Chapter 6Siting, Planning and Architectural Control Use of site, type and character of building.
(1) Type and character of building, including ancillary buildings, that may be erected or re-erected on a site and the purpose for which these may be used shall not be other than that shown in the Development Plan or the approved layout plan or sector plan or zoning plan.
(2) Where the site does not form part of such layout or sector plan or zoning plan, the use shall be in conformity with the use of the surrounding area, or use prescribed in development plan and the decision of the Competent Authority shall be final in this respect.
(3) Every building that may be erected or re-erected on a site shall, in addition to the foregoing restriction, comply with the restriction shown in the Architectural Control Sheets, wherever applicable, shall have precedence over the zoning plan or the building Code.
(4) Every building that may be erected or re-erected on site shall, in addition to other restrictions under this Code, comply with the provisions made in the National Building Code of India (amended from time to time), wherever this building Codeis silent.
Sub-division and amalgamation of plots
(1) Division of plot into smaller units is permissible in core areas with the prior approval of the Competent Authority. Each such plot shall be accessible separately and independently through a public road laid out and constructed to the satisfaction of the Competent Authority.
(2) 18[Except as otherwise expressly provided at the time of sale of a plot, not more than one building unit shall be erected on any one plot, but two or more plots may be amalgamated for purpose of erection of one “building unit”. In case of back to back plots which are to be amalgamated, two building units may be allowed maintaining the rear setbacks intact subject to the condition that a maximum of four dwelling units shall be permissible on the amalgamated plot.
Note:- “Building unit” means a self-contained building with such out buildings as are ordinarily ancillary to the main
18 Final amended substituted vide Misc-2339-(ULB)-VOL-II/7/5/2006-2TCP dated 06.11.2020.
[38]
building used in connection therewith and physically incapable of sub-division into two or more independent building units. A building unit may, however, be owned by an individual/ firm/ company or may be jointly and severally owned, provided it remains in a single indivisible ownership.]
(3) The Competent Authority shall be competent to refuse permission for construction on consideration of compact and economical development of the area till such time as availability of water supply, drainage arrangement, and other facilities are ensured to his satisfaction.
(4) In case plots which are to be amalgamated are back to back, then rear setback shall be maintained as per already approved zoning plan.
(5) In case plots adjacent plots are to be amalgamated, then setbacks shall be maintained as per zoning plan approved by the Competent Authority for whole amalgamated plot.
(6) Amalgamation of adjacent plots (side by side or back to back or both) where building stand constructed is permitted, subject to the condition that the constructed buildings shall not violate the provisions of zoning plan issued by the competent authority for the amalgamated plot.
(7) 19[The plots once amalgamated (either adjacent or back to back) may be allowed to be de-amalgamated subject to the condition that constructed buildings on these de-amalgamated plots shall conform to the approved zoning regulations of individual plots.]
6.3. Proportion of the site which may be covered with buildings.
(1) The proportions of covered area of a building, including ancillary buildings, shall be in accordance with the plot categories given in following sub-Codes and the remaining portion shall be left open in the form of open space around the building.
(2) Core Areas
(i) 20[Residential
Sr. no.
Plot area slabs
Maximum permissible Ground Coverage
Permissible basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height (G+3 Floor) (including stilt (S+4 Floor))
19 Final amended substituted vide Misc-2339-(ULB)-VOL-II/7/5/2006-2TCP dated 06.11.2020. 20 Inserted/amended by Misc-2339(ULB)-Vol-III/SD(DK)/2019/7/19/2019-2TCP dated 04.06.2019 and further amended on Misc-2339-VOL-III-ULB/7/5/2006-2TCP dated 20.10.2020.
[39]
(in metres)
1
Upto 60 square metres
85%
Single level
220 %
16.5
2
Above 60 to 150 square metres
80%
Single level
200 %
16.5
3
Above 150 to 225 square metres
70%
Single level
180%
16.5
4
Above 225 to 450 square metres
60%
Single level
160 %
16.5
5
Above 450 square metres
50%
Single level
140 %
16.5]
(ii) Commercial
Sr. no.
Plot area slabs
Maximum permissible Ground Coverage
Permissible basement
Maximum permissible Floor Area Ratio (FAR)
Maximum permissible Height
1
upto 50 square metres
100%
Single level
200 %
Unrestricted
2
Above 50 to 150 square metres
85%
Single level
200 %
Unrestricted
3
Above 150 to 225 square metres
75 %
Single level
200 %
Unrestricted
4
Above 225 to 450 square metres
60 %
Single level
175 %
Unrestricted
5
Above 450 to 1000 square metres
40%
Single level
175 %
Unrestricted
Note: Example for calculating FAR and ground coverage as per plot area slabs for 14 marla and 1 Kanal plot:
Calculations for Ground Coverage
Plot area slabs
Area in each slab (in square metres)
Maximum permissible Ground Coverage
14 marla plot (354.1 square metres)
1 Kanal plot(505.86square metres)
Upto 75
75
66
49.5
49.5
76-100
24
66
15.84
15.84
101-150
49
60
29.4
29.4
151-250
99
60
59.4
59.4
251-350
99
50
49.5
49.5
351-500
149
50
4.05
74.5
[40]
501-1000
499
45
4.8861
207.69
283.0261
Actual permissible ground coverage
58.6529229
Calcul
ations for Floor Area R
atio (FAR)
Plot
Area in each
1
area
slab (in square
Maximum
Kanal(505.
slabs
metres)
permissible Floor Area Ratio (FAR)
14 marla(354.1 square metres)
86 square metres)
Upto 75
75
165
123.75
123.75
76-100
24
165
39.6
39.6
101-150
49
145
71.05
71.05
151-250
99
145
143.55
143.55
251-350
99
125
123.75
123.75
351-500
149
120
9.72
178.8
501-1000
499
100Actual permissible FAR
511.42144.4281276
10.858691.358136.6703699
(iii) Plot setbacks (core areas)
The buildings shall not project beyond the building lines as shown in the zoning plan of respective schemes. However, in case where zoning plans are not prepared, the minimum setbacks shall be provided as below:-
Sr. No.
Area of plot (in square metres)
Minimum Front Setback (in metres)
Minimum Rear Setback (in metres)
1.
Upto 60 square metres
0.5
0.5
2.
Above 60 to 150 square metres
1.5
1.0
3.
Above 150 to 225 square metres
2.5
2.0
4.
Above 225 to 450 square metres
3.0
3.0
[41]
5.
Above 450 square metres
4.5
4.0
(a) The front setbacks can be adjusted to achieve permissible Ground Coverage subject to the condition that rear setbacks are fixed.
(b) In core areas single level basement may be allowedupto the maximum roof height of not more than 1.5 metres from the ground level for the area of maximum permissible coverage and after that till the zoned area, the roof of basement shall flush with the ground level.