(i) Residential
(a) 21[Plotted
| Sr. no. | Plot area slabs | Maximum permissible Ground Coverage | Permissible Basement | Maximum permissibl e Floor Area Ratio (FAR) | Maximum permissible Height (G+3 Floor) (including stilt (S+4 Floor)) (in metres) |
|---|---|---|---|---|---|
| 1 | Upto 100 square metres | 75% | Single level | 165 % | 16.5 |
| 2 | Above 100 to 250 square metres | 75% | Single level | 145 % | 16.5 |
| 3 | Above 250 to 350 square metres | 66% | Single level | 130 % | 16.5 |
| 4 | Above 350 to 500 square metres | 66 % | Single level | 120 % | 16.5 |
| 5 | Above 500 to 1000 square metres | 66 % | Single level | 100 % | 16.5] |
Note:-
I. The additional FAR is allowed on payment of charges as approved by Government from time to time.
II. Provided that the building shall conform to the restriction contained in the zoning plans or the architectural control sheets of respective area of sector.
III. Provided further that in case of sites measuring 100 square metres or less under any scheme relating to
21 Inserted/amended vide Misc-2339-ULB-Vol-II-A/7/5/2006-2TCP dated 25.04.2022. This amendment shall come into force from 25.04.2022.
[42]
houses for economically weaker section framed by the Government, Housing Board, Improvement Trust or any other authority, the Competent Authority may relax the above condition.
IV. Provided further that the 25% of the built up area of the building or upto 50 square metres, whichever is less, can be used for non-nuisance professional consultancy services, after getting permission from Competent Authority in writing. The applicant shall apply for specific use of consultancy services as mentioned in Code 1.2(1)(lx) in Form N-I along with fee as mentioned in Schedule IV-A. The permission shall be granted in Form N-II”.
V. The stilts are permitted for parking purposes in residential and commercial plots of all sizes, subject to the condition that maximum permissible height of building shall not exceed 15 metres.
VI. 22[Any violation of the permissible ground coverage limit as indicated in the table above shall be non compoundable.
VII. Plot setbacks (areas other than core areas)
| Sr. No | Area of Plot (in square metres) | Minium Front Setback (In meters) | Minimum Rear Setback (in meters) |
|---|---|---|---|
| 1. | Upto 75 square metres | 1.0 | 1.5 |
| 2. | Above 75upto 150 square metres | 1.5 | 2.0 |
| 3. | Above 150 upto 250 square metres | 2.0 | 2.0 |
| 4. | Above 250 square metres | 3.0 | 3.0 |
Note: No Balcony beyond the rear zoning shall be permitted]
(b) Group Housing
| Sr. No. | Maximum permissible ground coverage | Permissible Basement | Floor Area Ratio | Maximum Permissible height |
|---|---|---|---|---|
| 1. | 35% | Upto four levels | 175% | Unrestricted |
22 Inserted/amended vide Misc-2339-ULB-Vol-II-A/7/5/2006-2TCP dated 25.04.2022. This amendment shall come into force from 25.04.2022.
[43]
Note:
I. The height of mumti/ lift room/ water tank/Building Maintenance Unit shall be exclusive of building height;
II. The parking requirement of group housing shall be governed by Code 7.1 or any other policy issued by the Government in this regard, from time to time.
III. 23[The siting and planning norms for Group Housing in Transit Oriented Development Zone (as defined in clause xciii-b of Code 1.2) shall be governed by clause 1 of Annexure D and policy notified on 09.02.2016, as amended from time to time.
IV. The siting and planning norms for Affordable Group Housing (as defined in clause ii-a of Code 1.2) shall be governed by clause 2 of Annexure D and policy notified on 19.08.2013, as amended from time to time.]
(ii) 24[Commercial
| Sr. no. | Type of building | Area norm | Maximum permissible Ground Coverage | Permissible Basement | Maximum permissible Floor Area Ratio (FAR) | Maximum permissible Height |
| 1 | Shop-cum-Flat (SCF) or Shop-cum-Office (SCO) or Shop-cum-Office-cum-Flat (SCOF) or Double Storey Shop (DSS) purposes or for shopping booths | Unrestricted | As per the Architectural Control Sheets | |||
| 2 | Commercial colony: includes shopping mall, multiplex, Departmental store, | Unrestricted | 60 % | Unrestricted | 175 % | Unrestricted |
23 Inserted/amended vide Misc-2339-ULB-C/7/5/2006-2TCP dated 18.10.2022.
24 Inserted/amended vide Misc-2339-ULB-Vol-II-A/7/5/2006-2TCP dated 25.04.2022. This amendment shall come into force from 25.04.2022.
[44]
| Integrated commercial Complex, Service Apartment, starred Hotel/ Unstarred Hotel, offices. | ||||||
| 3 | Dhabas | 1000 square metres to 1 acres | 40 % | Unrestricted | 40 %(maximum 50 sqm for kiosks like STD, Books, Cassettes, CDs etc.) | 5 metres |
| 4 | Banquet Hall | Minimum 2.5 acres | 50 % | Unrestricted | 50%(10% FAR allowed for gift shop/STD Booths, Toy Centre and flower shops etc.) | Unrestricted |
| 5 | Starred Hotels, Restaurants | Unrestricted | 40 % | Unrestricted | 175 %(with permissible15%commercial component) | Unrestricted |
| 6 | Restaurants | Minimum area 1000 square metres | 60% | Unrestricted | 175 %(with permissible10%commercial component) | Unrestricted |
| 7 | Amusement Park | Unrestricted | 30 % | Unrestricted | 50 %(with permissible15%commercial component) | Unrestricted |
| 7 | Resort, Motel (with/ without banquet hall facilities) | Unrestricted | 30% | Unrestricted | 175 % | Unrestricted |
| 8 | Big box retail stores | Unrestricted | 60% | Unrestricted | 175% | Unrestricted |
| 9 | Petrol Stations | Unrestricted | As per terms and conditions of Oil companies. | |||
25[Note:The siting and planning norms for Integrated Commercial Complex (as defined in the Act No. 8 of 1975) in Transit Oriented
25 Inserted/amended vide Misc-2339-ULB-C/7/5/2006-2TCP dated 18.10.2022.
[45]
Development Zone (as defined in clause xciii-b of Code 1.2) shall be governed by clause 1 of Annexure D and policy notified on 09.02.2016, as amended from time to time.]
(iii) 26[Institutional and Educational
| Plot area slabs | Maximum permissible Ground Coverage | Permissible Basement | Maximum permissible Floor Area Ratio (FAR) | Maximum permissible Height |
|---|---|---|---|---|
| For all plot sizes | 35 % | Upto four levels | 150% | Unrestricted |
| Nurshing Home and Clinic Sites | 50% | Single level | 150 % | Unrestricted |
Note:
I. In case of educational institutes (College/ University/ Schools), the Hostel component is restricted to 20% of maximum permissible covered area, and
II. The residential component (i.e. residential facility for principal, teachers/ professors, staff, etc.) is restricted to 10% of maximum permissible covered area (separate from hostel component).
However, the Competent Authority after considering the requirement of the project can permit residential component above the stated percentage by recording the reasons, subject to maximum limit of 50% of FAR.
(iv) 27[Industrial and IT
| Sr. No. | Type of Industry | Maximum Ground Coverage | Permissible Basement | Maximum Permissible Floor Area Ratio | Maximum Permissible Height | Remar ks |
| 1. | General | 60% | Twin level | 150 % | 30 Metres | -- |
| 2. | Apparel and Footwear | 60% | Unrestricted | 250 % | Unrestricted | To be located on roads with a Right Of Way of 15 metres and |
| 3. | Biotechnolo gy other than Pharmaceuti cals | 40% | ||||
| 4. | Information Technology/Information |
26 Inserted/amended vide Misc-2339-ULB-Vol-II-A/7/5/2006-2TCP dated 25.04.2022. This amendment shall come into force from 25.04.2022.
27 Substituted vide memo no. Misc-2339-Vol-III-ULB/7/5/2006-2TCP dated 25.04.2022.
[46]
| Technology Enable Services | above. | |||||
|---|---|---|---|---|---|---|
| 5. | Information Technology Park, Cyber Park, Cyber City, Technology Park | 40% | Unrestricted | 250 % | Unrestricted | Subject to conditi on that the plot must be located on roads with a Right Of Way of 30 metres and above. |
| 6. | Date Centre Industry | 60% | Unrestricted | 500% | Unrestricted There will be no restriction on floor to ceiling height subject to there being no mezzanine floor and compliance with structural and fire safety regulations.] |
Note for above Code 6.3(3)(ii), (iii) and (iv):
a. Unrestricted basement means as many numbers of basements subject to fulfilment of parking norms and/ or storage requirements and/ or use of maximum permissible FAR (in case of habitable use of basement) required in accordance to use of building.
b. Four levels basement shall be allowed only on site having area more than 8000 square metres & in other cases as decided by Competent Authority.
c. The facility of enhanced FAR beyond the General level of 125%in industrial use shall be permissible on payment of proportionate charges/ infrastructure strengthening charges as prescribed by the Government/ Development Agency.
d. The facility of enhanced FAR of 25% beyond the General level of 150% in resorts, five star hotels, motels
[47]
(with/without banquet hall facilities) shall be permissible on payment of proportionate charges/ infrastructure strengthening charges as prescribed by the Government/ Development Agency.
e. 28 The facility of enhanced FAR of 50% beyond the general level of 100% in institutional and educational use shall be permissible subject to payment of proportionate increasing EDC & conversion charges at existing rates (in the form of augmentation charges) for the existing buildings i.e. Building Plans are approved before 30.06.2016. However, no such payment is required for such buildings whose building plans are approved by competent authority after 30.06.2016.
f. 29 [The following norms shall be applicable for Data Centres:-
(i) Parking area will be as per requirement and will be provided in open area. The Data Centres shall also provide additional parking, if needed due to increase in traffic.
(ii) Multi-level DG stacking upto G+4 structure shall be allowed subject to NOC from Fire Department and shall not be considered as part of FAR.
(iii) Chillers on the roof can be installed subject to structural safety and clearance from competent authorities/ Fire Department/ Airports Authority of India.
(iv)Boundary wall upto height 3.6m, with further 1m height for ‘Y’ fencing shall be permitted.
(v) Minimum number of windows subject to compliance with building and fire safety regulations and having modern fire-fighting equipments installed within the premises.]
(v) Ware house/ Storage/ Godown
| Sr. no. | Type of building | Maximum permissible Ground coverage | Maximum permissible Floor Area Ratio (FAR) | Setbacks all around the plot (in metres) |
|---|
28 Substituted vide Misc-2339-(ULB)-Vol-II /7/5/2006-2TCP dated 10.09.2019.
29 Inserted/amended vide Misc-2339-ULB-Vol-II-A/7/5/2006-2TCP dated 25.04.2022. This amendment shall come into force from 25.04.2022.
[48]
| 1 | Integrated Inland Container Depots/ Custom Bounded Areas | 60% | 75 % | 15 |
| 2 | Warehouse other than agricultural produces/ Grain Godowns/ Silos | 9 | ||
| 3 | Warehouse For Agricultural Produces/ Grain Godowns/ Silos | 6 | ||
| 4 | Gas Go-down | As per zoning plan |
Note:
If a warehouse contains storage of agro produce and also products other than agriculture produce, then the setbacks of 9 metres shall be followed.