Rates of conversion of residential premises into non-nuisance professional services for 25% of the covered area of the premises or 50 square metres whichever is less.
Potential Zone as notified under the Punjab Scheduled Roads and Controlled area Restriction on Unregulated Development Act, 1963 and Rules, 1965
Hyper potential
High potential
Medium potential
Low potential
Rs. 0.60 Lac
Rs. 0.50 Lac
Rs. 0.30 Lac
Rs. 0.20 Lac.
Specimen
Model Zoning Clauses for Different Building Types
1. Model Zoning Clauses for Residential Building
i. Code referred in the clause is Haryana Building Code, 2017, amended from time to time.
ii. SHAPE & SIZE OF SITE.
The shape and size of site is in accordance with the demarcation plan shown as ‘ ’ to ‘ ’, as confirmed by Competent Authority, vide drawing no…………….., issued on DD/MM/YYYY.
iii. LAND USE.
The type of buildings use permissible is residential and under no circumstance, the use of building shall be changed.
Iv. Type of Building Permitted and Land Use Zones.
The site shall be developed and building constructed thereon as indicated in and explained in the table below:
Notation
Land Use Zone
Type of Building permitted/permissible structure
Open Space Zone
Open parking, garden, landscaping features, underground services etc.
Building Zone
Building as per permissible land use in clause-iii above and uses permissible in the open space zone.
(a) The building or buildings shall be constructed only within the portion of the site marked as Building zone as explained above, and nowhere else.
(b) The proportion up to which the site can be covered with building or buildings on the ground floor and subsequent floors shall be as per Code 6.3(3)(i)(a).
(c) Maximum permissible FAR shall be as per Code 6.3(3)(i)(a).
The height of the building block, subject of course to the provisions of the site coverage and FAR, shall be governed by the following:-
(a) The maximum height of the buildings shall be as Code 6.3(3)(i)(a) and Code 6.3(3)(vii).
(b) If a building abuts on two or more streets of different widths, the buildings shall be deemed to face upon the street that has the greater width and the
[136]
height of the buildings shall be regulated by the width of that street and may be continued to this height to a depth of 24 metres, along the narrow street.
(c) The plinth height of building shall be as per Code 7.3.
(d) All building block(s) shall be constructed so as to maintain an inter-se distance as per Code 7.11(5).
(e) If such interior or exterior open space is intended to be used for the benefit of more than one building belonging to the same owner, then the width of such open air space shall be the one specified for the tallest building as specified in (c) above.
vii. PARKING.
(a) Adequate parking spaces, covered, open or in the basement shall be provided for vehicles of users and occupiers, within the site as per Code 7.1.
(b) In no circumstance, the vehicle(s) belonging to the plot shall be parked outside the plot area.
viii. APPROACH TO SITE.
(a) The vehicular approach to the site shall be planned and provided giving due consideration to the junctions of and the junctions with the surrounding roads to the satisfaction of the Competent Authority.
(b) The approach to the site shall be shown on the zoning plan.
Ix. BAR on Sub-division of Site.
Sub-division of the site shall not be permitted, in any circumstances.
X. Approval of Building Plans.
The building plans of the buildings to be constructed at site shall have to be got approved from the Competent Authority/ any other persons authorized by him, under the provisions of the respective Acts, before starting up the construction.
xi. BASEMENT. Basements within the building zone of the site shall be provided as per Code 6.3(3)(i)(a) and shall be constructed, used and maintained as per Code 7.16.
xii. BOUNDARY WALL.
The boundary wall shall be constructed as per Code 7.5.
xiii. PLANNING NORMS.
The building to be constructed shall be planned and designed to the norms and standards as per Chapter-7 of the Haryana Building Code, 2017, and as approved by the Competent Authority.
Xiv. Provisions of Public Health Facilities.
The W.C. and urinals provided in the buildings shall conform to Chapter 11 of the Haryana Building Code, 2017 and National Building Code, 2005.
Xv. External Finishes.
type of materials like bricks, stone, concrete, terracotta, grits, marble, chips, class metals or any other finish which may be allowed by the Competent Authority.
(b) The water storage tanks and plumbing works shall not be visible on any face of the building and shall be suitably encased.
(c) All sign boards and names shall be written on the spaces provided on buildings as per approved buildings plans specifically for this purpose and at no other places, whatsoever.
(d) For building services, plumbing services, construction practice, building material, foundation and Damp Proof Course Chapter 10 of the Haryana Building Code, 2017 shall be followed.
[137]
Xvi. Lifts and Ramps:
(a) Lift and Ramps in building shall be provided as per Code 7.7.
(b) Lift shall be preferably with 100% standby generators along with automatic switchover along with staircase of required width and number.
(c) If lift cannot be provided as per (b) above, ramps shall be provided conforming to the requirement of clause-3 of Annexure D-3 of Part-3 of National Building Code, 2005
xvii. BUILDING BYE-LAWS:
The construction of the building/ buildings shall be governed by provisions of the Haryana Building Code, 2017.
xviii. FIRE SAFETY MEASURES:
(a) The owner will ensure the provision of proper fire safety measures in the multi storied buildings conforming to the provisions of The Haryana Building Code, 2017/ National Building Code of India and the same should be got certified form the Competent Authority.
(b) Electric Sub Station/ generator room if provided should be on solid ground near DG/ LT. Control panel on ground floor or in upper basement and it should be located on outer periphery of the building, the same should be got approved from the Chief Electrical Inspector, Haryana.
(c) To ensure fire fighting scheme shall be got approved from the Director, Urban Local Bodies, Haryana or any person authorized by the Director, Urban Local Bodies, Haryana. This approval shall be obtained prior to starting the construction work at site.
xix. The rain water harvesting system shall be provided as per Code 8.1.
xx. That the owner shall ensure the installation of Light-Emitting Diode lamps (LED) for its building.
xxi. That the owner shall strictly comply with the Code 8.3 for enforcement of the Energy Conservation Building Codes.
xxii. That the owner shall ensure the installation of Solar Power Plant as per Code 8.2.
2. Model Zoning Clauses FOR Commercial Building
i. Code referred in the clause is Haryana Building Code, 2017, amended from time to time.
Ii. Shape & Size of Site.
The shape and size of site is in accordance with the demarcation plan shown as ‘ ’ to ‘ ’, as confirmed by Competent Authority, vide drawing no…………….., issued on DD/MM/YYYY.
iii. LAND USE.
The type of buildings use permissible is commercial for retail outlet/ showroom/ shop/ etc. and under no circumstance, the use of building shall be changed.
Iv. Type of Building Permitted and Land Use Zones.
(a) The type of buildings permitted on this site shall be buildings designated and intended to be used for:
(i) retail outlet including saleroom for lubricants, office room, toilet, store installation of fuel pumps, air filling pumps, underground storage of petrol/ diesel, canopy and way side amenities, like repairs/services shop, ATMs & small eating place (Dhaba/ Fast Food Joint). Fuel tanks shall be provided underground within the site after leaving 1.5 mtrs from the boundary.
(ii) Showroom/ shops including sale of goods.
[138]
(b) No other building use shall not be permitted.
(c) The site shall be developed and building constructed thereon as indicated in and explained in the table below:
Notation
Land Use Zone
Type of Building permitted/permissible structure
Open Space Zone
Open parking, garden, landscaping features, underground services etc.
Building Zone
Building as per permissible land use in clause-iii above and uses permissible in the open space zone.
(a) The building or buildings shall be constructed only within the portion of the site marked as Building zone as explained above, and nowhere else.
(b) The proportion up to which the site can be covered with building or buildings on the ground floor and subsequent floors shall be as per Code 6.3(3)(ii).
(c) Maximum permissible FAR shall be as per Code 6.3(3)(ii).
The height of the building block, subject of course to the provisions of the site coverage and FAR, shall be governed by the following:-
(a) The maximum height of the buildings shall be as Code 6.3(3)(ii) and Code 6.3(3)(vii).
(b) If a building abuts on two or more streets of different widths, the buildings shall be deemed to face upon the street that has the greater width and the height of the buildings shall be regulated by the width of that street and may be continued to this height to a depth of 24 metres, along the narrow street.
(c) The plinth height of building shall be as per Code 7.3.
(d) All building block(s) shall be constructed so as to maintain an inter-se distance as per Code 7.11(5).
(e) If such interior or exterior open space is intended to be used for the benefit of more than one building belonging to the same owner, then the width of such open air space shall be the one specified for the tallest building as specified in (c) above.
vii. PARKING.
(a) Adequate parking spaces, covered, open or in the basement shall be provided for vehicles of users and occupiers, within the site as per Code 7.1.
(b) In no circumstance, the vehicle(s) belonging/ related to the plot/ premises shall be parked outside the plot area.
viii. APPROACH TO SITE.
(a) The vehicular approach to the site shall be planned and provided giving due consideration to the junctions of and the junctions with the surrounding roads to the satisfaction of the Competent Authority.
(b) The approach to the site shall be shown on the zoning plan.
(c) Entry and Exit shall be permitted as indicated/ marked on the plan.
(d) In case of retail outlet no gate and gatepost shall be permitted.
Ix. BAR on Sub-division of Site.
Sub-division of the site shall not be permitted, in any circumstances.
[139]
X. Approval of Building Plans.
The building plans of the buildings to be constructed at site shall have to be got approved from the Competent Authority/ any other persons authorized by him, under the provisions of the respective Acts, before starting up the construction.
xi. BASEMENT.
(a) Basements within the building zone of the site shall be provided as per Code 6.3(3)(ii) and shall be constructed, used and maintained as per Code 7.16.
(b) In case of retail outlet basement is not permitted.
Xii. Planning Norms.
The building to be constructed shall be planned and designed to the norms and standards as per Chapter-7 of the Haryana Building Code, 2017, and as approved by the Competent Authority.
Xiii. Provisions of Public Health Facilities.
The W.C. and urinals provided in the buildings shall conform to Chapter 11 of the Haryana Building Code, 2017 and National Building Code, 2005.
Xiv. External Finishes.
(a) The external wall finishes, so far as possible shall be in natural or permanent type of materials like bricks, stone, concrete, terracotta, grits, marble, chips, class metals or any other finish which may be allowed by the Competent Authority.
(b) The water storage tanks and plumbing works shall not be visible on any face of the building and shall be suitably encased.
(c) All sign boards and names shall be written on the spaces provided on buildings as per approved buildings plans specifically for this purpose and at no other places, whatsoever.
(d) For building services, plumbing services, construction practice, building material, foundation and Damp Proof Course Chapter 10 of the Haryana Building Code, 2017 shall be followed.
Xv. Lifts and Ramps:
(a) Lift and Ramps in building shall be provided as per Code 7.7.
(b) Lift shall be preferably with 100% standby generators along with automatic switchover along with staircase of required width and number.
(c) If lift cannot be provided as per (b) above, ramps shall be provided conforming to the requirement of clause-3 of Annexure D-3 of Part-3 of National Building Code, 2005
(d) Not applicable in case of retail outlet.
Xvi. Building Bye-laws:
The construction of the building/ buildings shall be governed by provisions of the Haryana Building Code, 2017.
Xvii. Fire Safety Measures:
(a) The owner will ensure the provision of proper fire safety measures in the multi storied buildings conforming to the provisions of The Haryana Building Code, 2017/ National Building Code of India and the same should be got certified form the Competent Authority.
(b) Electric Sub Station/ generator room if provided should be on solid ground near DG/ LT. Control panel on ground floor or in upper basement and it should be located on outer periphery of the building, the same should be got approved from the Chief Electrical Inspector, Haryana.
(c) To ensure fire fighting scheme shall be got approved from the Director, Urban Local Bodies, Haryana or any person authorized by the Director, Urban Local
[140]
Bodies, Haryana. This approval shall be obtained prior to starting the construction work at site.
xviii. The rain water harvesting system shall be provided as per Code 8.1.
xix. That the owner shall ensure the installation of Light-Emitting Diode lamps (LED) for its building.
xx. That the owner shall strictly comply with the Code 8.3 for enforcement of the Energy Conservation Building Codes.
xxi. That the owner shall ensure the installation of Solar Power Plant as per Code 8.2. xxii. GENERAL
(a) Among other plans and papers detailed elevations of buildings along all sides exposed to public view shall be drawn according to scale as mentioned in the Haryana Building Code-2017.
(b) The water storage tanks and other plumbing works etc. shall not be exposed to view each face of building but shall be suitably encased.
(c) No applied decoration like inscription, crosses, names of persons or buildings are permitted on any external face of the building.
(d) The building design for the permissible covered area shall be submitted as a whole and not in parts.
(e) Provision for flickering amber light shall be as approved in the building plans for the retail outlet site the petrol pump is commissioned (in case of retail Outlet only).
(f) Sign boards for entry or exit shall be displayed within the site and shall be provided with proper lighting i.e. green light for entry board and red light for exit board (in case of retail Outlet only).
(g) The owner of the retail outlet shall not utilize the portion of the road reservation in front of the site for any purpose whatsoever (in case of retail Outlet only).
(h) Garbage collection center of appropriate size shall be provided within the site.
(i) Color trade emblem and other symbols shall be subject to the approval of the Competent Authority.
(j) No advertisement shall be permitted (in case of retail Outlet only).
3. Model Zoning Clauses for Educational and Institutional Building
i. Codereferred in the clause is Haryana Building Code, 2017, amended from time to time.
Ii. Shape & Size of Site.
The shape and size of site is in accordance with the demarcation plan shown as ‘ ’ to ‘ as confirmed by Competent Authority, vide drawing no…………….., issued on DD/MM/YYYY.
iii. LAND USE.
The type of buildings use permissible is Primary/ Higher/ Secondary School/ College in accordance to permission granted by Competent Authority. and under no circumstance, the use of building shall be changed.
Iv. Type of Building Permitted and Land Use Zones.
(a) The type of buildings permitted on this site shall be buildings designated and intended to be used for imparting education through day or evening classes. It may include residence for Principal/ Warden/ or other teaching staff, watch and ward stuff and other administrative staff along with hostels for students, extension counter of post office and bank as may be permitted by Competent Authority, subject to maximum limit of 15% of the permissible FAR..
[141]
(b) The site shall be developed and building constructed thereon as indicated in and explained in the table below:
Notation
Land Use Zone
Type of Building permitted/permissible structure
Open Space Zone
Open parking, garden, landscaping features, underground services etc.
Building Zone
Building as per permissible land use in clause-iii above and uses permissible in the open space zone.
(a) The building or buildings shall be constructed only within the portion of the site marked as Building zone as explained above, and nowhere else.
(b) The proportion up to which the site can be covered with building or buildings on the ground floor and subsequent floors shall be as per Code 6.3(3)(iii).
(c) Maximum permissible FAR shall be as per Code 6.3(3)(iii).
The height of the building block, subject of course to the provisions of the site coverage and FAR, shall be governed by the following:-
(a) The maximum height of the buildings shall be as Code 6.3(3)(iii) and Code 6.3(3)(vii).
(b) If a building abuts on two or more streets of different widths, the buildings shall be deemed to face upon the street that has the greater width and the height of the buildings shall be regulated by the width of that street and may be continued to this height to a depth of 24 metres, along the narrow street.
(c) The plinth height of building shall be as per Code 7.3.
(d) All building block(s) shall be constructed so as to maintain an inter-se distance as per Code 7.11(5).
(e) If such interior or exterior open space is intended to be used for the benefit of more than one building belonging to the same owner, then the width of such open air space shall be the one specified for the tallest building as specified in (c) above.
Xiv. External Finishes.
(a) The external wall finishes, so far as possible shall be in natural or permanent type of materials like bricks, stone, concrete, terracotta, grits, marble, chips, class metals or any other finish which may be allowed by the Competent Authority.
(b) The water storage tanks and plumbing works shall not be visible on any face of the building and shall be suitably encased.
(c) All sign boards and names shall be written on the spaces provided on buildings as per approved buildings plans specifically for this purpose and at no other places, whatsoever.
(d) For building services, plumbing services, construction practice, building material, foundation and Damp Proof Course Chapter 10 of the Haryana Building Code, 2017 shall be followed.
Xv. Lifts and Ramps:
(a) Lift and Ramps in building shall be provided as per Code 7.7.
(b) Lift shall be with 100% standby generators along with automatic switchover along with staircase of required width and number.
(c) If lift cannot be provided as per (b) above, ramps shall be provided conforming to the requirement of clause-3 of Annexure D-3 of Part-3 of National Building Code, 2005
Xvi. Building Bye-laws:
The construction of the building/ buildings shall be governed by provisions of the Haryana Building Code, 2017.
Xvii. Fire Safety Measures:
(a) The owner will ensure the provision of proper fire safety measures in the multi storeyed buildings conforming to the provisions of The Haryana Building Code, 2017/ National Building Code of India and the same should be got certified form the Competent Authority.
(b) Electric Sub Station/ generator room if provided should be on solid ground near DG/ LT. Control panel on ground floor or in upper basement and it should be located on outer periphery of the building, the same should be got approved from the Chief Electrical Inspector, Haryana.
(c) To ensure fire fighting scheme shall be got approved from the Director, Urban Local Bodies, Haryana or any person authorized by the Director, Urban Local
[143]
Bodies, Haryana. This approval shall be obtained prior to starting the construction work at site.
xviii. The rain water harvesting system shall be provided as per Code 8.1.
xix. That the owner shall ensure the installation of Light-Emitting Diode lamps (LED) for its building.
xx. That the owner shall strictly comply with the Code 8.3 for enforcement of the Energy Conservation Building Codes.
xxi. That the owner shall ensure the installation of Solar Power Plant as per Code 8.2. xxii. GENERAL
(a) Among other plans and papers detailed elevations of buildings along all sides exposed to public view shall be drawn according to scale as mentioned in the Haryana Building Code-2017.
(b) No applied decoration like inscription, crosses, names of persons or buildings are permitted on any external face of the building.
view each face of building but shall be suitably encased.
(d) The building design for the permissible covered area shall be submitted as a whole and not in parts.
(e) Garbage collection center of appropriate size shall be provided within the site.
(f) No advertisement shall be permitted.
4. Model Zoning Clauses for Storage/ Godown Building
i. Codereferred in the clause is Haryana Building Code, 2017, amended from time to time.
ii. SHAPE & SIZE OF SITE.
The shape and size of site is in accordance with the demarcation plan shown as ‘ ’ to ‘ ’, as confirmed by Competent Authority, vide drawing no…………….., issued on DD/MM/YYYY.
iii. LAND USE.
The site shall be used for Warehouse (For storage of non agro/ agro produce) in accordance with the permission of change of land use granted and its use for any other purpose shall not be permitted in any case.
Xvii. Fire Safety Measures:
(a) The owner will ensure the provision of proper fire safety measures in the multi storied buildings conforming to the provisions of The Haryana Building Code, 2017/ National Building Code of India and the same should be got certified form the Competent Authority.
(b) Electric Sub Station/ generator room if provided should be on solid ground near DG/ LT. Control panel on ground floor or in upper basement and it should be located on outer periphery of the building, the same should be got approved from the Chief Electrical Inspector, Haryana.
(c) The fire fighting scheme shall be got approved from the Director, Urban Local Bodies, Haryana or any person authorized by the Director, Urban Local Bodies, Haryana. This approval shall be obtained prior to starting the construction work at site.
xviii. The rain water harvesting system shall be provided as per Code 8.1.
xix. That the owner shall ensure the installation of Light-Emitting Diode lamps (LED) for its building.
xx. That the owner shall strictly comply with the Code 8.3 for enforcement of the Energy Conservation Building Codes.
xxi. That the owner shall ensure the installation of Solar Power Plant as per Code 8.2. xxii. GENERAL
(a) Among other plans and papers detailed elevations of buildings along all sides exposed to public view shall be drawn according to scale as mentioned in the Haryana Building Code-2017.
(b) The water storage tanks and other plumbing works etc. shall not be exposed to view each face of building but shall be suitably encased.
) No applied decoration like inscription, crosses, names of persons or buildings are permitted on any external face of the building.
The building design for the permissible covered area shall be submitted as a whole and not in parts.
(e) Garbage collection center of appropriate size shall be provided within the site.
5. Model Zoning Clauses for Group Housing
i. Codereferred in the clause is Haryana Building Code, 2017, amended from time to time.
Ii. Shape & Size of Site.
The shape and size of site is in accordance with the demarcation plan shown as ‘ ’ to ‘ ’, as confirmed by Competent Authority, vide drawing no…………….., issued on DD/MM/YYYY.
[146]
Iii. Type of Building Permitted and Land Use Zones.
(a) The type of building permitted on this site shall be buildings designated in the form of flatted development for residential purpose or any ancillary or appurtenant building including community facilities, public amenities and public utility as may be prescribed and approved by Competent Authority.
(b) The site shall be developed and building constructed thereon as indicated in and explained in the table below:
Notation
Land Use Zone
Type of Building permitted/permissible structure
Open Space Zone
Open parking, garden, landscaping features, underground services etc.
Building Zone
Building as per permissible land use in clause-iii above and uses permissible in the open space zone.
Iv. Site Coverage and Floor Area Ratio (FAR).
(a) The building or buildings shall be constructed only within the portion of the site marked as Building zone as explained above, and nowhere else.
(b) The proportion up to which the site can be covered with building or buildings on the ground floor and subsequent floors shall be as per Code 6.3(3)(i)(b).
(c) Maximum permissible FAR shall be as per Code 6.3(3)(i)(b).
vii. PARKING.
(a) Adequate parking spaces, covered, open or in the basement shall be provided for vehicles of users and occupiers, within the site as per Code 7.1.
(b) In no circumstance, the vehicle(s) belonging/ related to the plot/ premises shall be parked outside the plot area.
viii. APPROACH TO SITE.
(a) The vehicular approach to the site shall be planned and provided giving due consideration to the junctions of and the junctions with the surrounding roads to the satisfaction of the Competent Authority.
(b) The approach to the site shall be shown on the zoning plan.
(c) Entry and Exit shall be permitted as indicated/ marked on the plan.
Ix. BAR on Sub-division of Site.
Sub-division of the site shall not be permitted, in any circumstances.
[142]
X. Approval of Building Plans.
The building plans of the buildings to be constructed at site shall have to be got approved from the Competent Authority/ any other persons authorized by him, under the provisions of the respective Acts, before starting up the construction.
xi. BASEMENT.
Basements within the building zone of the site shall be provided as per Code 6.3(3)(iii) and shall be constructed, used and maintained as per Code 7.16.
Xii. Planning Norms.
The building to be constructed shall be planned and designed to the norms and standards as per Chapter-7 of the Haryana Building Code, 2017, and as approved by the Competent Authority.
Xiii. Provisions of Public Health Facilities.
The W.C. and urinals provided in the buildings shall conform to the National Building Code, 2005.
iv. TYPE OF BUILDING PERMITTED AND LAND USE ZONES.
(a) The type of buildings permitted on the site shall be buildings meant for Ware House purpose and their use for any other purposes shall not be permitted. The Building for ware house purposes shall include Ware House and ancillary uses. Ticketing Machine Room/ Cloak Room/Toilets/ Wireless Stations/ Canteen/ Security Rooms/ Generator Room will be allowed. Security Room, Ticketing Machine and Toilets may be allowed in the setback with the condition that whenever the land is required for widening of roads, the same can be acquired by the developing agency. These facilities may be provided at a distance of 9.00 metres from the main building.
(b) The site shall be developed and building constructed thereon as indicated in and explained in the table below:
Notation
Land Use Zone
Type of Building permitted/permissible structure
Open Space Zone
Open parking, garden, landscaping features, underground services etc.
Building Zone
Building as per permissible land use in clause-iii above and uses permissible in the open space zone.
[144]
(a) The building or buildings shall be constructed only within the portion of the site marked as Building zone as explained above, and nowhere else.
(b) The proportion up to which the site can be covered with building or buildings on the ground floor and subsequent floors shall be as per Code 6.3(3)(v).
(c) Maximum permissible FAR shall be as per Code 6.3(3)(v).
The height of the building block, subject of course to the provisions of the site coverage and FAR, shall be governed by the following:-
(a) The maximum height of the building shall not be more than 21 meters and shall not exceed 1.5 times (the width of the roads abutting) plus the front open space.
(b) If a building abuts on two or more streets of different widths, the buildings shall be deemed to face upon the street that has the greater width and the height of the buildings shall be regulated by the width of that street and may be continued to this height to a depth of 24 metres, along the narrow street.
(c) All building block(s) shall be constructed so as to maintain an inter-se distance as per Code 7.11(5).
(d) If such interior or exterior open space is intended to be used for the benefit of more than one building belonging to the same owner, then the width of such open air space shall be the one specified for the tallest building as specified in (c) above.
vii. SETBACK:
Setbacks shall be provided as per Code 6.3(3)(v).
viii. PARKING.
15% of the site area shall be reserved for idle parking. To avoid nuisance to the vehicular traffic, no idle parking will be made on the approach road. The segregated area of idle parking of trucks should be located by providing gate in a receded position vis-a-vis the plot boundary.
Ix. Approach to Site.
(a) The vehicular approach to the site shall be planned and provided giving due consideration to the junctions of and the junctions with the surrounding roads to the satisfaction of the Competent Authority.
(b) The approach to the site shall be shown on the zoning plan.
(c) Entry and Exit shall be permitted as indicated/ marked on the plan.
X. BAR on Sub-division of Site.
Sub-division of the site shall not be permitted, in any circumstances.
Xi. Approval of Building Plans.
The building plans of the buildings to be constructed at site shall have to be got approved from the Competent Authority/ any other persons authorized by him, under the provisions of the respective Acts, before starting up the construction.
xii. BASEMENT.
No basement permitted.
Xiii. Provisions of Public Health Facilities.
The W.C. and urinals provided in the buildings shall conform to the National Building Code, 2005.
Xiv. External Finishes.
[145]
(a) All sign boards and names shall be written on the spaces provided on buildings as per approved buildings plans specifically for this purpose and at no other places, whatsoever.
(b) For building services, plumbing services, construction practice, building material, foundation and Damp Proof Course Chapter 10 of the Haryana Building Code, 2017 shall be followed.
Xv. Lifts and Ramps:
(a) Lift and Ramps in building shall be provided as per Code 7.7.
Xvi. Building Bye-laws:
The construction of the building/ buildings shall be governed by provisions of the Haryana Building Code, 2017.
V. Height of Building.
The height of the building block, subject of course to the provisions of the site coverage and FAR, shall be governed by the following:-
(a) The maximum height of the building shall be as per Code 6.3(3)(i)(b).
(b) If a building abuts on two or more streets of different widths, the buildings shall be deemed to face upon the street that has the greater width and the height of the buildings shall be regulated by the width of that street and may be continued to this height to a depth of 24 metres, along the narrow street.
(c) All building block(s) shall be constructed so as to maintain an inter-se distance as per Code 7.11(5).
(d) If such interior or exterior open space is intended to be used for the benefit of more than one building belonging to the same owner, then the width of such open air space shall be the one specified for the tallest building as specified in (c) above.
vi. PARKING.
(a) The parking spaces in group housing shall be as per Code 7.1.
(b) In no circumstance, the vehicle(s) belonging/ related to the plot/ premises shall be parked outside the plot area.
Vii. Approach to Site.
(a) The vehicular approach to the site shall be planned and provided giving due consideration to the junctions of and the junctions with the surrounding roads to the satisfaction of the Competent Authority.
(b) The approach to the site shall be shown on the zoning plan.
(c) Entry and Exit shall be permitted as indicated/ marked on the plan.
Viii. Gate Post and Boundary Wall
(a) Such Boundary wall, railings or their combination, hedges or fences along with gates and gate posts shall be constructed as per design approved by
[147]
Competent Authority. In addition to the gate/ gates an additional wicket gate not exceeding 1.25 meters width may be allowed in the front and side boundary wall provided that no main gate or wicket gate shall be allowed to open on the sector road/public open space.
(b) The boundary wall shall be constructed as per Code 7.5.
ix. DENSITY
(a) The minimum density of the population provided in the colony shall be 100 PPA and the maximum be 300 PPA.
For computing the density, the occupancy per main dwelling unit shall be taken as five persons and for service dwelling unit two persons per room or one person per 7.5 square metres of living area, whichever is more.
X. Accommodation for Service Population
Adequate accommodation shall be provided for domestic servants and other service population of EWS. The number of such dwelling units for domestic servants shall not be less than 10% of the number of main dwelling units and the carpet area of such a unit if attached to the main units shall not be less than 13 square metres. In addition 15% of the total number of dwelling units having a minimum area of 20 square metres shall be earmarked for E.W.S category.
Xi. Open Spaces
While all the open spaces including those between the blocks and wings of buildings shall be developed, equipped and landscaped according to the plan approved by the Competent Authority. At least 15% of the total site area shall be developed as organized open space i.e. tot-lots and play ground.
Xii. Convenient Shopping
0.5% of the total site area shall be reserved to cater for essential convenient shopping with the following conditions:
(a) The ground coverage of 100% with FAR of 100 will be permissible. However this will be a part of the permissible ground coverage and FAR of the Group Housing Colony.
(b) The size and height of Kiosk/ Shops/ Departmental Store shall be as specified by the Competent Authority.
Xiii. Provision of Community Buildings
The community buildings shall be provided as per the composite norms in the Group Housing Colony.
Xiv. BAR on Sub-division of Site.
(a) The site of the Group Housing Colony shall be governed by the Haryana Apartment Ownership Act-1983 and Rules framed thereunder.
(b) Sub-division of the site shall not be permitted, in any circumstances.
Xv. Approval of Building Plans.
The building plans of the buildings to be constructed at site shall have to be got approved from the Competent Authority/ any other persons authorized by him, under the provisions of the respective Acts, before starting up the construction.
xvi. BASEMENT.
(a) The number of basement storeys in Group Housing shall be as per Code 6.3(3)(i)(b).
(b) The construction of basement shall be executed as per Code 7.16.
Xvii. Provisions of Public Health Facilities.
The W.C. and urinals provided in the buildings shall conform to the National Building Code, 2005.
[148]
xviii. EXTERNAL FINISHES.
(a) All sign boards and names shall be written on the spaces provided on buildings as per approved buildings plans specifically for this purpose and at no other places, whatsoever.
(b) For building services, plumbing services, construction practice, building material, foundation and Damp Proof Course Chapter 10 of the Haryana Building Code, 2017 shall be followed.
Xix. Lifts and Ramps:
Lift and Ramps in building shall be provided as per Code 7.7.
Xx. Building Bye-laws:
The construction of the building/ buildings shall be governed by provisions of the Haryana Building Code, 2017. On the points where such rules are silent and stipulate no condition or norm, the model building byelaw issued by the Indian Standards, and as given in the National Building Code of India shall be followed.
Xxi. Fire Safety Measures:
(a) The owner will ensure the provision of proper fire safety measures in the multi storied buildings conforming to the provisions of The Haryana Building Code, 2017/ National Building Code of India and the same should be got certified form the Competent Authority.
(b) Electric Sub Station/ generator room if provided should be on solid ground near DG/ LT. Control panel on ground floor or in upper basement and it should be located on outer periphery of the building, the same should be got approved from the Chief Electrical Inspector, Haryana.
(c) The fire fighting scheme shall be got approved from the Director, Urban Local Bodies, Haryana or any person authorized by the Director, Urban Local Bodies, Haryana. This approval shall be obtained prior to starting the construction work at site.
xxii. The rain water harvesting system shall be provided as per Code 8.1.
xxiii. That the owner shall ensure the installation of Light-Emitting Diode lamps (LED) for its building.
xxiv. That the owner shall strictly comply with the Code 8.3 for enforcement of the Energy Conservation Building Codes.
xxv. That the owner shall ensure the installation of Solar Power Plant as per Code 8.2. xxvi. GENERAL
(a) Among other plans and papers detailed elevations of buildings along all sides exposed to public view shall be drawn according to scale as mentioned in the Haryana Building Code-2017.
(b) The water storage tanks and other plumbing works etc. shall not be exposed to view each face of building but shall be suitably encased.
(c) No applied decoration like inscription, crosses, names of persons or buildings are permitted on any external face of the building.
(d) The building design for the permissible covered area shall be submitted as a whole and not in parts.
(e) Garbage collection center of appropriate size shall be provided within the site.
[149]
58[Model ZOning Clauses for Different Building Types
Model Zoning Clauses for Dormitory Plots in Licensed Industrial Plotted Colonies i. Code referred in the clause is Haryana Building Code, 2017, amended from time to time.
ii. SHAPE & SIZE OF SITE
The shape and size of site is in accordance with the demarcation plan shown as ‘ ’ to ‘ ’, as confirmed by Competent Authority, vide drawing no…………….., issued on DD/MM/YYYY.
iii. LAND USE
a) The type of building use permissible is residential and under no circumstance, the use of building shall be changed.
b) All such dormitory buildings shall be treated as public building for the purpose of requirement of Fire NOC for its construction and occupation.
iv. TYPE OF BUILDING PERMITTED AND LAND USE ZONES.
a) The type of buildings permitted on the site shall be buildings designated and intended to be use for residential purpose and there use for any other purposes shall not be permitted. It shall include dormitory office, common room, kitchen and dining area.
b) The site shall be developed and building constructed thereon as indicated in and explained in the table below:
Notation
Land Use Zone
Type of Building permitted/permissible structure
Open Space Zone
Open parking, garden, landscaping features, underground services etc.
Building Zone
Building as per permissible land use in clause-iii above and uses permissible in the open space zone.
v. AREA & DENSITY OF DORMITORY PLOTS
a) Minimum and Maximum Area of dormitory plots: 200-8000 sqm
b) Minimum and Maximum density permitted: 1000-1600 PPA
vi. SITE COVERAGE AND FLOOR AREA RATIO (FAR).
a) The building or buildings shall be constructed only within the portion of the site marked as Building zone as explained above, and nowhere else.
b) The Far and Ground coverage of such dormitory building of area upto 500 sqm shall be governed by the parameters as applicable for similar size residential plots in the Haryana Building Code.
c For dormitory plots greater than 500 sqm size, the following parameters shall be applicable:
(i) Maximum FAR allowed: 250
(ii) Maximum Ground Coverage: 50%
Vii. Norms Applicable for Dormitory Rooms
a) No dormitory room shall have an occupancy of less than four, i.e., no less than four beds shall be provided in a dormitory room. The calculation of occupancy of each dormitory room shall be based on the no. of beds proposed.
b) Bunk beds shall be allowed.
58 Inserted/amended vide Misc-2339-ULB-Vol-II-A/7/5/2006-2TCP dated 25.04.2022. This amendment shall come into force from 25.04.2022.
[150]
c) Min. & Max carpet area of dormitory room: 20 to 50 sqm.