm 800 sqm to 1200 sqm 500 sqm to 800 sqm each 2000 sq m. (Subject to availability of land) 300 sq m.
1 Deleted vide S.O. 2893(E) dated 23-09-2013
2 Modified vide S.O. 2893(E) dated 23-09-2013
3 Modified vide S.O. 2893(E) dated 23-09-2013
Sl. No.
Category
Population / Unit
Plot Area (approx.)
7
a. Medical College b. Nursing and Paramedic Institute c. Veterinary Institute
1 per 10 lakh 1 per 10 lakh As per requirement
As per norms of Medical Council of India / Regulatory Body (subject to availability of land) 2000 sqm (Subject to Nursing Council of India / Ministry of Health norms). As per the Veterinary Council of India / Ministry norms (subject to availability of land)
1[Note:
* Size of hospital plot will be restricted up to 1.5 ha. in residential area, with preference to plot having three side open and having minimum 18m ROW on one side. Total floor area of the hospital shall be governed as per the total number of beds allowed in it.]
Table 13.2Development Controls for Health Facilities
Sl. No.
Category
Maximum
Other Controls
Ground Coverage
FAR
Height
2[1]
3[Hospital / Tertiary Health Care Centre
Ground coverage to be decided by interse building to building distances as per Building Bye Laws and fire tender movement requirements, subject to a maximum40%excluding 5% additional ground coverage for multi-level parking
FAR on plot facing ROW should be subject to NOC from all concerned agencies depending on locations shall be as under.
No height restriction subject to clearance from AAI, DFS, DMA, NMA. NBC to process the proposed revision of NBC as soon as possible. Till the time the NBC is revised, Delhi Fire Services (DFS) may allow no restriction of height for health care
1. Upto 25% of the permitted FAR can be utilized for residential use of essential staff, dormitory/ hostel for attendants of the patients, Crèche etc. 2. Parking standard @ 2.0 ECS/100 Sqm of floor area. 3.Maximum 10% ground coverage shall be allowed for providing atrium*. In case, the permissible additional ground coverage for atrium is utilized 25% of the utilized ground coverage
a. RoW less than 24m
250
b. RoW 24M upto 30M
300
c. RoW 30M and above
375
For plots falling under Influence Zones of MRTS/ Major Transport
1 Added vide S.O. 2893(E) dated 23-09-2013
2 Modified vide S.O. 3173(E) dated 12-12-2014
3 Modified vide S.O. 2893(E) dated 23-09-2013
Sl. No.
Category
Maximum
Other Controls
Ground Coverage
FAR
Height
Corridors such as Metro and BRT Corridors, 50% more FAR should be available.
facilities with commensura te fire and life safety measures, subject to clearance from AAI, DFS,DMA, NMA and other statutory provisions.
shall be counted toward FAR 4.Multi Level Podium parking shall be permissible to the extent of building envelope lines, free from FAR and ground coverage to facilitate ample parking in spaces, subject to structural safety. 5.1[Maximum 10% of the achieved FAR shall be free if utilized for waiting & reception area. However, this area shall be taken into account for the provision of hospital parking as per norms. ] 6. Service floor of height 1.8m shall not be counted In FAR.]
2[2]
Other Health Facilities a. i. Maternity Home ii. Nursing Home / Polyclinic / Dispensary b. i. Family Welfare Centre ii. Paediatric Centre iii. Geriatric Centre
30%
150
26 m
Parking standard @ 2.0 ECS/ 100 sqm of floor area.
1 Added vide S.O. 2689(E) dated 11-08-2016
2 Modified vide S.O. 3173(E) dated 12-12-2014
Sl. No.
Category
Maximum
Other Controls
Ground Coverage
FAR
Height
iv. Diagnostic Centre
1[3]
a. Veterinary Hospital for pet animals and birds
30%
150
26 m
Parking standard @ 1.33 ECS/ 100 sqm of floor area. Parking standard @ 1.33 ECS/ 100 sqm of floor area.
b. Dispensary for pet animals and birds
35%
100
26 m
1[4]
a. Medical College
As per norms of Medical Council of India / Regulatory Body
b. Nursing and Paramedic Institute
30%
150
26 m
Parking standard @ 2 ECS/ 100 sqm of floor area.
c. Veterinary Institute
As per the Veterinary Council of India / Ministry norms
1[*] Natural sky light condition is exempted for Atrium and construction over the Atrium may be allowed.
Height restriction of 30 mts. in Hospital Buildings should be reviewed in consultation with Fire Deptt. of GNCTD]
Plot area for all ² [Hospital/ Tertiary Health Care Centre would be worked out @ 80 sqm] of gross floor area per bed. However, for other health facilities like Maternity / Nursing homes, family Welfare and other centres, the plot area would be worked out @ 60 sqm of gross floor area per bed.
Max. upto 300 sqm of floor area shall be allowed to be used for community space / religious shrine / crèche / chemist shop/bank counter on Hospital sites and also Medical College / Nursing and Paramedic Institutes sites.
Other controls:
a. In case of super specialty medical facilities / hospitals duly certified as such by the competent authority, the gross area shall be worked out @ upto ³[80] sqm per bed.
b. In case of existing premises / sites, the enhanced FAR shall be permitted, subject to payment of charges as may be prescribed by the Authority / land owning agency and other clearances.
c. ⁴ [Basement after utilization for Parking; Services Requirements such as air conditioning plant and equipment, water storage, boiler, electric sub-station, HT &
¹ Added vide S.O. 2893(E) dated 23-09-2013
2-4 Modified vide S.O. 2893(E) dated 23-09-2013
LT panel rooms, transformer compartment, control room, pump house, generator room; staff locker room, staff changing room, staff dining facilities without kitchen facility, Central sterile supply deptt., back end office; Other Mechanical Services; Installation of Electrical and fire fighting equipments; and Other Services like kitchen, laundry and radiology lab and other essential services required for the maintenance/functioning of the building may be used for healthcare facilities with prior approval of the concerned agencies.]
d. Other controls related to basements etc. are given in the Development Code chapter.
1[e. The bed count of a Health Facility may be allowed as per permissible FAR, needs of the community and demand studies.
f. Environment clearances shall be made mandatory considering that bio wastes are generated. Environmental clearances are mandatory as per the prevailing regulations related to the environment.
g. Zero discharge for sewerage shall be enforced at the cost of the promoters and post treatment water can be used by premises for its needs of horticulture, flushing, coolant tower, washing or disposal to other construction sites. These issues concerned the local bodies and can be dealt accordingly as per existing regulations at the time of sanctioning the plan.
h. The additional power requirements shall be met by power supply from grid and till such time by means of suitable captive generation.]
13.2Education
The literacy rate in Delhi has increased from 75.3% in the year 1991 to 81.82% in the year 2001. In overall terms Delhi has a fairly elaborate network of educational institutions from the pre-primary / primary to the higher education and professional education levels. At present there are 2416 primary schools, 755 middle schools, and 1576 secondary / senior secondary schools. At the higher/ professional education levels, there are 114 colleges for general education, 8 engineering colleges, 4 universities, 7 deemed universities and one Open University.
However, there is a deficiency in few planning zones, particularly in the field of school education. Further, keeping in view the fast changing national and global economic scenario, the employment and educational requirements are also undergoing a rapid change involving the development of new professional and vocational avenues for specialised education. A number of coaching centres, computer training institutes and language / training classes are opening up. However, these are mainly operated by the private sector. Suitable provision for
1 Added vide S.O. 2893(E) dated 23-09-2013
such centres in commercial areas is desirable with a view to enhancing the financial resources of the concerned land owning agency.
With the consequent potential for availability of financial resources for this purpose, involvement of the private sector in the development of educational facilities is growing.
Keeping the need for expansion and diversification as brought out above, the availability of land could become a major constraining factor. It has, therefore, become necessary to develop policies and norms, which would enable optimal utilisation of land and available educational infrastructure. As far as school education is concerned, the policy should be geared to encourage integrated schools from the pre-primary to the higher secondary level, rather than allocating space separately for Nursery Schools, Primary Schools and Middle Schools. Primary Schools may specifically be set up by the Delhi Government or the Local Civic Bodies.
Following planning policy parameters are proposed:
i. Differential norms and standards for various educational institutes / institutions shall be applicable in the light of the norms of the concerned controlling authorities e.g. University Grants Commission (UGC) / All India Council for Technical Education (AICTE) / Directorate of Education, GNCTD / Central Board of Secondary Education (CBSE) etc.
ii. Coaching centres / vocational training centres would be permissible in school classes after school hours with (a) prior approval of Competent Authority in the case of schools run by GNCTD or local body and (b) with prior intimation to lessor and payment of fee to be prescribed in the case of schools run privately on leased land. Structured courses leading directly to degree / diploma shall however not be permitted.
iii. The educational institution premises may be permitted to function in two shifts, subject to statutory approvals and any other conditions that may be stipulated by the relevant competent authority.
iv. Nursery School may function as part of Primary School / Secondary School / Senior Secondary School, wherever needed. Separate / exclusive Nursery Schools are permitted in residential premises as per the Mixed-use policy.
v. Requirement of schools and training centres for mentally and 1[differently abled persons] with differential development norms are given.
1-6 Modified vide S.O. 2895(E) dated 23-09-2013
7 Modified vide S.O. 3491 (E) dated 21-11-2016
Table 13.3Planning Norms and Standards for Education Facilities
Sl. No.
Category
Population / unit (approx.)
Plot Area
1
Primary School
10,000
7[ 0.2 ha
2
Sr. Secondary School 2[/ Secondary School]
10,000
0.4 - 0.8 ha]
3
School for Mentally challenged
10.0 lakh
0.2 ha
4
School for 3[differently abled persons]
10.0 lakh
0.2 ha
Table 13.4Development Controls for Education Facilities
Sl.No.
Category
Maximum
Other Controls
Gr.Cov.
FAR
Height
1
Play School, Coaching Centre, Computer-Training Institute, physical Education Centre etc.
N.A.
N.A.
N.A.
1. Practice of providing dedicated Nursery School plots in the layout plan discontinued as same is permissible in mixed use. Parking standard @ 1.33 ECS / 100 sq m of floor area.
2
Nursery School
33.33%
100
15 m
2. In case of schools for mentally 4[ challenged / differently abled persons] 20% of max. FAR can be utilized for residential use of essential staff and student accommodation.
3
Primary school
30%
120
18 m
4
Sr. Secondary School 5[/Secondary School]
35%
150
18 m
5
School for Mentally challenged
50%
120
18 m
Parking standard:- Primary School / Middle School @ 1.33 ECS / 100 sq m of floor area.
6
School for 6[differently abled persons]
50%
120
18 m
- Sr. Sec. School @ 2.00 ECS / 100 sq m of floor area.The areas earmarked for parking if misused, liable to be municipalized / taken over.3. Other controls related to basements etc. are given in the Development Code chapter.
Notes:
Pre-Primary Schools / Nursery Schools / Montessary Schools / Creche, Play Schools, are permissible in residential use premises as per Mixed use policy.
Other Controls:
In case of new schools, the front boundary wall shall be recessed by 6 m to accommodate visitors parking within setback area.
Upto 10% variation in plot size is permitted. Differential norms will be applicable to Special Area, Regularized Unauthorized Colonies, Urban Villages and Resettlement Colonies.
Playground shall be developed on pool basis in different areas at neighborhood level.
Table 13.5Planning Norms and Standards for Education Facilities (Higher Education)
Sl. No.
Category
Pop./ unit (approx.)
Plot Area
1234
Vocational Training Centre(ITI/ Polytechnic / Vocational Training Institute/ Management Institute/ Teacher Training Institute etc.), Research and Development centre General College Professional College (Technical) University Campus including International Education Centre (IEC) - Large campus (10 ha and above) will be divided into following four parts: a) Academic including Administration (45% of total land area). b) Residential (25% of total land area). c) Sports and Cultural activities (15% of total land area). d) Parks and Landscape (15% of total land area).
0.4 ha As per UGC norms As per the AICTE norms. Upto 20.0 ha
Upto 10% variation in plot size is permitted.
Table 13.6Development Controls for Education Facilities (Higher Education)
Sl. No.
Category
Maximum
Other Controls
Ground Coverage
FAR
Height
123
Vocational Training Centre (ITI/Polytechnic / Vocational/ Training Institute/ Management Institute/ Teacher Training Institutes etc.) / Research and Development centre. General College Professional College (Technical)
35%
1[225]
37 m
1. 2[Upto 30% of max. permissible FAR can be used for hostel accommodation for the students.] 2. Parking standard @ 1.33 ECS / 100 sq m of floor area. The areas earmarked for parking if misused liable to be municipalized / taken over by the authority. 3. Other controls related to basements etc. are given in the Development Code chapter.
1-2Modified vide S.O. 2895(E) dated 23-09-2013
13.4Communications - Post / Telegraph / Telephone Facility
With liberalisation and technological advancement, communication has become very important medium of accessibility. Following means of communication are available:
13.4.1 Post and Telegraph
Post and Telegraph is one of the most popular means of communication. The provision and management of Post and Telegraph facility in Delhi is the responsibility of Post Master General of Delhi Circle. At present Delhi has 553 post offices and 36 telegraph offices. Although, the number of telegraph offices is decreasing due to availability of other easier, cheaper and faster modes of communication these facilities still serve considerable population both at the city level and National level. The future space norms have been worked out accordingly.
13.4.2 Telephone
With privatisation of tele-communication sector most of the space requirement is expected to be satisfied in private sector. There are 267 telephone exchanges in Delhi with provision of 140 lakh connections, which works out to be 145 connections per thousand population. The introduction of mobile telephony has completely transformed the telecommunication system in the city. Therefore, the future space requirement for telephone network has been worked out accordingly.
Table 13.8Planning Norms and Standards for Communication Facilities
Sl. No.
Category
Population / Unit (approx)
Plot Area
A.
POST & TELEGRAPH
1
a) Post Office Counter (without delivery) b) Courier Service Office
1. No specific site reservation to be kept in the layout plan. 2. Permitted in all use / zones / under mixed use as per requirement except in Recreational use zone.
1. No specific site reservation to be kept in the layout plan. 2. Permitted in all use / zones / under mixed use as per requirement except in Recreational use zone.
2
Telegraph office (Booking & Delivery)
1. No specific site reservation to be kept in the layout plan. 2. Permitted in all use / zones / under mixed use as per requirement except in Recreational use zone.
1. No specific site reservation to be kept in the layout plan. 2. Permitted in all use / zones / under mixed use as per requirement except in Recreational use zone.
3
Head Post Office with Administrative office & with / without delivery office.
10.0 lakh
2500 sq m.
B
TELEPHONE
Sl. No.
Category
Population / Unit (approx)
Plot Area
4.
a) Telephone Exchange b) RSU (Remote Subscriber Units)
10.0 lakh 1 for 3 Km radius
2500 sq m. 300 sqm.
<sup>1</sup>[5.
Media & News Agency including Media Centre
10 lakh
As per Requirement]
Upto 10% variation in plot size is permitted.
Table 13.9Development Controls for Communication Facilities
Sl. No.
Category
Maximum
Other Controls
Ground Coverage
FAR
Height
A
POST & TELEGRAPH
1
a) Post Office Counter (without delivery) b) Courier Service Office
No specific site reservation to be kept in the layout plan since permitted in all use zones / under mixed use as per requirement, except in Recreational use zone
2
Telegraph office (Booking & Delivery)
3
Head Post Office with Administrative office & with / without delivery office
30%
120
26 m
1. Upto 15% of max. FAR can be utilized for residential use of essential staff. 2. Parking standard @ 1.33 ECS / 100 sq m of floor area. 3. Other controls related to basements etc. are given in the Development Code chapter.
B
TELEPHONE
4
a) Telephone Exchange
30%
120
26 m
b) RSU (Remote Subscriber Units)
30%
100
15 m
2[5
Media & News Agency including Media Training Centre
35%
150
26
Upto 30% max. Permissible. FAR can be used for hostel accommodation for
1 Added vide S.O. 465(E) dated 15-02-2016
2 Added vide S.O. 465(E) dated 15-02-2016
Sl. No.
Category
Maximum
Other Controls
Ground Coverage
FAR
Height
the students and residential use for essential staff. 2. Parking standard @ 1.33 ECS / 100sqm of floor area. The areas earmarked for parking if misused liable to be municipalized/take n over by the authority. 3. Other controls related to basement etc. are given in the Development Code chapter.]
13.3Sports Facilities
Delhi is emerging as an important centre for National and International Sports events. Sizeable sports facilities have been developed in the City by various agencies like the Sports Authority of India (SAI), Delhi Development Authority (DDA), GNCTD, etc. However, sports activities, so far, been dealt with as a part of Recreational use. It is also felt that many of the facilities, which have been developed, could actually be seen as recreation and / or club type of facilities. As a result, even though the DDA has developed a large network of excellent sports facilities, over and above the facilities developed by the SAI, etc. there is an evident need for a properly planned and structured sports infrastructure in the city which, inter alia, should also be able to take care of mega / international sporting events, such as the forthcoming Commonwealth Games in 2010.
Even the various facilities, which have been developed as pure sports facilities, suffer from lack of full and proper utilisation, and there are issues related to maintenance and resources for the same. With reference to the latter, for example, the Jawahar Lal Nehru Stadium premises are, on the one hand, presently under use for a variety of non-sports related activities and on the other hand, the Stadium itself cannot be used for anything but sports activities. The latter aspect, in turn, is characterised by gross under utilisation. This also brings out the need for developing and prescribing planning and development control norms geared to planned, practical and proper development of sports facilities as an important component of social development and optimum utilisation of the facilities to be developed.
In addition to the above, there is a trend for development of gyms, spas, bowling alleys etc. at neighbourhood level. Since these are mostly being established as commercial ventures, provision of land / space for these should be made in commercial premises.
13.3.1 Provision of Sports Facilities
Sports activities are an important part of physical and social development of an individual and, at another level sports activities have a significant aspect of, and potential in the form of congregational and competitive events at the community, city, national and international levels. Keeping this in view norms and space standards separately for sports facilities at neighbourhood level and city level have been proposed with the aim of development of sports and play areas for all age groups at appropriate levels.
Table 13.7Planning Norms and Standards for Sports Facilities
Sl. No.
Category
Pop. / Unit (Approx.)
Plot Area (Ha.)*
1
Divisional Sports Centre / Golf Course
10 lakh
10 to 30 & above
2
District Sports <sup>1</sup>[ Complex]
5 lakh
3 to 10
3
Community Sports Centre
1 lakh
1 to 3
4
Neighborhood Play area
10,000
0.5 to 1
5
Housing Area Play Ground
5,000
0.5
* Subject to availability of land.
i. The sports facilities shall be developed according to proper layout plan and landscape plan with adequate parking facility.
ii. The existing sports infrastructure shall be upgraded and efficiently replanned to provide better facilities.
iii. New play fields shall be preferably provided / developed in the vicinity of educational institutions and landscape areas.
iv. The playground and sports facilities should be accessible by a network of pedestrian and cycle tracks wherever feasible.
2[v. Multi-gyms would be permissible in parks having an area of one ha. and would have built up area upto 225 sq.m.]
13.3.2 International Sports Events
Suitable area of about 200 ha. shall be reserved for International Sports events wherever possible.
13.3.3 Development Controls
The development controls for the various sports facilities will be as indicated below:
Maximum ground coverage
20% including amenity structures
Max. FAR
40
Height
NR (Subject to clearance from AAI, Fire Dept. and other statutory bodies).
Parking
2 ECS/ 100 sqm of floor area.
Other Development Controls:
i. To incentivise development of sports facilities and swimming pool (upto maximum 100 sqm) within the group housing areas, schools, clubs, etc. shall not be counted towards ground coverage and FAR.
ii. All these various sports facilities shall have layout plan, landscape plan, and parking plan, etc.
1 Modified vide S.O. 2890(E) dated 23-09-2013 and S.O. 149(E) dated 20-01-2014
2 Added vide S.O. 2890(E) dated 23-09-2013
13.5Security- Police
Law and order are increasingly becoming a matter of concern in Delhi. For maintenance of proper law and order, the security force must keep pace with the growth and development of an area. The main agency looking after security aspect in the city is Delhi Police. At present, there are 123 police stations, 80 police posts, 10 Delhi Armed Police battalions, 9 District offices of DCPs and 9 District Lines.
1[Table 13.10: Planning Standards & Development Controls for Public Semi-Public (Government Use Premises)
Sl. No.
Category
Pop. / unit (approx.)
Plot Area
Maximum Ground Coverage(%)
FAR**
Parking(ECS/100Sq.m Floor Area)
1
Traffic and Police control room
As per requirement
1. As per requirement on major road junctions/ stretches etc. as part of road right of way based on site feasibility. 2. Maximum area = 25 sq m.
N.A.
1 Added vide S.O. 2790(E) dated 24-08-2016
Sl. No.
Category
Pop. / unit (approx.)
Plot Area
Maximum Ground Coverage(%)
FAR**
Parking(ECS/100Sq.m Floor Area)
2
Police Outpost
As per requirement, Permissible in all use premises/ zone, and to be provided in schemes as per requirement.
Upto150sq.m
75
300
1.33
3
Police Post, Fire Post.
1.0 lakh
Upto2500sq.m
50
300
2. 0
4
Police Station, Fire Station
2.5 lakh
Upto 1 Ha.
50
300
2. 0
5
Police Lines, District Office and Battalion
District / One for each administrative zone
Upto 1 Ha.
50
300
2. 0
6
District Jail
25.0 lakh
Upto 2 Ha.
50
300
2. 0
7
Police Training Institute / College, Fire Training Institute / College, Police Firing Range, Police camp including Central Police Organization / Security Forces, Disaster Management Centre
City level
Upto 5 Ha.
50
300
2. 0
Other Controls:
** The maximum FAR for Use Premises located in Zone O, and Bungalow Area of Zone C & Zone D, will be 120, along with other provisions given in Zonal Development Plans.
i. Residential Use – Maximum up to 30% of permissible FAR can be utilized for residential activities. The activities permitted within residential component shall be as per Residential Plot - Group Housing.
ii. Height – No Restriction, subject to clearance from AAI, Delhi Fire Service and other statutory bodies.
iii. Other controls for setbacks, basement, services plans etc. as per Chapter 17.0 Development Code.
iv. For intensive utilization of existing government buildings / land, as mentioned in para 8.2 following will be applicable in case of redevelopment:
- Utilization of 10% of total permissible FAR for Commercial Uses to make the redevelopment process financially feasible.
v. Use premises such as National Security Establishments and Disaster Management Units shall be permitted within the categories mentioned in above Table.]
¹ [Table 13.11: Development Controls for Security (Police) Facilities]
Sl.No.
Category
Maximum
Other Controls
Ground Coverage
FAR
Height
1
Police Post
35%
150
15 m.
1. Upto 30% of max. FAR can be utilized for residential use of essential staff 2[(except Police Station which will as per ** of Notes below the Table).]2. Parking standard @ 2.00 ECS / 100 sq m of floor area.3. Additional space available in police station due to increased development controls shall be used for locating Civil Defence and Home Guards etc.4. Upto 15% of max. FAR can be utilized for residential use/hostel for essential staff and student accommodation, in Police Training Institute / college.5. Other controls related to basements etc. are given in the Development Code chapter.
2
Police Station
30%
200**
26 m.
3
District Office and Battalion
30%
120
26 m.
4
Police Lines
Land Distribution:i) Administration 20%ii) Residential 30%iii) Sports & Facilities 10%iv) Open Spaces
5
District Jail
30%
120
25 m.
6
Police Training Institute / College*
30%
120
26 m.
7
Police Firing Range
12.5%
25
9 m.
13.6Safety
13.6.1 Fire
Fire services have to play pivotal role and be fully prepared in protecting people from fire hazards, building collapses, road accidents and other unforeseen emergencies etc. At present, there are 36 fire stations in Delhi.
¹ [Table 13.12: Planning Norms and Standards for Safety / Fire Facilities]
Sl.No
Category
Population / Unit (approx.)
Plot Area
1
Fire Post
3 to 4 km radius
2000 sqm
2
Fire Station
5 to 7 km radius
1.0 Ha.
3
DisasterManagement Centre
One in each Administrative Zone
1.0 Ha. along with suitable open area (2Ha) for soft parking, temporary shelter, parade ground etc.
4
Fire TrainingInstitute / College
City level (one site in a rha extension)
3.0 Ha.
² [Table 13.13: Developn er / Controls for Safety / Fire Facilities]
Sl.No.
Category
Maximum
Other Controls
Ground Coverage
FAR
Height
1
Fire Post
30%
120
26 m.
1. Upto 25% of max. FAR can be utilized for residential use of essential staff in fire station.2. Parking standard @ 1.33 ECS / 100 sq m of floor area.3. Upto 15% of max. FAR can be utilized for residential use/hostel for essential staff and student accommodation, in Fire Training Institute / college.4. Other controls related to basements etc. are given in the Development Code chapter.
2
Fire Station
30%
120
26 m.
3
Disaster Management Centre
30% (on building area only)
120
26 m.
4
Fire Training Institute / College
30%
120
26 m.
13.6.2 Guidelines for Locating Fire Stations & Other Fire Fighting Facilities in Urban Extension
i. Fire stations should be located so that the fire tenders are able to reach any disaster site within 3-5 minutes.
ii. Fire Stations shall be located on corner plots as far as possible and on main roads with minimum two entries.
¹ Deleted vide S.O. 2790(E) dated 24-08-2016
² Deleted vide S.O. 2790(E) dated 24-08-2016
iii. In the new layouts, concept of underground pipelines for fire hydrants on the periphery, exclusively for fire fighting services should be considered.
iv. Fire stations are permitted in all land use zones except in Recreational use zone.
v. Necessary provisions for laying underground / over ground fire fighting measures, water lines, hydrants etc. may be kept wherever provision of fire station is not possible.
vi. The concerned agencies shall take approval from Fire Department for fire fighting measures while laying the services for an area.
13.6.3 Disaster Management Centre
According to the Indian Seismic Zone map, Delhi is placed in Seismic Zone IV, which means high damage risk zone. In the past, several earthquakes of Richter magnitude 5.5 to 6.7 have occurred in the National Capital Territory of Delhi. Two major lineaments, namely Delhi-Haridwar ridge and Delhi-Muradabad faults pass through the territory, both having potential of generating earthquakes of the magnitude upto 6.5 to 6.7 in future. Such natural and man-made disasters neither can be prevented nor predicted. However, with the technological advancement to some extent mechanism can be developed to mitigate the after effects of the disaster. Areas of vulnerability can be identified and necessary measures can be proposed by the concerned agencies. The concerned local bodies should keep updating the building bye-laws to safeguard against disasters and ensure effective and impartial enforcement. Following policies and strategies for disaster management are proposed:
1. Pre-Disaster Preparedness
i. a) Micro-zonation surveys should be referred for land use planning and be considered while preparing the Zonal Plans and Layout Plans.
Seismic micro-zonation for selected areas having high growth rates should be taken up on priority.
On the basis of vulnerability studies and hazard identification, which includes soil conditions, probable intensity of earthquake, physiographic conditions of the area, fault traces, etc., local level land use zoning and planning should be undertaken.
b) Building bye-laws should incorporate the aspects of Multi Hazard Safety, and Retrofitting.
Priority should be given to public buildings (such as hospitals 1[/tertiary health care centres], educational, institutional, power stations, infrastructure, heritage monuments, lifeline structures and those which are likely to attract large congregation) for their ability to withstand earthquake of the defined intensity.
Suitable action should be taken for retrofitting and strengthening of structures identified as vulnerable as per earthquake manuals and National Building Code. A techno-legal regime has to be adopted for provisions on Multi Hazard Safety aspects.
ii. Delhi Fire Services being the nodal agency for disaster management should identify vulnerable areas such as areas with high density and poor accessibility in the city and propose suitable measures. Proposed Disaster Management Centres should be established in every zone to deal with the disasters, including bio-chemical and nuclear disasters.
iii. Sensitize people, particularly school children, about after effects of disaster.
iv. Make people aware through media campaigns and advertisements about emergency procedures and location of emergency shelters etc.
2. Post Disaster Management
i. It has been observed that any disaster is generally followed by break down of communication lines and disruption of essential services. Therefore, the key communication centres should be protected from natural disasters i.e. flood, fire and earthquake etc. and services restoration should be taken up on top most priority. Necessary setup should be created in each of the concerned department for such eventualities.
13.7Distributive Facilities
Milk, Fruit, vegetable and LPG are the basic requirements of the day-to-day life, and should have proper distribution set-up.
PDS facilities / fair price shops may be provided in close proximity to EWS / LIG housing / resettlement colonies at the same standard as the milk / vegetable booths.
Table 13.14Planning Norms and Standards for Distributive Services
Sl. No.
Category
Population / unit
1
Milk Booth /Milk and Fruit & Vegetable Booth
One per 5000 population. As per standard design of the concerned department.
2
LPG godown including booking office
3 LPG godowns per one lakh population.
3
SKO / LDO outlets
As per standard design of the concerned department.
Table 13.15Development Controls for Distributive Services
Sl. No.
Category
Maximum
Other Controls
Ground Coverage
FAR
Height
1
Milk Booth /Milk and Fruit & Vegetable Booth
Permitted in all zones as per approved layout plan.
2
LPG godown including booking office
i. Plot size - upto 600 sqm including booking office and security hut. ii. Permitted in all use zones except in residential and recreational use zones subject to statutory clearances.
3
SKO / LDO outlets
i. Permitted in all use zones except in residential and recreational use zones subject to statutory clearances.
13.8Socio - Cultural Facilities
Table 13.16Planning Norms and Standards for Socio-Cultural Facilities
Sl. No.
Category
Population / unit (approx.)
Plot Area
123456<sup>1</sup>[7
a) Banquet Hall b) Multipurpose Community Hall which may include provision for marriages, small public gathering, function, eating joint, and library etc. a) Community Recreational Club b) Recreational Club Socio-cultural activities such as auditorium, music, dance & drama centre/ meditation & spiritual centre etc. Exhibition -cum-Fair Ground Science Centre International Convention Centre Socio-Cultural Centre
100001.0 lakh 1.0 lakh 5.0 lakh 1.0 lakh 2 sites in new urban extension 10.0 lakh City Level Sub-City Level
800-2000 sqm 2000 sqm 2000 sqm 5000 sqm 1000 sqm Upto 40 ha. Each As per requirement As per requirement As per Requirement]
Table 13.17Development Controls for Socio-Cultural Facilities
Sl. No.
Category
Maximum
Other Controls
Ground Coverage
FAR
Height
12
a) Multipurpose Community Hall b) Banquet Hall a) Community Recreational Club
30%30%2[30%
120120120]
26 m 26 m 26 m
1. Parking standard @ 3.0 ECS / 100 sq m of floor area. 2. Other controls related to basements etc. are given in the Development Code chapter. Parking standard @ 2 ECS / 100 sq m of floor area
1 Added vide S.O. 2790(E) dated 24-08-2016
2-2 Modified vide S.O. 2895(E) dated 23-09-2013
Sl. No.34562[7
Category
Maximum
Other Controls 1. Parking standard @ 2 ECS / 100 sq m of floor area. 2. A proper scheme for visitors parking and parking adequacy statement shall be prepared taking into consideration large number of visitors. Subject to statutory clearances Parking standard @ 2 ECS i. Parking standard @ 2 ECS/ 100sqm of floor area. 1[ii. Exhibition space, Convention and meeting space shall be minimum 40% of floor area. Retail trade, office space/ commercial office, Hotels and related activities shall be upto maximum 60% of floor area.] 1. Parking standard @ 2 ECS / 100 sq m of floor area. 2. Socio Cultural activities shall be minimum 40% of floor area. Retail trade, office space/ commercial office, Hotels and related activities shall be upto maximum 60% of floor area.]
Ground Coverage
FAR
Height
b) Recreational Club Socio-cultural activities such as auditorium, music, dance & drama centre/ meditation & spiritual centre etc. Exhibition -cum - Fair Ground Science Centre International Convention centre Socio-Cultural Centre
35%20%30%1[40%]40%
12020120120120
26 m--26 m NR, subject to approval of AAI, Fire Department and other statutory bodies NR, subject to approval of AAI, Fire Department and other statutory bodies.
1 Added vide S.O. 1901(E) dated 26-05-2016
2 Added vide S.O. 2790(E) dated 24-08-2016
i) The Recreational Clubs located in LBZ Area, Civil Lines Bungalow Area, Recreational Use Zones and existing on Heritage Structures will be dealt on case to case basis and Technical Committee of DDA will approve the Development Controls norms based on the existing status.]
ii) In the open area apart from outdoor games / sport facilities, swimming pool would be permissible upto a area of 300 sqm. free from ground coverage.
iii) In case of Banquet Hall
a) Basements within the ground envelope shall be allowed for parking. Stilt floor for parking is permissible.
b) 30% of basement area for services / storage shall not be counted in FAR.
1[v] In case of International Convention Centre, maximum 10% ground coverage shall be allowed for providing atrium. In case, the permissible additional ground coverage for atrium is utilized, 25% of the utilized ground coverage shall be counted towards FAR.]
13.9Other Community Facilities
The Planning Norms, Standards and Development Controls for other facilities such as old age homes, religious facilities, etc. are as given in Table 13.18.
Table 13.18Planning Norms and Standards for Other Community Facilities
Sl. No.
Category
Population / Unit (approx.)
2[+] Plot Area
1
a) Old Age Homeb) Care Centre for 3[differently abled persons]- Mentally challengedc) Working women- men hosteld) Adult Education Centree) Orphanage/ Children's centre (One each)f) Night shelter 5[*]g) 8[Service Apartment
5 lakh Each category for 10 lakh6[1 lakh]100000
4[Maximum] 1000 sqm subject to availability of land7[Minimum 100 sqm, subject to availability of land.] Minimum 2000 sqm.]
¹ Added vide S.O. 2890(E) dated 23-09-2013
² Deleted vide S.O. 2894(E) dated 23-09-2013
³ Modified vide S.O. 2895(E) dated 23-09-2013
³⁻⁵ Modified vide S.O. 2894(E) dated 23-09-2013
⁷ Modified vide S.O. 1596(E) dated 29-04-2016
⁸ Added vide S.O. 2895(E) dated 23-09-2013
Sl.No.
Category
Population / Unit(approx.)
²[-] Plot Area
2
Religious Facilitiesa) At neighbourhood levelb) At sub city level in urban extension
500010 lakh
¹[Max.] 400 sqm²[Max.] 4.0 Ha.
3
Anganwaria) Housing area / cluster
5000
³[Max.] 200-300 sqm
Upto 10% variation in plot size is permitted.
4[* The actual location and need of night shelter is to be decided by the Local Authorities / GNCTD based on practical demand / assessment. For geographical distribution of Night Shelters a minimum of at least one Night Shelter per administrative unit such as the Revenue Sub-Division or jurisdiction of Police Station may also be taken as criteria for planning purposes.]
7 [Notes:
i) The minimum size of the apartment will be 40 sqm built-up.
ii) The plots should be located on road facing minimum width of 12m.
iii) Basement, if constructed, and used only for parking, utilities and services shall not be counted towards FAR.]
Table 13.19Development Controls for Other Community Facilities
Sl.No.
Category
Maximum
Other Controls
Ground Coverage
FAR
Height
1
5[Old Age Home / Care Centre for differently abled persons] / Mentally challenged/ Working women /men hostel / Adult Education Centre / Orphanage / Children's Centre 6
30 %
120
26 m
1. Parking standard @ 1.8 ECS / 100 sqm of floor area.2. Other controls related to basements etc. are given in the Development Code chapter.
2
Religious a) At neighbourhood level
35 %
70
15 m including shikhara
¹⁻¹⁰ Modified vide S.O. 2894(E) dated 23-09-2013
¹¹ Added vide S.O. 2894(E) dated 23-09-2013
⁵ Modified vide S.O.2895(E) dated 23-09-2013
⁶ Modified vide S.O. 1596(E) dated 29-04-2016
Sl. No.32[43 [5
Category
Maximum
Other Controls 1. Parking Standards 2.0 ECS / 100 Sqm. of Floor area. 2. A proper scheme for visitors parking and parking adequacy statement shall be prepared taking into consideration large number of visitors. ] Parking @ 2 ECS per 100 sqm. of floor area. Other controls related to basements etc. are given in the Development Code chapter.] Parking: (i) NIL, for plots measuring less than 500 sqm. (ii) 2 cars/ service vehicles, for plots measuring 500 sqm and above.]
Ground Coverage
FAR
Height
1[ b) At sub city level in urban extension* Anganwari a) At Housing area / cluster level Service Apartment Night Shelter
30 %30 %30 %60 %
10060225200
26 m 15 m NR* (subject to approval of AAI, Fire Departme nt and Other Statutory Bodies.) 26 m
* These facilities should be developed in a composite manner to accommodate a number of religious institutes / premises with common facilities.
Note: Sites for Dhobi ghats / laundry shall be provided in Residential use zone / PSP facility areas as per the norms of local body.
1 Modified vide S.O. 3216(E) dated 22-09-2020
2 Added vide S.O.2895(E) dated 23-09-2013
3 Modified vide S.O. 1596(E) dated 29-04-2016
13.10Cremation Ground, Burial Ground & Cemetery
At present there are 59 cremation grounds and 4 graveyards (qabristans) of the ¹[Municipal Corporation of Delhi] and Delhi Waqf Board has 53 burial grounds.
i) In the existing cremation grounds, provision of crematorium is to be made.
ii) In proposed urban extension new burial grounds / crematorium / cremation grounds / cemetery etc. are to be planned with proper parking and landscape provisions. The plot area to be ² [up to 0.5 Ha.] per 5.0 lakh population for a cremation ground and upto 1.0 Ha. per 10 lakh population for a cemetery and burial ground subject to availability of land.
iii) 3[In proposed urban extension new burial grounds/ crematoriums are to be planned for pet and stray animals. The plot area to be up to 0.2Ha. per 10 lakh population.
iv) Burial Grounds for pet animals should be located separately from burial grounds, crematoriums and cemetery.]
13.11Public & Semi-public Facilities / Premises
The following norms shall be applicable in case of PSP facilities / premises, for which specific development controls have not been specified.
Max. Ground Coverage 30%
Max. Floor Area Ratio 120
Max. Height 26 m.
Other controls:
Parking @ 2 ECS/ 100 sqm. of floor area. Other controls as given in Development Code chapter.
i) ⁴ [In case of plots allotted to political parties by the government land housing agencies, up to 15% of maximum FAR may be utilized for residential hostel accommodation.]
ii) 5[Amalgamation of the smaller PSP plots or sub division of the larger PSP plots for a single or its multiple use, is allowed with the permissible PSP facilities as per the provisions of MPD-2021.]
¹ Modified vide S.O.3173(E) dated 24-08-2016
² Added vide S.O. 2789(E) dated 24-08-2016
³ Added vide S.O. 2789(E) dated 24-08-2016
⁴ Added vide S.O. 2894(E) dated 23-09-2013
⁵ Added vide S.O. 2895(E) dated 23-09-2013
Definitions and Permissible Use Premises in Sub Use Zones
Table 13.20Health Facilities
Sl. No.
Use Premises
Definitions
Activities Permitted
1.
Hospital
A premise providing medical facilities of general or specialised nature for treatment of indoor and outdoor patients. It may be managed by public, private or charitable institution.
Hospital, Staff accommodation, patient attendant accommodation, Institutional Hostel, Medical College, <sup>1</sup>[(only on plot size 2.5 ha. to 4.5 ha., approximately),] Parking, Retail Shop. (canteen, confectionery, grocery & general merchandise, books and stationery, chemist, barber, launderer, vegetable), Bank extension counter.
2.
Primary Health Centre/Family Welfare Centre/ Pediatric Centre/ Geriatric Centre/ Diagnostic Centre
A premise having facilities for treating indoor and outdoor patients having upto 10-15 beds. It may be managed by a public or charitable institution on non-commercial basis. It includes family welfare centre & maternity home.
Health Facility Watch & Ward Residence (Upto 20 sqm), Chemist Shop (Upto 20 sqm), Soft Drink & Snack Stall.
3.
Dispensary
A premise having facilities for medical advice and provision of medicine, managed by public or charitable institutions.
Dispensary, Watch & Ward Residence (Upto 20 sqm), Chemist Shop (Upto 20 sqm), Soft Drink & Snack Stall.
4.
Nursing Home/ Maternity Home / Polyclinic
A premise having medical facilities for indoor and outdoor patients having upto 50 beds. It may be managed by a doctor or a group of doctors. In case of polyclinic, it shall be managed by a group of doctors.
A premise having medical facilities for indoor and outdoor treatment of pets animals and birds. It may be managed by a public or charitable institution or on community basis.
A premise having medical facilities for treatment of outdoor patients and other like blood bank etc. by voluntary institutions. This service may also take the form of temporary camp with charitable motive.
Voluntary Health Service, Watch & Ward Residence (upto 20 sqm), Administrative Office, Dispensary, Canteen.
10.
Veterinary Institute
A premise having educational and playing facilities for students of under-graduate & post-graduate courses along with research facilities under a university.
College, Residential Flat (For maintenance staff), Institutional Hostel, Retail Shops of area 20 sqm each (confectionery, grocery and general merchandise, books & stationery, chemist, barber, launderer, vegetable), Canteen, Bank Extension Counter, Auditorium, Indoor Games Hall, Swimming Pool, Play Ground, Post Office Counter Facility, Facilities for Indoor & Outdoor Treatment for Pets, Animals & Birds.
<sup>1</sup>[11
Tertiary health care centre
A premise providing advanced health care facilities of specialised nature such as super specialty/ multi-specialty health care, types of rehabilitation centre, etc. for treatment of patients. It may be managed by public, private or charitable institution.
Hospital, Staff accommodation, patient attendant accommodation, Institutional Hostel, Health care management centre, Parking, Retail Shop (canteen, confectionery, grocery & general merchandise, books and stationery, chemist, barber, launderer, vegetable), Bank extension counter and
1 Added vide S.O. 2893(E) dated 23-09-2013
Sl. No.
Use Premises
Definitions
Activities Permitted
other specific facility(ies) required for diagnosing/treatment/ rehabilitation of such patients.]
Table 13.21Educational Facilities
Sl. No.
Use Premises
Definition
Activities Permitted
1.
Pre-Primary/Nursery/Montessary/ Creche & Day Care Centre
A premise having nursery facilities for infants during day time. The centre may be managed by an individual or an institution on commercial or non-commercial basis.
Creche & Day care Centre, Watch & Ward Residence (upto 20 sqm).
2.
Primary School
A premise having educational and playing facilities for students upto V standard.
Nursery School, Primary School, Watch & Ward Residence (Upto 20 sqm). Books & Stationery Shop (Upto 20 sqm.), Soft Drink & Snack Stall.
3.
Middle School
A premise having educational and playing facilities for students upto VIII standard.
Nursery School, Middle School, Watch & Ward Residence (Upto 20 sqm), Books & Stationery Shop (Upto 20 sqm.), Soft Drink and Snack Stall.
4<sup>1</sup>[ (a) ]
Senior Secondary School
A premise having educational and playing facilities for students upto XII standard.
Nursery School, Sr. Secondary School, Watch & Ward Residence (Upto 20 sqm), Books and Stationery Shop, Uniform Shop (Upto 20 sqm each) Soft Drink & Snack Stall, Canteen, Bank Extension Counter, Auditorium, Indoor Games Hall, Swimming Pool, Post Office Counter Facility.
<sup>2</sup>[ 4 (b)
Secondary School
A premise having educational and playing facilities for students from VI to XII standard.
Secondary School, Watch & Ward Residence (Upto 20 sqm), Books and Stationery Shop, Uniform Shop (Upto 20 sqm each), Soft Drink & Snack Stall, Canteen, Bank Extension Counter, Auditorium, Indoor Games Hall, Swimming Pool, Post Office Counter Facility.]
1-2 Added vide S.O. 2895(E) dated 23-09-2013
Sl. No.
Use Premises
Definition
Activities Permitted
5.
School for Mentally challenged & 1[differently abled persons]
A premise having educational (formal and vocational) and playing facilities for mentally challenged& 2[ differently abled persons]
School, Ward & Watch Residence (Upto 20 sqm), workshop, sale counter, hostel facility (15% of permissible built up area), Books & Stationery Shop (Upto 20 sqm), Canteen, Bank Extension Counter, Post Office Counter facility, Indoor Games Hall, Upto 20% of max. FAR can be utilized for residential use of essential staff and student accommodation, office, professional activity, rehabilitation centre.
6.
College (including Professional College)
A premise having educational and playing facilities for students of under-graduate & post-graduate courses under a university. It includes all professional disciplines.
College, Residential Flat (For maintenance staff), Hostel, Retail Shops of area 20 sqm each (confectionery, grocery and general merchandise, books & stationery, chemist, barber, launderer, vegetable), Canteen, Bank Extension Counter, Auditorium, Indoor Games Hall, Swimming Pool, Playground, Post Office Counter facility.
7.
Library
A premise having a large collection of books for reading and reference for general public or specific class.
Library, Watch & Ward Residence (upto 20 sqm.), canteen, exhibition and art gallery, auditorium.
8.
Technical Training centre / Institute, Nursing and Paramedic Institute
A premise with facilities for training in discipline of technical nature. It includes technical school and industrial training institute etc.
Technical Training Centre, Residential flat (for maintenance staff), Books and stationery and chemist shops (Upto 20 sqm each) Canteen, Bank Extension counter, Auditorium, Post Office Counter facility.
9.
Vocational Training Institute
A premise with training facilities for short term courses for discipline e.g. Commercial, Secretarial, Nursing training etc., preparatory to the employment in certain profession & trade. It shall be
Vocational Training Institute, Watch & Ward Residence (upto 20 sqm.), Hostel (only in case of Government Centres), Books & Stationery Shop (Upto 20 sqm.), Canteen, Library, Chemist Shop (Upto 20 sqm),
14 Modified vide S.O. 2895(E) dated 23-09-2013
Sl. No.
Use Premises
Definition
Activities Permitted
run by public or charitable institution on non-commercial basis. It includes training-cum-work centre.
Bank Extension Counter, Auditorium, Post Office Extension Counter Facility.
10.
Commercial and secretarial training centre
A premise having training facilities for stenography, correspondence, record keeping etc.
Commercial and secretarial training centre, Watch & Ward Residence (upto 20 sqm.), Canteen.
11.
Hotel Management Institute
A premise with training facilities for hotel management discipline. It shall be run by public/ private body. It includes training-cum-work-centre.
Hotel Management Institute, Watch & Ward Residence (Upto 20 sqm), Books and stationery and chemist shops (Upto 20 sqm each) Canteen, Bank Extension counter, Auditorium, Post Office Counter facility.
12.
Social Welfare Centre
A premise having facilities for welfare and promotion of community development. It shall be run by a public and charitable institution.
Social Welfare Centre, Watch & Ward Residence (upto 20 sqm.) canteen, Exhibition cum sale counter.
13.
Research and Development Centre
A premise providing facilities for research and development for any specific field.
Research and Development Centre, Watch & Ward Residence (upto 20 sqm.) residential flat,(For maintenance staff) Hostel, Canteen, Bank Extension counter, Library, Post Office counter facility.
14.
University Campus and International Education Centre
A premise having an educational institution designed for instruction, examination, or both, of students in many branches of advanced learning, conferring degrees in various faculties, and often embodying colleges and similar institutions.
Educational Institution, Colleges, Residential Flat (for maintenance staff), Institutional Hostel, Retail Shops of area 20 sqm each (confectionery, grocery and general merchandise, books & stationery, chemist, barber, launderer, vegetable), Residential, Library, Bank Extn. Counter, Auditorium, Post Office Extn. Counter Facility, Canteen, Indoor Games Hall.
Table 13.22Sports Facilities
Sl. No.
Use Premises
Definition
Activities Permitted
1.
Divisional Sports Centre/ Golf Course
A premise for Outdoor and Indoor games with pavilion buildings, stadium structure for
a. Sports related Commercial component - 5% of total floor area.
spectators and related facilities.
b. Multiuse Stadium (Seating capacity 15,000). c. Multipurpose Hall (Seating capacity 4,000) for Exhibitions, Trade Shows, Banquets, Multiple sports & related events, d. Aquatic Centre (covered or otherwise with full size competition pool, a training / lap pool, diving pool which can also be used for Water Polo and Synchronized swimming as well as other aquatic recreational facilities like waterslides, wave pool, hydrotherapy pool, Akhara etc. e. Facilities for Outdoor Sports like Cricket, Football, Hockey Grounds etc including extreme sports & Golf Course/ Range. f. Sports academy for multiple sports events. g. Sports Medicine Centre. h. Residential accommodation / Hostel, Watch & Ward Residence. i. Playground.
2.
District Sports Centre
A premise for Outdoor and Indoor games with pavilion buildings, stadium structure for spectators and related facilities.
a. Indoor Stadium with ancillary halls for basket ball, badminton, table-tennis, volley ball, swimming pool. b. Facilities like open Cricket, Football and Hockey grounds, Skating Rinks, Jogging track, Cricket practice nets, children's' corner, etc. c. Provision for extreme sports like skate boarding, etc., can also be made. d. At least one of these can be designed for a sports academy/ sports training centre for multiple sports
events with residential accommodation/ hostel. Retail shops, bank, post office & sports related commercial component - 5% of total FAR. e. Playgrounds.
3.
Community Sports Centre
A premise used for Outdoor Games. It may have landscaping, parking facility, public toilets etc.
These can have facilities like open Cricket, Football and Hockey grounds, Volleyball courts, Skating Rinks, Jogging track, Cricket practice nets, children's' corner, etc. Besides, amenities for small change rooms, offices, lavatories and store rooms should be provided. In these some provision for extreme sports like skate boarding, etc., can also be provided, Playgrounds, sports centre related component maximum 5% of FAR for sports, retail shops, cafeteria/ snack bar.
Table 13.23Communication Facilities
S. No.
Use Premises
Definition
Activities Permitted
Post Office
1.
Post office Counter (without delivery)
A premise with facilities of post office counter only (without post delivery)
Post office counter, watch and ward residence (upto 20 sq mt).
2.
Post and Telegraph office (Booking & Delivery)
A premise with facility for postal and telegraphic communication.
Telegraph office, watch and ward residence (upto 20 sq mt).
3.
General and Head Post Office with Administrative office with/without delivery office
A premise with facility for postal and telecommunication to and from a number of post offices attached to it.
Head post office, general post office, watch and ward residence (upto 20 sq.mt), canteen.
Telephone
4.
Telephone Exchange/ RSU
A premise having central facilities for operation of telephone system for a
Telephone Exchange/RSU, Logistics, Watch & Ward Residence (upto 20 sqm.)
designated area.
canteen.
5.
Radio & Television Station
A premise with facilities for recording, broadcast and transmission of news and other programmes through the respective medium. It may include some hostel accommodation for artists, transmission facilities like towers.
Radio and television station, watch and ward residence (upto 20 sqm) hostel, library and canteen.
6.
Transmission Tower and wireless station
A premise used for installation of a tower for communication purposes.
Transmission tower, watch and ward residence (upto 20 sqm).
7.
Satellite and Tele-Communication Centre
A premise with facilities for research & development of satellite & telecommunication technology.
Satellite and telecommunication centre, residential flat (for maintenance staff), watch and ward residence (upto 20 sqm) research laboratory, canteen.
8.
Observatory & Weather Office
A premise with facilities for research and development of data relating to weather and forecasting thereof.
Observatory and weather office, residential flat (for maintenance staff), watch and ward residence (upto 20sqm).
<sup>1</sup>[9.
Media & News Agency including Media Training Centre
Table 13.24Security Facilities
Sl. No.
Use Premises
Definitions
Activities Permitted
1.
Police post
A premise having facility for a local police post of a temporary nature or on smaller scale as compared to a police station.
Police Post, essential staff housing.
1 Added vide S.O. 465(E) dated 15-02-2016
Sl. No.
Use Premises
Definitions
Activities Permitted
2.
Police station
A premise having facilities for offices of local police post.
A premise having facilities for the offices and paramilitary forces.
District Police Office and Civil Defence & Home Guard residential flat (For maintenance staff) Hostel Play Ground, canteen, bank extension counter.
4.
Police Line
An area having facilities for work and residential accommodation of paramilitary forces.
Police line and related facilities.
5.
Jail
A premise with facilities for detention, confinement and reform of criminals under the law
Jail and related facilities.
6.
Police Training Institute/College
A premise having facilities for training of paramilitary forces.
Training institute/college, residential flat (for maintenance staff), hostel, retail shops of area 20 sqm each, confectionery, grocery, merchandise, books and stationary, chemist, barber, laundry, vegetable, canteen, bank extension counter, auditorium, indoor, outdoor games, swimming pool, playground, post office counter facility.
7.
Police Firing Range
A premise having facilities for firing practice of the paramilitary forces.
Police firing range (Temporary Structure only).
8.
Traffic and Police Control Room
A premise of temporary structures having facilities for the managing of traffic, & law and order related issues.
Temporary traffic and police control room.
9.
Civil defense and home guards etc.
A premise having facilities for offices and other functions of civil organization for internal defence.
Civil Defence & Home guard residential flat (for maintenance staff) hostel play ground, canteen, bank counter.
10.
Forensic science laboratory
A premise having facility for application of medical knowledge.
Forensic science laboratory and related facilities.
1 Added vide S.O. 2894(E) dated 23-09-2013
Sl. No.
Use Premises
Definitions
Activities Permitted
<sup>1</sup> [11.
Police Outpost
A premise having facilities for providing security and maintaining Law & Order in an area where high foot falls are reported such as Malls, Shopping Complexes, Institutional areas, Rail/Bus/Air terminals etc.
Police Outpost, officers room with facilities for recording NCR (Non Cognizable Report) and storing emergency equipments, dormitory with toilet & bath facilities, kitchen etc.
12.
National Security Establishments
A premise having establishments undertaking issues of National Security or as defined/ notified by GOI from time to time.
First Aid Facility, Emergency Backup, Temporary Communication Centre, Disaster Preparedness, Watch & Ward residence (upto 20 sq.m), if required, and related facilities. ]
Table 13.25Safety – Fire
S. No.
Use Premises
Definitions
Activities Permitted
1.
Fire post
Premises with lesser degree of facilities for fire fighting. The post may be attached to specific premises with fire prone activities.
Fire post with residential flat for staff.
2.
Fire station
A premise having facility for fire fighting for a catchment area assigned to it. It may include residence of essential staff.
Fire station, residential flat, service workshop.
3.
Fire station with essential residential accommodation
A premise having facility for fire fighting for a catchment area assigned to it. It includes residence of essential staff.
Fire station residential flat (for maintenance staff), hostel (for employees), service workshop.
4.
Fire Training Institute
A premise having facilities of training for emergency times in case of fire, building collapse etc.
Fire training centre, hostels, staff residences, open practice grounds, fire station, watch and ward residence (upto 20 sq m) etc.
5.
Disaster Management Centre
A premise having facility of disaster emergency backup, hospital facility, training centre for disaster preparedness, wireless communication etc.
Disaster management training centre, hospital <sup>2</sup>[/ tertiary health care centre], open grounds for practice and relief camps, communication centre, hostels, staff residences, fire station, watch and ward
1 Added vide S.O. 2790(E) dated 24-08-2016
2 Added vide S.O. 2893(E) dated 23-09-2013
S. No.
Use Premises
Definitions
Activities Permitted
residence (upto 20 sq m) etc.
<sup>1</sup>[6.
Disaster Management Units
A premise having establishments undertaking issues of Disaster Management or as defined/ notified by GOI from time to time.
First Aid Facility, Emergency Backup, Temporary Communication Centre, Disaster Preparedness, Watch & Ward residence (upto 20 sq.m), if required and related facilities.]
Table 13.26Distributive Services
S. No.
Use Premises
Definitions
Activities Permitted
1.
Milk Booth/Milk and Fruit & Vegetable Booth/Delhi Milk Supply Booth
A premise with basic facility for the supply of daily groceries to the local population.
Booth/ built structure for display and sale of dairy products/ fruits and vegetables etc.
2.
Dairy Farm
A premise with facility for rearing and processing of dairy products. It may have temporary structures for sheds of animals.
Dairy farm, watch & ward residence (upto 20 sqm.) All structures shall be temporary in nature.
3.
Poultry Farm
A premise with facility for rearing and processing of poultry products. It may have temporary structures for sheds of birds.
Poultry farm, watch & ward residence (upto 20 sqm.) All structures shall be temporary in nature.
4.
Piggery
A premise with facility for rearing and processing of piggery products. It may have temporary structures for sheds of pigs.
Piggery shed, watch & ward residence (upto 20 sqm.). All structures shall be temporary in nature.
5.
LPG godown including booking office
A premise for the booking, storing and supply of LPG to local population.
A premise having the facility of wholesale storage of LPG, godown, etc.
Gas godown, watch & ward residence (upto 20 sqm.) Care taker office.
1 Added vide S.O. 2790(E) dated 24-08-2016
Table 13.27Socio-Cultural and Community Facilities
Sl. No.
Use Premises
Definitions
Activities Permitted
1.
Multipurpose Community Hall, Barat ghar
A premise having an enclosed space for various social and cultural activities.
Community Hall, Watch & Ward Residence (upto 20 sqm.) Soft Drink and Snack Stall and library etc.
2.
Music Dance and Drama Training Centre
A premise having facilities for imparting training and coaching for music, dance and dramatics.
Music, dance and drama training centre, watch and ward residence (up to 20 sq m.), canteen, auditorium.
3.
Yoga Meditation, Spiritual and Religious Discourse Centre
A premise having facilities for self attainment, achieving higher quality of mind and body, spiritual and religious discourse etc.
Yoga centre, meditation, spiritual and religious discourse centre, watch and ward residence (up to 20 sq mt), hostel, soft drink and snack stall.
4.
Recreational Club
A premise having the facility for recreation with indoor sports, swimming pool, outdoor sports, socializing and gathering space for small functions with restaurant.
Recreational club, watch & ward residence (upto 20 sqm.) Residential flat (for maintenance staff), swimming pool, indoor and outdoor games facilities club.
5.
Banquet Hall
A premise to hold small public gatherings, community functions, marriages, etc.
Hall for public gatherings, marriages, cooking facilities and other logistics.
6.
Open air theater
A premise having facilities for audience seating and a stage for performance and open to sky.
Open Air theatre, Watch & Ward Residence (upto 20 sqm.) canteen.
7.
Auditorium
A premise having an enclosed space to seat audience and stage for various performances like concerts, play, recitals, functions etc.
Auditorium, Watch & Ward Residence (upto 20 sqm.) canteen.
8.
Museum
A premise with facilities for storage and exhibition of objects illustrating antiques, natural history, art etc.
Museum, Watch & Ward Residence (upto 20 sqm.) canteen.
9.
Exhibition-cum-Fair Ground
A premise having facilities for the exhibition and display and other cultural activities for a group of participants.
Fair Ground, Residential Flat (for maintenance staff) Exhibition Centre (Temporary in nature) Restaurant, Soft Drink & snack Stall, Police Post, Fire Post, bank Extension counter facility, Post Office counter facility.
1 Added vide S.O. 1901(E) dated 26-05-2016
Sl. No.
Use Premises
Definitions
Activities Permitted
17.
Dharamshala and its equivalent
A premise providing temporary accommodation for short duration on no profit basis.
Dharmshala, personnel service shops of barber and launderer, soft drinks and snack bar (upto 20 sq m).
18.
Adult Education Centre
A premise having the facility of formal education and training to adults with flexible timings.
Flexible use given to a primary school, community centre or any such community building.
19.
Reformatory
A premise with facilities for behavioural reforms.
Reformatory and Orphanage, Residential Flat (For maintenance staff), Hostel, Personnel Service shop (upto 20 sqm.).
20.
Orphanage
A premise having the facility of boarding of children who are bereaved of parents. It may or may not have educational facilities.
Hostels, residence (for management and maintenance staff), primary school, watch and ward residence (upto 20 sq m).
21.
Reformatory and Orphanage
A premise with facilities for confinement and behavioural reform, boarding of children who are bereaved of parents. It may or may not have educational facilities.
Reformatory and Orphanage, Residential Flat (For maintenance staff), Hostel, Personnel Service shop (upto 20 sqm.).
22.
Old Age Home/Care Centre for 1[differently abled persons] / Mentally challenged / Working women/ Men Hostel
A premise having the facility of caring and training boarding & lodging of the elderly / 2[differently abled persons] / mentally challenged / working women / men.
Care home with residential facility, residence (for management and maintenance staff), primary school, recreational, library, health, gym, canteen, dining facility.
23.
Religious Premises / Building
A premise dedicated to the service of the objects of religious nature. It may have different nomenclature in different religions / faiths.
Temple, Mosque, Church, Gurdwara, Synagogue, Ashram, Bathing Ghat, Gaushala, Dargah, Charitable Dispensary, Library. 2[The following activities allowed for Religious plots at Sub-City level: a. Training Centre for Yoga b. Spiritual activities & Meditation, Museum/Art
¹⁻² Modified vide S.O. 2895(E) dated 23-09-2013
² Added vide S.O. 3216 (E) dated 22-09-2020
Sl. No.
Use Premises
Definitions
Activities Permitted
Gallery/Exhibition Centre c. Auditorium d. Accommodation for preachers/ devotees/ management staff (Max. 15% of total FAR) e. Canteen/ Restaurant, Langar Hall/ Kitchen f. Bank extension Counter /ATM facility, Prayer halls.]
24.
Dhobi Ghat/ Machine Laundry - public utility premises
A premise used for cleaning and drying of clothes and linen.
Overhead tank, Underground Tank, Oxidation Pond, Septic Tank Sewerage Pumping station, Public Toilet & Urinal, Electric Sub-station, Dhallao and Dustbin, Dhobi Ghat, Machine Laundry.
<sup>1</sup>[25
Short Term Accommodation (Hostel / Guest House / Boarding and Lodging House / Working women-men Hostel / Service Apartment)
A premise fully furnished, serviced and self-contained with meal preparation and used for short term or long term individual, family or corporate accommodation
i) Guest Suite ii) Conference Facilities, Office, Retail and Service Shops and Common Dining Facilities, and other facilities supporting the main activity (restricted up to 20% of permissible FAR).]
<sup>2</sup>[26.
Socio-Cultural Centre
A premise with facilities that promote culture & other activities that include traditions or living expressions such as oral traditions, performing arts, social practices, rituals, festive events, knowledge and practices concerning nature and the universe or the knowledge and skills.
Outdoor spaces / amphitheatre for cultural activities, museums (art, cultural artifacts, natural history, science, community etc.), planetarium, auditorium, exhibition areas, convention centre, literary / film festival, Film centre, Multipurpose training and meeting rooms, Areas for public education, Documentation centre, library, Temporary as well as permanent exhibition areas, commercial office / retail space, Guest rooms, Hotels with permissibility of activities as per Table 13.17 and Table 5.5. ]
1 Added vide S.O. 2895(E) dated 23-09-2013
2 Added vide S.O. 2790(E) dated 24-08-2016
Table 13.28Cremation / Burial Ground and Cemetery
Sl. No.
Use Premises
Definitions
Activities Permitted
1.
Burial ground
A premise with facilities for burying of dead bodies.
Burial Ground, Cremation Ground Cemetery and Crematorium, retail shops of Wood, flowers and related materials, Watch & Ward Residence (upto 20 sqm.).
2.
Cremation ground
A premise with facilities of performing last rites of dead bodies by burning.
3.
Cemetery
A premise with facilities for burying of dead bodies.
Facility for registration of deaths, sheds for performing rituals, drinking water, parking, etc.
4.
Crematorium
A premise with facilities for last rites of the deceased.
--- X---X---X---X---X---
14.0Physical Infrastructure
A key issue related to the sustainable development of Delhi, and a minimum quality and standard of living pertains to the availability of, and accessibility to basic infrastructure facilities viz. water, power, sewerage, drainage and solid waste management. The rapid and almost uncontrolled growth of population has put these facilities under severe pressure, and there are significant deficiencies. Even a cursory analysis of the present state of affairs, infrastructure problems could become a cause of crisis. Sewerage and solid waste management are GNCTD affairs but water supply, power and drainage are Inter-State issues. Thus critical need of advance action and arrangement is required for the adequate provision of physical infrastructure. For each component a broad augmentation plan is essential to meet the projected requirement. GNCTD should prepare a detailed and integrated plan in coordination with concerned authorities, NGOs and community groups.
The Master Plan envisages an integrated approach that packages mutually supportive infrastructure components i.e. water-sewerage-drainage for recycling, harvesting and optimal use of water; solid waste-sewerage-power for power generation, etc. Innovative techniques for the use of alternative technologies like solar energy, recycling, etc., are also to be encouraged. The Plan accepts the need for institutional capacity building, “User Pays” approach and public private partnership as tools for institutional strengthening. To improve the efficiency and to boost the performance, more community participation and decentralised management is required. Technical feasibility of rehabilitation/ augmentation network of sewerage, water supply and drainage is required on priority for old built up areas and the areas identified for redevelopment.
14.1 Projected Requirements for the Year 2021
The existing availability and projected requirement for physical infrastructure components as indicated by the agencies concerned are given in the Annexure I to IV.
14.2Water
Delhi depends largely on river Yamuna and partially on river Ganga for its share of raw water. For sustainable development of Delhi, it is essential to ensure adequate supply of water in terms of reliability, quality and quantity. Although, Delhi has an average water availability of 225 lpcd, the distribution of the same is not uniform. Some areas get 24 hrs water supply, whereas some get hardly 1-2 hr water in a day. In line with the norms laid down in CPHEEO Manual 1999, in respect of mega cities, after taking into account 15% losses, the minimum water supply @ 172 lpcd will have to be ensured for domestic use for the projected population. The water requirement has to be made from river water allocation and ranney wells in Yamuna flood plains. The future supply crucially depends on the progress of the proposed dams in U.P, Uttranchal and H.P; Satluj Yamuna link canal and Sharda Yamuna link canal. Further it will also depend upon the conveyance system, which should be in place before the release of allocated
water to Delhi. However to some extent localised ground water extraction and its supply after treatment to prescribed level of quality may also be required to meet up the demands. In addition, promotion of recycled wastewater based on techno economic feasibility is also to be done by the concerned agencies for water augmentation.
To improve the water supply in accordance with the projected requirement upto the year 2021 Inter-State river water allocation is required to be worked out. All measures are to be taken to reduce unaccounted flow of water (UFW) and production losses at existing water treatment plants. The drainage basins shall be made self-sustainable in water management by integrating water-seweragedrainage systems. It is imperative to not only initiate new projects and upgrade present infrastructure, but also to promote water conservation through an integrated and a community driven model, comprising of complimentary short term and long term measures as given below:
Towns/cities have so far been planned by their respective authorities for their individual needs. There has been total lack of regional approach for sustainable use of available water and its conveyance from areas of plenty to scarcity. The raw water augmentation should not be territory specific but it should be on regional basis irrespective of State boundaries.
Recycling of treated wastewater with separate lines for potable water and recycled water. For this, dual pipeline system has to be introduced in a phased manner in all the areas.
Ground water recharging through rain water harvesting, conserving water bodies and controlling groundwater extraction:
i. Groundwater extraction is to be controlled through registering boreholes and recharging according to test yields. Ground water management is to be enforced by concerned agency.
ii. Focused planning and action will be required to be taken to prepare and implement rain water as roof water harvesting schemes both with the aim of optimizing water use and ground water recharge. For this suitable mandatory provision should be made for planning and construction of various schemes.
iii. Blue print is required to be prepared for Integrated Water Management of all the water resources in the NCR as well as potential for water reservoirs in Himachal Pradesh and Uttaranchal. Further it is vital to identify all the potential surface water sources, ground water aquifers and inter-basin opportunities for transfer of water to the region. This should include water mapping, desilting of existing lakes/depressions for augmentation of storage of rain/flood water, capturing the monsoon run off, rain water harvesting, reuse and recycling of waste water and measures for conservation of water, inter-basin transfer of water. It should also ensure the conservation of
natural depressions, water bodies, flood plains and aquifers. Major water bodies can be developed as places of tourist interest/picnic spots to make them sources of revenue as well as to ensure their protection. The concepts of ‘zero run-off drainage’, with retention ponds, sediments traps and balancing lakes should be adopted, with a segregated wastewater disposal system. A green network overlapping the blue network would protect the ecology of aquifers, and also provide a pleasant environment. Simple methods of site planning, which incorporate porous/semi permeable paving, drop inlet/down pipe, sediment trap, retention ponds, etc. will contribute in maintaining ground water table.
iv. Yamuna River, major drains and canals, with indiscriminate dumping of wastes, have become polluted and foul. These need strict pollution control measures and eco-sensitive land use controls. Water flow needs to be controlled and stabilized and marked at each kilometer station. The valleys should be zoned as water portals, so that these are flanked with greenery, farmlands and forests.
v. One of the prime objectives of development should be to live in harmony with the environment. Efforts should be made to improve the quality of river-water, to secure its continuous flow and to encourage the return of aquatic life. This needs improvement of drainage, waste water treatment and pollution abatement by sewerage improvement. The surplus water during the monsoons should be retained in balancing ponds along the riverbed rather than allowing it to the downstream areas.
vi. The drains and waterfront can be landscaped in the form of interconnected parkways. There is no need for elaborate gardening of the greenways, but wild, simple and natural stretch by itself would be ecologically important. Such trails could be one of the cheapest forms of drainage and recreation.
vii. Water supply in new areas should incorporate separate lines – one for washing, water coolers and garden taps, the second for supplying potable water. All non-residential buildings having a discharge of over 10,000 litres a day should incorporate a wastewater recycling. The capacity of the sewage treatment plants / recycling plants would be equal to or more than the water inflow requirements so that it may be possible to treat major part of the discharge excepting toilets and kitchen discharge. Keeping in view the uses of recycled water, a policy shall be formulated for determining the optimum water requirements for various uses.
viii. The wasteful practice of ‘drill, pump, and spill’ has to be replaced by efficient methods of water conservation, use, and recycling as standard and mandatory procedures. There is a need to incorporate
the mandatory stipulation of water saving/waterless flushing system in the Building Bye-laws.
ix. At the time of preparation of zonal Development Plans, water bodies, large depressions and other ground water recharging areas will be identified and protected from unintentional filling and encroachments.
x. At the time of preparation of Zonal Development Plans, appropriate areas should be identified and earmarked for utilities pertaining to Power (Power Plants and Substations), Water (Sewage Treatment Plants and Sewage Pumping Stations) and Solid Waste management (Solid Waste Treatment Plants and Sanitary landfill sites). Appropriate land should accordingly be earmarked for solid waste management keeping in view a long-term perspective.
Where the hazard of pollution exists, the minimum charge for operating permits should cover the expenses of adequate policing and controls. Mandatory performance bonds and liability insurance should pay for all damages plus any corrective measures, which might be needed. As a governing rule, no new development, manufacturing, process or operation of any polluting activity should be permitted, which may result in the significant degradation of any water resource.
About half of the water that is treated and distributed at public expense is non-revenue water. This is due to unrecorded usage or illegal taps and water connections. Reducing water losses is cheaper than augmenting water capacity for such losses.
To provide additional supply of water, augmentation of existing water treatment plants is proposed as given in Table 14.2. The actual provision of water treatment plants should be monitored depending on availability of raw water and need of potable water.
Corresponding requirement of land shall be kept in view.
Table 14.1Water Augmentation Plan
S. No
Water Treatment Plants
Capacity 2001 (in mgd)
Capacity* 2021 (in mgd)
1.
Chandrawal I & II
90
100
2.
Wazirabad
120
130
3.
Haiderpur I & II
200
216
4.
Bhagirathi
100
110
5.
Dwarka
-
40
6.
Sonia Vihar
-
140
7.
Nangloi
40
40
8.
Bawana
-
20
9.
Okhla
-
20
10.
Ranney wells at Okhla
100
12
11.
Palla and other ground water sources
-
91
Total
650
919
* Capacity 2021 is as proposed by DJB.
In addition, new water treatment plants may be identified for potable water requirement.
14.3Sewerage
Sewerage is the core element of physical infrastructure that determines the environmental status of any city and requires minute planning, development and management. Development of appropriate sewerage system with efficient sewage treatment is vital to facilitate balanced and harmonized development. Augmentation of existing inadequate systems / treatment facilities as well as adoption of new technologies of waste treatment demands special efforts. Further, it is pertinent to point-out that the existing capacity of sewerage system in Delhi is grossly inadequate, as only about 55% of the population is covered under organised sewerage system and about 15% under on-site sanitation systems. Rest of the population does not have proper access to sanitation facilities. The sewage treatment facility is also inadequate. The increasing pollution in the river Yamuna is a major indicator of lack of sewage treatment facilities.
By the year 2021 entire Delhi should be served by regular sewerage system. It should be developed in a phased manner. The areas where immediate regular sewerage system is not available, low cost sanitation system by individual families could be adopted as a short-range provision. These should be planned in such a way that in the long term regular sewerage could be provided. To improve the sewerage and sanitation, the surface drainage and sewerage systems would have to be developed in an integrated manner.
Planning of the city must incorporate land at appropriate locations for sewage treatment plants (STPs), sewage pumping stations, recycling plants for waste water, sewage treatment plants, common effluent treatment plants (CETPs) with supportive distributive infrastructure i.e. conveyance system to be laid to carry treated wastewater from STPs to the areas for alternative uses. Decentralised STPs with smaller capacities are to be provided at the community / subcity level. Possibility of recovering energy/ gas as fuel from sewage shall be explored.
The liquid waste would be taken care of by augmenting the capacity of existing treatment plants as well as through new sewerage treatment plants. The sewerage system is designed to handle domestic liquid waste @ 80 % of the water supply, which has to cater to 1100 mgd (4950 mld) of waste water by the year 2021. The wastewater is also generated due to the use of ground water drawn from the boreholes installed by the public. The needed capacity has to be
monitored with provision of water recycling infrastructure and mini/decentralised treatments. The treated sewage effluent should be recycled for non-potable uses like gardening, cooling towers, etc. The sewerage augmentation plan is given in Table 14.2.
Table 14.2Sewerage Augmentation Plan
S. No.
Treatment Plant
Capacity 2001 (in mgd)
Capacity* 2021 (in mgd)
1.2.3.4.5.6.7.8.9.10.
Okhla Keshav Pur Nilothi Coronation pillar Rithala Kondli Others a) Sen Nursing Home Nalla STP b) Delhi Gate Nalla STP c) Yamuna Vihar d) Timarpur e) Mehrauli New plants in North Delhi a) Narela / Alipur b) Rohini New plants in West Delhi a) Dwarka / Pappankalan b) Najafgarh New plants in South Delhi a) Vasant Kunj b)Ghitorni c) Badarpur
14072404080452.22.22065101520555-
170727050110902.21745655055405558
Total
512.4
805.2
* Total sewerage treatment capacity based on 80% of water supply of 2011. Capacity 2021 is as proposed by DJB
In addition, new sewerage treatment plants may be identified as per requirement
14.4Drainage
Drainage has two aspects: flood protection and storm water discharge, which are interrelated. The storm water and flood protection in Delhi are not local but have regional bearing including areas of Haryana and Rajasthan. The main drainage system of Delhi is such that all water collected through main drains, link drains and small rivulets is discharged into Yamuna. On the basis of topographical characteristics and existing drainage network, NCT of Delhi has been divided into five drainage basins namely Najafgarh, Alipur, Shahdara, Khushak nallah and Mehrauli. The blockage of natural channel is a matter of concern. It is mainly because of the encroachment by slum dwellers along the drains which causes choking of drains and flooding in the upstream areas due to reduced carrying capacity. The other major reason is dumping of solid waste in the drains causing
blockage. The blockage of natural depressions and drainage channels must be prohibited.
To improve the drainage system of Delhi, effluent treatment plants should be provided at outfall of drains and aeration units at interceptions with advanced techniques for maintenance of drains. A time bound action program for augmentation and capacity revision of existing and new drains (due to increase in run off from urban extensions) is also vital. Check dams and depression/ lakes may be designed for increasing ground water table and as storm water holding points wherever needed. The design shall preserve the natural drainage pattern after the development of an area.
Drainage should be linked with the ecology and green networks, by adopting the concept of “bio-drainage”.
Regular desilting of drains and control of dumping of solid waste / malba into the drains should be taken up. Public awareness program need to be taken up in association with NGOs and RWAs to make the people aware about the consequences of dumping malba in the drains.
Other measures essential for proper drainage are the following:
Drainage to be integral part of Road Development Plans / flyover / Grade Separators.
A proper database should be prepared and GIS based drainage mapping and planning should be promoted.
Sub-wells need to be developed under flyovers for trapping rainwater.
Pump houses in low-lying areas should be provided with back-up power.
Remodelling of selected drains may also be required considering the upstream flow in the region.
14.5Power
The present total availability of power is 3170 MW. The existing power generation stations within Delhi and their capacity are given:
Table 14.3Existing Power generation Stations in Delhi
Station
Installed Capacity (MW)
Present Generation (Max) (MW)
Rajghat Power Station
135
105
IP Power Station
247.5
160
GT Power Station
282
210
Pragati Power Station
330
330
Badarpur Thermal Power Station
705
630
Total
1699.5
1435
Source: GNCT-Delhi
Based on the 17th Electricity Power Survey of India, Central Electricity Authority (CEA), requirement of power for Delhi in the year 2021, as tentatively estimated by the Delhi Transco Ltd. is 11000 MW. To meet the additional requirement of 7830 MW, the concerned agencies need to augment the power supply and improve the transmission and distribution system. The additional power requirement would be met from allocated share from the grid system and local generation for which required land component will be identified. Further, land for transmission network and grid stations will be identified in the Zonal Development Plans / Urban Extension Plans as per requirement. A 400 KV ring has been established around Delhi to draw power from northern regional grid.
A detailed Sectoral Plan for power development in NCT-Delhi may be prepared by the concerned agencies in consultation with DDA within one year after the approval of the MPD-2021.
Table 14.4Proposed Power Plants in NCTD
1.
Pragati-II
330.0
2.
Pragati-III
1000.0
3.
I.P.
700.0
Total
2030
Outside NCTD
Location
Generation
For Delhi
Year of Commissioning
Jhajjar (Haryana) DVC (West Bengal) THDC (Uttranchal)
1500 MW 2600 MW 1000MW
750 MW 2600 MW 600 MW
20102007-112010
TOTAL
3950 MW
2011
The remaining power requirements are proposed to be met from the power projects proposed to be taken up during the 11th Plan period. The Government of NCT of Delhi should enter into power purchase agreements with power generating companies for effectively meeting Delhi’s power demand within a perspective plan framework.
The erstwhile Delhi Vidyut Board (DVB) has been re-structured into separate companies for generation, transmission and distribution of power.
Following critical areas need to be attended for energy efficiency:
i) The concept of energy efficiency should begin with the idea of Zero-fossil Energy Development (ZED) which envisages an urban form and design of passive building envelope that reduce the demand for power to the point where it becomes economically viable to use energy from renewable resources. This involves a holistic approach combining the issues and actions at various levels of planning, design, construction and maintenance leading to a sustainable and energy efficient regime. The city geometry, restructuring and zoning with self-contained neighbourhoods could minimise the need to travel and substantial saving of recurring energy/ fuel
consumption. Integrated mass transport system, traffic and transit operation and management, better tele-communications, promoting bicycles and NMV transport, is another major area of energy efficient habitat. The introduction of energy audit and design of energy efficient buildings by site planning, heights, form, construction and materials and reducing energy demand by passive micro-climatic design approach, intelligent energy controls, heat recovery, landscape, opening design, furnishings, etc., are the critical considerations. The key to future is a cybernetic form of sustainable energy, which integrates symbosis, recycling and energy chains.
ii) Load management techniques and energy accounting should be adopted. Schemes to minimise power thefts/ losses by improved metering arrangements should be enforced.
iii) Non-conventional energy sources like recovering energy from sewerage, solar energy, etc. should be used for street lighting, lighting at public spaces, open areas, traffic signals, hoardings, etc.
iv) To supplement part of the estimated growing power requirement, non-conventional sources / solar energy and other actions proposed are as follows:
Solar energy should be encouraged for all establishments with floor area of more than 300 sqm.
Solar Panels for public advertising, lighting in open areas, public utilities, streets, etc.
As alternate mandatory arrangement during power cuts to replace generators/inverters etc.
Adoption of Load Management Technique.
Tariff restructuring and improved metering arrangement to minimize power thefts/losses.
Interim solutions of single point connection in unauthorized colonies and jhuggies.
Private Sector Participation in different stages of Power generation, transmission and distribution.
Incentivising energy savings and use of energy efficient gadgets.
Public awareness, capacity building and training.
As per Asian Development Bank’s report (1997) potential in saving due to better overall efficiency in domestic sector is about 20% by adopting following measures:
14.6Solid Waste
The problem of solid waste management in Delhi is assuming serious proportions due to increasing population, urbanisation, changing lifestyles and consumption patterns. The garbage from unauthorised developments, slums, JJ settlements, etc is not collected which further adds to the environmental degradation. The projected average garbage generation upto the year 2021 is @ 0.68 kg per capita per day and total quantum of solid waste is 15750 tons/day as given in Table 14.5.
Table 14.5Quantum of Municipal Solid Waste (Tons/Day)
Local body area
Existing capacity2001
Projected generation for 2021
MCD
5250
15100
NDMC
245
550
Cantonment
48
100
Total
5543
15750
Management of solid waste involves waste generation, segregation and storage; waste collection; waste transfer/ transportation; treatment, recycle, reuse, recovery; and disposal. For effective waste management, its segregation at the community and neighbourhood level is imperative. The waste shall be segregated and collected, in separate chambers at dhalaos. For this, involvement of rag pickers with RWAs, CBOs and NGOs is to be encouraged.
The projected composition of municipal waste for the Plan period is estimated as given in Table 14.6. For biodegradable and recyclable waste, which is segregated at the source, decentralised treatment at neighbourhood level may be adopted, while for non-biodegradable, centralised treatment may be followed.
Table 14.6Projected Composition of Total Municipal Solid Waste for 2021
Constituents
Quantum (in tones)
Percentage to total waste
Bio-degradable
6000
38
Non Bio-degradable
6000
38
Recyclable
3750
24
Total
15750
100
(i) Above figures are based on Report on Solid Waste Management in Delhi conducted by NEERI, Nagpur through DDA;
(ii) Figures of MCD are based on ‘Feasibility study in Master Plan for Optimal Waste Treatment & Disposal for the entire State of Delhi’ June, 2004 by COWI Consultants appointed by MCD.
The other type of specialised waste includes biomedical waste; hazardous waste from industries; construction debris and fly ash; meat processing centre etc. Disposal of bio-medical waste is to be as per bio-medical waste rules and hazardous waste requires special handling according to hazardous waste handling rules. Proper dumping, recycling and reuse of construction debris and fly ash have to be linked. Meat processing centre waste is to be recycled for chicken feed etc.
Considering the nature of solid waste and the economic aspects of its disposal, major part of solid waste especially non bio-degradable has to be disposed off in sanitary landfills. Recycling should be preferred than disposing off the waste in sanitary landfill sites’ wherever possible. The segregation of solid waste should start at the point of generation of the waste. It should be collected in two separate bags of green and black colour. The involvement of RWAs and Rag pickers association will reduce the quantum of waste drastically. And it will also result in the reduction of area required for landfill sites.
Further, some more viable alternatives to landfills are vermiculture, fossilisation, composting etc. Waste Minimisation Circles (WMCs) should be constituted and made effective. Implementation and monitoring & Bio-Medical Wastes (Handling & Management) Rules, 1998, for hospitals, 1[tertiary health care centres,] nursing homes, and clinics should be taken up. The sites, which are filled up or are in operation, are given in Table 14.7. The filled up sites may be reused for plantation or as recreational area. The proposed sites for sanitary landfill and compost plants are to be finalised by the MCD.
Table 14.7Existing Landfill sites for Waste Management
S. No.
Location
Area (in ha.)
Remarks
1.
Kailash Nagar, East Delhi
1.8
Filled up
2.
Tilak Nagar, West Delhi
16.0
Filled up
3.
Subroto Park
-
Filled up
4.
Purana Qila/Bharion Road
2.7
Filled up
5.
Timarpur
16.0
Filled up
6.
Sarai Kale Khan
24.0
Filled up
7.
Gopal pur
4.0
Filled up
8.
Chhaterpur
1.7
Filled up
9.
S.G.T. Nagar
14.4
Filled up
10.
I.P. Deoit
1.8
Filled up
1 Added vide S.O. 2893(E) dated 23-09-2013
11.
Sunder Nagar
2.8
Filled up
12.
Tuglakabad Extension
2.4
Filled up
13.
Haider Pur
1.6
Filled up
14.
Mandawali Fazilpur
2.8
Filled up
15.
Rohini Phase III
4.8
Filled up
16.
Near Hastal Village in West Delhi
9.6
Filled up
17.
Site near Ghazipur Dairy Farm
28.0
In operation
18.
Site near Jhangipur / Bhalswa
16.0
In operation
19.
Okhla Phase I
12.8
In operation
20.
Crossing on G.T. Karnal Road
3.2
In operation
21.
Jaitpur / Tajpur
9.84
New
22.
Near Puthkhurd
55.0
New
23.
Bawana to Narela Road
28.0
New
24.
Sultanpur Dabas (Bawana)
16.0
New
Appropriate land should be earmarked for solid waste management keeping in view a long-term perspective.
The area required for solid waste disposal through various technologies including sanitary landfill sites shall be reserved in the Zonal Plans. This shall also include buffer zone of ‘no development’ around landfill sites. Keeping in view the fact that finding new sanitary landfill sites in Delhi is becoming extremely difficult, there is no option, but to resort to alternative and decentralised methods of waste treatment, reduction, recycle and use, which include vermiculture, fossilisation and composting. Pilot projects in this regard have been taken up by the MCD with the consultants.
--- x---x---x---x---x---
15.0 Mixed Use Regulations
The policy acknowledges the need for permitting use of land for purposes other than that for which it was originally envisaged and lays down the conditions under which this may be applied in different situations. The general procedure to be followed for implementation of the said policy, and mitigating measures to be taken to counter the effect of such non-intended use in such area also described.
15.1Governing Principles for Mixed Use
i) Mixed use means the provision for non-residential activity in residential premises.
ii) The policy aims to balance the socio-economic need for such activity and the environmental impact of the said activity in residential areas.
iii) Mixed use allows access to commercial activities in the proximity of the residences and reduces the need for commuting across zones in the city. However, at the same time, it needs to be regulated in order to manage and mitigate the associated adverse impact related to congestion, increased traffic and increased pressure on civic amenities.
iv) The over-riding principles for permitting mixed use are the need to acknowledge and make adequate provision for meeting community needs, mitigating environmental impact and providing for safe and convenient circulation and parking.
v) Mixed-use, (including small shops as per para 15.6.3.) shall not be permitted in the Lutyens' Bungalow Zone, Civil Lines bungalow zone, government housing, institutional / staff housing of public and private agencies and buildings / precincts listed by the Heritage Conservation Committee.
15.2Mixed Use in Residential Areas
15.2.1 Differentiated Approach
i) The need for differentiated approach to mixed use policy arises from the fact that Delhi, being the country's capital and an important centre of economic activity has a large diversity in the typology of residential areas. Apart from the planned residential colonies built as part of Lutyens' Delhi as well as through the process of planned development undertaken by the Delhi Development Authority, there are authorized residential areas in the Walled City, Special areas and urban villages. Other planned areas include resettlement colonies and pre-Delhi Development Act colonies, including post-partition rehabilitation colonies and pre-1962 residential colonies as per list given in Annexure-I. There are also regularized-unauthorized colonies; unauthorized colonies as well as slums and jhuggi jhompri clusters in various parts of Delhi.
ii) Moreover, the extent of non-residential activity seen as being necessary or desirable by the residents themselves varies from area to area based on the socio-economic status of the residents as well as the past pattern of development in that area. While certain colonies may need non-residential activity as an integral part of their livelihood, some others may wish to preserve the residential character of their colonies and neighbourhood.
iii) Hence, it is proposed to follow a differentiated approach in the application of the mixed-use policy in Delhi. The differentiated approach would be based on categorization of colonies from A to G as adopted by 1[concerned municipal body] for unit area method of property tax assessment as applicable on 7.9.2006. Any change in the categorization of these colonies shall not be made applicable for the purpose of this chapter without prior approval of Central Government.
15.2.2 Types of Mixed Use
Subject to the provisions of this chapter, the following three broad types of mixed use shall be permissible, in residential premises:
i) Commercial activity in the form of retail shops as per conditions given in para 15.6 in plots abutting notified mixed use streets.
ii) "Other activity" broadly in the nature of 'Public and Semi-Public' facilities listed in para 15.7.1 and as per conditions specified in para 15.7, in plots abutting roads of minimum ROW prescribed in para 15.3.2.
iii) Professional activity as per conditions specified in para 15.8.
The above mentioned types of mixed use shall be subject to the general terms and conditions specified in the succeeding paragraphs.
15.3Identification of Mixed Use Areas in Existing Urban Areas and Urbanizable Areas
The identification of mixed use areas / streets in both the urbanized / urban as well as urbanizable areas of Delhi would be as follows:
15.3.1 In already urbanized / urban areas, mixed use shall be permissible in the following areas:
i) On all streets / stretches already notified by the competent authority.
ii) Residential areas and streets / stretches earlier declared as commercial areas / streets or where commercial use was allowed in MPD-1962 shall continue such use at least to the extent as permissible in MPD-1962.
1 Modified vide S.O. 3173(E) dated 12-12-2014
iii) Commercial activity existing from prior to 1962 in residential areas, subject to documentary proof thereof.
iv) Identification and notification of mixed use streets in future shall be based on the criteria given in para 15.3.2 and as per procedure prescribed in para 15.3.3, and given wide publicity by the local bodies concerned.
v) Plotted development in pre-1962 colonies listed in Annexure I shall be treated as rehabilitation colonies in their respective categories (A to G) for the purpose of this Chapter.
15.3.2 The extent of mixed use permissible in various categories of colonies is further clarified as follows:
1. In colonies falling in categories A and B
No commercial activities will be permissible in the colonies of A & B categories except the following:
Professional activity, subject to conditions given in para 15.8, mixed use and commercial activity up to one plot depth, in plots abutting Master Plan roads that are notified as mixed use streets, and commercial streets respectively, since such roads are not internal to the colonies (provided that the request of the RWA concerned shall not be necessary for notifying the Master Plan roads abutting the colonies, as mixed use streets on commercial streets).
1["Other activity" restricted to guest houses, nursing homes and pre-primary schools, as defined in para 15.7.1, subject to conditions contained in para 15.7, in plots abutting roads of minimum 18m ROW in regular plotted development, since these activities are in the nature of 'Public and Semi-Public' facilities. New banks 2{.} and NGOs will not be permissible. Banks which existed as on 7.9.2006 and NGOs which existed as on 7.2.2007, fitness centres and wellness centres 2{.} (as defined in para 15.7.1), in accordance with notifications issued in this regard from time to time, and are on plots abutting roads of minimum 18m ROW, on the date of notification, shall however, continue.]
Retail shops in terms of para 15.6 on such mixed use streets with a minimum 18m ROW, within the colony, in regular residential plotted development, as are notified in terms of para 15.3.3, if there is a specific request of the RWA concerned, in terms of para 15.10.
1 Substituted vide S.O. 2034(E) dated 12-08-2008
2 Deleted vide S.O. 1090 (E) dated 16-03-2020
Commercial activity on mixed use streets, within A & B category colonies, earlier notified under MPD-2001 shall cease with immediate effect (other than in plots abutting Master Plan roads).
2. In colonies falling in categories C & D
Mixed use in the form of Retail shops shall continue to be permissible as per conditions in para 15.6, in plots abutting notified mixed use streets.
"Other activity" in terms of para 15.7 shall be permissible in plots abutting roads of minimum 18m ROW in regular plotted development, 13.5m ROW in rehabilitation colonies and 9m ROW in Walled City, regularized -unauthorized colonies, resettlement colonies, Special Areas, and urban villages, subject to conditions in para 15.7.
Notification of mixed use streets in future, of minimum 18 m ROW in regular residential plotted development, 9 m ROW in rehabilitation colonies and any road in regularizedunauthorized colonies, resettlement colonies, Walled City, Special Area and urban villages in terms of para 15.3.3 shall be subject to consultation with RWAs concerned in terms of para 15.10.
Mixed use shall be permissible in pedestrianized shopping streets as per para 15.3.3.
Professional activities shall be permissible as per conditions laid down in para 15.8.
3. In colonies falling in categories E, F and G
Retail shops shall continue to be permissible as per conditions in para 15.6., in plots abutting notified mixed use streets.
"Other activity" in terms of para 15.7 shall continue to be permissible in plots abutting roads of minimum 13.5m ROW in regular plotted development, 9m ROW in rehabilitation colonies and any road in Walled City, regularized-unauthorized colonies, resettlement colonies, Special areas, and urban villages subject to conditions in para 15.7.
Professional activities shall be permissible subject to conditions in para 15.8.
Notification of mixed use streets in future, of minimum 13.5m ROW in regular residential plotted development, 9m ROW in rehabilitation colonies and any road in regularizedunauthorized colonies, resettlement colonies, Walled City, Special Area and urban villages shall be in terms of para 15.3.3.
Mixed use shall be permissible in pedestrianised shopping streets as per para 15.3.3.
4. Group housing in all categories of colonies
- ¹[Only professional activity, small shops in terms of para 15.6.3 and tution centres for school children only shall be permissible. Retail shops specifically provided for in the lay out plan of group housing under para 15.4(ii) would be permissible.] ²[In case of Employer Housing (government housing, institutional/ staff housing of public and private agencies), the use activities permitted in Table 4.3 for ‘Residential Plot- Group Housing’ will be allowed as part of the approval of the Layout Plan. Non-residential activity will not be permitted within residential plot/ flat.]
5. In respect of colonies falling in NDMC area
Excluding Lutyens' Bungalow Zone, government housing, institutional and staff housing of public and private agencies and buildings / precincts listed by the Heritage Conservation Committee, existing mixed use streets / stretches will be notified by NDMC. Future notification of mixed use streets / stretches will be done on a field level survey to assess the community needs, environmental impact and traffic circulation/ adequate parking and in consultation with Residents Welfare Associations concerned.
15.3.3 Notification of Mixed Use Streets in Urban Areas
i) 3[Where more than 50% of the plots in a stretch / street, are having shops / offices and other activities permitted in Local Shopping Centres on ground floor, such streets / stretches shall be eligible for notification as mixed use street.]
ii) The minimum ROW for identification of a street or stretch of road as mixed use street would be follows*:
In A & B Colonies
In C & D colonies
: 18m ROW in regular plotted development on the specific request of RWAs.
: 18 m ROW in regular residential plotted development, 9 m ROW in rehabilitation colonies and any road in regularized-unauthorized colonies, resettlement
¹ Substituted vide S.O. 2034(E) dated 12-08-2008
² Added vide S.O. 678(E) dated 04-03-2014
³ Substituted vide S.O. 2034(E) dated 12-08-2008
colonies, Walled City, Special area and urban villages; in consultation with RWA concerned.
In E, F & G Colonies : 13.5m ROW in regular plotted development, 9m ROW in rehabilitation colonies and any road in Walled City, regularized-unauthorized colonies, resettlement colonies, Special Areas, and urban villages.
* Provided that consistency shall be maintained by the local body in determining the ROW whether the street is bordered by service road, green verge, park or not.
iii) Streets of less than 6 m ROW notified as mixed use streets or as commercial streets, in regularised-unauthorised colonies, resettlement colonies, Special Area, urban villages, will be declared as pedestrian shopping streets (PSS) and will not be open to motorized transport.
a) Request of the RWA concerned or consultation with RWAs concerned, shall not be necessary for notifying the Master Plan roads abutting the colonies as mixed use streets, since such roads are not internal to the colonies.
b) Specific request of or consultation with RWA concerned shall be governed by Para 15.10.
iv) For the notification of mixed use streets, in areas that have not been surveyed or have been surveyed but streets have not been notified pursuant to notification dated 7.9.2006, local bodies shall be required to carry out within a reasonable time of the notification coming into force, and with due expedition, and not later than 90 days, a survey of all streets of the above-mentioned width, if not already done, with a view to identifying stretches of such streets as mixed use streets.
1[Note-1: The local body shall carry out a survey in those streets / roads in urban villages and regularized-unauthorized colonies not surveyed pursuant to the provisions of MPD-2021 notified on 7.2.2007, within a period of three months of this Notification.]
v) The field survey shall assess the extent of existing non-residential use on the streets, the stretch of the street to be notified, the
1 Added vide S.O. 2034(E) dated 12-08-2008
15.3.4 Notification of Mixed Use Streets in Urbanisable Areas in Future
In new urbanisable areas, mixed use shall be permissible in the following areas:
In newly developed residential areas, mixed use as specified above shall be permitted only on residential plots abutting 18m. ROW roads.
The layout plan in newly developed urban extension shall earmark such stretches / plots and notify them under the mixed use policy at the time of grant of permission for layout plan in the case of private development and at the time of disposal by allotment or auction in the case of areas developed by DDA.
iii) In the Abadi area of villages in urbanisable area, mixed use shall be permissible as per the provisions of urban villages and for this purpose, local bodies shall be required to carry out within a reasonable time of the notification coming into force, and with due expedition, and not later than 90 days, a survey of all streets of the above-mentioned width, if not already done, with a view to identifying stretches of such streets as mixed use streets.
15.4General Terms and Conditions Governing Mixed Use
In terms of the conditions prescribed for different categories of colonies, in para 15.3.2, and provided that the plot abuts a notified mixed use street (in the case of retail shops) or a road of prescribed minimum ROW (in the case of other mixed use activities), mixed use shall be permitted, subject to the following general terms and conditions:
In residential plotted development
i) Where there is only one dwelling unit in a residential plot, only one type of mixed use (i.e. retail shop as per para 15.6 or professional activity or one of the other activities listed in para 15.7) shall be permissible in that unit.
ii) Where there are more than one dwelling units in a residential plot, each of the dwelling units will be permitted to have only type of mixed use activity
(either retail shop as per para 15.6. or professional activity or any one of the other activities listed in para 15.7).
In group housing
Only professional activity and small shops in terms of para 15.6.3 shall be permissible. Retail shops specifically provided for in the lay out plan of group housing would be permissible. ¹ [However, the entire ground floor of DDA flats on mixed use / commercial use area / stretches / roads is allowed for mixed use / commercial use ² {as notified vide S.O. 2034(E) dated 12.08.2008. Whereas w.e.f. 25.09.2013 only one retail shop of maximum size of 20 sqm is permitted and rest of the area may be used for professional activity.} No amalgamation of two or more DDA flats shall be allowed.]
Other terms and conditions
i) No encroachment shall be permitted on the streets or public land.
ii) Development control norms as applicable for the particular residential use will continue to be applicable, even if the plot / dwelling unit is put to mixed use.
iii) If the notified street is a Master Plan road, and if a service road is available or provided for by local bodies, then, the mixed use premises should be approached from such service road and not directly from the main carriageway.
iv) In plotted development, front setback should not have boundary wall, so that it can be used for additional parking.
v) Parking @ 2.0 ECS per 100 sqm built up area shall be provided within the premises. ³[Residents/ traders' organizations/ private parties shall be responsible for providing for their own private parking facilities.] This condition shall apply even if residential premises are used only for professional activity.
vi) Common parking areas would be earmarked ³ [by the concerned local bodies] on notified mixed use streets taking into account the additional load on traffic and parking consequent upon notification of the street under Mixed Use Policy. If no parking space is available, land/ plot on the said street may be made available by ³ [the concerned traders/ establishments, and public shared parking facilities provided before approval/ notification of the said building/ project/ street as mixed-use.]
⁴ [vii] Issues related to mixed-use streets for which conversion charges have already been levied by local bodies needs to be addressed by the concerned local body.]
¹ Added vide S.O. 2034(E) dated 12-08-2008
² Added vide S.O. 678(E) dated 04-03-2014
³ Modified vide S.O. 1914(E) dated 14-07-2015
⁴ Added vide S.O. 1914(E) dated 14-07-2015
15.5 Permissible and Non-permissible Uses
Any trade or activity involving any kind of obnoxious, hazardous, inflammable, non-compatible and polluting substance or process shall not be permitted.
15.6$^{1}$ [retail Shops and Offices]
15.6.1 ² [(i) Retail shops and Offices shall be permitted on plots abutting streets notified for mixed use only on the ground floor upto the maximum permissible ground floor coverage.
(ii) Mixed use from basement on such streets may be allowed, subject to relevant provisions of building bye-laws, structural safety and fire safety clearance. However, if such use of basement leads to exceeding the permissible FAR on the plot, such FAR in excess shall be used, subject to payment of appropriate charges prescribed with the approval of Government. Paras 15.3.2.1, 15.3.2.2., 15.3.2.3, 15.3.3(i) and 15.4 and any other relevant provisions shall be read along with the above provisions.]
15.6.2 The following activities shall not be allowed under Mixed Use:
a) Retail shops of building materials [timber, timber products (excluding furniture), marble1, iron and steel, (gravel, cement and sand2], firewood, coal and any fire hazardous and other bulky materials.
b) Repair shops / workshops of automobiles, tyre resolving and retreading, and battery charging.
c) Storage, go-down and warehousing.
d) Junk shop (except paper and glass waste)
e) Liquor shop
f) Printing, dyeing and varnishing
g) Any other activity that may be notified from time to time by Government.
Will not include:
Business of finished marble products where cutting and polishing activity of marble is not undertaken 3[will be permitted only on residential plots of minimum 100 sqm size abutting ROW of 18m and above. The maximum permissible ground coverage shall be 50%
Retail shops of gravel, sand and cement shall be permissible in residential plots of at least 100 sqm abutting ROW of 18m and above in notified mixed use streets in E, F and G category colonies,
¹⁻² Modified vide S.O. 2034(E) dated 12-08-2008
³ Added vide S.O. 2789 (E) dated 24-08-2016
provided that the material is kept entirely within the plot premises. The maximum permissible ground coverage shall be 50%. The shops which were in existence in consonance with MPD-2021 provisions prior to notification of this amendment shall be allowed to continue.]
Repair shops and workshops in case of automobiles shall not be prohibited on plots abutting mixed-use streets or commercial streets of right of way (ROW) of 30m or more.
15.6.3 1[Small shops of maximum 20 sqm area each, restricted to maximum permissible number of DUs in the plot or four numbers, whichever is less, trading in or dealing with the following specified 24 items / activities are allowed on ground floor only in residential plot, excluding A & B category of colonies. However, small shops of maximum 20 sqm area each, restricted to maximum permissible number of dwelling units in the plot or four in number, whichever is less, trading in or dealing with specified items / activities existing as on 7.2.2007 may continue on ground floor only in a residential plot in A & B category of colonies but in future only one small shop of 20 sqm area shall be allowed on ground floor in a residential plot in A & B category of colonies.]
Any other item / activity that may be notified by the Central Government.
15.7Other Activity
15.7.1 Subject to the general conditions given in para 15.4 and additional conditions given in para 15.7.3, the following public and semi-public activities shall also be permitted in the residential plots abutting roads of minimum ROW prescribed in 15.7.2, whether or not the road is notified as mixed use street:
a. Pre-primary school (including nursery / Montessori school, creche.)
b.
i) Nursing home
ii) Clinic, Dispensary, Pathology lab and Diagnostic center.
iii) 1[Wellness Centers including Day Spas / Weight Loss Centres / Ayurvedic Centres offering Ayurvedic treatment / Salons offering fitness & aesthetic medical services 2{.}]
c. Guest house (including lodging houses) irrespective of number of rooms.
d. Bank
e. Fitness Centre (including gymnasium, yoga / meditation centre) ².
f. Coaching centres / tuition centres other than those imparting structured courses leading directly to the award of a degree or diploma or conducting classes such as a regular school.
g. ³[Non-profit making Non-Governmental Organizations (NGOs) existing as on 7.2.2007 and registered as such under Section 12A read with Section 12AA(1)(b) of the Income Tax Act, 1961.]
h. ⁴ [Vocational Training Centre (ITI / Polytechnic / Vocational Training Institute / Management Institute / Teacher Training Institute for the AICTE / NCTE approved courses (diploma level) as per AICTE / NCTE Norms.]
i. ⁵ [Hostel/ paying-guest accommodation]
j. ⁶ [Other activities which are non-polluting, non-hazardous and not prohibited by law in residential areas shall be permitted. This shall include the activities carried out by the differently-able persons as per their individual skill sets.]
¹ Added vide S.O.2034 (E) dated 12-08-2008
² Deleted vide S.O. 1090 (E) dated 16-03-2020
³ Added vide S.O.2034 (E) dated 12-08-2008
⁴ Added vide S.O. 678(E) dated 04-03-2014
⁵ Added vide S.O. 2690 (E) dated 11-08-2016
⁶ Added vide S.O. 3026 (E) dated 21-06-2018
1 [Notes:
Banks lockers if part of existing bank shall be allowed in the respective basements of same premises.]
15.7.2 The minimum ROW of a street or stretch of road on which the above-mentioned other activities are permissible is as follows:
In A & B Colonies*: 18m ROW in regular plotted development;
* Banks ²[...] shall however, not be permissible, except those already operating as on 07.09.06.
In C & D colonies: 18 m ROW in regular residential plotted development, 13.5 m ROW in rehabilitation colonies and 9 m ROW in regularized-unauthorized colonies, resettlement colonies, Walled City, special area and urban villages; and in pedestrian shopping streets ( of less than 6 m ROW).
In E, F &G Colonies: 13.5 m ROW in regular plotted development, 9 m ROW in rehabilitation colonies and 6m ROW in Walled City, regularized- unauthorised colonies, resettlement colonies, Special areas, and urban villages and in pedestrian shopping streets (of less than 6m ROW).
³ [Note: Coaching centres / tuition centres shall also be allowed to operate on a minimum ROW of 9m unless lesser ROW is specified, in all colonies planned and developed prior to 1962 including A and B category colonies.]
15.7.3 ⁴ [The above mentioned public and semi-public activities shall be subject to the following overriding conditions on the general conditions prescribed in preceding paras:]
i) Subject to the specific conditions mentioned in succeeding paras, the minimum size** of the plot on which these activities shall be permissible, on streets of prescribed minimum ROW, shall be 200 sqm in regular plotted development, 75 sqm in rehabilitation
¹ Added vide S.O. 3844 (E) dated 24-10-2019
² Deleted vide S.O.2034 (E) dated 12-08-2008
³ Added vide S.O.2034 (E) dated 12-08-2008
⁴ Modified vide S.O.2034 (E) dated 12-08-2008
iv)
colonies, regularized - unauthorized colonies, resettlement colonies, Walled City, Special Area & urban villages subject to the following specific conditions.
ii) 1[Banks shall be permissible on maximum 2/3rd of FAR subject to 600 sqm while guest house, nursing homes, Wellness Centres including Day Spas / Weight Loss Centres / Ayurvedic Centres offering Ayurvedic treatment/salons offering fitness & aesthetic medical services will be permissible upto 3/4th of the floor area.]
iii) Nursing Homes, dispensaries, clinics, 2[Wellness Centres including Day Spas/ Weight Loss Centers/ Ayurvedic Centres offering Ayurvedic treatment/ Salons offering fitness & aesthetic medical services,] 3[Multidisciplinary Clinics for persons with Learning Disabilities (facilities for care of the elderly and disabled shall be permissible under this category)] and pathology labs shall be permissible: on minimum plot size of 100 sqm in regular plotted development on 13.5 m ROW in C & D colonies and 9 m ROW in E, F & G colonies. 4[However, the minimum plot size shall be 50 sqm for clinics, dispensaries and pathology labs shall be permissible: on minimum plot size of 100 sqm in regular plotted development on 13.5 m ROW in C & D colonies and 9 m ROW in E, F & G colonies.] However, the minimum plot size shall be 50 sqm for clinics, dispensaries and pathology labs running in these colonies and also in E, F and G category colonies. In Walled City, Walled city extension, villages and unauthorized-regularized colonies, conditions of plot size and minimum ROW shall not be applicable.]
Nursing Homes, 5[Wellness Centres including Day Spas / Weight Loss Centres/ Ayurvedic Centres offering Ayurvedic treatment / Salons offering fitness & aesthetic medical services] operating in plots abutting Master Plan roads and Zonal Plan roads shall be permissible up to 100% of built up area and the limit on the size of the plot would not apply. 6[New wellness centre from the date of notification shall only be allowed on ground floor and basement.]
v) Guest Houses operating in plots abutting streets of prescribed minimum ROW in Special Area and in plots abutting Master Plan roads and Zonal Plan roads shall be permissible up to 100% of built up area and the limits on the size of the plot shall not apply. Provided that except in LBZ and Civil Line Bungalow Zone, Guest House that were operating validity under provisions of 7[MPD],
¹ Substituted vide S.O. 2034 (E) dated 12-08-2008
² Inserted vide S.O. 2034 (E) dated 12-08-2008
³ Added vide S.O. 2866(E) dated 10-12-2012
⁴ Added vide S.O. 2866(E) dated 10-12-2012
⁵ Inserted vide S.O. 2034 (E) dated 12-08-2008
⁶ Added vide S.O. 1090 (E) dated 16-03-2020
⁷ Modified vide S.O. 1998 (E) dated 03-06-2016
vi)
prior to ¹ [31.12.2010 would continue to the extent as was permissible at that time. For Guest Houses, which were already in existence prior to 07.02.2007, the requirement of RoW would be as provided for in notification dated 07.05.1999 subject to the provisions of the National Building Code, Building Bye Laws, 1983, Delhi Fire Service Act, 2007, Delhi Fire Service Rules, 2010 and other statutory bodies as applicable under relevant Acts/ Rules.]
² [Pre-primary school (other than those on plots abutting commercial streets) shall be restricted only to the ground floor upto the permissible ground coverage. Fitness Centre (including Gymnasium, Yoga / Meditation Centre), 3 · is permitted on all floors. It is also permitted in the basement subject to relevant provisions of Building Bye Laws, structural safety norms and fire safety clearance. In case the use of basement leads to exceeding the permissible FAR on the plot, such FAR in excess shall be used subject to payment of appropriate charges prescribed with the approval of Government.] ⁴ [New fitness centre from the date of notification shall only be allowed on ground floor and basement.]
vii) 5[Coaching centres and tuition centres referred to in para 15.7.1 (f) including computer coaching and language coaching centres shall be permissible upto 2/3rd of the maximum permissible FAR of the plot size subject to a maximum of 500 sqm built area and basement. There shall be no restriction on the size of the plot. Use of basement shall be subject to clearance from the fire authorities and other statutory bodies as per the relevant provisions of MPD 2021 and Unified Building Bye-Laws, 1983, amended from time to time. In case the use of basement for coaching centres and tuition centres including computer coaching and language coaching activity leads to exceeding the permissible FAR on the plot, such FAR in excess shall be used subject to payment of appropriate charges prescribed with the approval of Government. Other existing coaching/tuition centres may be allowed to continue till end of May, 2008 and shift to conforming locations by then. The tuition centres for school children only, shall also be permissible in the ground floor dwelling of any group housing on a maximum floor area of 100 sqm or 50% of the floor area of the flat, whichever is less.]
viii) The above mentioned activities shall also be subject to any other specific terms and conditions, as may be prescribed in the relevant statutes / acts applicable to them.
¹ Modified vide S.O. 1771(E) dated 12-05-2016
² Substituted vide S.O. 2034 (E) dated 12-08-2008
³ Deleted vide S.O. 1090 (E) dated 16-03-2020
⁴ Added vide S.O. 1090 (E) dated 16-03-2020
⁵ Modified vide S.O.2034 (E) dated 12-08-2008
ix) It shall be the responsibility of the plot allottee / owner to make arrangements for parking so that the parking does not encroach / spill over on public land.
x) ¹ [NGOs as referred to in Clause (g) of Sub-para 15.7.1, if not registered as yet, should get themselves registered within one year from the date of Notification. Activities of NGOs will be allowed to continue only from that part of the premises which was in use as on 7.2.2007 without permitting any further increase subject to the condition that it is less than 3/4th of the floor area.]
xi) ² [The activity given in Para 15.7.1 (h) shall be permitted on individual residential plots of size 1000 sq.m. and above.]
**Variation of ± 5% in plot size may be disregarded.
15.7.4 Banquet Hall
Banquet Hall shall also be permissible in industrial and commercial areas including notified commercial streets under Mixed Use Regulations. Development control norms in respect of ground coverage, FAR, height and basement shall be applicable as per master plan norms for the specific land use for that premises till specific regulations are notified for this purpose.
³ [15.7.5] Restaurants on ground floor only with valid appropriate licenses and with all statutory clearances, as existing on or before the date of notification shall only be permissible on notified mixed use streets.]
15.9Registration of Mixed Use Premises and Payment of Charges
(i) In respect of a residential premises already under mixed use or intended to be put to mixed use, the owner / allottee / resident of the plot / dwelling unit, in case of plotted development and dwelling unit in the case of group housing, shall be required to declare such mixed-use by filling up a form in this respect and depositing it with the local body concerned any pay one-time registration charges at rates to be notified with the approval of the Central Government.
(ii) The premises under mixed use shall also be liable for payment of mixed-use charges every Year to the local body concerned at the rates notified with the approval of Central Government, for the period during which the property is put to mixed use. Such payment will be made by the property owner / allottee voluntarily before 30th June of every year in respect of the previous assessment year (April - March).
(iii) No modification to the building for using residential premises for non-residential activities, under the mixed use policy, shall be permitted unless the allottee / owner has obtained sanction of revised building plans and has paid necessary fees or charges.
(iv) The local body concerned shall be responsible for the conduct of test check of properties under mixed use, whether registered with it or not.
¹ Added vide S.O.2034 (E) dated 12-08-2008
² Added vide S.O.1135 (E) dated 14-05-2008
³ Deleted vide S.O.3844 (E) dated 24-10-2019
(v) ¹ [In addition to other penal action available under the relevant act, properties found to be under mixed use, without registration or in violation of the terms of this notification shall be liable to pay, to the local body, a penalty ² {as prescribed with the approval of Government.}]
(vi) ³[In respect of residential premises already under mixed use on 7.2.2007 in Special area, the owner / allottee / occupier of the plotted development shall be required to declare such mixed use by filling up a form in this respect and depositing it with local body concerned and pay one time registration charges and conversion charges without penalty on or before 30.6.2009 at the rate to be notified with the approval of the Government from time to time.]
15.8Professional Activity
Subject to the general terms and conditions specified in para 15.4, professional activity is permissible in plotted development and group housing under the following specific conditions:
(i) Professional activities shall mean those activities involving services based on professional skills namely Doctor, Lawyer, Architect, and Chartered Accountant, Company secretary, Cost and Works Accountant, Engineer, Town Planner, Media professionals and Documentary Film maker, Management Professionals* 4[and Dietician/ Nutritionists.]
(ii) In group housing, and plotted development with multiple dwelling units, professional activity shall be permitted on any floor subject to maximum of
¹ Added vide S.O.2034 (E) dated 12-08-2008
² Added vide S.O. 678 (E) dated 04-03-2014
³ Added vide S.O.3844 (E) dated 24-10-2019
⁴ Added vide S.O. 2789 (E) dated 24-08-2016
50% of the permissible or sanctioned FAR, whichever is less, of each dwelling unit.
(iii) In the case of plotted development with single dwelling unit, professional activity shall be permissible on any one floor only, but restricted to less than 50% of the permissible or sanctioned FAR whichever is less on that plot.
(iv) 1[Professional activity in basements is permissible in plotted development, subject to relevant provisions of Building Bye-Laws, structural safety norms and fire safety clearance. In case, the use of basement for professional activity leads to exceeding the permissible FAR on the plot, such FAR in excess shall be used subject to payment of appropriate charges prescribed with the approval of Government.]
² [Note : * Management professional shall be the one holding MBA degree / diploma from AICTE / UGC / Centrally recognized institutions or institutes of national importance and having membership of Delhi Management Association.]
15.10Consultation with RWAs
(i) The Residents Welfare Association (RWA) shall be a body registered before 21.07.06, or registered for at least three years under any statute, such as Societies Registration Act.
(ii) Consultation with the RWA concerned for the purposes of declaring mixed use streets shall be done by the local bodies concerned.
(iii) Genuine efforts for meaningful consultation with RWAs shall be made by the local bodies. Such efforts may include wide publicity to the proposed consultations, maintenance of record of consultation and providing access to those records to RWA concerned and public.
(iv) Consultation with the RWA concerned shall be limited to identification of mixed use streets, and not for grant of permission in individual cases. However, RWAs shall have a right to be heard in cases of complains of public nuisance and non-permissible uses.
15.11Conditions for Denial / Withdrawal / Restrictions of Mixed Use
15.11.1 Permission or registration for mixed use can be cancelled or suspended by the concerned local body in case of violation of any of the conditions under which such mixed use is permissible / permitted.
15.11.2 The following non-residential activities, not covered under the mixed use policy, shall be permissible in residential areas under the following conditions:
¹ Modified vide S.O.3026 (E) dated 21-06-2018
² Modified vide S.O. 2273(E) dated 02-07-2019
³ Added vide S.O. 2034 (E) dated 12-08-2008
(i) All such non-conforming schools operating on private lands and existing on or before 01.07.06 shall be required to conform to the prevailing norms within three years. Such schools shall apply to the concerned local body to consider for regularisation by modification in the layout plan, failing which these shall be closed down / shift to conforming premises.
(ii) In addition, coaching centers and tuition centers referred to in para 15.7.1, running in residential premises, shall be allowed to continue till the end of May, 2008.
15.12Commercial Streets and Areas
15.12.1 The following streets / stretches of streets or areas may be notified as commercial streets or commercial areas by the local authority*:
a) Where more than 70% of the plots abutting roads of ROW of 24m or more, in a stretch of at least 300m, in regular plotted development are under commercial use, provided that no street in colonies in A and B categories shall be notified as commercial street.
b) Where more than 70% of the properties abutting roads of less width than 24m ROW, in a stretch of at least 100m, in rehabilitation colonies, regularized-unauthorized colonies, resettlement colonies, Walled City, Special Area and urban villages and local commercial streets / areas declared under MPD-1962 as per para 15.3.1; and
c) 1[In E, F and G category colonies, where, 80% of residential plots are under mixed use, or if there are 150 shops, within a contiguous area of 1 2{ha} the Local Body shall carry out a survey in such areas within a period of three months from the date of this Notification.]
d) Any street less than 6m ROW if declared as commercial streets shall be a pedestrian shopping street and not open to motorized transport.
* Provided that consistency shall be maintained by the local body in determining the ROW whether the street is bordered by service road, green verge, park or not.
1 Modified vide S.O.2034 (E) dated 12-08-2008
2 Modified vide S.O. 3173(E) dated 12-12-2014
15.12.2 For the notification of commercial streets / areas, in areas that have not been surveyed or have been surveyed but streets have not been notified pursuant to notification dated 7.9.2006, local bodies shall be required to carry out within a reasonable time of the notification coming into force, and with due expedition, and not later than 90 days, a survey of all streets of the above-mentioned width / areas, if not already done, with a view to identifying stretches of such streets / areas as commercial streets / areas.
1[Note 1 : The local body shall carry out a survey in those areas / streets / roads in urban villages and regularized-unauthorized colonies not surveyed pursuant to the provisions of MPD-2021 notified on 7.2.2007, within a period of three months of this notification.]
15.12.3 After identification is done, notification of commercial stretches / streets by the Urban Development Department, GNCTD would necessitate compliance to the following terms and conditions:
(i) Preparation of revised layout plan / Scheme for such areas / streets with the approval of the local body / Authority;
(ii) The lay-out plan / Scheme for such areas / streets should indicate adequate provision for circulation, parking, open spaces and other planning norms;
(iii) Common parking areas would be earmarked taking into account the additional load on traffic and parking consequent upon notification of the street as commercial area / street. If no parking space is available, land / plot on the said street / area may be made available by traders association, wherever possible, or acquired for construction of parking facilities, preferably, multi level parking. Development of such parking facilities may be done by either the traders association or by local bodies and may include publicprivate partnership as a model for implementation.
(iv) 2[On notification of a commercial street / area under this clause, such streets / areas shall be considered as local shopping centres as mentioned in Chapter 5 of this Plan. The plot owners / allottees on these commercial streets / areas shall have to pay conversion charges as prescribed by the Government from time to time, in respect of the built up area which shall not exceed the residential development control norms applicable to the plot. This is a onetime facility for plot allottees / owners in such commercial areas /
1 Added vide S.O.2034 (E) dated 12-08-2008
2 Modified vide S.O.2034 (E) dated 12-08-2008
streets and shall not be construed as relaxation of the development control norms in future.]
(v) Any other condition that may be prescribed by Government from time to time.
(vi) One time facility for all activities permitted in Local Shopping Centres shall be permissible in commercial streets and areas including multi-level parking. In addition, banquet halls shall also be permissible for which regulations may be prepared.
(vii) 1[Commercial activity in basement on such streets / areas (later designated as CC/LSC/CSC) shall be permitted, subject to relevant provisions of building bye-laws, structural safety and fire safety clearance etc. However, if such use of basement leads to exceeding the permissible FAR on the plot, such excess FAR shall be used subject to payment of appropriate charges as prescribed with the approval of Government.]
Annexure- 2 [15.0 (I)] List of PRE-1962 Built UP Residential and Rehabilitation Colonies
1.
Aliganj
30.
Nanakpura
2.
Andha Mughal
31.
Nicholson Marg
3.
Balbir Nagar
32.
New Rajinder Nagar
4.
Bharat Nagar
33.
Old Rajinder Nagar
5.
B. K. Dutt Colony
34.
Outram Lines
6.
Dishad Garden
35.
Patel Nagar (E)
7.
Gandhi Nagar
36.
Patel Nagar (W)
8.
Geeta Colony
37.
Patel Nagar (S)
9.
Gulabi Bagh
38.
Pratap Nagar
10.
Inderpuri
39.
Prem Nagar
11.
Jangpura - A
40.
Punjabi Bagh
12.
Jangpura - B
41.
Rajouri Garden
13.
Jangpura Extn.
42.
Rana Pratap Bagh
14.
Jawahar Nagar
43.
Ramesh Nagar
15.
Kalkaji
44.
Ram Nagar
16.
Kamla Nagar
45.
Rohtas nagar
17.
Karol Bagh
46.
Roop Nagar
18.
Kingsway Camp
47.
Sarai Rohilla
19.
Kirti Nagar
48.
Shahdara
20.
Kishan Ganj
16.0Land Use Plan
The Land Use Plan-2021 has been prepared based on
i) The policies enunciated for different urban activities,
ii) Requirement of additional social and physical infrastructure,
iii) Transportation and work centres,
iv) Already approved Zonal Development Plans and land use modifications.
In order to control the development, the areas have been designated as one of the 27 use zones identified in the Development Code. These use zones have been classified broadly in nine categories of land uses namely Residential, Commercial, Industrial, Recreational, Transportation, Utility, Government, Public & Semi - Public Facilities and Agriculture & Water Body. The development in these use zones would be carried out in accordance with the regulations as laid down in the Development Code and respective chapters.
16.1Zonal Development Plans
The NCTD has been divided in 15 Zones (Divisions) designated ′ A ′ to 'P' (except Zone 'I') in the Master Plan 2021. The Zonal Plans of eleven zones for the perspective year 2001 have been approved and notified whereas the Zonal Plans for the zones 'N (North West Delhi-III)', 'K' (part) between Dwarka & Rohini, 'J' (South Delhi- II), L (West Delhi -III), O (River Yamuna), P- II (North Delhi) are at various stages of preparation and process. The boundaries of the zones 'O', 'P' and 'N' as given in the MPD-2001 have been modified and accordingly the areas have been computed approximately as given in the Table 16.1
Table 16.1Zone wise Area
Zone
Name of Zone
Area (Ha.)
A B C D E F G H J K L M N *O P
Old City City Extn. (Karol Bagh) Civil Line New Delhi Trans Yamuna South Delhi-I West Delhi-I North West Delhi-I South Delhi-II K-I West Delhi-II K-II Dwarka West Delhi-III North West Delhi-II North West Delhi-III River Yamuna / River Front P-I Narela P-II North Delhi
* The above areas are approximate and the re-delineation and rezoning of the zones can be done with the approval of the Authority.
Mapping of the NCT of Delhi would be done using remote sensing and GIS tools and will also be updated from time to time to have valuable data as regards ground situation and also to have inputs to detect and prevent unauthorised development and encroachment on public land and to facilitate the protection of greens. The Zonal plans shall detail out the policies of the Master Plan 2021 and act as link between the Layout Plan and Master Plan. The development schemes and layout plans indicating various use premises shall conform to the Master Plan / Zonal Plans. The Zonal Plans of the areas shall be prepared under Section 8 and processed under Section 10 and simultaneously the modifications of land uses shall be processed under Section 11(A) of the Delhi Development Act, 1957. Already approved Sub Zonal (earlier Zonal) Plans in conformity with the Master Plan shall continue for the areas where the Zonal Plans have not been approved. The Zonal Plans in the form of structure plans shall be prepared within 12 months of the approval of the MPD-2021.
In absence of Zonal Plan of any area, the development shall be in accordance with the provisions of the Master Plan. No urban activity shall be permitted in the proposed Urban Extension without change of land use / modification to the Master Plan as per the Delhi Development Act, 1957.
16.2Special Area Regulations
The Walled City and its Extensions, Karol Bagh and the contiguous area in between has been designated as Special Area for the purpose of development since this area cannot be developed on the basis of normal regulations given in the development code. The Redevelopment Scheme for this Special Area should be prepared and notified by the ¹ [concerned municipal body] within three years. Special Area Building regulations shall be prepared by the Authority in consultation with the local body within a period of three years and notified with the approval of the Central Government.
The Authority may declare other historical / pre-1962 developed areas as Special Area. The development within these areas shall be governed as per the following norms and regulations (also refer 3.3.2 'Guidelines for Redevelopment Schemes' and 4.2.2. 'Restructuring and Upgradation of the existing areas):
Permission of use / use activities in use premises.
The noxious industries and hazardous trades shall be shifted from the Special Area within a maximum period of five years, and shall be replaced by other compatible uses.
The Public and Semi-public uses and services like Hospitals, ² [Tertiary Health Care Centre,] Dispensaries, Colleges, Schools, Police Stations, Fire Stations, Post Offices, Local Government Offices, Parking etc. shall be retained in their present locations and additional sites could be indicated in
¹ Modified vide S.O.3173(E) dated 12-12-2014
² Added vide S.O.2893(E) dated 23-09-2013
the Redevelopment Schemes / Zonal Plans. Any change or additions thereof shall be in accordance with the overall policy frame prescribed in the plan.
1[Special Area Building Regulations shall be framed for special area, unauthorized regularized colonies and village abadis. Owners in special area, unauthorised regularized colonies and village abadi shall register themselves with the Local Body within the next six months. They will also submit a certificate of structural safety by qualified engineers. Owners / occupiers of properties beyond 15 m height may bring the structure within prespcribed height by 30th June, 2009. Till such time, no punitive action would be taken against these structures beyond 15 m height. Subsequent to this date, subject to height restriction of 15 m, all buildings covered by such registration shall be exempted from punitive action till Special Area Building Regulations for these areas are notified or maximum three years, whichever is earlier.]
Regulations for special specific areas shall be as under:
i) Lajpat Rai Market: The single storeyed market on either side of Chandni chowk shall be retained.
ii) The isolated use premises like School adjoining Jama Masjid, Presentation Convent School and the Church at Kashmere Gate, Municipal Offices at Old Hindu College Building Complex shall be retained with existing building volume. Any additions or alterations shall be within the overall policy frame of conservation.
iii) Karol Bagh: Landuse and Development Code as per approved Zonal Development Plan and Local Area Plans.
iv) The redevelopment schemes for different use zones generally shall adopt regulations prescribed in the Development Code. However, the Authority may adopt suitable regulations in case where either it is not feasible or not advisable to adopt the general regulations prescribed.
Re-development Plan and Schemes for the Special Area should be prepared by the local body within three years of approval of the MPD 2021. In this Plan, the Metropolitan City Centres as referred in 5.3, Chapter 5.0 Trade and Commerce, shall be delineated based on survey. Till such time, status quo shall be maintained.
--- X --- X --- X --- X --- X ---
1 Modified vide S.O.2034(E) dated 12-08-2008
17.0 Development Code
Introduction
The purpose of the code is to promote quality of built environment by organising the most appropriate development of land in accordance with the development policies and land use proposals contained in the Plan.
It is a systematic code to ascertain the use activity (use) at two levels:
i. Conversion of Use Zone into Use Premises (layout); and
ii. Permission of Use Activities on Use Premises. The code differentiates between the Use Zone and Use Premises.
Enforcement of the Code
To regulate development in the National Capital Territory of Delhi within the framework of the land use plan, the following shall be observed:
Clause 1.0 Titles and Extent
1(1) This code may be called the Development Code.
1(2) It covers the National Capital Territory of Delhi.
Clause 2.0Definitions
In this code unless the context otherwise require:
2(1) Land use Plan means the plan indicating Use Zones as defined in Clause 4.0.
2(2) Zonal Development Plan means a plan for one of the zones (divisions) of the National Capital Territory of Delhi containing detailed information regarding provision of social infrastructure, parks and open spaces, circulation system, etc.
2(3) Local Area Plan means the plan of a Ward / Sub Zone to be prepared and approved by the concerned local body.
2(4) Layout Plan means a Plan indicating configuration and sizes of all Use Premises. Each Use Zone may have one or more than one Layout Plan depending upon the extensiveness of the area under the specific Use Zones and vice-versa. A layout plan shall have at least two use premises (apart from Recreational, utilities and transportation) and a minimum area of 1 Ha. below which it shall be termed as site plan or sub division plan.
Layout Plan will indicate the location of all proposed and existing roads with their widths, dimensions of plots along with building lines and setbacks, location of drains, public facilities and services and electric lines etc, statement indicating the total area of the site, area under roads, open spaces for parks, playground, recreational spaces and other public places, as required by specific sections of the development code.
2(5) Site Plan: A Detailed Plan showing the proposed placement of structures, parking areas, open space, landscaping, and other development features, on a parcel of land, as required by specific sections of the development code.
2(6) Use Zone means an area for any one of the Specified Use Category of the urban functions as provided for in Clause 4.0.
2(7) Use Premises means one of the many sub divisions of a Use Zone, designated in an approved layout plan, for a specific Use. Land use of a premise has to be determined on the basis of an approved layout plan.
2(8) Special Area means an area with special characteristics designated as such in the Plan for development / redevelopment.
2(9) Commercial Centres include a Metropolitan City Centre, District Centre, Community Centre, Local Shopping Centre, Convenience Shopping Centre and Non-Hierarchical Commercial Centres, Wholesale and Warehousing.
2(10) 1[Conversion charges / other levies as prescribed by the Government from time to time shall be payable wherever land use conversion is enabled at premise level by the Master Plan / Zonal Plan, Mixed Use Regulation and other Regulations.]
Clause 3.0Establishment of Use Zones and Use Premises
3(1) The National Capital Territory of Delhi is divided into 9 land use categories as mentioned in clause 4.0
3(2) Each land Use category is assigned number of use zones, which shall be further subdivided into required number of Use Premises with or without conditions in Layout Plans.
3(3) Each use premises shall be permitted to have specific uses / use activities out of the prescribed uses / use activities with or without conditions.
1 Modified vide S.O. 2034(E) dated 12-08-2008
3(4) The Layout Plans already approved by the Authority or any other local authority concerned in accordance with law shall be deemed to have been approved under this code.
3(5) An area in respect of which there is no approved Layout Plan shall be governed by the provisions of the Master Plan / Zonal Development Plan.
3(6) In case of Urban Design schemes, Redevelopment along MRTS Corridor, Urban Renewal schemes etc. on comprehensive basis the minimum area prescribed for planning and approval:
a) Scheme area for redevelopment 4 Ha.
b) Plot area for redevelopment 3000 sqm.
3(7) Accommodation Reservation (AR) and Transfer of Development Control Rights (TDR) are used as development control tools for implementing plans for redevelopment schemes in urban areas.
3(8) A landscape plan shall be prepared in case of the premises of size 3000 sqm. and above.
3(9) The natural drainage pattern shall not be disturbed.
3(10) Rainwater harvesting shall form an integral part of the storm water drainage plan, at the time of sanction of any layout plan.
Sanction of Plans
3(11) Layout Plans / Site Plans and Building plans shall be approved by the Local Bodies and Authority in their areas of jurisdiction.
3(12) Authority / Local Body(s) shall be empowered after levying penalty to compound deviations from limits of coverage/ FAR to the extent of 5% of the permissible coverage and FAR, subject to maximum of 13.5 sqm. in building(s) / premises at the time of considering the completion / occupancy certificate. In Group Housing schemes and Public & semi-public facilities, 5% FAR beyond permissible FAR can be compounded by the authority / Local Body at the time of considering the completion/occupancy certificate.
3(13) Wherever required, the Technical Committee of the DDA shall formulate policy guidelines for the sanctioning of local area plans, layout plans, comprehensive schemes, re-development schemes, urban renewal schemes and multi-storeyed buildings in all land use categories. The Technical Committee shall be empowered to call for the plans from the development organisations / Local Bodies and would give directions / recommendations wherever necessary.
Clause 4.0Use Zones Designated
There shall be 9 Land Use categories subdivided into use Zones as given below:
Residential
RD Residential area
RF Foreign Mission
Commercial
C1 Retail Shopping, General Business and Commerce, District Centre,
C2 Wholesale, Warehousing, Cold Storage and Oil Depot
C3 Hotels
Industrial
M1 Manufacturing, Service and Repair Industry.
Recreational
P1 Regional Park
P2 City Park, District Park, Community Park.
P3 Historical Monuments
Transportation
T1 Airport
T2 Terminal / Depot - Rail / MRTS / Bus / Truck
T3 Circulation - Rail / MRTS / Road
Utility
U1 Water (Treatment Plant etc.),
U2 Sewerage (Treatment Plant etc.),
U3 Electricity (Power House, Sub-Station etc.)
U4 Solid Waste (Sanitary landfill etc.)
U5 Drain
Government
G1 President Estate and Parliament House
G2 Government Office / Courts
G3 Government Land (use undetermined)
Public and Semipublic Facilites
275
PS1 Hospital, 1[Tertiary Health Care Centre,] Education and Research University / University centre, College, Social - Cultural, Socio Cultural Complex/ Centre, Police / Police Headquarter / Police
PS3 Sports Facilities / Complex / Stadium / Sports Centre.
GREEN BELT / AND WATER BODY
A1 Plant Nursery
A2 Green Belt / Agricultural Green
A3 River and Water body
1[...]
Mixed Use Zone
A use zone in the Land Use Plan could be indicated as consisting of more than one use zones.
Clause 5.0 Use Premises Designated
The use premises and Uses / Use Activities with similar nomenclature are given with the controls of specific premises in the respective chapters.
Clause 6.0 Location and Boundaries for Use Zones
6(1) Any one of the use zones may be located at one or more than one places as shown in the Land Use Plan.
6(2) The boundaries of various pockets of use zones are defined in land Use Plan by features like roads, railway tracks, drains etc.
Clause 7.0 Location and Boundaries of Use Premises
7(1) The location and boundaries of each use premises shall conform to as specified in the layout plan with reference to important bench mark like road, drain or other physical features.
7(2) Any change in the location, boundaries and predominant use of use premises due to any reason whatsoever and duly approved shall be incorporated in layout plan.
Clause 8.0Sub Division of Use Zones, Permission of Use Premises in Use Zones and Control of Buildings
8(1) SUB-DIVISON OF USE ZONES INTO USE PREMISES
1 Deleted vide S.O. 4614 (E) dated 24-12-2019.
The objective of these regulations is to guide the preparation of layout plans for residential and industrial use zones. These regulations include norms for provision of facilities and circulation system. The service plans corresponding to these layout plans for provision of physical infrastructure like water supply, sewerage, drainage, etc., shall conform to municipal byelaws.
The use zone other than residential and industrial shall have integrated plans governed by respective building control regulations.
Integrated plan differs from customary layout plan as in the former the regulations are for the total plot and sub-divisions are done for the development purpose. The norms for sub-division of residential and manufacturing use zone into use premises are given in respective chapters.
Sub / Clause 8(2) Permission of Use Premises in Use Zones
(As part of approval of layout plan or as a case of special permission from the Authority)
Permission of selected Use Premises in Use Zones RD, C1, C2, M, PS
Sl.No.
Use Premises
Use Zones
RD
C₁
C₂
M
PS
RD
RESIDENTIAL
i
Residential plot - Plotted Housing
P
P**
NP
NP
NP
¹ [ii
Residential plot - Group Housing
P
P
NP
P
P]
² [iii
Studio Apartment
P
NP
NP
NP
NP]
iv
Residence - cum - Work Plot
P
P
NP
NP
NP
v
Foreign mission
P
P
NP
NP
NP
vi
Hostel / Old age home
P
P
NP
P
P
³ [vii
Short term Accommodation - Hostel / Guest house / Lodging & Boarding House / Sarai / Working Women-Men Hostel, Dharamshala and its equivalent / Service Apartment
P
P
P
P
P]
viii
⁴ [Multipurpose Community Hall / Barat Ghar
P
P
NP
P
P
ix
Night Shelter
P
P
P
P
P
x
Community / Recreational Hall, Library, Reading Room, Society Office, Crèche and Day Care Centre.
P
P
P
P
P
xi
³ [State Bhawan/ State Guest Houses
P
P
P
P
P]
xii
⁵ [Affordable Rental Housing Complex (ARHC)
P
P
P
P
P]
¹ Modified vide S.O. 1215(E) dated 13-05-2013
² Added vide S.O. 2895(E) dated 23-09-2013
³ Modified vide S.O. 2895(E) dated 23-09-2013
⁴ & ³ Modified vide S.O. 3348(E) dated 17-10-2017
⁵ Added vide S.O. 3601(E) dated 01.08.2022
C
COMMERCIAL
i
Local Level (Convenience / Local shopping centre)
P
P
P
P
P
ii
Cinema / Multiplexes
NP
P
P
P*
NP
iii
Service markets / Informal Bazaars
P
P
P
P
NP
iv
Wholesale Trade
NP
P
P
NP
NP
v
Storage, godown and warehousing, cold storage & Ice factory, gas godown.
NP
NP
P
P
NP
R
RECREATIONAL
Recreational (Park, Play grounds, Swimming Pool) / Sports Complex/ Stadium/ Amusement parks/ Recreational Clubs etc.
P
P
P
P
P
M
INDUSTRY
i
Industrial plot, flatted group industry
NP
NP
NP
P
NP
ii
Service centre & Service industry
NP
P
P
P
NP
T
TRANSPORTATION
Circulation (Road network with street furniture, Bus terminal, MRTS stations, Parking etc.
P
P
P
P
P
Bus depot & Workshop
NP
NP
NP
P
NP
G
GOVERNMENT
i
Local / Government maintenance Offices
P
P
P
P
P
ii
Offices of utility services providing agencies
P
P
P
P
P
1[iii
Government Offices (Central / State Government / Local Bodies)
NP
P
P
P
P
iv
District Court/ Family Courts
NP
P
P
P
P]
PS
PUBLIC AND SEMI PUBLIC FACILITIES
2[i
1 Modified vide S.O. 3348(E) dated 17-10-2017
2 Modified vide S.O. 2893(E) dated 23-09-2013
3 Added vide S.O. 2895(E) dated 23-09-2013
ix
Institute/ Management institute/Teacher Training Institute, etc.)Facilities - Bus terminal, taxi stand,milk / vegetable booths, religiouspremises, vending booth, petrol / CNGfilling pump, recreational club,¹[police outpost, police post, policestation, fire post,] fire station, postoffice, & telegraph office andtelephone exchange.
P
P
P
P
P
P: Permitted P*: Permitted only in Commercial Centres
NP: Not Permitted P**: Special permission as per Mixed use/ Special Area Regulations
i) Park, Open Parking, Circulation and Public Utilities are permitted in all use zones.
ii) Limited remunerative uses may be permitted for making environmental upgradation of social upliftment projects such as covering of drains, in-situ rehabilitation schemes etc. financially viable. The activities and extent of the use permitted to be decided by DDA.
iii) Property development in area around Metro Stations(composite) upto a maximum area of 3.0 Ha., shall be permitted in all use zones, except Recreational and Ridge / regional park use zone subject to approval of the Technical Committee of DDA.
iv) The permission of use premise in the following use zones shall be governed by the specific function of the use zone.
C3- Hotel, P3- Historical Monuments, T1- Airport, T2- Terminal / Depot - Rail / MRTS / Bus / Truck, T3- Circulation - Rail / MRTS / Road, U1-Water, U2-Sewerage, U3-Electricity, U4-Solid Waste, U5-Drain, G1-President Estate & Parliament House, G3-Government Land (Use Undetermined), PS1 -Cremation and Burial Ground, Religious, A2-Green Belt and A3-River & Water Body.
²[v] Land use of Village Abadi (Lal Dora / firni) ³{and Extended Lal Dora} located in any use zone is residential.]
¹ [vi] Motels with approved plans as on 07/02/2007 or whose proposal of Motel has been acceded to ² (including all such proposal of motels
¹ Added vide S.O. 2790(E) dated 24-08-2016
² Modified vide S.O. 2034(E) dated 12-08-2008
³ Added vide S.O. 2890(E) dated 23-09-2013
which were in process of examination or matter challenged in the court of law or having approval in files from DDA or 3[concerned municipal body] or not acceded to due to enforcement of MPD-2021 on 07.02.2007 are also eligible for sanction} and located in Commercial Areas or Proposed Facility Corridor in Zonal Development Plans and Other Use Zones (which have been established under MoUD Notification dated 16-06-1995 of the notified Zonal Development Plans under MPD-2021 which were having Rural Use Zone / Green Belt prior to 07-02-2007) shall be permissible subject to Development Control conditions mentioned in Table 5.4.]
4[vii) New Temporary cinemas shall not be permissible, however already existing Temporary Cinemas shall be allowed to continue on permanent basis as per the conditions given below:
a) Seat Capacity
- Minimum 300 seats in one or more cinema halls
b) Minimum road R/W in - 18 mt. front
c) Parking Requirement
d) Maximum Ground Coverage
e) FAR
f) Plot size
- 3 ECS per 100 sqmt of Built up space (with in Plot Area)
- 50% (subject to minimum setbacks as per MPD - 2021 to be adhered)
- 100 subject to a maximum built up area of 3000 sqmt.
In case, the plot size is more than 4000 sqmt. And is located on 24 mt. ROW, maximum FAR allowed not to exceed 4000 sqmt. Subject to undertaking traffic impact study, availability of the road width and the surrounding development so that it may not cause traffic congestion in the area.
- Min. 1200 sqmt & max. 4000 sqmt. In case a cinema hall has more land, the rest of the area would be kept Green.
g) Max. Permissible Height - 15mts.
¹ Added vide S.O. 2555 (E) dated 26-10-2012
³ Modified vide S.O. 3173(E) dated 12-12-2014
² Modified vide S.O. 2759(E) dated 13-09-2013 and S.O. 2799(E) dated 16-09-2013
⁴ Added vide S.O. 1487(E) dated 07-06-2013
h) Commercial activity shall be permissible after excluding the space required for capacity of 300 seated cinema hall. The commercial space will be for the activities as permissible for Local Shopping Centre (LSC) in MPD – 2021.
i) Cinema would confirm to the Cinematography act and other statutory provisions. Multiplexes shall accordingly be permissible.
j) Landuse conversion charges, FAR charges, betterment levis and other charges will be levied as approved by the Government from time to time.
k) The local body and Licensing Authorities shall ensure that the above conditions are compiled before renewing the license.
l) The Temporary Cinema existing on Government Land shall not continue.
m) The excess land in such cases if required for larger public purposes shall be acquired and developed as per the local area need/Master Plan provisions by the concerned local agencies. Individual cases will be processed as per the above provisions after the enabling provisions are made in the MPD- 2021 for Change of Landuse.
It should be ensured that adequate parking facilities are provided within the respective plot areas.]
1[viii) Size of hospital plot will be restricted upto 1.5 ha. in residential area, with preference to plot having three side open and having minimum 18m ROW on one side. Total floor area of the hospital shall be governed as per the total number of beds allowed in it.
ix) The bed count of a Health Facility may be allowed as per permissible FAR, needs of the community and demand studies.]
²[x] Extension of Lal Dora/firni, located in any use-zone, be considered as residential as per the notification by Revenue Deptt., GNCTD.
xi) In Village Abadi (Lal Dora/firni) and Extended Lal Dora, the facilities recommended for neighbourhood population of 10,000 (as per Table 4.2) to be permitted on plots facing a minimum road of 9 m.]
3[xii) Use premise which are to be provided/permitted while preparing plans for Residential Use Zone at community level given in para 4.4.2 A and B, shall be permitted in other use zones as above. These Use Premises are also permitted while preparing layout plans for
¹ Added vide S.O. 2893(E) dated 23-09-2013
² Added vide S.O. 2894(E) dated 23-09-2013
³ Added vide S.O. 2895(E) dated 23-09-2013
respective Use Zone with the approval of concerned local body and approval of the Authority is not required.]
8(3) Regulations for Building Controls Within Use Premises
The objective of these regulations is to provide controls for building(s) within use premises excluding the internal arrangement, which are covered in Building Bye-laws.
General Notes:
Where development controls are not stipulated for any use premise, the same can be formulated by the Authority.
The mezzanine floor and service floor wherever provided shall be considered as a part of the total FAR. ¹ [In case of the buildings with 26 m. and more height in all use-zones, Technical Committee of DDA may permit the following in special circumstances:
a) In case of provision of stack-parking in stilt floor or basement, minimum height should be 2.5 m.
b) Intermittent service floor may be permitted for installation of equipments and services required for the maintenance of the building with prior approval of the agencies concerned and are not to be counted in FAR. The height of the service floor is to be decided based on the depth of structural members, the height requirement for providing water-reservoirs, other equipments, etc. The height of Service floor in the building shall be limited to 1.8 m.]
If the building is constructed with stilt area of non-habitable height (2.4 mts) and is proposed to be used for parking, landscaping, etc. the stilt floor need not be included in FAR.
Wherever the building regulations are given for different categories of plots, the area covered and the floor area shall in no case be less than the permissible covered area and floor area respectively for the largest size of plot in the lower category.
² [In case of all the plots of size 1000 sq.m. and above, except 'Residential Plot - Plotted Housing', atrium will be permitted with stipulations - Maximum 10% additional ground coverage shall be allowed for providing atrium. In case, the permissible additional
¹ Added vide S.O. 2895(E) dated 23-09-2013
² Added vide S.O. 678(E) dated 04-03-2014
ground coverage for atrium is utilized, 25% of the utilized ground coverage shall be counted towards FAR.]
Table 17.1Minimum Setbacks (Other than Residential Plotted Development)
Front* (m) (for all edges facing a public ROW of 18 m+)
Rear (m)
Side (m)(1)
Side (m)(2)
Setback to be handed back to local body as public roads (at least 20% of plot/scheme area)
8
Above 3,000 upto10,000
0
6
6
6
9
Above 10,000
0
12
12
12]
i. In case the permissible coverage is not achieved with the above given setbacks, the setbacks of the preceding category may be 2[allowed]. 3[…]
ii. The setbacks are subject to requirements of height and ventilation as per building byelaws. 3[…]
1 Added vide S.O. 1914 (E) dated 14-07-2015
2 Modified vide S.O. 1914 (E) dated 14-07-2015
3 Deleted vide S.O. 4614 (E) dated 24-12-2019.
iii. In case a layout is sanctioned with more than the minimum prescribed setbacks, the same shall be followed in the sanction of the building plans.
iv. The Technical Committee of DDA may relax setbacks, ground coverage and height in special circumstances.
v. ESS wherever required to be provided within the plot, is allowed by shifting of side / rear setbacks. 1[...]
8(4) Parking Standards
Parking Standards have been prescribed in each use premises however, where it is not prescribed, it will be followed as given in the Table 17.2.
Table 17.2Parking Standards
Sl. No.
Use Premises
Permissible Equivalent Car Spaces (ECS) per 100 sqm. of floor area1[*]
1.2.3.4.5.1[…]
Residential Commercial Manufacturing Government Public and Semi Public-Facilities
2.03.0 <sup>2</sup>[**]2.01.82.0
2[Notes:
* Additional parking may be created within integrated schemes only as paid, shared parking facilities accessible to general public at all times.
** Planned commercial centres may be developed / redeveloped as per integrated schemes, in which mixed use component may be introduced along with comprehensive PMD plans, feeder systems, public spaces, etc. In such cases, parking norms may be rationalized and ECS norms for mixed use may be applied subject to approval of Technical Committee of DDA. Activities permitted shall be as per Table 5.1 of the Master Plan.]
i) In existing buildings having plot area of more than 2000 sqm., an extra ground coverage of 5% shall be permissible for construction of automated multi-level parking to provide dedicated parking structures for additional needs.
ii) For the provision of car parking spaces, the space standards shall be as given in Table 17.3.
Table 17.3Space Standards for Car Parking
Sl. No.
Type of Parking
Area in sqm. per ECS
1.
Open
23
2.
Ground floor covered
28
1 Deleted vide S.O. 4614 (E) dated 24-12-2019
2 Added vide S.O. 1914 (E) dated 14-07-2015
3.
Basement
32
4.
Multi level with ramps
30
5.
Automated multilevel with lifts
16
iii) In the use premises, parking on the above standards shall be provided within the plot.
iv) 1[In cases, where the building (except hotel) with sanctioned plan is existing/ under construction and where building plans stand sanctioned as per MPD-2001, the parking is to be provided for additional FAR availed, shall be as per the parking standards prescribed in MPD-2021.]
2[v] Parking is one of the utilities permitted in all use zones except in regional park / ridge, Recreational Open Space and parks as per the approved Zonal Plan/ layout plan.
vi) The standards given in Equivalent Car Space (ECS) shall include parking for all types of vehicles i.e. cars, scooters, cycles, light and heavy commercial vehicles, buses etc. Parking adequacy statement / study for large projects like Stadia, Shopping Malls, Multiplexes will be desirable. Mode-wise parking spaces are to be marked on drawings to be submitted for approval.]
²[Table 17.4: Indicative On-site Parking (ECS) Requirements for projects*
Mode
ECS Standard by mode
Area in Sq.m. (including circulation)
Distribution by mode - per 1 ECS / 100 sq.m. of Built Up Area for all projects
Distribution by mode per 1 ECS / 100 sq.m. of Built Up Area within TOD Zone.
Cars/ Taxis
1
23.00
0.60
0.60
2 Wheelers
0.25
5.75
0.25
0.10
Cycles
0.1
2.30
0.05
0.10
Buses/ Shared Vans
3.5
80.50
0.05
0.10
Commercial vehicles
3.5
80.50
0.05
0.10
Total
1.00 ECS
1.00 ECS
* The above figures are indicative and may be customized on case to case basis. However minimum proportion of cycle parking is mandatory.]
8(5) Basements
¹ Added vide S.O. 1603(E) dated 17-07-2012 and S.O. 1706(E) dated 26-07-2012
² Added vide S.O. 1914 (E) dated 14-07-2015
a) Basement(s) upto the setback line maximum equivalent to parking and services requirement, such as Air Conditioning Plant and equipment, water storage, Boiler, Electric Sub-Station HT and LT Panel rooms, Transformer Compartment, Control Room, Pump House, Generator Room and other mechanical services and installation of electrical and fire fighting equipments, and other services required for the maintenance of the building with prior approval of the concerned agencies, could be permitted and not to be counted in FAR. 1[In case of Hotels Laundry, Cold Room for storing Food articles, Linen store, Garbage room, Housekeeping store and cold storage may be allowed.]
b) ²[The basement(s) beyond building line shall be kept flushed with the ground and shall be ventilated with mechanical means of ventilation; and]
c) Basement(s) shall be designed to take full load of the fire tender, wherever required and subject to adequate safety measures.
d) In case the basement is used for activity in conformity with the use premises, wherever permitted, the same shall be counted in FAR subject to clearance from the Fire Authorities and other statutory bodies.
e) Parking area, if misused, is liable to be municipalized / taken over by the Local Body / Authority.
f) The ESS, fire fighting installations and underground water tank shall neither be counted in ground coverage nor in FAR.
$^{3}$ [8(6) Services Plan
The Developing Agency should provide for the following in layout plans of plots of size 3000 sq.m and above:
i) Recycling of treated waste water with separate lines for potable water and recycled water. Dual piping system to be introduced.
ii) Ground water recharge through rain water harvesting, conserving water bodies and regulating groundwater abstraction.
iii) Treated sewage effluent should be recycled for non-potable uses like gardening, washing of vehicles, cooling towers, etc.
¹ Modified vide S.O. 678(E) dated 04-03-2014
² Modified vide S.O. 1215(E) dated 13-05-2013
³ Added vide S.O. 2894(E) dated 23-09-2013
iv) Utilities such as, underground water storage tank, roof-top water harvesting system, separate dry and wet dustbins etc. are to be provided within the plot.
v) All hospitals, commercial, industrial, hotels, restaurants, auto workshops, etc. will have to make arrangements for primary effluent treatment within the plot.
vi) Provide ESS and generator and to submit energy consumption/audit will be submitted at the time of sanction of building plans.
vii) Provision of cavity walls, atriums, shading devices in buildings will be encouraged to make them energy efficient.
viii) Solar heating system will be provided on all plots with roof area of 300 sqm and above.
ix) In order to encourage the above, 1% to 4% extra ground coverage and FAR, on each, may be given as an incentive by the local bodies, depending upon the provisions made. In exceptional cases 5% incentive may be permitted.
x) These incentives shall be based on the rating criteria prescribed by ‘Green Rating for Integrated Habitat Assessment’ (GRIHA) for green buildings.
xi) In case of non-compliance of above, after obtaining occupancy certificate, penalty at market rate shall be levied for incentive FAR by land owning agency.
The regulations for enforcement of above shall be prepared by the Director, Local Self Government, GNCTD in consultation with Environment Department, GNCTD within a period of six months (after notification of modifications) and notified with the approval of the Authority/Central Government
8 (6).1 Neighbourhood Level
i) The listed water bodies and/or any water body above 1 ha. size are mandatory to be systematically included in the landscape plan.
ii) Decentralised STPs with smaller capacities are to be provided at the community level. Possibility of generating energy/gas as fuel from sewage shall be explored.
iii) Municipal Waste of biodegradable and recyclable waste is to be segregated at source; decentralized treatment at neighbourhood level may be adopted; whereas for non-biodegradable waste centralized treatment may be followed.]
The main building facade should face the street, located on the property line without setback or with active use within set back and transparent edge that contribute to street safety. Commercial frontages should have facades with minimum 50% transparency (untinted) to facilitate visual surveillance of streets.
In case enclosure of sites is required, transparent fencing should be used above 300 mm height from ground level.
Vending spaces should be marked in addition and adjacent to the walking path, especially along high pedestrian volume areas to activate the street and make it safe. Space to be planned for utilities including drinking water kiosks and toilets so that the walking space is enhanced but not compromised.
3I. Provide adequate low-mast Street Lighting for pedestrians and bicycles, in addition to any high-mast lighting provided for the carriageway. Approx. 20 lux level is suitable for non-shopping areas and footpaths and 25-30 lux-level is
required for shopping areas, bus-stops, Metro station exits and any areas where pedestrians are expected to gather or wait.
3J. Provide Dustbins, post-boxes, signage and other public amenities at street corners for high usability.
Sl.No.
Category
Maximum
Other Controls
Ground Coverage
FAR
Height
4
University Campus including International Education Centre (IEC) - Large campus (10 ha and above) will be divided into following four parts:a) Academic including Administration (45% of total land area)
30%
1[225]
37 m
1. Parking standard @ 1.33 ECS / 100 sq m of floor area.2. Other controls related to basements etc. are given in the Development Code chapter.3. Landscape plan to be prepared.
b) Residential (25% of total land area)
1. Regulations for group housing shall apply.2. The land shall be reserved for facilities as per residential norms.
c) Sports and Cultural activities (15%)
10%
15
26 m
d) Parks and Landscape (15%)
N. A.
2[5
Collegei. In case of old colleges plot will be divided as follows:Area per college : 4.0 ha
1. Development control norms for academic college building area & residential will be same as S. No. 4 above]
a. College Building area
1.8ha
45%
b. Play field area
1.8ha
45%
c. Residential including hostel area
0.4ha
10%
ii. In case of variation in area the % to be followed.
1 Modified vide S.O. 2895(E) dated 23-09-2013
2 Added vide S.O. 1215(E) dated 13-05-2013
8
Police camp including Central Police Organization /Security Forces*
12.5%
25
9 m.
9
Traffic and police control room
1. As per requirement on major road junctions / stretches etc. as part of road right of way based on site feasibility.2. Maximum area = 25 sq m.
*Including Central Security Forces
Notes:
** 60% of the plot land shall be utilized for the Police Station with 200 FAR and 40% of the plot land shall be utilized for Police Personnel Housing with 400 FAR. Whereas other Development Control Norms i.e., ground coverage, set-back and parking requirement, etc. shall be as prescribed in Table 13.11 and para 4.4.3.B Residential Plot-Group Housing, respectively. Existing police station sites shall also be eligible for afore-said provision.]
¹ Deleted vide S.O. 2790(E) dated 24-08-2016
ii. Standard type designs and layout should be prepared by the local bodies and made available to the people so that crucial time is not lost in approval of layout plans and building plans after disaster.
Disaster Management Centres have been proposed to serve people in the case of disaster and provide emergency shelters.
1 Added vide S.O. 2893(E) dated 23-09-2013
A premise having facility of Print, Television & Internet, News gathering and News Dissemination with or without training/ education of all arms of media.
Facilities for Media (print, television & internet), news gathering and news dissemination, training, auditorium, library, press club, dining area, snacks stall and hostel accommodation for students and residential accommodation for essential staff.
10.
Museum, exhibition centre and art gallery, auditorium and
Combination of Museum, exhibition centre and art gallery, auditorium and open air theatre.
Museum, Exhibition Centre and Art Gallery Auditorium and Open Air theatre, Watch & Ward Residence (upto 20
open air theatre
sqm.)
11.
Cultural and Information Centre
A premise with facility for cultural and information services for an institution, state, and country.
Cultural and Information Centre, Watch & Ward Residence (up to 20 sqm.) Hostel, Canteen, Bank Extension Counter Facility, Auditorium (Up to 500 seating capacity) Library, Exhibition and Art Gallery.
12.
Social and Cultural Institute
A premise with facilities for activities of socio-cultural nature run by a public, voluntary or individual on primarily non commercial basis.
Social and Cultural Institute, Watch & Ward Residence (upto 20 sqm.) Soft Drink & Snack Stall, Restaurant, Canteen, Bank Extension Counter Facility Auditorium, Library, Music, Dance, and Drama Training Centre, Museum, Exhibition Centre and Art Gallery.
13.
International Convention Centre
A premise having all facilities for international / national conferences, meetings, symposium, etc.
International Convention Centre, <sup>1</sup>[ Exhibition space, Convention and meeting space, office space/ commercial office, retail trade, Hotels with permissibility of activities as per Table 13.17 and Table 5.5.]
14.
Planetarium
A premise having the facility of watching and observing the sky and universe and information dissemination.
Planetarium, watch & ward residence (upto 20 sqm.), cafeteria.
15.
Rain Basera (Night Shelter)
A premise having the facility for providing the night accommodation to individuals without any charges or with token charges. It may run by local government or voluntary agencies.
Night Shelter and related facilities.
16.
Anganwari
Anganwari as a space provision at residential housing / neighbourhood level is a centre to provide service for children of 0 to 6 years age, pregnant women, feeding mothers, etc. under the Integrated Child Development Scheme (ICDS).
Kitchen, Toilet & Hall.
Replacement of low efficiency incandescent lamp with high efficiency fluorescent tubes (CFLs) without compromising with the lumens output.
b) Similarly for refrigerators, which account for 30% of total electricity consumed, measures like increased thickness of foam insulation, use of high coefficient compressors increased evaporator surfaces, use of tighter door seals and through technical improvements can reduce
consumption from 540 KWH/year to 300 KWH/year (for a 165 litre refrigerator).
c) Incandescent bulbs, neon tubes and fluorescent lamps are giving way to light-emitting microchips that work longer, use less power and allow the use of light in new ways. The chips, known as light emitting diodes, or LEDs have huge performance advantages in many mundane tasks (such as traffic lights). These consume 80 per cent less electricity than the bulbs and have longer life. Moreover, they have the safety advantage of gradually fading instead of burning out. This eventually results in huge savings in terms of energy and maintenance costs.
additional requirement of civic amenities and the provision for traffic circulation and parking.
vi) The notification shall be issued by the Urban Development Department, GNCTD immediately after the field survey is completed.
49.
Shakti Nagar
¹ Modified vide S.O.3026 (E) dated 21-06-2018
² Modified vide S.O. 3173(E) dated 12-12-2014
Kishan Nagar
Sheikh Sarai
Lajpat Nagar - I to IV
Shivaji Park
Malka Ganj
Subhash Nagar
Malviya Nagar
Tilak Nagar
Mansarovar Garden
Timar Pur
Model Basti
Tihar - I & II
Model Town
Vinoba Puri
Moti Nagar
Vijay Nagar
Multan Nagar
--- x---x---x---x---x---
Hospital (0.2 ha. to 1.5 ha.)
P
P
NP
P
P
ii
Tertiary Health Care Centre
P
P
NP
P
P]
ii
Primary Health Centre / Family Welfare Centre / Maternity Home / dispensary etc.
P
P
NP
P
P
iii
Nursing Home / poly clinic / clinic / clinical laboratory etc.
P
P
NP
P*
P
iv
Dispensary for pet and animals
P
P
P
P
P
v
Primary school / Middle school
P
NP
NP
NP
P
vi
Sr. Secondary School
P
NP
NP
NP
P
vii
School for Mentally Challenged 3[/ differently abled persons]
P
NP
NP
NP
P
viii
Technical Training centre (ITI / Polytechnic/ Vocational/ Training