8.1 Hospital, Commercial, Club
| Sr. No. | PARAMETERS | HOSPITAL | COMMERCIAL/HOTEL | CLUB |
| 1 | Set Backs/ No. of Storeys | As per Zoning Plan | ||
| 2 | FAR(max.) | 1.50 | 1.75/2.0 | 0.50 |
| 3 | Ground Coverage (max.) | 40% | ||
| 4 | Plinth | Minimum 0.3 m (1'-0"), Maximum 1.2 m (4'-0") | ||
| 5 | Height (max.) | 17.52 m (57'-6") | 22.63 m (74'-3") | 14.86 m (48'-9") |
| 6 | Toilet | Min. Area 2.8 Sq. m (30 Sq. Ft.) with Min. Width 1.20 m(4'-0") & Min. Height 2.29 m (7'-6") | ||
| 7 | WC and Powder Room | Min. Area 15 Sq. Ft. & 20 sq. ft. with Min. Width 0.90 m (3'-0") & Min. Height 2.29 m (7'-6") | ||
| 8 | Bath | Min. Area 1.85 Sq. m (20 Sq. Ft.) with Min. Width 1.20 m (4'-0") & Min. Height 2.29 m (7'-6") | ||
| 9 | Light & Ventilation | Minimum 1/8th of the floor area of the habitable space. | ||
| 10 | Ventilation Shaft | Height of building upto in m. Min size (in Sq.m.) Min width in m.10 1.2 0.9012 2.8 1.2018 4.0 1.5024 5.4 1.8030 8.0 2.40 | ||
| For fully air-conditioned buildings the ventilation shaft shall not be required, provided the air-conditioning system works on uninterrupted source of power supply. Horizontal ducting for ventilation may be installed in building with exhaust fan of appropriate capacity for discharging used air to external face of building. | ||||
| 11 | Staircase | Minimum width 2.0 m (6'-6") Minimum Tread 0.30 m (12"), Maximum Riser 0.150 m (6") The maximum numbers of risers in single flight are limited to 12. Height of railing/parapet shall be 0.90m (3'-0") to 1.07m. (3'-6"). | ||
| 12 | Lift & Ramp | Allowed. Lift is mandatory in buildings above15m height. Ramp (2.4m wide) with slope of 1:12 is mandatory in Hospital. | ||
| 13 | Mumty | Allowed within service zone | ||
| 14 | Services on terrace | Solar Water heating System, Solar Photo voltaic Power Plant, Water Tank | ||
Page | 46
and cooling towers for air conditioning plant, mumty, machine room, Screen Wall to encase the services etc. within the service zone.
| Sr. No. | PARAMETERS | HOSPITAL | COMMERCIAL | CLUB | ||
| 15 | Gate & Check Post | i) Main Gate 4.88 m (16'-0") with height upto 1.80 m (6'-0"). ii) The design of the gate is at the discretion of the owner. iii) Check Post (Optional) size maximum 14 Sq. m.. on each entry and exit. | ||||
| 16 | Boundary Wall | 1.13 m (3'-8 ½"). Railing above 0.69 m. (2'-3") high (optional) | ||||
| 17 | Basement | Mandatory (single level) below the zoned area. Use is for Non Habitable i.e. for parking, storage, services & utilities of the building. Minimum height 2.4 m (8'-0") below the beam/ roof slab, and is free from F.A.R. | ||||
| 18 | Ramp | Allowed in setback for basement parking only subject to Fire and Structural stability norms. Minimum width 4.0 m (single) & 8.0 m (Double) with 1: 10 slope. At curved portion of the ramp or for circular ramp the slope should not be more than1:12. | ||||
| 19 | Parking | 1 ECS for 05 Beds (Private) 1 ECS for 10 Beds ( Public) 1 ECS per 100 Sq.m.. for remaining area. | 3 ECS per 100 Sq.m. of built up area | 20% area of the site | ||
| 20 | Projection/Cantilever | Maximum 1.80 m(6'-0") within zoned area. | ||||
| 21 | Rain Water Harvesting System | Compulsory of adequate capacity. | ||||
| 22 | Solar Water Heating System | Compulsory of adequate capacity. | ||||
| 23 | Solar Photo Voltaic (Compulsory) | i) 50 kilo watt to 1000 Kilo Watt i) Minimum 10 Kilo watt peak Or 5% of connected load, Whichever is higher. ii) above 1000 Kilo Watt ii) Minimum 50 Kilo watt peak Or 3% of connected load, Whichever is higher. | ||||
| 24 | Flushing System | Dual flushing system of not more than 7 Ltr. Capacity per W.C. | ||||
| 25 | Parapet/ Railing | Minimum 1.0 m (3'-3") and max. 1.2m (4'-0") high parapet/railing at balcony/verandah etc. and service zone area. Railing/perforated screen 1.2 m (4'-0") high within the service zone in all floors where roof is accessed through mumty. | ||||
| 26 | Minimum Passage/Corridor | 2.4 m (8'-0") | Users Upto 100 -- 2.0 m. 101 and Above -- 2.40 m | |||
| 27 | Amalgamation/Fragmentation | Not Allowed | ||||
Note:-
Page | 47
i) Parking will only be allowed in basement/ stilt/ surface, wherever applicable. However, parking on upper floors shall not be allowed, other than standalone multilevel parking.
ii) The above provision shall be read along with the chapter on Miscellaneous Building Requirement & other chapters.
8.2 Residential & Government Housing
| Sr. No. | PARAMETERS | RESIDENTIAL | GOVERNMENT HOUSING |
| 1 | Set Backs/ No. of Storeys | As per zoning | |
| 2 | Ground Coverage (max.) | 40% | |
| 3 | FAR (max.) | 2.0 | |
| 4 | Plinth | Minimum 0.3 m (1'-0") Maximum 1.2 (4'-0") | |
| 5 | Height (max.) | 22.63 m (74'-3") | |
| 6 | Habitable Room | Min. Area 9.50 Sq. m (100 Sq. Ft.) with Min. Width 2.40 m (8'-0") & Min. Height 2.75 m(9'-0") and below beam 2.4 m (8'-0") | |
| 7 | Kitchen | Min. Area 4.50 Sq. m (49 Sq. Ft.) with Min. Width 1.50 m (5'-0") & Min. Height 2.75 m (9'-0") | |
| 8 | Toilet | Min. Area 2.8 Sq. m (30 Sq. Ft.) with Min. Width 1.20 m (4'-0") & Min. Height 2.29 m (7'-6") | |
| 9 | WC and Powder Room | Min. Area 15 Sq. Ft. & 20 sq. ft. with Min. Width 0.90 m (3'-0") & Min. Height 2.29 m (7'-6") | |
| 10 | Bath | Min. Area 1.85 Sq. m (20 Sq. Ft.) with Min. Width 1.20 m (4'-0") & Min. Height 2.29 m (7'-6") | |
| 11 | Light & Ventilation | Minimum 1/8th of the floor area of the habitable space | |
| 12 | Ventilation Shaft | Height of building upto in m. Min size (in Sq.m.) Min width in m.10 1.2 0.9012 2.8 1.2018 4.0 1.5024 5.4 1.8030 8.0 2.40 | |
| 13 | Interior Courtyard for light and | Height of building upto Interior open space to be left (in m.) out on all sides (front, rear and sides in each plot) in m. | |
Page | 48
| ventilation 10 | 3 |
|---|---|
| 15 | 5 |
| 18 | 6 |
| 21 | 7 |
| 24 | 8 |
| 27 | 9 |
| 30 | 10 |
| Sr.No. | PARAMETERS | RESIDENTIAL | GOVERNMENT HOUSING |
| 14 | Staircase | Minimum width 1.50 m (5'-0"), Minimum Tread 0.28m (11"), Maximum Riser 0.175 m (7") Height of railing/parapet shall be 0.90m (3'-0") to 1.07m. (3'-6"). | |
| 15 | Lift | Mandatory | |
| 16 | Mumty | Allowed within service zone | |
| 17 | Services on terrace | Solar Water heating System, Solar Photo voltaic Power Plant, Water Tank and cooling towers for air conditioning plant, mumty, machine room, Screen Wall to encase services etc. within the service zone. | |
| 18 | Gate | Main Gate 4.88 m (16'-0") with height upto 1.80 m (6'-0"). The design of the gate is at the discretion of the owner. | |
| 19 | Boundary Wall | 1.13 m (3'-8 1/2"). 0.69 m. (2'-3") high railing (optional) | |
| 20 | Basement | Compulsory (single level) below the zoned area.Use is for Non Habitable i.e. for parking, storage, services & utilities of the building.Minimum height 2.4 m (8'-0") below the beam/ roof slab, and is free from F.A.R. | |
| 21 | Stilt | Allowed, subject to construction of shear walls as per B.I.S. code.Minimum height 2.29 m (7'-6") below the beam/ roof slab. Use is for parking only and is free from F.A.R. | |
| 22 | Ramp | Allowed in setback for basement parking only subject to Fire and Structural stability norms.Minimum width 4.0 m (single) & 8.0 m (Double) with 1: 10 slope. At curved portion of the ramp or for circular ramp the slope should not be more than 1:12. | |
| 23 | Parking | 1.5 ECS per DU with unit area upto 111.48 Sq. m. (1200 Sq. Ft.)2.0 ECS per DU with unit area upto 278.70 Sq. m. (3000 Sq. Ft.)3.0 ECS per DU with unit area above 278.70 Sq. m. (3000 Sq. Ft.)10% guest parking shall also be provided on surface for visitors. | As per zoning plan |
Page | 49
| 24 | EWS/ Low Income Housing | 15% of the total dwelling unit. Minimum area 30sqm. One room 9 sqm and width of 2.5 m, Other room shall be min. 6.5 sqm with min. width of 2.1m) provided the total area of both the rooms shall not be less than 15.50 sqm. | ------ |
|---|---|---|---|
| 25 | Community Facilities | 4% area of the site. | Maximum 0.5% area of the site for need based shops. |
| Sr. No. | PARAMETERS | RESIDENTIAL | GOVERNMENT HOUSING |
| 26 | Projection/Canti lever/ Sunshade | Maximum 1.80 m (6'-0") | |
| 27 | Rain Water Harvesting System | Compulsory of adequate capacity. | |
| 28 | Solar Water Heating System | Compulsory of adequate capacity. | |
| 29 | Solar Photo Voltaic | i) 0.5 Acre to 1.0 Acs; i) Minimum 10 Kilo watt peak (KWp) ii) Up to 2.0 Acs; ii) Minimum 20 Kilo watt peak (KWp) iii) Upto 5.0 Acs; iii) Minimum 30 Kilo watt peak (KWp) iv) Above 5.0 Acres; iv) Minimum 40 Kilo watt peak (KWp | |
| 30 | Flushing System | Dual flushing system of not more than 7 Ltr. Capacity per W.C. | |
| 31 | Parapet/ Railing | Minimum 1.0 m (3'-3") and max. 1.2m (4'-0") high parapet/railing at balcony/verandah etc. and service zone area. Railing/perforated screen 1.2 m (4'-0") high within the service zone in all floors where roof is accessed through mumty. | |
| 32 | Minimum Passage/Corridor | Minimum 1.20 m (4'-0") for single loaded and 1.80 m (6'-0") for double loaded. Minimum clear height 2.4 m (8'-0") | |
| 33 | Amalgamation/Fragmentation | Not allowed | |
Note:-
i) Parking will only be allowed in basement/ stilt/ surface, wherever applicable. However, parking on upper floors shall not be allowed, other than standalone multilevel parking.
ii) The above provision shall be read alongwith the chapter on Miscellaneous Building Requirements & other chapters.
Page | 50
9 INTEGRATED PROJECTS
| Sr. No. | PARAMETERS | INSTITUTIONAL (70% of the Total Area) | RESIDENTIAL (25% of the Total Area) | COMMERCIAL (5% of the Total Plot area) |
| 1 | Plot Area Set Backs/ No. of Storeys | As per zoning plan | ||
| 2 | FAR (max.) 2.0 | |||
| 3 Ground 35% Coverage (max.) | 40% | 35% | ||
| 4 Plinth Minimum 0.3 m (1'-0"), Maximum 1.2 m (4'-0") | ||||
| 5 Height (max.) 25.48m (83'-7") | 22.86m (75'-0") | |||
| 6 Habitable Room Min. Area 9.50 Sq. m (100 Sq. Ft.) with Min. Width 2.40 m (8'-0") & Min. Height 2.75 m(9'-0") and below beam 2.4 m (8'-0") | ||||
| 7 Kitchen Min. Area 4.50 Sq. m (49 Sq. Ft.) with Min. Width 1.50 m (5'-0") & Min. Height 2.75 m (9'-0") | ||||
| 8 Toilet Min. Area 2.8 Sq. m (30 Sq. Ft.) with Min. Width 1.20 m (4'-0") & Min. Height 2.29 m (7'-6") | ||||
| 9 WC and Powder Min. Area 15 Sq. Ft. & 20 sq. ft. with Min. Width 0.90 m (3'-0") & Min. Height Room 2.29 m (7'-6") | ||||
| 10 Bath Min. Area 1.85 Sq. m (20 Sq. Ft.) with Min. Width 1.20 m (4'-0") & Min. Height 2.29 m (7'-6") | ||||
| 11 Light & Minimum 1/8th of the floor area of the habitable space. Ventilation | ||||
| 12 Ventilation Shaft Height of building upto in m.. Min size (in Sq. m) Min width in m.10 1.2 0.9012 2.8 1.20 | ||||
Page | 51
| Uploade | |||
| 18 | 4.0 1.50 | ||
| 24 | 5.4 1.80 | ||
| 30 | 8.0 2.40 | ||
| For fully air-conditioned buildings except residential the ventilation shaft shall not be required, provided the air-conditioning system works on uninterrupted source of power supply.Horizontal ducting for ventilation may be installed in building with exhaust fan of appropriate capacity for discharging used air to external face of building. | |||
| Sr. No. | PARAMETERS | INSTITUTIONAL (70% of the Total Area) | RESIDENTIAL (25% of the Total Area) | COMMERCIAL (5% of the Total Plot area) | ||
| 13 | Interior Courtyard For light and ventilation | Height of building upto Interior open space to be left (in m..) out on all sides (front, rear and sides in each plot) in m.10 315 518 621 724 827 930 10 | ||||
| 14 | Staircase | Min. Width 2.0 m(6'-6") | Min. Width 1.5 m(5'-0") | Min. Width 2.0 m(6'-6") | ||
| Minimum Tread 0.30 m (12"), Maximum Riser 0.15 m (6") The maximum numbers of risers in single flight are limited to 12. Height of railing/parapet shall be 0.90m (3'-0") to 1.07m. (3'-6"). | ||||||
| 15 | Lift & Ramp | Lift is mandatory. Ramp is mandatory in Educational & Hospital Building. Width of the ramp 2.4 m (8'-0") in hospital buildings. | ||||
| 16 | Mumty | Allowed within service zone | ||||
| 17 | Services on terrace | Solar Water heating System, Solar Photo voltaic Power Plant, Machine room, Water Tank, Screen Wall to encase services etc. within the service zone. | ||||
| 18 | Gate & Check Post | i) Main Gate 4.88 m (16'-0") with height upto 1.80 m (6'-0"). ii) The design of the gate is at the discretion of the owner. iii) Check Post (optional), maximum size 14 Sq. m on each entry and exit. | ||||
| 19 | Boundary Wall | 1.13 m (3'-8 ½"") with 0.69 m (2'-3") high railing above | ||||
| 20 | Basement | Compulsory (Single Level), below the zoned area, Use is for Non Habitable i.e. for parking, storage, services & utilities of the building. Minimum height 2.4 m (8'-0") below the beam/ roof slab, and is free from F.A.R. | ||||
Page | 52
| 21 | Ramp | Allowed in setback for basement parking only subject to Fire and Structural stability norms.Minimum width 4.0 m (single) & 8.0 m (Double) with 1: 10 slope. At curved portion of the ramp or for circular ramp the slope should not be more than 1:12. | ||
| 22 | Parking | Educational -2 ECS per 100 Sq. m + 2ECS per 100 Sq. m or fraction of Administrative Office Area.Hospital-1 ECS per 10 Beds (Public)1 ECS per 05 Beds (Private)Remaining 1 ECS per 100 Sq. m | 1 ECS per 100 Sq. m of built up area. | 3 ECS per 100 Sq. m |
| Sr. No. | PARAMETERS | INSTITUTIONAL (70% of the Total Area) | RESIDENTIAL (25% of the Total Area) | COMMERCIAL (5% of the Total Plot area) |
| 23 | Projection/Cantilever | Maximum 1.80 m (6'-0") within zoned area | ||
| 24 | Rain Water Harvesting System | Compulsory of adequate capacity. | ||
| 25 | Solar Water Heating System | Compulsory of adequate capacity. | ||
| 26 | Solar Photo Voltaic (Compulsory) | i) 50 kilo watt to 1000 Kilo Watt i) Minimum 10 Kilo watt peak Or 5% of connected load, Whichever is higher. ii) above 1000 Kilo Watt ii) Minimum 50 Kilo watt peak Or 3% of connected load, Whichever is higher. | ||
| 26 | Flushing System | Dual flushing system of not more than 7 Ltr. Capacity per W.C. | ||
| 30 | Parapet/ Railing | Minimum 1.0 m (3'-3") and max. 1.2m (4'-0") high parapet/railing at balcony/verandah etc. and service zone area. Railing/perforated screen 1.2 m (4'-0") high within the service zone in all floors where roof is accessed through mumty. | ||
| 31 | Minimum Passage/Corridor | Residential minimum 1.20 m (4'-0") for single loaded and 1.80 m (6'-0") for double loaded. For Hospitals min. width is 2.40 m (8'-0"), and For other buildings:- No. of users upto 100 =1.8 m (6'-0") No. of users 101and above =2.4 m (8'-0") with a min. clear height 2.4m (8'-0") | ||
| 32 | Amalgamation/Fragmentation | Not allowed | ||
Page | 53
Note:-
i) Parking will only be allowed in basement/ stilt/ surface, wherever applicable. However, parking on Upper floors shall not be allowed, other than standalone multilevel parking.
ii) The above provision shall be read along with the chapter on Miscellaneous Building Requirements& other chapters.
9.1 Transit Oriented Development
| Sr. No | Type of Building | Ground Coverage | FAR | Height |
| 1. | Residential Area (20% of total scheme) | 40% | 2.5 | 30.0 m.(98'-5") |
| 2. | Integrated Commercial Complexes including Hotels, Motels, Banquet halls etc. (20% of total scheme) | 40% | 3.0 | |
| 3. | Specialized Educational Institutes and Cultural Spaces including Auditoriums/ Museums/ Cultural Centres / Planetarium etc (15% of total scheme) | 40% | 3.0 | |
| 4. | Integrated Office Spaces. (20% of total scheme) | 40% | 3.0 | |
| 5 | Specialized Health care Institutes. (10% of total scheme) | 40% | 3.0 | |
| 6. | Traffic and Transportation/ Metro Stations/ Parking/ ISBT-43. (15% of total scheme) | 40% | 3.0 |