i. In basement, there shall be two staircases preferably in opposite directions as per the provisions of the fire safety rules and the National Building Code as amended from time to time.
ii. The setback area can be sunk for light& ventilation (upto 4’-6” deep from plinth and 6’-0” wide), provided fire tender movement is not hindered.
iii. The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) provided that the minimum clear headway under any beam shall not be less than 2.4 m. In the case of pitched roof, the average height of rooms shall not be less than 2.75 m. The minimum clear head room under a beam, folded plates or eaves shall be 2.4 m.
iv. No portion of a room shall be assumed to be lighted, if it is more than 7.5 metres or as stated in National Building Code, away from the opening provided for lighting that portion.
v. Where the lighting and ventilation requirements are not met through day lighting and natural ventilation, the same shall be ensured through artificial lighting and mechanical ventilation as per Part VIII Building Services Section I Lighting and ventilation of National Building Code of India published by the Bureau of Indian Standards.
vi. No room containing water-closet shall be used for any other purposes except as lavatory and no such room shall open directly into any kitchen or cooking space by a door/ window or another opening.
vii. Soil or ventilating pipes shall not be allowed on the exterior face of any building, provided these shall either be embedded in the walls or pipe ducts to be provided to accommodate them.
viii. A Staircase shall not be arranged around a lift shaft.
ix. All staircase and walls enclosing the staircases in public buildings and warehouse and industrial buildings shall be of fire-proof materials and flooring shall be antiskid.
x. The staircases in private portions of public buildings/ commercial buildings or warehouse and industrial buildings, not open to general public may be of width 1.0m (3’-3”).
xi. All the passages and corridors shall be naturally lighted and ventilated and if not possible, provision for artificial lighting and mechanical ventilation shall be made.
xii. The minimum clear height of a basement storey shall be 2.40 metres(8’-0”) and maximum height of the basement storey shall be up to 3.66 metres(12’) from floor to ceiling. However, in case of the services such as Printing Press, lifts, A.C. Plants, Electrical Panels, Filtration Plants, Laundry Plants or Machines relating with the services relating to the use of the site and provision of automated/stack parking related with the services relating to the use of the site, the clear height up to 16’-6” shall be allowed subject to the condition that no mezzanine floor shall be permitted after ensuring the structural stability and provision of the Fire Safety Rules.
xiii. Upto three levels of basement shall be allowed. However more than three level basements if
xiv. Basement shall not be constructed beyond the zoned area/ Architectural control sheet. In case existing adjacent building constructed without basement, setback of 2.4 metres shall be taken from the existing adjacent building subject to the fulfilment of structural stability to be ensured by the registered Structural Engineer.
xv. Basement can be allowed upto the entire zoned area for exclusive purpose of parking (minimum of 80%) and services/ storage (maximum of 20%) in non-residential buildings. Basement can be allowed only below the built up area of ground floor including the covered rear courtyard in Show Rooms, SCOs, SCFs, bay-shops and similar buildings.
xvi. In phase – I (Sectors 1 to 30) all the buildings/ sites except residential, shall continue to be governed by architectural control / Zoning Plan. All other sites/ plots in Chandigarh shall have a zoning plan/ volumetric guidelines duly approved by the Chief Administrator. In residential buildings, due to increase in ground coverage area/ FAR, the front building line will not change. The increased area will be first adjusted within the existing footprint of building. If need be, increased coverage can be adjusted on the rear side or on either sides of the existing building.
xvii. The Architect/ Structural Engineer shall be responsible for proper construction activities till completion certificate is issued. Afterwards, the responsibility of maintaining buildings as per the sanctioned plans lies with owner. However, the Architect/ Structural Engineer shall be held responsible in case the certificate furnished by them with regard to construction as per the Building Rules is found to be false.
xviii. The terraces of all buildings in Chandigarh except marla houses, single storey structure i.e. booths, bay shops, etc. shall be allowed to be accessed by staircase mumty to be located within the service zone to create refuge area in case of fire. The service zone on the terrace shall be allowed to have 4 feet high parapet wall all around, which shall not be used for any other purpose except for specified services.
xxi.
xix. All public buildings on plot sizes of 1 acre and above shall display the building plans within the site at an appropriate location clearly highlighting the entry, exit, fire escape routes and staircases, corridors, public areas general convenience, essential services.
xx. The initial sanctioning of the building plans for fresh construction shall remain mandatory as at present. But, if any realignment/readjustment of internal temporary partitions in the existing building is required at a later stage, the registered Architect, supervising the same shall ensure that the said changes are within building rules and architectural control/ zoning as applicable to that building and he shall submit a copy of the revised plan prior to the execution of work at site to the Estate Officer for record and reference along with a certificate conforming to the above conditions. In this case, re-sanctioning shall not be required. However, any change in structure or permanent features such as toilets, stairs, lifts, Public Health ducts shall not be permitted. The SDO (B) shall visit/inspect the premises within a period of 3 months and verify the same. If the construction is not as per revised building plan submitted by the architect or any infringement of Building Rules is detected or in other words certificate submitted by the Architect is found to be wrong; The Architect shall be held responsible for all consequences and action shall be initiated against him/her as per rules.
A zone on the terrace for services like machine room, stair cover (mumty), Solar Water Heating System, Solar Photo Voltaic Power Plant, Water Tanks and cooling towers for air conditioning plant, chimneys, Architectural features etc. and 1.2 m (4'-0") Railing/perforated screen wall be provided to encase these services within the service zone i.e. 3.0m (10’-0”) away from front, rear and end wall and its height is restricted to 3.0m (10’-0”) over and above the permissible height, However its height can be increased upto 7.0m and accordingly its distance from the building line on all sides will be increased proportionally i.e. equal to the height of the services. Railing/perforated screen 1.2 m (4'-0") is recommended within the service zone in all plots where roof is accessed through mumty.
xxii. Space for Silent Generating set, Transformer, pumps and sumps and other ancillary services, outside the zoned area of 2 kanal & above plots shall be allowed, subject to prior approval of Chandigarh Pollution Control Committee, Fire Department and the Electricity Department of Chandigarh Administration.
Fire escape staircase in the Commercial, Public, Assembly, Hotel buildings etc. with 24m height and above shall have a fire tower and in such a case width of the same shall not be less than the width of the main staircase. No combustible material shall be allowed in the fire tower.
xxiv. Multi level parking above the ground level shall also be allowed which shall be free from FAR. However, the footprint of the separate parking building block shall be counted upto 50% of the ground coverage permissible. In this block, no other use except parking, driver’s rest room with toilet, toll centre and any other facility which is essential for parking facility shall be allowed subject to condition that these facilities shall not exceed 150 sq. m. per 1000 ECS (Equivalent Car Space) of parking space or in multiple of that. Other parameters such as ground coverage, height etc. for such parking shall be governed by the existing rules for any other multi level building. Multi level mechanical parking shall also be permissible for which the norms shall be decided on case-to-case basis.
10.2 Gallery Floors and Mezzanine Floor
Where gallery floors and mezzanine floors are built, they shall comply with the following:-
i) They shall not be built in any room the height of which is less than 4.9 metre.
ii) Gallery floor shall not cover more than one-third and mezzanine floor shall not cover more than onefourth of the floor area of the rooms in which they occur; and
iii) They shall not be lower than 2.40 metres (8’-0”) when measured from the surface of the floor to the under surface of the gallery or the mezzanine floor.
iv) They shall not be sub-divided into smaller compartments.
v) They shall not be used as a kitchen.
10.3 Damp Proofing of Basement
The walls and floors of the basement shall be watertight and be so designed that the effects of the surrounding soil and moisture, if any, are taken into account in design and adequate damp proofing treatment is given.