(1) Minimumarea for a habitable room, kitchen and water closet shall be followed in accordance to tablet given as under:
| Sr. no. | Room type | Minimum area (in square metres | Size (minimum width) (in metres) | Minimum Height (in metres) | Light and Ventilation (area of open-able windows, ventilators) |
| 1 | Habitable room | 9.5 | 2.4 | 2.75 | Total area not less than 1/8th of the total floor area of the room. |
| 2 | Kitchen | 5.5 | 1.8 | 2.75 (except for the portion accommodate floor trap of above floor) | Total area not less than 1/8th of the total floor area of the room. |
| 3 | Pantry | 3.00 | 1.40 | 2.75 | Not applicable |
| 4 | Bathroom | 1.80 | 1.20 | 2.45 | |
| 5 | Water Closet | 1.1 | 0.90 | 2.45 | |
| 6 | Combined Bath and Water Closet | 2.8 | 1.2 | 2.45 | 0.3 square metres on wall not less than 0.3 metres wide. |
| 7 | Store | No restriction | No restriction | 2.10 | Not applicable |
| 10 | Garage | 14.85 | 2.75 x 5.40 | 2.40 | |
| 11 | Doorways Habitable room | Not applicable | 0.90 | 2.10 | |
| 12 | Doorways for kitchen, bath, W.C | Not applicable | 0.75 | 2.00 |
37 Inserted/amended by Misc-138A-Loose/7/5/2006-2TCP dated 22.12.2017
[58]
(2) Habitable room
(i) In case of Group Housing Scheme the dwelling unit having more than one room may have one of the rooms with a clear floor area not less than 7.5 sq. metres with one side not less than 2.4 metres.
(ii) In case of air conditioned rooms, the height shall not be less than 2.4 metres measured from the surface of the floor to the lowest point of air conditioning duct or false ceiling; and
(iii) All doors and windows shall open directly or through a verandah or to a permanent open space or an open space abutting the building not less than 1.8 metres in width. No portion of a room shall be assumed to be lighted, if it is more than 3 metres or as stated in National Building Code 2005, away from the opening provided for lighting that portion.
(iv) 38[The carpet area of any ‘Store’ or ‘Utility Room’ to be provided in any residential building shall not be more than or equal to the minimum area requirement of a habitable room, i.e. 9.5 sqm;
(v) The dining room, drawing room and dining-cum-drawing room shall be considered as a habitable room;
(vi) The provision of lobby exceeding the size of habitable room, i.e. 9.5 sqm in a residential building shall be allowed subject to prior provision of either a drawing room or dining-cum-drawing room.]
(3) Kitchen
(i) In case there is a separate store, the floor area of the kitchen shall be reduced to 4.5 square metres.
(ii) In case of houses constructed on plots up to 100 square metres, the size of the kitchen shall be reduced to 3.8 square metres.
(iii) The kitchen which is intended for use as a dining space also shall have a floor area of not less than 9.5 square metres with a minimum width of 2.45 metres.
(iv) For the purpose of this regulation, a kitchen shall be deemed to be a habitable room and all the aforementioned requirements regarding ventilation shall apply to it
38 Inserted/amended vide Misc-2339-ULB-Vol-II-A/7/5/2006-2TCP dated 25.04.2022. This amendment shall come into force from 25.04.2022.
[59]
provided that the minimum area of the kitchen shall not be less than 5.5 square metres with a minimum width of 1.8 metres.
(v) In case of Group Housing Scheme the minimum area of the kitchen shall not be less than 5.5 square metres with a minimum width of 1.8 metres.
(4) Bathroomand Water Closet (W.C):
(i) Every bathroom and water closet shall:-
(a) preferably be so situated that at least one of its walls shall have opening for circulation of external air, with provision of exhaust fan.
(b) not be directly over any room other than another W.C, washing place, bath or terrace unless it has a watertight floor (only in case of toilet fixtures affixed at sunken slab);
(c) have a platform or seat made of water tight non-absorbent materials;
(d) preferably be enclosed by walls and partitions and the surface of every such walls or partition, shall be finished with a smooth impervious material to a height not less than 1.5 metres above the floor of such room; and
(e) beprovided with impervious floor covering sloping towards the drain with a suitable gradient and not towards verandah or any other room.
(ii) Where the water-closet room in a building is not connected to exterior, it shall be ventilated by mechanical means or through a vertical shaft open to sky of a minimum size stated at Code 7.11(6) for ventilation to toilet, bath and water closet, but it shall be counted towards covered area.
(iii) No room containing water-closet shall be used for any other purposes except as lavatory and no such room shall open directly into any kitchen or cooking space by a door/ window or another opening. Every room containing watercloset shall have a door completely closing the entrance to it.
(iv) Soil or ventilating pipes shall not be allowed on the exterior face of any building, provided these shall either be embedded in the walls or pipe ducts to be provided to accommodate them.
[60]
(v) Security rooms each measuring maximum area of 3.0 square metres is permitted only at the entry and exit gates of premises.
Boundary Wall, Fence, Gate and Porch
(1) The location of gate/ gates shall be as per zoning plan.
(2) Maximum permissible height of front side boundary wall shall be not more than 1.2 metres from the mean level of abutting street in front of the plot from where entry to the plot has been taken.
Note: The owner/ applicant if desires, is permitted to not construct boundary wall in front of plot, so that the said area can be utilized for parking.
(3) Maximum height of boundary wall at rear and side of plot shall not be more than 1.8 metres from the mean level of abutting street in front of the plot from where entry to the plot has been taken.
Note: In case of plots above 2000 square metres, maximum height of boundary wall at the rear and side of plot shall not be more than 1.8 metres from the abutting ground level.
(4) A railing/ grill with or without poly carbonate/ fibre glass sheet covering of 0.75 metre height shall be permitted over and above the maximum height of boundary wall at all sides.
(5) The temporary porches of polycarbonate sheets/ fibre glass roof or any other temporary material covering on suitable structure, shall be allowed in residential plots with the condition that these shall be open on sides in the driveway area within the plot.
(6) The provisions of above Code 7.5(2), (3), (4) and (5) are not applicable to boundary walls of jails.
(7) Boundary wall upto the height of 2.4 metres may be permitted by the Competent Authority in industrial buildings, electric substations, transformer stations, institutional buildings like hospitals, industrial buildings like workshops, factories and educational buildings like schools, colleges, including hostels and other uses of public utility undertakings and strategically sensitive buildings.