One water tap with draining arrangements shall be provided for every 50 persons or part thereof, in the vicinity of water closets and urinal.
-
For teaching staff, the schedule of sanitary units to be provided shall be the same as in case of office Buildings
Sanitation Requirements for Institutional (Medical) Occupancy- Hospital
| Sr. No. | Sanitary Unit | Hospitals With indoor Patient Ward For Males & females | Hospitals With outdoor Patient Wards | ||
| For Males | For Females | ||||
| 1 | Toilet Suite (1WC+1Washbasin+1shower) | Private room upto 4 persons | For upto 4 patients | ||
| 2 | Water Closet (W.C.) | One for every 8 beds or part thereof | One for every 100 persons or part thereof | O ne for every 25 persons or part thereof | |
| 3 | Ablution taps | One in each W.C. | One in each W.C. | One in each W.C. | |
| 4 | Wash Basins | Two upto 30 bed; add one for every additional 30 beds; or part thereof | One for every 100 persons or part thereof | One for every 25 persons or part thereof. | |
| 5 | Baths with Shower | One bath with shower for every 8 beds or part thereof. | -- | -- | |
| 6 | Bed pan washing sink | One for each ward | -- | -- | |
| 7 | Cleaner' Sinks | One for each ward | One per floor minimum | One per floor minimum | |
| 8 | Kitchen sinks & dish Washers (where Kitchen is provided) | One for each ward | -- | -- | |
| 9 | Urinals | One for 30 beds (male wards) | One for every 50 persons or part thereof | ||
| 10 | Drinking water fountain | One for each ward | One for 500 persons or part thereof | ||
Contd: Administrative Buildings
| Sr. No. | Sanitary Unit | For Males | For Females |
| 1 | Toilet Suite (1WC+1Washbasin+ 1shower) | For individual doctor's/officer's rooms | |
| 2 | Water Closet (W.C.) | One for every 25 persons or part thereof | Two for every 25 persons or part thereof |
| 3 | Ablution Taps. | One in each W.C | One in each W.C |
| 4 | Wash Basins | One for every 25 persons or part thereof | One for every 25 persons or part thereof |
| 5 | Baths with Shower | One on each floor | One on each floor |
| 6 | Cleaner's Sink | One per floor minimum | One per floor minimum |
| 7 | Kitchen sinks & dish Washers (where Kitchen is provided) | One for each floor | One for each floor |
| 8 | Urinals | Nil upto 6 persons 1 for 7-20 persons 2 for 21-45 persons 3 for 46-70 persons 4 for 71-100 persons From 101 to 200 persons add at the rate of 3%; for over 200 persons add at the rate of 2.5%. | -- |
| 9 | Drinking water fountain | One for 100 persons or part thereof | |
Sanitation Requirements for Institutional (Medical) Occupancy- (staff quarters and Hostels)
| Sr. No. | Sanitary Unit | Doctor's Dormitories | Nurses Hostel | ||
| For Male Staff | For female staff | ||||
| 1 | Water Closet (W.C.) | One for 4 persons | One for 2 persons | One for 2 persons or part thereof Two for 13-25 | |
| 2 | Ablution Taps. | One in each W.C. | One in each W.C. | One in each W.C. O | |
| 3 | Wash Basins | One for every 8 persons or part thereof | One for every 8 persons or part thereof | One for every 8 persons or part thereof | |
| 4 | Baths with Shower | One for every 4 persons or part thereof | One for every 4 persons or part thereof | One for every 4 persons or part thereof | |
| 5 | Cleaner's Sink | One per floor minimum | One per floor minimum | One per floor minimum | |
| 6 | Drinking water fountain | One for 100 persons or part thereof | One for 100 persons or part thereof | ||
Page | 117
Sanitation Requirements for Governmental and Public Business Occupancy and Offices.
| Sr. No. | Sanitary Unit | For Male Personnel | For Female Personnel |
| 1 | Water Closet | One for 25 persons or part thereof | Two for 15 persons or part thereof |
| 2 | Ablution Taps | One in each W.C. | One in each W.C. |
| 3 | Urinals | Nil upto 6 persons 1 for 7-20 persons 2 for 21-45 persons 3 for 46-70 persons 4 for 71-100 persons From 101 to 200 add @ 3%; For over 200 persons add @ 2.5%. | ------- |
| 4 | Wash basins | One for every 25 persons or part thereof | One for every 25 persons or part thereof |
| 5 | Drinkingwater fountains | One for every 100 persons with a minimum of one on each floor | One for every 100 persons with a minimum of one on each floor |
| 6 | Cleaner's Sinks | One per floor minimum; preferably in or adjacent to sanitary rooms. | ------- |
| 7 | Executive Room / Conference Halls | Toilet Suite (1 WC, 1 washbasin, optional shower for 24 hr usages) Unit could be common for Male/Female or separate depending on the number of user of each facility | |
Note: One water tap with drainage arrangements shall be provided / 50 persons or part thereof in the vicinity.
Segregated sanitation facilities for Visitors in Public Buildings
| Sr. No. | Sanitary Unit | For Male Personnel | For Female Personnel |
|---|---|---|---|
| 1 | Public toilet near Railway Stations (24x7) a) Water Closet(W.C) b) Urinals c) Ablution taps | a) One for 100 users b) One unit per 300-500 users c) One in each W.C. | a) One for 50 users b) -- c) One in each W.C. |
| 2 | Public Toilet near market place/offices (for working hours) a) Water Closet b) Urinals c) Ablution taps | a) One for 100 users b) One unit per 200-300 users c) One in each W.C. | a) One for 50 users b) -- c) One in each W.C. |
| 3 | Public toilets near Public Buildings a) Water Closet b) Urinals c) Ablution taps | a) One for 100 users b) One unit per 200-300 users c) One in each W.C. | a) One for 50 users b) -- c) One in each W.C. |
Page | 118
The recommended enclosure-sizes for different facilities at visitors’ toilets
| Sr. No. | Description | Optimum (mm) | Minimum (mm)* |
|---|---|---|---|
| 1 | Water Closet enclosures | 900x1200 | 750x900 |
| 2 | Urinals (divided by partition walls) | 575x675 | 500x600 |
*In case of space constraint, the minimum sizes may be adopted
The recommended areas for different facilities at visitors’ toilets
| Sr. No. | Sanitary Unit | Dwelling with individual conveniences | Dwelling without individual conveniences |
|---|---|---|---|
| 1 | Bath Room | One provided with water tap | One for every two tenement |
| 2 | Water Closet (W.C.) | One | One for every two tenement |
| 3 | Sink (or Nahani) in the Floor | One | ----- |
| 4 | Water Tap | One | One with drainage arrangement in each tenement One in common bath rooms and common water closet. |
Note: Where only one water closet is provided in a dwelling, the bath and water closet shall be separately accommodated.
Sanitation Requirements for Assembly Occupancy Buildings (Cinema, Theaters, Auditoria. Etc.)
| Sr. No. | Sanitary Unit | For Public | For Staff | ||
| For Male | For female | For Male | For female | ||
| 1 | Water Closet (W.C.) | One for 100 persons upto 400 persons. For over 400 persons, add at the rate of 1 per 250 persons or part thereof | Four for 100 persons upto 200 persons. For over 200 persons add at the rate of 1 per 50 persons or part thereof | One for 15 persons. Two for 16-35 persons | Two for 1-12 persons. Four for 13-25 persons add at the rate of 1 per 6 persons or part thereof |
| 2 | Ablution Taps. | One in each W.C. | One in each W.C. | One in each W.C. | One in each W.C. |
| 3 | Urinals | One for 50 persons or part thereof | ------ | Nil upto 6 persons One for 7-20 persons Two for 21-45 persons | -------- |
| 4 | Wash Basins | One for every | One for every | One for 1-15 | One for 1- |
Page | 119
| 200 persons or part thereof | 200 persons or part thereof | persons Two for 16-35 | 12persons Two for 13-25persons | ||
| 5 | Drinking Water Fountain | One for 100 persons or part thereof | |||
| 6 | Cleaner's Sink | One per floor | |||
| 7 | Shower/Bathing | As per trade requirements | |||
Note: i) One water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals.
Sanitation Requirements for Assembly Buildings (Art, Galleries, Libraries and Museums).
| Sr. No. | Sanitary Unit | For Public | For Staff | ||
| For Male | For female | For Male | For female | ||
| 1 | Water Closet (W.C.) | ne for 200 persons upto 400 persons. For over 400 persons, add at the rate of 1 per 250 persons or part thereof | Four for 100 persons upto200persons. For over 200 persons, add at the rate of 1 per 50 persons or part thereof | One for 1-15 persons. Two for 16-35 persons. | Two for 1-12persons. Four for 13-25persons, add at the rate of 1 per 6 persons. |
| 2 | Ablution Taps. | One in each W.C. | One in each W.C. | One in each W.C. | One in each W.C. |
| 3 | Urinals | One for 50 persons or part thereof | ------ | Nil upto 6 persons One for 7-20 persons Two for 21-45 persons | -------- |
| 4 | Wash Basins | One for every 200 persons or part thereof. For over 400 persons, add at the rate of 1 per 250 persons or part thereof. | One for every200persons or part thereof. For over 200 persons, add at the rate of 1 per150persons or part thereof | One for 1-15 persons Two for 16-35 | One for 1-12 persons Two for 13-25persons |
| 5 | Drinking Water Fountain | One for 100 persons or part thereof | |||
| 6 | Cleaner's Sink | One per floor, minimum | |||
| 7 | Shower/Bathing | As per trade requirements | |||
Note: It may be assumed that two thirds of the numbers are males and one third females.
Page | 120
Sanitation Requirements for Restaurants
| Sr. No. | Sanitary Unit | For Public | For Staff | ||
| For Male | For female | For Male | For female | ||
| 1 | Water Closet (W.C.) | One per 50 seats upto 200 seats. For over 200 seats, add at the rate of 1 per 100 seats or part thereof | One per 25 seats upto 200 seats. For over 200 seats, add at the rate of 1 per 50 seats or part thereofthereof | One for 15 persons. 2 for 16-35 persons. 3 for 36-65 persons. 4 for 66-100 persons. | Two per 1-12 persons. 4 for 13-25 persons. 6 for 26-40 persons. 8 for 41-57 persons. 10 for 58-77 persons. 12 for 78-100persons. thereof |
| 2 | Ablution Taps. | One in each W.C. | One in each W.C. | One in each W.C. | One in each W.C. |
| 3 | Urinals | One for 50 persons or part thereof | ------ | Nil upto 6 persons. 1 for 7-20 persons. 2 for 21-45 persons. 3 for 46-70 persons. 4 for 71-100 persons. | -------- |
| 4 | Wash Basins | One for every 200 persons or part thereof | |||
| 5 | Kitchen Sinks & Dish Washer | One per each Kitchen | |||
| 6 | Cleaner's Sink | One per floor | |||
| 7 | Service Sink | One in the restaurant | |||