12.1 The Envelope Performance Factor
12.1.1 The envelope performance factor shall be calculated using the following equations.
Equation 12 1:
where
E P F T o t a l = E P F R o o f + E P F w a l l + E P F F e n e s t
Where
EPF Roof : Envelope performance factor for roofs. Other subscripts include walls and fenestration.
As, Aw : The area of a specific envelope component referenced by the subscript a S or for windows the subscript “w”.
SHGCw : The solar heat gain coefficient for windows (w). SHGCs refers to skylights.
Mw : A multiplier for the window SHGC that depends on the projection factor of an overhang or sidefin.
Us : The U-factor for the envelope component referenced by the subscript " S "
CRoof : A coefficient for the “Roof ” class of construction
Cwall : A coefficient for the “Wall”
Appendix D: Building Envelope Tradeoff Method
C1 Fenest : A coefficient for the “Fenestration 1
C2 Fenest : A coefficient for the “Fenestration 2
Values of " C " are taken from Table 12.1 through Table 12.5 for each class of construction.
| Daytime Occupancy | 24-Hour Occupancy | |||
| U-factor | SHGC | U-Factor | SHGC | |
| Mass Walls | 6.01 | - | 13.85 | - |
| Curtain Walls, Other | 15.72 | - | 20.48 | - |
| Roofs | 11.93 | - | 24.67 | - |
| North Windows | -1.75 | 40.65 | -4.56 | 58.15 |
| Non-North Windows | -1.25 | 54.51 | 0.68 | 86.57 |
| Skylights | -96.35 | 311.71 | -294.66 | 918.77 |
12.1.2 Overhang and Side Fin Coefficients
The " M " multiplication factor can also be calculated using Equation 12 2. If the equation is used, a separate calculation shall be made for each orientation and unique shading condition.
Equation 12 2: M = a · PF² + b · PF + 1
| Device | Coefficient | North | South | East/West |
| Overhangs | A | 0.16 | 0.21 | 0.10 |