Sanitation requirements for Shops and Commercial Offices
| Sr. No. | Sanitary Unit / Fittings | For Personnel |
|---|---|---|
| 1 | Water closet | One for every 25 persons or part thereof exceeding 15 (including employees and customers). For female personnel 1 for every 15 persons or part thereof exceeding 10. |
| 2 | Drinking Water Fountain | One for every 100 person with a minimum of one on each floor. |
| 3 | Wash Basin | One for every 25 persons or part thereof. |
| 4 | Urinals | Nil upto 6 persons 1 for 7-20 persons 2 for 21-45 persons 3 for 46-70 persons 4 for 71-100 persons From 101 to 200 add @ 3%; For over 200 persons add @ 2.5%. |
| 5 | Cleaners' Sink | One per floor minimum, preferably in or adjacent to sanitary rooms. |
Note: Number of customers for the purpose of the above calculation shall be the average number of persons in the premises for a time interval of one hour during the peak period. For male-female calculation a ratio of 1: 1 may be assumed.
Page | 112
Sanitary Requirements for Hotels
| Sr. No. | Sanitary Unit | For Residential Public staff | For non residential Staff | |
| For male | For female | |||
| 1 | Water Closet (W.C.) | One per 8 Persons omitting occupants of the attached water closet minimum of 2 if both sexes are lodged | 1 for 1-15 persons 2 for 16-35 persons 3 for 36-65 persons 4 for 66-100 person | 2 for 1-12 persons 4 for 13-25 persons 6 for 26-40 persons 8 for 41-57 persons 10for 58-77 persons12for78-100persons Add 1 for every 6 persons or part thereof. |
| 2 | Ablution Taps | One in each W.C. | One in each W.C. | One in each W.C. |
| 3 | Urinals | Nil | Nil upto 6 persons 1 for 7-20 persons 2 for 21-45 persons 3 for 40-70 persons 4 for 71-100 persons | Nil |
| 4 | Wash Basins | One per 10 persons omitting each basin installed in the room / suite | 1 for 15 persons 2 for 16-35 persons 3 for 36-65 persons 4 for 66-100 persons | 1 for 1-12 2 for 13-25 3 for 26-40 4 for 41-57 |
| 5 | Baths | One per 10 persons, less occupants of room with bath in suite | Nil | Nil |
| 6 | Cleaner's Sinks | One per 30 Bed rooms (one per floor minimum) | Nil | Nil |
| 7 | Kitchen Sink | One in each Kitchen | One in each Kitchen | One in each Kitchen |
Page | 113
Contd: For Public Rooms
| Sr. No. | Sanitary Unit | For Male | For Female |
| 1 | Water Closet | One per 100 persons upto 400 persons; for over 400 add at the rate of one per 250 persons or part thereof. | Two for 100 persons upto 200 persons; over 200 add at the rate of one per 100 persons or part thereof. |
| 2 | Ablution Taps | One in each W.C. | One in each W.C. |
| 3 | Urinals | One for 50 persons or part thereof. | il, upto 6 persons 1 for 7-20 persons 2 for 21-45 persons 3 for 46-70 persons 4 for 71-100 persons |
| 4 | Washbasins | One per WC/Urinal | One per WC |
| 5 | Kitchen Sink | One in each Kitchen | One in each Kitchen |
| 6 | Baths (showers) | One per 10 persons | |
| 7 | Cleaner's Sinks | One per 30 Bed rooms (one per floor minimum) | |
i) It may be assumed that the two-thirds of the number are males and one- third females.
Note:
ii) One water tap with drainage arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closet and urinals.
Sanitation Requirements for Educational Occupancy
| Sr. No. | Sanitary Unit | Boarding Institution Other | Educational Institution | ||
| For Boys | For Girls | For Boys | For Girls | ||
| 1 | Water Closet | One for 8 boys or part thereof | One for 6 girls or part thereof | ne for 40 boys or part thereof | One for 25 girls or part thereof |
| 2 | Ablution Taps | One in each W.C. | One in each W.C. | One in each W.C. | One in each W.C. |
| 3 | Urinals | One per every 25 pupils or part thereof | _____ | One per every 20 pupils or part thereof | _____ |
| 4 | Wash basins | One for every 8 pupils or part thereof | One for every 6 pupils or part thereof | One for every 60 pupils or part thereof | One for every40pupils or part thereof |
| 5 | Baths | One for every 8 pupils or part thereof | One for every 6 pupils or part thereof | _____ | _____ |
| 6 | Baths (showers) | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof | One for every 50 pupils or part thereof | One for every50pupils or part thereof |
| 7 | Cleaner's Sinks | One per Floor minimum | One per Floor minimum | OneperFloor minimum | One per Floor minimum |
Page | 114
Contd: Nursery Schools
| Sr. No. | Sanitary Unit | Requirement |
|---|---|---|
| 1 | Water Closet | One for 15 boys, one for 6 girls |
| 2 | Ablution Taps | One in each W.C. |
| 3 | Urinals | One for 12 boys |
| 4 | Wash Basins | One for every 15 pupils or part thereof |
| 5 | Baths | One bath per 40 pupils |
| 6 | Drinking Water Fountains | One for every 50 pupils or part thereof |
| 7 | Cleaner's Sink | One per Floor minimum |