In these Rules, unless the context otherwise requires the definition given shall have the meaning indicated against each term, those not defined shall carry dictionary meaning.
-
“Abut” A building is said to abut on a street when the outer face of any of its external walls is on the street boundary.
-
“Act” shall mean the Capital of Punjab (Development and Regulation) Act, 1952.
-
“Access” - A clear approach to a plot or a building.
-
“Ancillary Zone” in the buildings means the building ancillary to and serving the main building and includes meter room, security room, Sewerage Treatment Plant, godown, guard room, cycle shed, dispensary, canteen, electric substation and labour quarters for watch and ward staff but shall not include residential accommodation for supervisory staff;
-
“Applicant” shall mean a person who gives notice to the Chief Administrator of his intention to erect or reerect a building and shall include his legal representatives.
-
“Application”- An application made in such form as may be prescribed by the Authority from time to time.
-
“Approved”- As approved/sanctioned by the Authority under applicable Rules.
-
“Architect” A person holding a graduate degree in Bachelor of Architecture from any institute recognised by the Council of Architecture (COA) and has his/ her name entered in the register of COA with a valid COA Registration number.
-
“Architectural Control Sheets” shall mean sheets of drawing with directions signed by the Chief Administrator and kept in his office showing the measure of architectural control which shall be observed in the special areas.
-
“Atrium” means a high open area or central court within multi-storeyed building and the covered area shall be counted in ground coverage/FAR.
-
“Balcony” shall mean a cantilevered horizontal projection from the wall of a building not supported from the ground having a balustrade or railing and intended for human use.
-
“Barsati” shall mean a roofed structure above the roof of a building used as shelter during the rains with or without toilet having non habitable height.
-
“Base” applied to a wall or column, shall mean the underside of that part of the wall or of the column which immediately rests upon the footing or foundation or upon any bressummer or other structure by which such wall or column is carried.
-
“Basement Storey” shall mean the storey which is next below the ground storey or which is in any part more than half of its height below the mean level of the street or ground adjoining the building
-
“Building” means any construction or part of a construction in Chandigarh which is transferred by the [Central Government] under section 3 of the Act and which is intended to be used for residential, commercial, industrial or other purposes, whether in actual use or not and includes any out-house, stable, cattle shed and also include any building erected on any land transferred by the Central Government under section 3 of the Act.
-
“Building line” shall mean a regulatory line specified in the zoning or architectural control for a site beyond which no building shall project within that site other than balcony, canopy, projection and compound wall.
-
“Cabin”- A non-residential enclosure constructed of non-load bearing partitions.
-
“Canopy” shall mean a projection from the top of the parapet wall or a continuation of a flat roof beyond the face of the outer wall designed to protect the wall from weather provided that.
a. It shall not project beyond the plot line.
b. It shall not be lower than 2.3 metres (clear height) when measured from the ground.
c. There shall be no structure on it and the top shall remain open to sky.
-
“Carpet Area” - The covered area of the usable rooms of a dwelling unit / at any floor (excluding the area of the walls).
-
“Chhajja” shall mean a continuous cantilevered horizontal or sloping projection from the outer wall of the building primarily intended to give protection from weather.
-
“Chimney”- A construction by means of which a flue is formed for the purpose of carrying products of combustion to the open air and includes a chimneystack and flue pipe.
-
“Class of building” shall mean a building in one of the following categories –
(a) “Residential building”:- shall mean a building used or constructed or adapted to be used wholly or principally for human habitation and includes all garages, or other out-buildings appurtenant thereto.
(b) “Commercial building”:- includes a building or complex or part thereof used as shops, stores or market for display and sale of wholesale and/ or retail goods or merchandise, including office, Restaurant, Banquet Hall, Hotel, Motel, Resort, Dhaba, Boarding house, Guest house, Amusement Park, office establishments and service facilities incidental thereto and located in the same building.
(c) “Warehouse and Industrial Building”:- includes a building or part thereof wherein products or material are fabricated, assembled or processed, such as assembly plant, cold storage, laboratory, power plant, refinery, gas plant, mill, dairy and factory etc.
(d) “Assembly Building” – A building or part thereof, where groups of people (not less than 50) congregate or gather for amusement, recreation, social, religious, patriotic, civil, travel and similar purposes.
(e) “Institutional Building” includes a building constructed by Government, Semi-Government Organization or Registered Trust/Society and use for medical or other treatment and care for persons suffering from physical or mental illness, disease or infirmity, care of orphans, differently-abled persons, abandoned women, children and infants, convalescents, destitute or aged persons and for penal or correctional detention with restricted liberty of the inmates ordinarily providing sleeping accommodation. It shall also includes an auditorium or complex for cultural, social, religious, patriotic and allied activities or for an hospice, assembly halls, city halls, town halls, exhibition halls, museums, places of ownership, dharamshala, hospital, sanatoria, custodial and penal institutions such as jail, prison, Government office, Secretariat, road or railway or air or sea or other public transportation station etc.:
(f) “Mixed land-use building’- includes a building consisting of one or more conforming uses/ activities duly allowed by competent authority;
(g) “Multi-Storeyed Building or High Rise Building”- A building above 4 stories, and/or a building exceeding 15 meters or more in height (without stilt) and 17.5m (including stilt).
-
“Clear height” means height from the top surface of ground or any floor to the soffit of beam or ceiling, as the case may be;
-
“Competent Authority” shall mean an officer/ agency duly authorized;
-
“Conversion”- The change from one occupancy to other occupancy or any change in building structure or part thereof resulting in a change of space and use requiring additional occupancy certificate.
-
'Courtyard' shall mean an area open to the sky but within the boundary of a plot, which is enclosed or partially enclosed by buildings, boundary walls or railings. It may be at ground floor level or any other level within or adjacent to a building.
-
“Covered Area”- The Ground area covered immediately above the plinth level covered by the building but does not include the space covered by:-
a) Garden, rockery, well and well structures, plant nursery, water pool, swimming pool (if uncovered), platform round a tree, tank, fountain, bench, chabutra with open top and unenclosed on sides by walls and the like;
b) . Drainage culvert, conduit, catch-pit, gully-pit, chamber, gutter and the like; Compound wall, gate, slide/ swing door, canopy, and areas covered by chajja or similar projections and staircases which are uncovered and open at least on three sides and also open to sky.
-
“Density”- The residential density expressed in terms of the number of dwelling units per acre. Note: Where such densities are expressed exclusive of community facilities and provision of open spaces and major roads (excluding incidental open spaces), these will be net residential densities. Where these densities are expressed taking into consideration the required open space provision and community facilities and major roads, these would be gross residential densities at neighbourhood level, sector level or town level, as the case may be. The provision of open spaces and community facilities will depend on the size of the residential community. Incidental open spaces are mainly open spaces required to be left around and in between two buildings to provide lighting and ventilation
-
“Damp Proof Course”- A course consisting of some appropriate water proofing material provided to prevent penetration of dampness or moisture.
-
“Drain”- A conduit or channel for the carriage of storm water, sewage, waste water or other waterborne wastes in a building drainage system.
-
“Drainage system” - A system or a line of pipes, with their fittings and accessories, such as manholes, inspection chambers, traps, gullies, floor traps used for drainage of building or yards appurtenant to the
buildings within the same cartilage; and includes an open channel for conveying surface water or a system for the removal of any waste water.
-
“Dwelling Unit”- means a building or a part thereof which is used or is intended to be used by a person or family for habitation comprising of kitchen, toilet and room.
-
“Electronic Signature/E-Signature” means digital signatures defined in the Information Technology Act, 2008
-
’Erection or re-erection’ of any building shall include, -
(a) Any material alteration or enlargement of any building ;
(b) The conversion by structural alteration into a place for habitation of any building not originally constructed for human habitation;
(c) The conversion into more than one place for human habitation of a building originally constructed as one such place;
(d) The conversion of two or more places of human habitation into a greater number of such places;
(e) Such alterations of a building as effect an alteration of its drainage or sanitation arrangements, or materially affect its security;
(f) The addition of any rooms, buildings, out-houses or other structure to any building;
(g) The construction in a wall adjoining a street or a land not belonging to the owner of the wall, of a door opening on the such street or land.
- “Exit”- A passage channel or means of egress from the building, its storey or floor to a street or, other open space of safety; whether horizontal, outside and vertical exits meaning as under:-
(a) Horizontal exit means an exit, which is a protected opening through or around a fire well or bridge connecting two or more buildings.
(b) Outside exit mean an exit from building to a public way to an open area leading to a public way or to an enclosed fire resistant passage leading to a public way.
(c) Vertical exit means an exit used for ascending or descending between two or more levels including stairway, fire towers, ramps and fire escapes.
-
“External Wall” shall mean an outer wall or vertical enclosure of any building not being a party wall even though adjoining to a wall of another building and it also means a wall abutting on an interior open space of any building. It does not mean an outer verandah wall.
-
“Factory” has the same meaning as in the Factories Act (Act LXIII of 1948).
-
“Fire and/or Emergency Alarm System”- Fire alarm system comprises of components for manually or automatically detecting a fire, initiating an alarm of fire and initiating other actions as appropriate.
-
“Floor”- The lower surface in a storey on which one normally walks in a building, and does not include a mezzanine floor. The floor at ground level with direct access to a street or open space shall be called as ground floor (level- 0); the floor above it shall be termed as level+1, with the next higher floor being termed as level + 2, and so on upwards. The floor lower than this shall be termed as level -1, level-2 and so on.
-
“Floor Area Ratio (FAR)”- The quotient obtained by dividing the combined covered area (plinth area) of all floors, excepting areas specifically exempted under these regulations, by the total area of the plot, viz.: -
Floor Area Ratio (FAR) =-