| Sr. No. | PARAMETERS | Dispensary Police Station Fire Station | Hospital | Community Centre/JanjGhar | Sports Stadium |
| 1 | Set Backs/ No. of Storeys | As per zoning | |||
| 2 | FAR (max.) | 1.25 | 1.50 | 0.75 | 0.25 |
| 3 | Ground Coverage (max.) | 40% | 40% | 40% | 15% |
| 4 | Plinth | Minimum 0.3 m (1'-0"), Maximum 1.2 m (4'-0") | |||
| 5 | Height (max.) | 14.86m(48'-9") | 17.52m (57'-6") | 12.20m (40'-0") | 14.86 m (48'-9") |
| 6 | Staircase | Minimum width in police / fire station 1.5 m Other buildings 2.0 m Minimum Tread 0.30 m (12") Minimum Riser 0.15 m (6") Height of railing/parapet shall be 0.90m (3'-0") to 1.07m. (3'-6"). | |||
| 7 | Habitable Room | Min. Area 9.50 Sq. m (100 Sq. Ft.) , Min. Height 2.75 m (9'-0") and below beam/ false ceiling or AC duct 2.4 m (8'-0") | |||
| 8 | Pantry | Min. Area 4.50 Sq. m (49 Sq. Ft.) with Min. Width 1.50 m (5'-0") & Min. Height 2.75 m (9'-0") | |||
| 9 | Toilet | Min. Area 2.8 Sq. m (30 Sq. Ft.) with Min. Width 1.20 m(4'-0") & Min. Height 2.29 m (7'-6") | |||
| 10 | WC & Powder room | Min. Area 15 Sq. Ft. & 20 sq. ft. with Min. Width 0.90 m (3'-0") & Min. Height 2.29 m (7'-6") | |||
| 11 | Bath | Min. Area 1.85 Sq. m (20 Sq. Ft.) with Min. Width 1.20 m(4'-0") & Min. Height 2.29 m (7'-6") | |||
| 12 | Light & Ventilation | Minimum 1/8th of the floor area of the habitable space. | |||
| 13 | Ventilation Shaft | Height of building upto in m. Min size (in Sq.m.) Min width in m.10 1.2 0.9012 2.8 1.2018 4.0 1.50 | |||
| For fully air-conditioned buildings the ventilation shaft shall not be required, provided the air-conditioning system works on uninterrupted source of power supply. Horizontal ducting for ventilation may be installed in building with exhaust fan of appropriate capacity for discharging used air to external face of | |||||
Page | 35
building.
| Sr. No. | PARAMETERS | Dispensary Police Station Fire Station | Hospital | Community Centre/Janj Ghar | Sports Stadium |
| 14 | Interior Courtyard for light and ventilation | Height of building upto Interior open space to be left (in m.) out on all sides (front, rear and sides in each plot) in m.10 315 518 6 | |||
| 15 | Lift and Ramp | Ramp (2.4m wide) with slope of 1:12 is mandatory in Dispensary and Hospital. Lift is mandatory in buildings above15m height. | |||
| 16 | Mumty | Allowed within service zone | |||
| 17 | Services on terrace | Solar Water heating System, Solar Photo voltaic Power Plant, Cooling Towers Air Conditioner Plant, Mumty, Machine room, Water Tank, Screen Wall to encase services etc. within the service zone. | |||
| 18 | Gate & Check Post | Main Gate 4.88 m (16'-0") with height upto 1.80 m (6'-0"). The design of the gate is at the discretion of the owner. Check Post (Optional) maximum size 14 Sq. m on each entry and exit. | |||
| 19 | Boundary Wall | 1.13 m (3'-8 1/2") with 0.69 m (2'-3") high railing above. | |||
| 20 | Basement | Compulsory in Hospital (single level), Optional for others. Use is for Non Habitable i.e. for parking, storage, services & utilities of the building. Minimum height 2.4 m (8'-0") below the beam/ roof slab, and is free from F.A.R. | |||
| 21 | Ramp | Allowed in setback for basement parking only subject to Fire and Structural stability norms. Minimum width 4.0 m (single) & 8.0 m (Double) with 1: 10 slope. At curved portion of the ramp or for circular ramp the slope should not be more than 1:12. | |||
| 22 | Parking | For Hospital & Dispensary-1 ECS for 5 Beds (Private) 1 ECS for 10 Beds ( Public) 1 ECS for 100 Sq. m. for remaining area For other buildings 20% of the area of the site. | |||
| 23 | Projection/Cantilever | Maximum 1.80 m (6'-0") within zoned area | |||
| 24 | Rain Water Harvesting System | Compulsory of adequate capacity. | |||
| 25 | Solar Water Heating System | Compulsory of adequate capacity. | |||
Page | 36
| Sr. No. | PARAMETERS | Dispensary Police Station Fire Station | Hospital | Community Centre/Janj Ghar | Sports Stadium |
| 26 | Solar Photo Voltaic (Compulsory) | For Private: i) 50 kilo watt to 1000 Kilo Watt i) Minimum 10 Kilo watt peak Or 5% of connected load, whichever is higher. ii) above 1000 Kilo Watt ii) Minimum 50 Kilo watt peak)Or 3% of connected load, whichever is higher. For Government Buildings : Minimum 2 Kilo watt peak (KWp) Or 5% of connected load, whichever is higher. | |||
| 27 | Flushing System | Dual flushing system of not more than 7 Ltr. Capacity per W.C. | |||
| 28 | Parapet/ Railing | Minimum 1.0 m (3'-3") and max. 1.2m (4'-0") high parapet/railing at balcony/verandah etc. and service zone area. Railing/perforated screen 1.2 m (4'-0") high within the service zone in all floors where roof is accessed through mumty. | |||
| 29 | Minimum Passage/ Corridor | Minimum width in police/ fire station 2.0 m Other buildings 2.4 m Minimum clear height 2.40 m (8'-0") | |||
| 30 | Amalgamation/Fragmentation | Not Allowed | |||
Note:-
i) Parking will only be allowed in basement/ stilt/ surface, wherever applicable. However, parking on upper floors shall not be allowed, other than standalone multilevel parking.
ii) The above provision shall be read along with the chapter on Miscellaneous Building Requirements & other chapters.
Page | 37
7.1 Cultural and Non Academic Institutional & Religious
| Sr. No. | PARAMETERS | Cultural and Non Academic Institutional Sites | Religious | |
| 1 | Set Backs/ No. of Storeys | As per Zoning Plan | ||
| 2 | FAR (max.) | 1.25 | 1.00 | |
| 3 | Ground Coverage (max.) | 40% | ||
| 4 | Plinth | Minimum 0.3 m (1'-0"), Maximum 1.2 m (4'-0") | ||
| 5 | Height (max.) | 14.86 m (48'-9") | 10.97 m (36'-0") | |
| 6 | Habitable Room | Min. Area 9.50 Sq. m (100 Sq. Ft.) , Min. Height 2.75 m (9'-0") and below beam/ false ceiling or AC duct 2.4 m (8'-0") | ||
| 7 | Toilet | Min. Area 2.8 Sq. m (30 Sq. Ft.) with Min. Width 1.20 m(4'-0") & Min. Height 2.29 m (7'-6") | ||
| 8 | WC and Powder Room | Min. Area 15 Sq. Ft. & 20 sq. ft. with Min. Width 0.90 m (3'-0") & Min. Height 2.29 m (7'-6") | ||
| 9 | Bath | Min. Area 1.85 Sq. m (20 Sq. Ft.) with Min. Width 1.20 m(4'-0") & Min. Height 2.29 m (7'-6") | ||
| 10 | Light & Ventilation | Minimum 1/8th of the floor area of the habitable space. | ||
| 11 | Ventilation Shaft | Height of building upto in m. Min size (in Sq.m.) Min width in m.10 1.2 0.9012 2.8 1.2018 4.0 1.50 | ||
| 12 | Interior Courtyard For light and ventilation | Height of building upto Interior open space to be left (in m.) out on all sides (front, rear and sides in each plot) in m.10 315 518 6 | ||
| 13 | Staircase | Minimum width 1.5 m (5'-0"), Minimum Tread 0.30 m (12"), Maximum Riser 0.15 m (6") Height of railing/parapet shall be 0.90m (3'-0") to 1.07m. (3'-6"). | ||
| 14 | Lift & Ramp | Allowed. | ||
| 15 | Ramp | Allowed in setback for basement parking only subject to Fire and Structural stability norms. Minimum width 4.0 m (single) & 8.0 m (Double) with 1: 10 slope. At curved portion of the ramp or for circular ramp the slope should not be more than | ||
Page | 38
| 1:12. |
|---|
| Sr. No. | PARAMETERS | Cultural and Non Academic Institutional Sites | Religious | |
| 16 | Mumty | Allowed within service zone | ||
| 17 | Services on terrace | Solar Water heating System, Solar Photo voltaic Power Plant, Air Conditioner Plant, Mumty, Machine room, Water Tank, Screen Wall to encase services etc. within the service zone i.e. 10'-0" away from front, rear and side walls And max. height is 10'-0'' above terrace level. | ||
| 18 | Gate & Check Post | i) Main Gate 4.88 m (16'-0") with height upto 1.80 m (5'-11 ½"). ii) The design of the gate is at the discretion of the owner. iii) Check Post (optional) maximum size 14 sq. m on each entry and exit. | ||
| 19 | Boundary Wall | 1.13 m. (3'-8 ½") with railing above 0.69m high (2'-3") | ||
| 20 | Basement | Allowed, below the zoned area. Use is for Non Habitable i.e. for parking, storage, services & utilities of the building. Minimum height 2.4 m (8'-0") below the beam/ roof slab, and is free from F.A.R. | ||
| 21 | Parking | 2 ECS per 100 Sq. Mt | 20% of the total plot area | |
| 22 | Projection/Cantilever | Maximum 1.80 m (6'-0") within zoned area | ||
| 23 | Rain Water Harvesting System | Compulsory | ||
| 24 | Solar Water Heating System | Compulsory | ||
| 25 | Solar Photo Voltaic | Minimum 5 Kilo watt peak (KWp) Or 5% of connected load, whichever is higher. | ||
| 26 | Flushing System | Dual flushing system of not more than 7 Ltr. Capacity per W.C. | ||
| 27 | Parapet/ Railing | Minimum 1.0 m (3'-3") and max. 1.2m (4'-0") high parapet/railing at balcony/verandah etc. and service zone area. Railing/perforated screen 1.2 m (4'-0") high within the service zone in all floors where roof is accessed through mumty. | ||
| 28 | Minimum Passage/ Corridor | No. of users upto 100 =1.8 m (6'-0") No. of users 101and above =2.4 m (8'-0") Minimum clear height 2.4 m (8'-0") | ||
| 29 | Amalgamation/Fragmentation | Not allowed | ||
Note:-
Page | 39
Parking will only be allowed in basement/ stilt/ surface, wherever applicable. However, parking on upper floors shall not be allowed, other than standalone multilevel parking.
ii) The above provision shall be read alongwith the chapter on Miscellaneous Building Requirements & other chapters.