Maximum / Additional F.A.R. upto 50% of the minimum F.A.R. shall be allowed/ permitted within the same height as under after the payment of conversion charges already fixed under the scheme.
Plot Area
Minimum FAR allowed
Maximum FAR achieved after allowing 50% of the minimum FAR for calculation of conversion
Upto 1 Acre
2.00
3.00
Above 1 Acre
1.75
2.625
At least 20% of the available FAR shall be used for public space which includes circulation areas and toilets.
2.
Seating capacity
Total seating capacity of the theatre shall not be more than that of existing Cinemas Theatres and it shall not be less than 75% of the sanctioned seating capacity
3.
Commercial area
Allowed up to the area under the cinema halls and projection rooms. If any existing cinema site has some Commercial area as a part of the original plan, the same shall be allowed over and above the commercial area allowed under this rule.
4.
Height (max.)
As per the Architectural Control Drawing applicable to the site or as per order of the Chandigarh Administration.
5
Toilet
Min. Area 2.8 Sq. m (30 Sq. Ft.) with Min. Width 1.20 m(4'-0") & Min. Height 2.29 m (7'-6")
6
WC and Powder room
Min. Area 15 Sq. Ft. & 20 sq. ft. with Min. Width 0.90 m (3'-0") & Min. Height 2.29 m (7'-6")
7
Bath
Min. Area 1.85 Sq. m (20 Sq. Ft.) with Min. Width 1.20 m (4'-0") & Min. Height 2.29 m (7'-6")
8
Staircase
Minimum width 2.0m Minimum Tread 0.30 m (12"), Maximum Riser 0.15 m (6") With a minimum clear height 2.4 m (8'-0") Height of railing/parapet shall be 0.90m (3'-0") to 1.07m. (3'-6").
9
Lift
Mandatory
10
Mumty
Allowed
11
Services on terrace
Solar Water heating System, Solar Photo voltaic Power Plant, Water Tank and cooling towers for air conditioning plant, mumty, machine room, Screen Wall to encase the services etc. within the service zone.
Page | 28
Sr. No.
PARAMETERS
NORMS
12
Basement
Compulsory (single level). Use is for Non Habitable i.e. for parking, storage, services & utilities of the building. Minimum height 2.4 m (8'-0") below the beam/ roof slab, and is free from F.A.R.
13
Ramp
Minimum width 4.0 m (single) & 8.0 m (Double) with 1: 10 slope. At curved portion of the ramp or for circular ramp the slope should not be more than 1:12.
14
Parking
3 ECS for per 100 sq m Of the covered area in respect of multiplex or cinema component + 30% of the total covered area of that component i.e. multiplex or cinema and 2 ECS per 100 sqm of the balance total commercial covered area including circulation area. Minimum 80% of the parking should be proposed underground to keep more open/ green area on surface.
15
Rain Water Harvesting System
Compulsory of adequate capacity.
16
Solar Water Heating System
Compulsory of adequate capacity.
17
Solar Photo Voltaic (Compulsory)
i) 50 kilo watt to 1000 Kilo Watt i) Minimum 10 Kilo watt peak Or 5% of connected load, Whichever is higher. ii) above 1000 Kilo Watt ii) Minimum 50 Kilo watt peak Or 3% of connected load, Whichever is higher.
18
Flushing System
Dual flushing system of not more than 7 Ltr. Capacity per W.C.
19
Parapet/ Railing
Minimum 1.0 m (3'-3") and max. 1.2m (4'-0") high parapet/railing at balcony/verandah etc. and service zone area. Railing/perforated screen 1.2 m (4'-0") high within the service zone in all floors where roof is accessed through mumty.
20
Minimum Passage/ Corridor
Number of users up to 100 ... 2.0 m (6'-6") Number of users 101 and above ... 2.40 m (8'-0") Minimum height 2.40 m (8'-0")
21
Amalgamation/Fragmentation
Not allowed
Note:-
upper floors shall not be allowed, other than standalone multilevel parking.
ii) The above provision shall be read alongwith the chapter on Miscellaneous Building Requirements & other chapters.
Chapter 5Commercial Use
5.1 Commercial (Governed By Architectural Controls)
Sr. No.
PARAMETERS
SCO'S/ SCF'S / BAYSHOP'S/ SEMI INDUSTRIAL/ BOOTHS ETC.
1
Plot Area, Set Backs, FAR, Height, Ground Coverage, Plinth, No. of Storey
As per applicable Architectural control sheet.
2
Habitable Rooms
Min. Area 9.50 Sq. m (100 Sq. Ft.) with Min. Width 2.40 m (8'-0")& Min. Height 2.75 m(9'-0") below the ceiling and below the beam/ false ceiling or A.C. duct 2.4 m (8'-0")
3
Toilet
Min. Area 2.8 Sq. m (30 Sq. Ft.) with Min. Width 1.20 m(4'-0") & Min. Height 2.29 m (7'-6")
4
WC & Powder room
Min. Area 15 Sq. Ft. & 20 sq. ft. with Min. Width 0.90 m (3'-0") & Min. Height 2.29 m (7'-6")
5
Bath
Min. Area 1.85 Sq. m (20 Sq. Ft.) with Min. Width 1.20 m (4'-0") & Min. Height 2.29 m (7'-6")
6
Light & Ventilation
Minimum 1/8th of the floor area of the habitable space or as per Architectural Control Sheet. In case of fully air conditioned building, the short fall of natural light and ventilation (if any) shall be met through artificial means and mechanical ventilation with 100% power backup as per NBC.
7
Ventilation Shaft
Minimum area 1.2 sq. m (13sq. ft.) with minimum width 0.90 m (3 ft.) For fully air-conditioned buildings the ventilation shaft shall not be required, provided the air-conditioning system works on uninterrupted source of power supply. Horizontal ducting for ventilation may be installed in building with exhaust fan of appropriate capacity for discharging used air to external face of building.
8
Staircase
SCF SCF converted into SCO (Single Bay) or SCO (Single Bay) SCO (Two Bay or Above)
Min. width- 1.00m(3'-3") Min. width -1.15m(3'-9") Min. width -1.50m (5'-0")
Minimum Tread 0.28 m (11"), Maximum Riser 0.175 m (7") Height of railing/parapet shall be 0.90m (3'-0") to 1.07m. (3'-6"). The maximum numbers of risers in single flight are limited to 12.
9
Lift
Optional (machine room less with extra height upto 1.0m. (3'-3") above
Page | 19
terrace level within service zone) or as specified in the Architectural Control Sheet. Compulsory for building above 15 m height.
10
Mumty
Allowed, (refer standard Drg.No.8-R, Job No.883 )
Sr. No.
PARAMETERS
SCO'S/ SCF'S / BAYSHOP'S/ SEMI INDUSTRIAL/ BOOTHS ETC.
11
Services On terrace
Solar Water heating System, Solar Photo voltaic Power Plant, Water Tank, Screen Wall to encase services etc. within the service zone i.e. 3.0m (10'-0") away from front, rear and end wall.
12
Basement
i) Optional or as specified in the applicable Architectural Control.ii) Use is for Non habitable use i.e. Storage, services & utilities of the building. Minimum height 2.4 m (8'-0") below the beam/ roof slab, and is free from F.A.R.iii) No basement is allowed in booths.iv) In case existing adjacent building is constructed without basement, a minimum setback of 2.4 m. (8'-0") shall be taken from the existing adjacent building subject to the fulfillment of structural stability to be ensured by the registered Structural Engineer.
13
Light & Ventilation In Basement
As shown in the Architectural Control Sheets.In case the basement is extended below the public corridor, the deficit in light and ventilation shall be proportionately increased subject to the fulfillment of fire safety norms and structural stability be ensured by the Registered Structural Engineer.
14
Solar Water Heating System
Compulsory in Lodging cum Restaurant/ Hotels, Nursing Homes or similar buildings which have use of hot water.
15
Solar Photo Voltaic (Compulsory)
i) 50 kilo watt to 1000 Kilo Watt i) Minimum 10 Kilo watt peak OR 5% of connected load, Whichever is higher.ii) above 1000 Kilo Watt ii) Minimum 50 Kilo watt peak OR 3% of connected load, Whichever is higher.
16
Flushing System
Dual flushing system of not more than 7 Ltr. Capacity per W.C.
17
DG Set
There shall be no objection in installing of a Silent Generating Set of capacity beyond 25 KVA in the basement, terrace (within service zone) or ground floor subject to the clearance by the Chandigarh Pollution Control Committee, Fire Department and the Electricity Department of Chandigarh Administration as per their norms.
18
Sub-Division
Maximum 4 Sub divisions allowed to be occupied by different tenants/ outlets, on each floor of a single bay shop with a minimum of 6ft. wide corridor and upto 8 partitions on a floor of double bay shop with 9ft. wide corridor where there are offices on both sides of it subject to provision of adequate forced fresh air circulation. To simplify
Page | 20
procedure, owner should only be required to submit the layout and deposit prescribed fee with Estate office.
Sr. No.
PARAMETERS
SCO'S/ SCF'S / BAYSHOP'S/ SEMI INDUSTRIAL/ BOOTHS ETC.
19
Amalgamation
i) Two or more adjoining sites with the same ownership shall be permissible. ii) The partial amalgamation offloors as temporary arrangement, if the owners of the two adjoining plots are different and both the buildings are rented to one party, entry/opening to the size of 1.80 m. (6'-0") wide can be allowed for connectivity at each floor as long as the tenancy is applicable subject to taking an affidavit from the owners of the S.C.O's.
20
Fragmentation
Not allowed
Note: -.
i) The above provision shall be read along with the chapter on Miscellaneous Building Requirements & other chapters.
ii) Internal planning of SCF is at the discretion of the owner, however covered area of shop–cum-flat on 2 n d floor for residential use only shall be allowed same as in case of conversion of SCF into SCO i.e. height, façade etc. subject to payment and prior approval of Competent Authority of Chandigarh Administration.
5.2 Commercial (Governed By Individual Zoning)
Sr. No.
PARAMETERS
HOTEL
MULTIPLEX/MALLS (specifically earmarked sites)
COMMERCIAL (converted from Industrial)
1
Set Backs/ Height/ No. of Storeys
As per Zoning Plan
2
FAR (max.)
1.50
1.25
2.0
3
Ground Coverage (max.)
35%
40%
2 kanal -60% Above 2 kanal - 50%
4
Plinth
Minimum 0.3 m (1'-0"), Maximum 1.2 m (4'-0") In 2 kanal sites (converted from industrial to commercial use), the front building line and height shall be kept as per the erstwhile Architectural Control Sheet.
5
Habitable Room
Min. Area 9.50 Sq. m (100 Sq. Ft.) with Min. Width 2.40 m (8'-0") & Min. Height 2.75 m(9'-0") and below the beam 2.4 m (8'-0")
6
Toilet
Min. Area 2.8 Sq. m (30 Sq. Ft.) with Min. Width 1.20 m (4'-0") & Min. Height 2.29 m (7'-6")
7
WC and Powder room
Min. Area 15 Sq. Ft. & 20 sq. ft. with Min. Width 0.90 m (3'-0") & Min. Height 2.29 m (7'-6")
8
Bath
Min. Area 1.85 Sq. m (20 Sq. Ft.) with Min. Width 1.20 m (4'-0") & Min. Height 2.29 m (7'-6")
9
Light & Ventilation
Minimum 1/8th of the floor area of the habitable space.
10
Ventilation Shaft
Height of building upto in m.. Min. size (in sq. m.) Min. width (in m.)10 1.2 0.9012 2.8 1.2018 4.0 1.5024 5.4 1.8030 8.0 2.40
11
Interior Courtyard for light and ventilation
Height of building upto Interior open space to be left (in m.) out on all sides (front, rear and sides in each plot) in m.10 3
Page | 22
15
5
18
6
21
7
24
8
27
9
30
10
Sr.No.
PARAMETERS
HOTEL
MULTIPLEX/MALLS
COMMERCIAL (converted from Industrial)
12
Staircase
For Multiplex/ Malls and Hospitals min. width is 2.00 m (6'-6"), and For other buildings min. width 1.50 m (5'-0"). Minimum Tread 0.30 m (12"), Maximum Riser 0.15 m (6") The maximum numbers of risers in single flight are limited to 12. Height of railing/parapet shall be 0.90m (3'-0") to 1.07m. (3'-6").
13
Lift
Compulsory for buildings above 15 m. height
14
Mumty/ machine room
Allowed within service zone
15
Services on terrace
Solar Water heating System, Solar Photo voltaic Power Plant, Machine room, Water Tank, Screen Wall to encase services etc. within the service zone.
16
Gate & Check Post
i) Main Gate 4.88 m (16'-0") with height upto 1.80 m (5'-11 1⁄2") ii) The design of the gate is at the discretion of the owner. iii) Check Post (optional) maximum size 14 Sq. m on each entry and exit.
17
Boundary Wall
1.13 m (3'-8 1⁄2"). Railing 0.69 m (2'-3") high above (optional)
18
Basement
Mandatory (single level), below the zoned area, Use is for Non Habitable i.e. parking, storage, services & utilities of the building. Minimum height 2.4 m (8'-0") below the beam/ roof slab, and is free from F.A.R.
19
Ramp
Allowed in setback for basement parking only subject to Fire and Structural stability norms. Minimum width 4.0 m (single) & 8.0 m (Double) with 1: 10 slope. At curved portion of the ramp or for circular ramp the slope should not be more than 1:12.
20
parking
2 ECS per 100 sq. m of built up area. Minimum 80% of the parking should be proposed underground to keep more open/ green area on surface.
3 ECS per 100 sqm of the covered area in respect of multiplex or cinema component + 30% Of the total covered area of that component i.e. Multiplex or cinema and 2 ECS per 100 sqm of the balance total commercial covered area including circulation area. Minimum 80% of the parking should be proposed underground To keep more open/ green
2kanal upto 1 Acre - 2 ECS/100 sq. m built up area. Above 1 Acre - 3ECS / 100 sq. m built up area. (Minimum 15% of total parking to be provided at surface level.)
Page | 23
area on surface
21
Projection/Balcony/Cantilever
Maximum 1.80 m (6'-0") within zoned area
22
Rain water Harvesting system
Compulsory of adequate capacity.
Sr. No.
PARAMETERS
HOTEL
MULTIPLEX/MALLS
COMMERCIAL (converted from Industrial)
23
Solar Water Heating System
Compulsory of adequate capacity.
24
Solar Photo Voltaic (Compulsory)
i) 50 kilo watt to 1000 Kilo Watt i) Minimum 10 Kilo watt peak Or 5% of connected load, Whichever is higher. ii) above 1000 Kilo Watt ii) Minimum 50 Kilo watt peak Or 3% of connected load, Whichever is higher.
25
Flushing System
Dual flushing system of not more than 7 Ltr. Capacity per W.C.
26
Parapet/ Railing
Minimum 1.0 m (3'-3") and max. 1.2m (4'-0") high parapet/railing at balcony/verandah etc. and service zone area. Railing/perforated screen 1.2 m (4'-0") high within the service zone in all floors where roof is accessed through mumty.
27
Minimum Passage/Corridor
For Multiplex/ Malls min. width is 2.0 m (6'-6") For other buildings No. of users upto 100 =1.8 m (6'-0") No. of users 101 & above =2.4 m (8'-0") Minimum clear height is 2.4 m (8'-0")
28.
Amalgamation/Fragmentation
Not allowed.
Allowed, or as per the Policy/Scheme of Chandigarh Administration.
Note:-
i) Parking will only be allowed in basement/ stilt/ surface, wherever applicable. However, parking on upper floors shall not be allowed, other than standalone multilevel parking.
ii) The above provision shall be read alongwith the chapter on Miscellaneous Building Requirements & other chapters.
Commercial (Governed By Individual Zoning)
Sr. No.
PARAMETERS
BANQUET HALL/ MARRIAGE PALACE
BULKBUILDING MATERIAL
TIMBER SITE (Single Storey)
1
Size ofplot
Minimum1 Acre
As per Allotment
2
Set Backs
As per Zoning Plan
3
FAR (max.)
0.80
0.60
Upto 0.60 (on payment )
4
Ground Coverage (max.)
40%
60%
60%
5
Plinth
Minimum 0.3 m (1'-0"), Maximum 1.2 m (4'-0") In Timber site as per the Architectural Control Sheet.
6
Height (max.)
10.97 m(36'-0")
7.54 m (24'-9")
3.88 m (12'-9")
7
No. of Storeys
As per Zoning Plan. In Timber site as per the Architectural Control Sheet.
8
Habitable room
Min. Area 9.50 Sq. m (100 Sq.ft.) with Min. Width 2.40 m. (8'-0") & Min. Height 2.75 m (9'-0") and below the beam 2.4 m. (8'-0") .
9
Toilet
Min. Area 2.8 Sq. m (30 Sq. Ft.) with Min. Width 1.20 m (4'-0") & Min. Height 2.29 m (7'-6")
10
WC and Powder room
Min. Area 15 Sq. Ft. & 20 sq. ft. with Min. Width 0.90 m (3'-0") & Min. Height 2.29 m (7'-6")
11
Bath
Min. Area 1.85 Sq. m (20 Sq. Ft.) with Min. Width 1.20 m(4'-0") & Min. Height 2.29 m (7'-6")
12
Light & Ventilation
Minimum 1/8th of the floor area of the habitable space.
13
Ventilation Shaft
Minimum area 1.2 sq. m (13sq. ft.) with minimum width 0.90 m (3 ft.)
14
Staircase
Min. width 2.00 m(6'-6"),
Min. width 1.50 m(5'-0").
----
Minimum Tread 0.30 m(12"), Maximum Riser 0.15 m (6") The maximum numbers of risers in single flight are limited to 12. Height of railing/parapet shall be 0.90m (3'-0") to 1.07m. (3'-6").
15
Lift / Mumty
Optional within service zone
16
Services on terrace
Solar Water heating System, Solar Photo voltaic Power Plant, Water Tank, Screen Wall to encase services etc. within the service zone i.e.3.0M (10 feet) away from front, rear & end wall with maximum height 3 m (10'-0").
17
Page | 25
iii) Check Post (optional) maximum size 14 Sq. m on each entry & exit. iv) As per the Architectural Control Sheet in Timber site.
18
Boundary Wall
1.13 m (3'-8 ½"). Railing 0.69m (2'-3") high above (optional). In Bulk building material 1.80m (5'-11 ½") In Timber site, as per the Architectural Control Sheet.
Sr. No.
PARAMETERS
BANQUET HALL/ MARRIAGE PALACE
BULK BUILDING MATERIAL
TIMBER SITE (Single Storey)
19
Basement
Mandatory (single level) in Banquet hall/ Marriage palaces, below the zoned area, Optional in Bulk building material sites. Not allowed in timber sites. Use is for Non Habitable i.e. for parking, storage, services & utilities of the building. Minimum height 2.4 m (8'-0") below the beam/ roof slab, and is free from F.A.R.
20
Ramp
Allowed in setback for basement parking only subject to Fire and Structural stability norms. Minimum width 4.0 m (single) & 8.0 m (Double) with 1: 10 slope. At curved portion of the ramp or for circular ramp the slope should not be more than 1:12.
21
Parking
Atleast 130 cars per acres of gross area and further on pro rata basis
1 ECS per 100 sqm of the covered area
In Timber site as per the Architectural Control Sheet.
22
Projection/Cantilever/Balcony
Maximum 1.80 m (6'-0") within zoned area. In Timber site, as per the Architectural Control Sheet.
23
Rain Water Harvesting System
Compulsory of adequate capacity.
24
Solar Water Heating System
Compulsory of adequate capacity.
25
Solar Photo Voltaic (Compulsory)
i) 50 kilo watt to 1000 Kilo Watt i) Minimum 10 Kilo watt peak or 5% of connected load, whichever is higher. ii) above 1000 Kilo Watt ii) Minimum 50 Kilo watt peak) or 3% of connected load, whichever is higher.
26
Flushing System
Dual flushing system of not more than 7 Ltr. Capacity per W.C.
27
Parapet/ Railing
Minimum 1.0 m (3'-3") and max. 1.2m (4'-0") high parapet/railing at balcony/verandah etc. and service zone area. Railing/perforated screen 1.2 m (4'-0") high within the service zone in all floors where roof is accessed through
Page | 26
mumty.
28
Minimum Passage/ Corridor
2.0m (6'-6")
1.5m (5'-0")
Minimum clear height is 2.4 m (8'-0")
29
Amalgamation/Fragmentation
Not Allowed
Note:-
i) Parking will only be allowed in basement/ stilt/ surface, wherever applicable. However, parking on upper floors shall not be allowed, other than standalone multilevel parking.
ii) The above provision shall be read along with the chapter on Miscellaneous Building Requirements & other chapters.
Page | 27
Gate & Check Post
i) Main Gate 4.88 m (16'-0") with height upto 1.80 m (6'-0"). ii) The design of the gate is at the discretion of the owner.