Municipal Corporation/ Municipal Council/ Nagar Panchayat.
To
................
................
(Name and address of the applicant)
Subject: Issue of sanction / provisional sanction of erection/ re-erection/ addition / or alteration of the building and issue of Building permit under rule 20(I).
Building Particulars : premises No. and Street ....Ward No.____
Sir,
With reference to your application dated the .... for the sanction / provisional sanction .... erection / re-erection / addition / to / alteration of , the building on Plot No .... street .... Ward No .... this building permit to hereby granted subject to the following conditions, namely :
The Building permit is valid up to the day of month (year)
The Building permit No .... dated the .... is
valid for occupancy of the use group (Residential / commercial /Public Building /Other- Specify)
The Building / work, for which this Building permit is issued shall be completed within
The construction will be undertaken as per sanctioned plan only and no deviation from the Building Rules, under Tripura Municipal Act, 1994 will be permitted. Any deviation done against the said rules is liable to be demolished.
One set of the plan and specifications submitted along with the notice duly countersigned is returned herewith.
Yours faithfully,
Office No....
Office Stamp ....
Dated the ....
Mayor/Chairperson
(Signature and designation of the officer to whom power have been delegated)
Instructions to the Applicant
The applicant must be owner of the land.
Before filling up the form please go through the provisions of the Building Rules.
The applicant is requested not to take up the building construction until and unless he is permitted to do so. If any such construction is undertaken without permission, it will be treated, as clear violation of the Building Rules and matter will be proceeded with accordingly.
The building shall not be considered within the restricted distance of the electric wire running on any side of the side under the provisions of the Indian Electricity Rules.
The building plan must be prepared by the Architect / Licensed Building Planner and the list of approved Building Planners available in the office.
If any information or document is required under the Building Rules or is, in the opinion of the competent authority, incomplete, he may require further information or documents to be furnished.
If the Land Use controller, if any, refused to issue "No objection Certificate", in that case the competent authority will not accord any sanction of Building Plan as per this rules.
In case of fees in respect of grant of permission to execute any work it would be determined as per Rule 25. The said fees to be paid in the form of Account Payee Demand Draft on any Schedule Bank of the area in favour of ____ along with duly filled in application Form B and other enclosures.
Applicant shall submit the application Form B as the case may be (in duplicate) duly filled in, for permission to construct or re-construct masonry building and shall enclose the following documents with the application, otherwise it will be rejected :-
(a) An approved site plan.
(b) A building plan in triplicate.
(c) Filled up Form B as the case may be, in duplicate
(d) Filled up Annexure of Form B (in duplicate).
(e) Attested copy / certified copy of allotment of land and possession certificate of land.
(f) Attested copy of current holding tax receipt in case of old building / new building for execution purpose.
(g) Account payee Demand Draft of Rs. ____ as Fees for sanction of Building Plan.
Annexure 1(Statement of particulars and specification)
Name in full(in block letters) of the owner :
Present Address ____
P.S. ____ Mouza ____ J.L. ____
C.S. Rehab/Plot No. of the site ____ Ward No. ____
The purpose (Residence, Office, Godown, Restaurant, Hotel, Dharmasala, School, College, Hostel, institution, Cinema, Shop, Factory, etc.) for which it is intended to be used
(a) Basement____
(b) Ground floor ____
(c) 1st floor ____
(d) 2nd floor ____
(e) 3rd floor ____
(a) Total area of the site (in square meters) ____
(b) Total plinth area of the building proposed to be erected/re-erected etc. (in square meters)
(c) Site Plan Sanction No (with date) ____
(a) Number of floors ____
(b) Height of the building over road level____
The materials to be used as specification of the constructions:
(a) Foundation
(b) Floors
(C) Walls
(d) Roofs
(e) Fire Places/chimneys
(a) Approximate number of inhabitants proposed to be accommodated: -
(b) The number, size and specification of latrine, kitchen, bath to be provided
Probable cost of construction of the proposed structure____(and such other information as required by the rules)
Signature of the Architect /Licensed Building Planner.
License No. ____ Date ____
Full Address ____
Signature, name and address of the owner.
____________________
Form NO - B-A (Rule No. 15) Certificate of Undertaking for Hazard Safety (regulation NO. ---) Requirement
To,
REF: Proposed work of ____
(Title of project)
Location:
____
Rule No. ---- of Tripura Building Rules
Certified that the building plans submitted for approval of the safety requirements as stipulated under the information given therein is factually correct to the best of our knowledge and understanding.
It is also certified that the structural design including safety from hazards based on soil conditions, shall be duly incorporated in the design of the building and these provisions shall be adhered to during the construction.
A check list is attached.
Signature of Owner with date ____
Signature of the Structural Engineer
with date____
Name in Block letters ____
Name in Block letters ____
Address ____
Address ____
Signature of the Developer
with date____
Signature of the Architect
with date____
Name in Block letters ____
Name in Block letters ____
Address ____
Address ____
Building information schedule
1 Encircle the applicable data point 2 * means 'any other, specify'
1 Building address
Plot No.
Scheme / Colony:
Town:
District:
2 Building category
2.1 Occupancy Classification
a
b
c
d
e
f
g
h
i
NBC7.1.1
2.2 Type of Construction
Type 1
Type 2
Type 3
Type 4
NBC & 1.2 OF Part III & 4 of Part IV
3 Location
3.1 Land use zoning
Bye law
3.2 Seismic zone
V
IV
III
II
Is 1893-2000
Design intensity(MM/MSK)
IX
VIII
VII
VI
Vul. Atlas
3.3 Wind /Cyclone zone
Wind speed + 55/50/47/44/39/33
Cyclone prone Yes/No
Max. storm surge = m
Vul. Atlas
3.4 Flood proneness of site
River plain Unprotected/ Protected
Low area inundation possible - Yes / No
Observed HFL about GL = cm
Vul. Atlas
3.5 Prone to land slides
4 Foundation
4.1 Site and sub-soil investigation
IS 1892, IS 5249
4 Foundation
4.2 Soil type at site (Note 2)
Rocky/ Stiff
Medium
Soft
Liquefiable
Expansive (Black cotton)
*
IS 1904, IS 6403
4 Foundation
Stiff- N>30; Medium- N=10 -30 ; Soft- N<10; Liquefiable - Poorly graded sands with N<15, under water table (see Note 5 of Table 1 in IS 1893)
Stiff- N>30; Medium- N=10 -30 ; Soft- N<10; Liquefiable - Poorly graded sands with N<15, under water table (see Note 5 of Table 1 in IS 1893)
Stiff- N>30; Medium- N=10 -30 ; Soft- N<10; Liquefiable - Poorly graded sands with N<15, under water table (see Note 5 of Table 1 in IS 1893)
Stiff- N>30; Medium- N=10 -30 ; Soft- N<10; Liquefiable - Poorly graded sands with N<15, under water table (see Note 5 of Table 1 in IS 1893)
Stiff- N>30; Medium- N=10 -30 ; Soft- N<10; Liquefiable - Poorly graded sands with N<15, under water table (see Note 5 of Table 1 in IS 1893)
Stiff- N>30; Medium- N=10 -30 ; Soft- N<10; Liquefiable - Poorly graded sands with N<15, under water table (see Note 5 of Table 1 in IS 1893)
Stiff- N>30; Medium- N=10 -30 ; Soft- N<10; Liquefiable - Poorly graded sands with N<15, under water table (see Note 5 of Table 1 in IS 1893)
4.3 Depth of water table below GL
4.4 Bearing capacity at site (used in design)
For normal loads = t/m²
With EQ = t/m²
With EQ = t/m²
With wind = t/m²
With wind = t/m²
With flood = t/m²
IS 1888, IS 1904 IS 6403 IS 8099 (Part 1 & 2)
4.5 Type of footing / Foundation used
Strip
Individual column footing/Raft
Bearing piles
Bearing piles
Friction piles
Friction piles
*
5 Super structure
5.1 Storeys etc
Basements 0/1/2/3
No. of storeys
Attic Yes/ No
Lift house Yes/ No
Water tank on roof Capacity 1
5.2 Bearing walls
Brick
Stone
Solid block
Hollow block
Adobe
*
5.2.1 Mortar
C:S=1:
C:L:S=1: :
L:S=1:
Clay Mud
*
C=Cement S=Sand L=Lime
5.3 Framework
RC columns & beams
Steel columns & beams / trusses
Wood posts & trusses
*
5.3.1 Infill panels
Glass
Brick walls
Wood paneling
*
5.4 Floors
RC slabs
Stone slabs on jists
Prefab floring elements on breams
*
5.5 Roof
Flat like floors/Pitched
Trussed / Raftered/ 'A' frame/Sloping RC slab
*
5.6 Roof covering
CGI sheeting
AC sheeting
Clay tiles
Wood shingle
*
6 Building importance
6.1Importance
Ordinary
Important
Hazardous
IS 1893
7 Design factors
7.1 Factor for EQ
α₀ =
I =
β =
αh =
IS 1893
7.2 Factor for wind
K₁ =
K₂ =
K₃ =
Ph =
Is 875 (Pt3)
8 Flood protection
Plinth protection Yes/ No / NA
Water proofing of walls Yes/ No/ NA
Roof Yes / No / NA
*
Flood guide
9 Safety of pitched roof where used
9.1 Bracing provided
In plan Yes / No /NA
In plane of rafters Yes/No/ NA
In plane of vertical columns Yes/No/NA
IS 4326 Cyclone guide
9.2 Roof anchorage
To walls: Bolt length = cm
To RC columns: Bolt length = cm
To wooden posts, steel straps & bolts / nails...
Cyclone guide
9.3 Connections
Covering to purlins J-bolt/ire
Purlins to rafters Bolt/ Wire
Truss elements Welding/Bolts/Nails/Straps
Cyclone guide
10Loadbearing wallbuilding
10.1Building
A αh < 0.05
B αh=0.05 to 0.06
C αh>0.06 &<0.08
D αh=0.08 to < 0.12
E αh>0.12
IS 4326IS13828
10.2Building configuration
Plan shapeL/T/Y/C/E
Separation provided to get rect.Blocks Yes / No
Plan projection>0.2 of lengthYes / No
IS 4326
10.3Opening in walls
Control used on sizesYes / No / NA
Control used on locationYes / No / NA
Strengthening aroundYes / No / NA
IS 4326, IS 13828
10.4Bands provided
Plinth bandYes/No/NA
Lintel BandYes/No/NA
Eave bandYes/No/NA
Roof bandYes/No/NA
Gable bandYes/No/NA
Ridge bandYes/No/ NA
IS 4326, IS 13828
10.5Vertical bars
At corner of roomsYes/No/NA
At jambs of openingYes/No/NA
*
IS 4326, IS 13828Cyclone guide
10.6Stiffening of floors / roof with separate units
RC screed & bandYes/No/NA
Peripheral band and connectorsYes/No/NA
Diagonal planks and alround bandYes/No/NA
*
IS 4326
10.7 Framed thin wall construction
Bonding of columns with the wall ensured Yes / No (Fig. 13 of IS 4326)
IS 4326
11Safety ofwoodenbuildings
11.1 Holdingdown
Sill beamboltedYes/No/NA
Wood postsanchoredYes/No/NA
Framed, restingon pedestalsYes/No/NA
IS4326Cycloneguide
11.2 Bracing ofwood frame
Diagonalbracing inVerticalplanesYes/No/NA
Diagonal /kneebracing inplanYes/No/NA
Stiff wallpanel
Bricknogginwithholdfasts
IS 4326Cycloneguide
11.3Connections
Framedwith ironstrips
Bolted
Nailed
*
Cycloneguide
12Safety of steel / RCframe buildings
12.1Building shape
Both axes symmetrical
One axis symmetrical
Unsymmetrical in plan or section
12.2Analysis used
Equivalent static
Model
Dynamic
Torsional effects considered Yes / No
IS 1893
12.3Method of design used
Work stress
Limit state
Plastic theory
IS 456IS 800SP 6(6)
12.4 Infills / partitions
Out of plane stability check Yes/ No
In-plane stiffness considered Yes/No
IS 1893IS 4326Cyclone guide
12.5Detailing of RC frames
Beams Yes / No
Columns Yes/No
Beam-column joint Yes / No
Shear wall Yes / No
IS 13920
12.6Detailing of steel frames
Beams Yes / No
Columns Yes/No
Beam-column joint Yes / No
SP 6
13 Fire safety
13.1 Provision for water
Under ground tank : Provided/Not provided Capacity: 1
Over head tank : Provided / Not provided Capacity: 1
Adequate pumping system: Provided/ Not provided Capacity : 1/minute Pressure:
NBC Part IV
13.2 Provision for first aid fire fighting
Provided / Not provided / Not applicable
NBC Part IV
13.3 Installation of systems
Provided / Not provided / Not applicable
NBC Part IV
14 Electrical safety
14.1 Earthing design and provision
Designed / Not designed
Provided / Not provided
IS 3043
14.2 Electrical lay out/provision
Designed : Yes / No
IS 4648IS 732
15 Land slides
15.2 Land slide control
Designed : Yes / No
IS 14680
15.3 Design and construction of retaining walls
Designed : Yes / No
IS 14458 Part 1,2,3
FORM C
Form D (See Rule 20 (1) (b) Form of Communication of Refusal of Sanction
From: The Mayor/Chairperson
Dated ____ Office Ref. No. and date if any
Municipal Corporation/ Municipal Council/ Nagar Panchayat.
To
(Name and address of the applicant)
Subject: Communication of refusal of sanction under rule 20 (1) (b).
Building Particulars : Premises No. and Street .....
.....
Ward No ....
With reference to your application dated the .... for the sanction / provisional sanction for .... erection / re-erection / addition to / alteration of , the building on plot ....
(number, street address, Ward No.) the sanction / provisional sanction has been refused under rule 20 of the Building Rules, under Tripura Municipal Act, 1994.
The ground / grounds on which the sanction has been refused is / are as follows :
Office No....
Yours faithfully,
Office Stamp ....
Dated the ......
Mayor/Chairperson
(Signature and designation of the officer
to whom power have been delegated)
FORM G (contd.) (See Rule 33) FORM OF NOTICE OF COMPLETION
From :................
Dated ____
(Name and address of the applicant)
Office Ref. No. and date if any
To The Mayor/Chairperson
Municipal Corporation/ Municipal Council/ Nagar Panchayat.
Subject : Notice of completion under rule 33.
Building Particulars : Premises No. and Street .....
.....
Ward No ....
Sir,
I / we hereby give notice that the erection / re-erection / addition to / alteration of the building on Plot No.... , Street .... Ward No.... under rule 33 has been completed according to the plan sanctioned vide Building Permit No.... dated ....
I/ we have requested you to arrange for the inspection and for the issue of an occupancy certificate.
Yours faithfully,
Countersigned
(Signature of the applicant)
Form NO.-G [See Rule No. 33] Building Completion Certificate
From: ____
(1) A = (1)/(2) B
Date:................
Reference No.....
(Owner's Name and address)
Submitted on:
To
The Mayor/Chairperson
____ Municipal Corporation/ Municipal Council/ Nagar Panchayat.
Sir ,
I/We hereby certify that :
The building(s) has been constructed to the sanctioned Plan and structural design (one set of structural drawing as executed & certified by the Structural Engineer is enclosed) which incorporates the provision of structural safety as specified in the Tripura Building Rules and in relevant prevailing Indian Standards/ Guidelines.
Construction has been done under our supervision/ guidance and adheres to the drawings submitted and records of supervision have been maintained by us.
Yours faithfully,
(Signature of Architect)
Date:
Signature of the Supervising Engineer)
Date:
Name in Block Letters:
Name in Block Letters:
Address:
Address:
Signature of owner:
Date:
Name in Block Letters:
Address:
Form I ( See Rule 38(1) ) Form of Notice of Inspection of Drains and Appliances Connected with Drainage
From :................
Dated ____
(Name and address of the applicant)
Office Ref. No. and date if any
To The Mayor/Chairperson
Municipal Corporation/ Municipal Council/ Nagar Panchayat.
Subject : Inspection of drains and appliances connected with drainage under rule 34 (1).
Building Particulars : Premises No. and Street .....
.....
Ward No ....
Sir,
I / we hereby give notice of my intention to cover up drainage/ appliances for drainage on .... (date) at ....(time) in the premises .... and request inspection of the same.
The work was sanctioned vide letter No.... dated....
Yours faithfully,
(Signature of the applicant)
Form E (See Rule 28) Form of Notice of Commencement
From :................
Dated ____
(Name and address of the applicant)
Office Ref. No. and date if any
To The Mayor/Chairperson
Municipal Corporation/ Municipal Council/ Nagar Panchayat.
Subject : Notice of commencement under rule 28 of Tripura Municipal Building rules, 2017 under Tripura Municipal Act, 1994 as per building permit no. ---- dated ----.
Building Particulars:
Premises No. and Street ....
Ward No ....
Sir,
I / we hereby give notice that the erection / re-erection of/addition to/alteration of the building on Plot No......, Street ......... Ward No............will be commenced on............ dated............ as per building permit no ---- dated ---- granted by you, with the plans and specifications sanctioned.
Yours faithfully,
(Signature of the applicant)
Form F (See Rule 29 (1)) Form of Notice of Completion of Work UP to Plinth Level or UP to 1.0 Meter Above G.L. Whichever IS Higher.
From :...................
...................
...................
(Name and address of the applicant)
Dated ____
Office Ref. No. and date if any
To The Mayor/Chairperson
Municipal Corporation/ Municipal Council/ Nagar Panchayat.
Subject : Notice of completion of structural work up to plinth level or up to 1.0 meter above G.L. whichever is higher under rule 29(1).
Building Particulars : Premises No. and Street .....
.....
Ward No ....
Sir,
I / we hereby inform you that structural construction up to the plinth level or up to 1.0 meter above G.L. whichever is higher on Plot No.... , Street .... Ward No .... for which Building permit has been issued to me vide letter No.... dated .... has been completed in accordance with the sanctioned plan.
The work may be inspected in pursuance of the provision of the sub-rule(2) of rule 29 of the Tripura Building Rules,2004 under Tripura Municipal Act,1994.
Yours faithfully,
(Signature of the applicant)
FORM J (See rule 15 (n)) FORM OF INDEMNITY BOND (To be submitted on non-judicial stamp paper of Rs. 10)
This Indemnity Bond is executed by Shri and Shri
Son- sons of Shri /late
resident of owner of premises
No. in (Name of the street and Nos. of ward).
WHEREAS I/ we am/are submitting to the Municipality /Nagar Panchayat (hereinafter referred to us the said Municipality/Nagar Panchayat) building plans with provision for deep foundations work, pilling works, construction of basement and underground constructions.
AND WHEREAS I/ we am/are representing to the said Municipality/Nagar Panchayat that if sanction is granted for the construction of the aforesaid work, I / we shall indemnity the said Municipality/Nagar Panchayat for any loss or damage at the time of execution of the said works or thereafter.
WHEREAS I/ we undertake that all precautionary measures shall be undertaken by me/us and no excavation shall be carried out beyond the boundaries of the plot. And damage occurring during the execution of the work or due to excavation made at site to the municipal/public utility services or properties shall be made good by me/ us;
WHEREAS I/ we further undertake and agree to indemnity the said Municipality/Nagar Panchayat to the full extent of any claim put up against the said Municipality/N.P. either by way of damage, compensation or pay any, other way in case the said Municipality/N.P. is required to pay any amount to any person or owner or owners of the adjoining properties;
WHEREAS I / we further undertake and agree to indemnity the said Municipality / Nagar Panchayat of all costs and expenses the said Municipality/N.P. may require to defend any action in this regard to any court of law;
NOW, THEREFORE, in consideration of the above matter, undertaking and indemnity given by the said owners, Municipality /Nagar Panchayat in this behalf, grant the sanction in the said basement to the said owners.
IN WITNESS HEREOF, the owners above mentioned put their hands and seal to the said Indemnity Bond on this ......day of ......
Witness:
(Executants)
No. 482
Registered No. N. E. 930.
TRIPURA
GAZETTE
सत्पमीव जपते
Published by Authority
Extraordinary Issue
Agartala, Monday, February 25, 2019 A. D. Phalguna 6, 1940 S. E.
PART-- I--Orders and Notifications by the Government of Tripura, The High Court, Government Treasury etc.
Government of Tripura Urban Development Department
No.F.2(466)-UDD/GL/TCPO/2018/599-627
Dated, Agartala, the 19th February, 2019.
In exercise of the powers conferred by Section 274 read with Section 118 of the Tripura Municipal Act, 1994, the State Government hereby makes the following Rules, to amend the Tripura Building Rules, 2017:-
Short title and commencement:
(i) These may be called the "Tripura Building (Amendment) Rules, 2019";
(ii) They shall come into force on the date of their publication in the Tripura Gazette.
Amendment of Rule 1:
In sub-rule (2) of rule 1 of the Tripura Building Rules, 2017 (hereinafter referred to as the Principal Rules), after the expression "Urban Local Bodies (ULBs)", the expression "and Planning Areas" shall be added.
Amendment of Rule 2:
(i) In sub-clause (66) of clause (a) of rule 2 of the Principal Rules, the expression "(a)" shall be deleted.
(ii) In clause (b) of rule 2 of the Principal Rules, after the expression "Act", the expression "and in the Tripura Urban Planning & Development Act, 2018 (The Tripura Act No 12 of 2018)" shall be added.
(i) In sub-rule (1) of rule 4 and wherever it appears here-in-after in the Principal Rules, the expression "ULB areas", shall mean and construe as "ULB areas or Local Planning areas" and the expression "ULB", shall mean and construe as "ULB or Tripura Urban Planning & Development Authority, as the case may be"; (ii) In sub-rule (2) of rule 4 and wherever it appears here-in-after in the Principal Rules, the expression "Local Bodies", shall mean and construe as "Urban Local Bodies or Tripura Urban Planning & Development Authority, as the case may be".
(i) In sub-rule (1) of rule 11 and wherever it appears herein after in the Principal Rules, the expression "Mayor/Chairperson", shall mean and construe as the "Mayor or Chairperson of the ULB or Commissioner of Tripura Urban Planning & Development Authority, as the case may be".
Amendment of sub-rule (2) of Rule 13:
In sub-rule (2) of rule 13 of the Principal Rules, in between the expressions 'shall apply to sanction giving notice in writing in Form B' and 'along with following', the expression "using online Single Window System," shall be added.
Scanned by CamScanner
8Amendment of Rule 25:
Rule 25 of the Principal Rules shall be substituted with the following-
"(1) The ULB or Tripura Urban Planning & Development Authority, as the case may be, shall levy a fee for sanction of building plan, at such rates as determined by them subject to minimum as may be determined by State Government, by notification, from
Scanned by CamScanner
time to time, on the basis of the sanctioned total covered area of the building in all floors;
(2) The ULB or Tripura Urban Planning & Development Authority, as the case may be, may levy a development fee, in addition to the fees specified in sub-rule (1), for any building, at such rate, as may be determined by the state government, by notification, from time to time."
Amendment of Rule 30:
(i) In clause (b) of sub-rule (2) of rule 30 of the Principal Rules, a proviso shall be added as follows-
"Provided that, notwithstanding anything contained in this rule, if the person referred to in sub-rule (1) of rule 13, fails to submit a revised plan incorporating the deviations intended to be carried out, for obtaining necessary sanction prior to carrying out such erection or execution of works, he may do so subsequently, by paying a penalty of three times of the prevailing per unit fee applicable towards approval of building plan to the concerned ULB, for the deviated covered area of the constructed building.";
(ii) In sub-rule (2) of rule 30 of the Principal Rules, after clause (b), a new clause (c) shall be added as follows-
"(c) if during the erection or execution of a work, any external deviation beyond sanctioned covered space is intended to be made, which violate the provisions of the Act or these rules, the person referred to sub-rule (1) of rule 13 shall, prior to carrying out such erection or execution of works, submit, in accordance with the provisions of this rule, a revised plan incorporating the deviations intended to be carried out, for obtaining necessary relaxation of rules and sanction thereof.";
(iii) In sub-rule (3) of rule 30 of the Principal Rules, after the expression ‘clause (b)', the expression “or (c)” shall be added;
(iv) In sub-rule (3) of rule 30 of the Principal Rules, a proviso shall be added as follows-
Provided that, for marginal external deviations made during construction as mentioned below for a building having height upto 18 meters, may be compounded on payment of compounding fee as specified against each type of deviation. The total Compounding fees will be the aggregate of Compounding fees for all types of deviations as mentioned below-
12Amendment of Rule 47:
Sub-rule (3) of rule 47 of the Principal Rules shall be substituted with the following:
"(3) The maximum permissible height of a building, including the stilt parking or basement, on a plot shall not be more than the Maximum permissible height, as given in the table below-"
Width of means of access(in metres)
Maximum permissible height(in metres)
(a) Road width from 1.80 and upto 2.40
Upto 08.00
(b) Road width above 2.4 and upto 5.00
Upto 12.50
(c) above 5.00 and less than 10.00
Upto 14.50
(d) 10.00 and above
Tall buildings (i.e above 14.5 mt.)”
Explanation: - This table shall be read with rule 45.
13Amendment of Rule 48:
(i) Sub-rule (2) of rule 48 of the Principal Rules shall be substituted with the following-
“(2) The minimum front open spaces shall be as follows:-
Every building shall have a minimum front open space at ground level (open to the sky without any cantilever projection excepting chajja or weather shades of not more than 0.50 meter width) of a width at its narrowest part of not less than that indicated below-
Use of building
Height of building (metres)
Minimum front open space at ground level at its narrowest part (metres)
Residential
Upto 14.50
1.80
Commercial having built up area upto 100 sqm.
Upto 14.50
1.80
Commercial having built up area more than 100 sqm.
Upto 14.50
3.00
Assembly/ Institutional/Educational/ Club
Upto 14.50
3.00
Industrial/ Mercantile (Wholesale)/Storage
Upto 14.50
3.00
Others not specified above
Upto 14.50
1.80
Explanation: - For height of buildings exceeding 14.50 meters, rule 50 shall be referred to.
Provided that, a building upto 8.00 mt. of height, on a plot measuring not more than 165 sqm, should have a minimum front open space of 01.20 mt.
Provided further that, for mixed use buildings, the minimum front open space shall be the one, applicable for that particular occupancy which gives the highest provision of the minimum front open space in this rule.
Note: mixed use building means and includes the combination of residential, commercial, industrial, office, institutional or other uses."
Scanned by CamScanner
Tripura Gazette, Extraordinary Issue, February 25, 2019 A. D.
(ii) Sub-rule (3) of rule 48 of the Principal Rules shall be substituted with the following:
"(3) The minimum rear open space shall be as follows:-"
Every building shall have a minimum rear open space at ground level (open to the sky without any cantilever projection excepting chajja or weather shades of not more than 0.50 metre width) of a width at its narrowest part of not less than that indicated below:-
7Amendment of sub-rule (2) of Rule 20:
In rule 20 of the Principal Rules, after sub-rule (2), a new sub-rule (3) shall be added as follows-
"(3) (a) Risk Based Classification of building proposals: - For approval of the building plan proposals, the following Risk Based Classification and fast tracking tools shall be followed-"
Risk
Very Low
Low
Moderate
High
Criteria
Size of the plot (Square Meters)
Upto 65 sqmt
Above 65 sqmt and upto 500 sqmt
Above 500 sqmt and upto 1500 sqmt
Above 1500 sqmt
Height of building (Meters)
Below 8 m
Upto 14.5 m
Above 14.5 m up to 30 m
Above 30 m
Use of the premise
All uses
All uses
All uses
All uses
Fast Tracking Tools
As per Rule - 54 (10)
As per Rule - 20 (1)
As per Rule - 50
As per Rule - 50 and in addition, rule 20(3)(b) will apply for this category.
(b) For the High-risk buildings, as categorized under clause (a) of this sub-rule, the following special provisions will apply.-
(i) All building shall be provided with such number of staircases as the ULB or the Tripura Urban Planning & Development Authority, as the case may be, require and under no circumstance, the number of staircases shall be less than 3(three) in the case where a building is of more than 30 (thirty) meters in height and in such case one of the staircases shall be on the external face of such building;
(ii) Sufficient numbers of Disaster Gallery and openable Windows as emergency exit as per the requirement of the ULB or Tripura Urban Planning & Development Authority, as the case may be, shall be provided in each floor beyond 30 (thirty) meters height of the building;
(iii) Inspection of the construction will be done at different stages of construction by a Technical committee constituted by the concerned ULB or Tripura Urban Planning & Development Authority, as the case may be;
(iv) during inspection by the Technical Committee, so constituted, if anything found not technically suitable or beyond the approved plan, the committee shall report the matter to the concerned ULB or Tripura Urban Planning & Development Authority, as the case may be, on the basis of which the concerned ULB or Tripura Urban Planning & Development Authority, as the case may be, shall take appropriate action which may lead to cancellation of the approved plan."
17Amendment of Rule 53:
(i) ) In rule 53 of the Principal Rules, the expression "or is older than 50 (fifty) years" shall be deleted.
(ii) In rule 53 of the Principal Rules, the following proviso shall be added-
"Provided that the owner of all such buildings, without provisions of seismic considerations, must retrofit their buildings with the help of expert agency, firm, Architect or Engineer, empanelled by the ULB or Authority, for this purpose and obtain a safety certificate after necessary structural improvement, if needed. The ULB or Authority will empanel expert agency, firm, Architect, Engineer for this purpose."
18Amendment of Rule 105:
In rule 105 of the Principal Rules, after sub-rule (3), a new sub-rule (4) of shall be added as follows-
"(4) The State Government may by Notification, to be published in official gazette, prescribe separate Green Rating systems for buildings by selectively combining, adopting and or amending the provisions from the following guidelines-"
* Indian Green Building Council (IGBC) guidelines by the Confederation of Indian Industries, and or
* Green Building for Integrated Habitat Assessment (GRIHA) guidelines by the Ministry of New and Renewable Energy, Government of India, and or
Scanned by CamScanner
* Energy Conservation Building Code (ECBE) guidelines prepared by Bureau of Energy Efficiency, Ministry of Power, Government of India, and or
* Model Energy Efficiency guidelines, and or any other guidelines, time to time prescribed by Government of India or any State Government."
19 Insertion of new Rule 110:
In clause (c) of rule 110 of the Principal Rules, after the expression "10,000 square meters". the expression "OR ε" plots having area exceeding 5 000 square meters OR all group housing complex having provision exceeding 200 dwelling units" shall be added.
16Amendment of Rule 52:
Sub-rule (2) of rule 52 of the Principal Rules shall be substituted with the following-
"(2) In the case of existing building. -"
(a) Except the storage buildings, where the open spaces required have not been provided an addition of one storey, if otherwise permissible, may be allowed with the already approved set back, provided such building continues with the same occupancy; Provided that the existing building is in conformity with the already approved plan;
Provided further that the structural stability is certified by the authorized technical persons based on structural record on the approved plan and constructed building condition;
(b) if any car parking space is required to be provided under these rules and no such car parking space can be provided in such existing building, the covered area allowable under the provisions of these rules shall be reduced by the area required for such car parking space which can not be provided in the said building;
Explanation.- For the purpose of calculation, the area required for one car parking space shall be taken as 20.00 sq. meters.
(c) the height of the building shall conform to the rules as indicated in rule 45 and 47 and in no case after addition the height shall exceed 14.5 meters ;
(e) the ground coverage of the building shall conform to the rules as indicated in rule 46."
14Amendment of Rule 50:
(i) In rule 50 of the Principal Rules, the expression "In ULB the building height shall not normally be more than 14.50 meters (fourteen and half). But in the case of any building exceeding 14.50 meters in height, the ULB" shall be substituted with the expression "In the case of any building exceeding 18 meters in height, the ULB / Tripura Urban Planning & Development Authority, as the case may be" and the expression "In such cases" shall be substituted with the expression "For the buildings having height more than 14.50 meters (fourteen and half)";
(ii) In clause (1) of rule 50 of the Principal Rules, the expression “15.00 meters in width” shall be substituted with the expression “10.00 (ten) meters in width including drains”;
(iii) Clause (2) of rule 50 of the Principal Rules shall be substituted with the following-
"(2) every building exceeding 14.5 (fourteen and half) meters in height shall have a minimum front open space at ground level (open to the sky without any cantilever projection excepting chajja or weather shades of not more than 0.50 metre width) as indicated below:-
Height of building (meters)
Minimum front open space at ground level at its narrowest part (meters)
Above 14.50 but not more than 25.00
3.00
Above 25.00
5.00
(iv) Clause (3) of rule 50 of the Principal Rules shall be substituted with the following-
"(3) every building exceeding 14.5 (fourteen and half) meters in height shall have a minimum rear open space at ground level (open to the sky without any cantilever projection excepting chajja or weather shades of not more than 0.50 metre width) as indicated below:-
Scanned by CamScanner
Tripura Gazette, Extraordinary Issue, February 25, 2019 A. D.
Height of building (meters)
Minimum rear open space at its narrowest part (meters)
Above 14.50 but not more than 18.00
3.50
Above 18.00 but not more than 30.00
5.00
Above 30.00
20Insertion of new Rule 112:
A new rule 112 shall be added in the Principal Rules, as follows-
"112. Climate resilient construction - Integration of environmental clearance with sanction:
The new building construction proposals are classified in the following three categories: -
A) Category 'A' Buildings: Built-up Area from 5000 sqmt upto 20,000 sqmt
B) Category 'B' Buildings: Built-up Area above 20,000 sqmt upto 50,000 sqmt
C) Category 'C' Buildings: Built-up Area above 50,000 sqmt
A local Authority, i.e. ULB / Development Authority / any other body authorized to sanction building plans shall approve the building plans by ensuring the stipulated conditions in the following Table-1, 2 and 3 for the respective categories of buildings.
Table 1: Environmental Conditions for Building and Construction
(Category "A" from 5000 sqmt upto 20,000 sqmt)
Sl.No.
MediumNo.
Environmental conditions
Rule
1
Natural Drainage
The inlet and outlet point of natural drain system should be maintained with adequate size of channel for ensuring unrestricted flow of water
2
Water Conversations Rain Water Harvesting and Ground Water Recharge
A rain water harvesting plan needs to be designed where the recharge bores (minimum one per 5000 sqm of built up area) shall be provided. The rain water harvested should be stored in a tank for reuse in household through a provision of separate water tank and pipeline to avoid mixing with potable municipal water supply. The excess rain water harvested is to be linked to the tube well bore in the premise through a pipeline after filtration in the installed filters.
110 (a)
2(a)
The unpaved area shall be more than or equal to 20% of the recreational open spaces.
3
Solid Waste Management
Separate wet and dry bins must be provided at the ground level for facilitating segregation of waste.
110(c)
4
Energy
Tripura Gazette, Extraordinary Issue, February 25, 2019 A. D.
a) Inadequate Open Space, in violation of Rule 48 and 50:-
Quantum of infringement in open space
Compounding fee
Infringement in open space upto 5% of required open space for the height of the constructed building (not the approved building height) as per requirement of rule - 48 and 50 in one or more sides(front, rear or any sides) of the building.
per unit fee applicable for approval of building plan of concerned ULB or Authority, and to be calculated for the entire covered area of the constructed building.
Infringement in open space upto 10% of required open space for the height of the constructed building (not the approved
2 (three) times of the per unit fee applicable for approval of building plan of concerned ULB or Authority, and to be
Scanned by CamScanner
building height) as per requirement of rule - 48 and 50 in one or more sides(front, rear or any sides) of the building.
calculated for the entire covered area of the constructed building.
Infringement in open space upto 20% of required open space for the height of the constructed building (not the approved building height) as per requirement of rule - 48 and 50 in one or more sides(front, rear or any sides) of the building.
3 (three) times of the per unit fee applicable for approval of building plan of concerned ULB or Authority, and to be calculated for the entire covered area of the constructed building.
Infringement in open space more than 20% of required open space for the height of the constructed building (not the approved building height) as per requirement of rule - 48 and 50 in one or more sides(front, rear or any sides) of the building.
Non-compoundable and liable for action as per rule - 31.
b) Cantilever projection:-
For the cantilever projections not shown in the approved building plan, the per unit compounding fee will be 10 (ten) times of the per unit fee applicable for approval of building plan of concerned ULB or Authority, for the cantilever portion only;
Provided that, in any case the cantilever projection should not be more than 0.9 meter and it should not be projected beyond the property line of the owner of the building;
c) Height of the building: -
For increase in height during construction, beyond approved building height within overall building height, not exceeding 18 meters without increasing number of storey, the compounding fee will be as follows-
Usage of building
Increase in height
Compounding fee
Residential use
Increase in height for every 30 centimeters or part there off
Rs 10,000/-
other than residential use
Increase in height for every 30 centimeters or part there off
Rs 30,000/-
d) Covered area: -
For excess covered area beyond sanctioned covered area as per approved building plan, the compounding fee will be 5 (five) times of the per unit fee applicable for approval of building plan of concerned ULB or Authority, for the excess covered area;
e) Ground coverage: -
For excess ground coverage beyond permissible coverage as per rule – 46 but maximum upto overall ground coverage of 90%, the compounding fee will be Rs. 10,000/- for every 1% or part thereof excess ground coverage;
f) Parking provision: -
For shortfall of parking space required as per rule - 49, the compounding fee will be as follows:
Scanned by CamScanner
Tripura Gazette, Extraordinary Issue, February 25, 2019 A. D.
Requirement of parking as per rule - 49
Shortfall of parking space
Compounding fee
Upto 3 (three)
Shortfall upto 2 (two) parking space
Rs 1,00,000/- per parking space
Shortfall of 3 (three) parking space
Non-compoundable
More than 3 (three)
Shortfall upto nearest whole number of 20% of requirement of parking space
Rs 1,50,000/- per parking space
Shortfall more than nearest whole number of 20% of requirement of parking space
Non-compoundable
g) FAR (if applicable): -
For excess FAR availed beyond permissible limit, the compounding fee will be Rs. 10,000/- for every 0.1 excess FAR or part thereof;
h) Use of building:-
For change in usage of building from Residential to Commercial or in any other manner, the compounding fee will be 3 (three) times of the per unit fee applicable for approval of building plan of concerned ULB or Authority, and to be calculated for the covered area for which use has been changed;
i) Construction without approved plan: -
a) For the buildings constructed without prior approval of the building plan but the construction so made fully conforms to the provisions of the Tripura Building Rules, 2017, the compounding fee will be 3 (three) times of the per unit fee applicable for approval of building plan of concerned ULB or Authority, and to be calculated for the entire covered area of the constructed building;
b) For the buildings constructed without prior approval of the building plan and the construction so made does not conform to the provisions of the Tripura Building Rules, 2017, the compounding fee will be 3 (three) times of the per unit fee applicable for approval of building plan of concerned ULB or Authority, and to be calculated for the entire covered area of the constructed building in addition to the compounding fees applicable for violation of the respective provision of Tripura Building Rules, 2017, as specified in rule - 30(3);
Provided that, in all the above cases of construction without approved plan, the owner should submit the structural safety certificate for the existing building from appropriate technical personnel as specified in rule -17."
10 Amendment of Rule 42:
In rule 42 in the Principal Rules, the expression "Indian Electricity Act, 1910 (9 of 1910)", shall mean and construe as "Electricity Act, 2003 (36 of 2003)".
11 Amendment of Rule 46:
Sub-rule (1) of rule 46 of the Principal Rules shall be substituted with the following-
Scanned by CamScanner
"(1) The maximum permissible ground coverage for a building, when a plot contains a single building, shall be 70% for Buildings of any type of uses."
Height of building (metres)
Minimum rear open space at its narrowest part (metres)
Up to 10.00
1.00
Above 10.00 but not more than 14.50
1.20
Explanation: - For height of buildings exceeding 14.50 meters, rule 50 shall be referred."
10.00
Provided that, if horizontal distance of any part of the building is more than 30 meters from the approach road of not less than 10 meters in width then minimum rear open space at its narrowest part should be 10.00 meters irrespective of the height of the building.
Provided further that, the rear open space shall be of hard surface capable to take load of fire engine weighting upto 45 tonnes."
(v) Clause (4) of rule 50 of the Principal Rules shall be substituted with the following-
"(4) every building exceeding 14.5 (fourteen and half) meters in height shall have a minimum side open space at ground level (open to the sky without any cantilever projection excepting chajja or weather shades of not more than 0.50 metre width) as indicated below:-
Height of building (meters)
Minimum side open space at its narrowest part (meters)
Side 1
Side 2
Above 14.50 but not more than 30.00
3.50
3.50
Above 30.00
5.00
5.00
Provided that, minimum side open space should be such that the appropriate fire engine can move freely around the building in case of necessity. Appropriate Turning radius should also be maintained in all corner of the building for this purpose.
Provided further that, the side open space shall be of hard surface capable to take load of fire engine weighting upto 45 tonnes "
(vi) sub-clause (a) of clause (6) of rule 50 of the Principal Rules shall be substituted with the following-
"(6)(a) For a building exceeding 14.5 (fourteen and half) meters in height, the Floor Area Ratio (FAR) shall be 3;
Provided that, the applicant may get the Floor Area Ratio (FAR) increased from the authority competent to approve it, on payment of a fee for additional Floor Area Ratio (FAR) beyond 3 upto 5, at such rates as determined by the authority competent to approve subject to minimum as may be determined by State Government from time to time.
Provided further that, for relaxation of Floor Area Ratio (FAR) beyond 5, approval of State Government shall be necessary and on payment of a fee for additional Floor Area Ratio (FAR) beyond 5, at such rates as may be determined by State Government from time to time"
(vii) sub-clause (b) of clause (6) of rule 50 of the Principal Rules, the expression "rule 50", shall mean and construe as "rule 49".
Scanned by CamScanner
15 Amendment of Rule 51:
Sub-rule (2) of rule 51 of the Principal Rules shall be substituted with the following-
"(2) Ground Coverage shall be as laid down below :-"
The maximum permissible ground coverage for a building of any type of uses shall not be more than 70%.”
In common areas, LED/ solar lights must be provided.
105 to 107
5
Air Quality and Noise
Dust, smoke and debris prevention measures such as screens, barricading shall be installed at the site during construction, Plastic/ tarpaulin sheet covers must be used for trucks bringing in sand and material at the site.
5(a)
The exhaust pipe of the DG set if installed, must be minimum 10m away from the building. In case it is less than 10m away, the exhaust pipe shall be taken up to 3m
Scanned by CamScanner
Tripura Gazette, Extraordinary Issue, February 25, 2019 A. D.
above the building.
6
Green cover
A minimum of 1 tree for every 80 sqm of land shall be planted and maintained. The existing trees will be counted for this purpose. Preference should be given to planting native species.
6(a)
Where the trees need to be cut, compensatory plantation in the ratio of 1:3 (i.e., planting of 3 trees for every one tree that is cut) shall be done with the obligation to provide continued maintenances for such plantations
Table 2Environmental Conditions for Building and Construction (Category "B" above 20,000 sqmt upto 50,000 sqmt.)
SI, No.
Medium
Environmental conditions
Rule
1
Natural Drainage
The inlet and outlet point of natural drain system should be maintained with adequate size of channel for ensuring unrestricted flow of water
110 (a)
2
Water Conversations Rain Water Harvesting and Ground Water Recharge
A rain water harvesting plan needs to be designed where the recharge bores (minimum one per 5000 sqm of built up area) shall be provided. The rain water harvested should be stored in a tank for reuse in household through a provision of separate water tank and pipeline to avoid mixing with potable municipal water supply. The excess rain water harvested is to be linked to the tube well bore in the premise through a pipeline after filtration in the installed filters.
2(a)
The unpaved area shall be more than or equal to 20% of the recreational open spaces.
3
Solid Waste Management
Separate wet and dry bins must be provided at the ground level for facilitating segregation of waste.
110(c)
4
Energy
In common areas, LED/ solar lights must be provided.
105 & 107
4(a)
At least 1% of connected applied load generated from renewable energy source such as photovoltaic cells or wind mills or hybrid should be provided.
4(b)
As per the provisions of the Ministry of New and Renewable energy solar water heater of minimum capacity 10 litres/4 persons (2.5 litres per capita) shall be installed
108 & 109
4 (c)
Use of fly ash bricks: Fly ash should be used as building material in the construction as per the provisions of Fly Ask Notification of September, 1999 and as amended from time to time.
5
Air Quality and Noise
Dust, smoke and debris prevention measures such as screens, barricading shall be installed at the site during construction, Plastic/ tarpaulin sheet covers must be used for trucks bringing in sand and material at the site.
5(a)
The exhaust pipe of the DG set, if installed, must be minimum 10m away from the building. In case it is less than 10m away, the exhaust pipe shall be taken up to 3m above the building.
6
Green cover
A minimum of 1 tree for every 80 sqm of land shall be planted and maintained. The existing trees will be counted for this purpose. Preference should be given to planting native species.
6(a)
Where the trees need to be cut, compensatory plantation in the ratio of 1:3 (i.e., planting of 3 trees for every one tree that is cut)
Scanned by CamScanner
Tripura Gazette, Extraordinary Issue, February 25, 2019 A. D.
shall be done with the obligation to provide continued maintenances for such plantations.
Table 3Environmental Conditions for Building and Construction (Category "C" above 50,000 sqmt.)
SI, No.
Medium
Environmental conditions
Rule
1
Natural Drainage
The inlet and outlet point of natural drain system should be maintained with adequate size of channel for ensuring unrestricted flow of water
2
Water Conversations Rain Water Harvesting and Ground Water Recharge
A rain water harvesting plan needs to be designed where the recharge bores (minimum one per 5000 sqm of built up area) shall be provided. The rain water harvested should be stored in a tank for reuse in household through a provision of separate water tank and pipeline to avoid mixing with potable municipal water supply. The excess rain water harvested is to be linked to the tube well bore in the premise through a pipeline after filtration in the installed filters.
110 (a)
2(a)
The unpaved area shall be more than or equal to 20% of the recreational open spaces.
2(b)
The ground water shall not be withdrawn without approval from the competent authority.
2 (c)
Use of potable water in construction should be minimized.
2(d)
Low flow fixtures and sensors must be used to promote water conversation.
105
2(e)
Separation of grey and black water should be done by the use of dual plumbing system.
3
Solid Waste Management
Separate wet and dry bins must be provided at the ground level for facilitating segregation of waste.
110(c)
3(a)
All non-biodegradable waste shall be handed over to authorized recyclers for which a written tie-up must be done with the authorized recyclers.
3(b)
Organic waste composter/ vermiculture pit with a minimum capacity of 0.3 kg/tenement/day must be installed wherein the STP sludge may be used to be converted to manure which could be used at the site or handed over to authorized recyclers for which a written tie-up must be done with the authorized recyclers.
4
Energy
In common areas, LED/ solar lights must be provided.
105 & 107
4(a)
At least 1% of connected applied load generated from renewable energy source such as photovoltaic cells or wind mills or hybrid should be provided.
4(b)
As per the provisions of the Ministry of New and Renewable energy solar water heater of minimum capacity 10 litres/4 persons (2.5 litres per capita) shall be installed
108 & 109
4 (c)
Use of fly ash bricks: Fly ash should be used as building material in the construction as per the provisions of Fly Ask Notification of September, 1999 and as amended from time to time.
4(d)
Use of concept of passive solar design of building using architectural design approaches that minimize energy consumption in buildings integrating conventional energy-
Scanned by CamScanner
Tripura Gazette, Extraordinary Issue, February 25, 2019 A. D.
4(e)
efficient devices, such as mechanical and electric pumps, fans, lighting fixtures and other equipment, with the passive design elements, such as building orientation, landscaping, efficient building envelope, appropriate fenestration, increased day lighting design and thermal mass
105
Optimize use of energy system in buildings that should maintain a specific indoor environment conducive to the functional requirements of the building by following mandatory compliance measures ( for all applicable buildings) as recommended in the Energy Conservation Building Code (ECOBC) 2007 of the Bureau of Energy Efficiency, Government of India.
5
Air Quality and Noise
Dust, smoke and debris prevention measures such as screens, barricading shall be installed at the site during construction, Plastic/ tarpaulin sheet covers must be used for trucks bringing in sand and material at the site.
5(a)
The exhaust pipe of the DG set, if installed, must be minimum 10m away from the building. In case it is less than 10m away, the exhaust pipe shall be taken up to 3m above the building.
6
Green cover
A minimum of 1 tree for every 80 sqm of land shall be planted and maintained. The existing trees will be counted for this purpose. Preference should be given to planting native species.
6(a)
Where the trees need to be cut, compensatory plantation in the ratio of 1:3 (i.e, planting of 3 trees for every one tree that is cut) shall be done with the obligation to provide continued maintenances for such plantations.
7
Sewage Treatment Management Plan
Sewerage treatment plant with capacity of treating 100% waste water shall be installed. Treated water must be recycled for gardening and flushing.
110(b)
8
Environment Management Plan
The environment infrastructure like Sewerage Treatment Plant, Landscaping, Rain Water Harvesting, Power backup for environment, Infrastructure, Environment Monitoring, Solid Waste Management and Solar and Energy conversation, should be kept operational through Environment Monitoring Committee with defined functions and responsibility.
By order of the Governor,
[Secretary to the Government of Tripura]
Printed at the Tripura Government Press, Agartala.
Scanned by CamScanner
Government of Tripura Urban Development Department
NO.F.2(466)-UDD/GL/TCPO/2018(P-1)/1141-1152 Dated, Agartala, the ( February, 2020
In exercise of the powers conferred by Section 274 read with Section 118 of the Tripura Municipal Act, 1994, the State Government hereby makes the following Rules, to amend the Tripura Building Rules, 2017 (hereinafter referred to as the Principal Rules):-
1 Short title and commencement:
(i) These may be called the "Tripura Building (Second Amendment) Rules, 2020";
(ii) They shall come into force on the date of their publication in the Tripura Gazette.
6Amendment of Rule 47:
Sub-rule (3) of Rule 47 of the Principal Rules shall be substituted with the following-
“(3) The maximum permissible height of a building, including the stilt parking or basement, on a plot, shall not be more than the Maximum permissible height, as given in the table below:-”
Scanned by CamScanner
(i) Residential building
Width of means of access(in metres)
Maximum permissible height (in metres)
(a) Road width from 1.80 and upto 2.40
Upto 08.00
(b) Road width above 2.4 and upto 6.00
Upto 12.50
(c) Road width above 6.00 and upto 7.50
Upto 17.50
(d) Road width above 7.50 and upto 10.00
Upto 20.50
(e) Road width more than 10.00
Above 20.50 (subject to the permission of the AAI)
(ii) Other then Residential building
Width of means of access(in metres)
Maximum permissible height (in metres)
(a) Road width from 1.80 and upto 2.40
Upto 08.00
(b) Road width above 2.4 and upto 6.00
Upto 12.50
(c) Road width above 6.00 and upto 10.00
Upto 14.50
(d) Road width more than 10.00
Above 14.50 (subject to the permission of the AAI)
Explanation 1: In cases of (c), (d) & (e) above for residential building and in cases of (c) & (d) above for other then residential building, there shall be provision for free space of minimum 40 ft X·30 ft, in addition to the open space prescribed in these rules, for stationing the fire safety vehicles (Tenders/ Hydraulic platform/other similar vehicle) and also in the road (access) approaching the worksite/building site there shall be provision for sufficient radius for turning (minimum 8 mtr. radius) in curves (if any).
Explanation 2: This table shall be read with Rule 45 and rule 50.”
5Inclusion of new provision under Rule 42:
Rule 42(A) and 42(B) shall be inserted after Rule 42 of the Principal Rules with the following-
"42(A). An exclusive area of isolation of minimum 8 sqm in size in a building having number of story G+4 or above or having covered area more than 500 sqm may be kept for providing and installing electric meter boxes, power mains and other required power installations.
42(B). Consultation with the Power Department before granting permission to erect a building:-
(i) No permission for erection, addition to or alteration of any Residential Building other than a building upto 15.00 m in height and/or having covered area upto 1000 sqm (as the case may be) shall be granted unless a 'No Objection Certificate (NOC)' is obtained through the Online system for Building Plan approval from the Power Department of the Government of Tripura through any officer specially empowered by the Power Department for this purpose.
(ii) No permission for erection, addition to or alteration of any non-residential Building other than a building upto 15.00 m in height and/or having covered area upto 500 sqm (as the case may be) shall be granted unless a 'No Objection Certificate (NOC)' is obtained through the Online system for Building Plan approval from the Power Department of the Government of Tripura through any officer specially empowered by the Power Department for this purpose."
2Amendment of Rule 3:
Rule 3 of the Principal Rules shall be substituted with the following-
"Power to relax rules:- Notwithstanding anything contained in these rules, a ULB or other concerned authorities may, for reasons to be recorded in writing and with the previous approval of the State Government, relax any provision of these rules, for dealing with a case, if such relaxation is not otherwise inconsistent with any provision of the Tripura Municipal Act, 1994 or any other law for the time being in force, without compromising structural safety of the building and after ensuring necessary disaster safety norms including fire safety norms."
3 Amendment of Rule 13:
In rule 13 of the Principal Rules, after sub-rule (2), a new sub-rule (3) shall be added as follows-
"(3)(a) Building permission and occupancy certificate within the Notified Local Planning Area shall be given from the Tripura Urban Planning & Development Authority;
(b) For Building/Townships comprising 50 (fifty) nos. of Flats or above or project area of one acre or above, inside the ULB area, the notification of Township along with building permission and occupancy certificate shall be given from Tripura Urban Planning & Development Authority."
Scanned by CamScanner
4 Amendment of Rule 14:
(i) Sub-rule (1) of Rule 14 of the Principal Rules shall be substituted with the following –
"(1) Every application made under Rule 13 shall be using online single window system and shall state the location of the site and such other particulars as may be specified by the ULB."
(ii) Sub-rule (3), (4) and (9) of Rule 14 of the Principal Rules shall be deleted.
(iii) In Sub-rule (5) of Rule 14 of the Principal Rules the expression "and coloured in the manner as laid down in Table 2 of rule-14" shall be deleted.
7Amendment of Rule 72:
Rule 72 of the Principal Rules shall be substituted with the following-
"Fire protection:-
Scanned by CamScanner
(i) Every Residential Building having height above 15.00 m and/or covered area of more than 1000 sqm (as the case may be) shall be provided with adequate means of exit and all arrangements for protection in case of fire as per requirements under this rule.
(ii) Every building other than Residential having height above 15.00 m and/or covered area of more than 500 sqm (as the case may be) shall be provided with adequate means of exit and all arrangement for protection in case of fire as per requirements under this rule."
8Amendment of Rule 75:
Rule 75 of the Principal Rules shall be substituted with the following-
"Requirements regarding staircase and lift/elevator -
(1) All building referred to in rule 72 shall be provided with such number of staircase as may be required and under no circumstances, the number of staircases shall be less than 2 (two) in the case of the building of more than 14.5 (fourteen and half) meters in height and one of them shall be on the external face of the building;
provided that in case of buildings having the area of each floor exceeding 400 sqm but height less than 14.5 (fourteen and half) meters the number of staircases shall also be at least 2(two).
(2) (a) Provision of lift shall be mandatory for the residential buildings of G+4 or above and for the residential buildings of G+6 or above there shall be provision for minimum two lifts.
(b) Provision of lift shall be mandatory for the buildings other than residential of G+3 or above and for the buildings other than residential of G+5 or above there shall be provision for minimum two lifts."
13Amendment of Rule 110:
(i) In clause (1) of sub-rule (a) of Rule 110 of the Principal Rules, the expression “200 sq.m” shall be substituted with the expression “150 sq.m”;
(ii) In the second column of third row, of the table appended to clause (3) of sub-rule (a) of Rule 110 of the Principal Rules, against the Category/Use - New
Scanned by CamScanner
Proposals for 'Residential Plotted House', the expression "200 and above" shall be substituted with the expression "150 and above".
(iii) In clause (5) of sub-rule (a) of Rule 110 of the Principal Rules, the expression "500 sq.m and above" shall be substituted with the expression "400 sq.m. and above".
(iv) In Rule 110 of the Principal Rules, after sub-rule (c), new sub-rules (d) and (e) shall be added as follows-
“(d) Provision for Soak Pit for septic tank shall be mandatorily made in all residential and commercial building/group of Houses/Township where there is no underground sewerage system. Soak pit may be allowed in open space and a projection upto 750 mm from the building line may be allowed in setting up of septic tank in residential building.
(e) Sewage Treatment plant (STP) shall be mandatory for all the projects such as townships, group housings etc. (with minimum 50 Flats/Dwelling units or project area of one acre or above) where the facility of underground sewerage system is not available. Also re-use of water generated from STP shall be mandatory."
By order of the Governor,
[Secretary to the Government of Tripura]
To
The Manager, Govt. Press, Agartala. He is requested to publish the above Notification in the next issue of the Tripura Gazette. 200 (two hundred) copies of the Gazette Notification in book shape may kindly be sent to this Department in due course.
Copy to :
The Principal Secretary to the His Excellency Governor, Tripura, Raj Bhawan, Agartala.
The Additional Chief Secretary to the Hon'ble Chief Minister, Tripura.
The PS to the Hon'ble Minister, Urban Development Department.
The PS to the Hon'ble Minister....;
The PS to the Chief Secretary, Tripura.
PS/PA to all Principal Secretary / Secretary....
Scanned by CamScanner
The Director, ICA with a request to publish this Notification in two leading Newspapers, one of which shall be in vernacular.
All Departments/Heads of Departments.
The Municipal Commissioner, Agartala Municipal Corporation, Agartala, Tripura(w).
Director
Urban Development Department
Government of Tripura.
Scanned by CamScanner
No.1911
Registered No. N. E. 930.
TRIPURA
GAZETTE
Extraordinary Issue
Agartala, Friday, December 2, 2022 A. D., Agrahayana 11, 1944 S. E.
PART-I- Orders and Notifications by the Government of Tripura, The High Court, Government Treasury etc.
GOVERNMENT OF TRIPURA
URBAN DEVELOPMENT DEPARTMENT
No.F.01(24)-TUDA/Estt/2022/4902-30
Dated, Agartala, the 29th November, 2022.
In exercise of powers conferred by section 118 read with section 274 of the Tripura Municipal Act, 1994, the State Government hereby makes the following Rules further to amend the Tripura Building Rules, 2017, namely :
1 Short title and commencement:
(1) These rules may be called the Tripura Building (3rd Amendment) Rules, 2022.
(2) They shall come into force on the date of their publication in the Tripura Gazette.
12Amendment of Rule 89:
Rule 89 of the Principal Rules shall be substituted with the following-
"Power to relax rules:- Notwithstanding anything contained in these rules, a ULB or other concerned authorities may, for reasons to be recorded in writing and with the previous approval of the State Government, relax any provision of these rules, for dealing with a case, if such relaxation is not otherwise inconsistent with any provision of the Tripura Municipal Act, 1994 or any other law for the time being in force, without compromising structural safety of the building and after ensuring necessary disaster safety norms including fire safety norms."
11Amendment of Rule 79:
Rule 79 of the Principal Rules shall be substituted with the following-
"Consultation with the Director of Fire Services before granting permission to erect a building:-
(i) No permission for erection, addition to or alteration of any Residential Building other than a building upto 15.00 m in height and/or having covered area upto 1000 sqm (as the case may be) shall be granted unless a 'No Objection Certificate (NOC)' is obtained through the Online system for Building Plan approval from the Director, Fire Service of the Government of Tripura or any officer specially empowered by the Director, Fire Service.
(ii) No permission for erection, addition to or alteration of any non-residential Building other than a building upto 15.00 m in height and/or having covered area upto 500 sqm (as the case may be) shall be granted unless a 'No Objection Certificate (NOC)' is obtained through the Online system for Building Plan approval from the Director, Fire Service of the Government of Tripura or any officer specially empowered by the Director, Fire Service."
9Amendment of Rule 76:
Sub-rule (a), (b), (c), (d), (e) and (f) of Rule 76 of the Principal Rules shall be substituted with the following -
"The following minimum width shall be provided for staircases for respective occupancies:
(a) Residential
i. One or two family private dwellings - 1.00 m
ii. Lodging and rooming houses,
Dormitories and Apartment houses - 1.25 m
iii. Hotels and Starred hotels - 1.50 m
(b) Assembly
i. Assembly occupancy having less than 150 persons – 1.50 m
ii. Assembly occupancy having 150 persons or more – 2.00 m
(c) Educational - 1.50 m
(d) Industrial - 2.00 m
(e) All other occupancies – 1.50 m"
10 Amendment of Rule 78:
Rule 78 of the Principal Rules shall be substituted with the following-
Scanned by CamScanner
"Other requirements:-
Fire prevention and fire protection measures like Fire Extinguisher, First Aid Hose Reel, Wet Riser, Down Corner, Yard Hydrant, Automatic Sprinkler System, Fire Alarm System, Automatic Detection and Alarm System, Under-ground Static Water Storage Tank, Fire pumps, Exist signage lighting, Emergency lighting, Public address system, Service ducts and shafts etc are to be provided in all buildings referred in rule 72 of the Principal Rules"
2Amendment to Rule 47:
In the Tripura Building Rules, 2017 (hereinafter referred to as the principal rules) in rule 47, in sub-rule (3).
(1) For explanation 1, the following explanation shall be substituted, namely: "Explanation 1: Additional 1 (one) floor height, is permissible in case of donation of 2.5 metre strip of land along the entire frontage of the plot for road widening under the provision of LAP (Local Area Plan) / TPS (Town Planning Scheme) / TOD (Transit Oriented Development)."
(2) For explanation 2, the following explanation shall be substituted, namely: "Explanation 2: The table shall be read with Rule 45."
3Amendment to Rule 75:
In the principal rules, for rule 75, the following rule shall be substituted, namely:-
*Requirements regarding staircase and lift/elevator:
All building referred to in Rule 72 shall be provided with such number of staircase as may be required and under no circumstances, the number of staircases shall be less than 2 (two) in the case of the building of more than 14.5 (fourteen and half) metres in height and one staircase shall have external facing considering fire and disaster management requirement;
Provided that in case of buildings having the area of each floor exceeding 400 sqm but height less than 14.5 (fourteen and half) metres the number of staircases shall also be at least 2(two).
Tripura Gazette, Extraordinary Issue, December 2, 2022 A. D.
Provided further that:-
(a) Provision of lift shall be mandatory for the residential buildings of G+4 or above and for the residential buildings of G+6 or above there shall be provision for minimum two lifts and two staircases.
(b) Provision of lift shall be mandatory for the buildings other than residential of G+3 or above and for the buildings other than residential of G+5 or above there shall be provision for minimum two lifts and two stair cases.
(c) For the buildings having facade length greater than 30 m in either of the sides (length/breadth), one additional staircase & lift shall be provided for every additional 15 m or part facade length thereof.
(d) There shall be provision of at least one fireman-lift out of lifts provided in the following provision (a), (b) & (c) above with access to the terrace floor in all buildings.
In the principal rules, after rule 112, the following rule shall be added, namely :-
"113. Provisions for Landscaping:
(1) Following table shall be followed for minimum requirement of Plantation and landscaping area depending on the plot size:
Plot size(in square meter)
Minimum number of trees required to be planted
Minimum space to be kept for landscaping
Upto 150
Nil
Nil
Above 150 upto 500
One Evergreen tree* for every 100 square meter plot area or part thereof beyond 150 square meter and to be planted within the setback (open space) of the plot.
1.0 percent of plot area
Above 500 upto 20,000
One Evergreen tree* for every 200 square meter plot area or part thereof and to be planted within the setback (open space) of the plot.
2.5 percent of plot area
Above 20,000 upto 50,000
One Evergreen tree* for every 200 square meter plot area or part thereof and to be planted within the setback (open space) of the plot.
5.0 percent of plot area
Above 50,000
One Evergreen tree* for every 200 square
7.5 percent of plot area
Tripura Gazette, Extraordinary Issue, December 2, 2022 A. D.
meter plot area or part thereof and to be planted within the setback (open space) of the plot.
" Evergreen Tree - Tree that remains green for nost part of the year and sheds leave slowly throughout the year, having height more than 2.0 meter, with a well distinguished trunk.
(2) The minimum height of plantation of sapling should be 2.0 meter at the time of occupancy.
(3) Compen satory Plantation for felled / tran splarnted trees must be in the ratio of 1:3 within the premises / plot under consideration."
By order of the Governor,
(Shri Abhchek Singh, IAS) Secretary to the Government of Tripura
Printed at the Tripura Government Press,
No.95
Registered No. N. E. 930.
TRIPURA
HOS
GAZETTE
Extraordinary Issue
Agartala, Friday, January 17, 2025 A. D., Pausa 27, 1946 S. E.
PART--I-- Orders and Notifications by the Government of Tripura, The High Court, Government Treasury etc.
GOVERNMENT OF TRIPURA URBAN DEVELOPMENT DEPARTMENT
No.F.1(23)-TUDA/ESTT/2024/66
Dated, Agartala, the 15th January, 2025.
In exercise of the powers conferredby Section 118 read withSection 274of the Tripura Municipal Act, 1994the State Government herebymakes the following Rulesto amend the Tripura BuildingRules2017namely:
1Shorttitle andcommencement:-
(i) These may be called the “Tripura Building (Fourth Amendment) Rules,2024";
(ii) They shall come into force on the date oftheir publication in the TripuraGazette.
2.AmendmenttoRule 50:
In the Tripura Building Rules,2017 (hereinafter referred to as the PrincipalRules), for sub-clause (a) ofclause(6) of.Rule50, the following shallbesubstituted namely:-
"(6a)For a buildingexceeding 14.5(fourteen and half) meters in height, the FloorArea Ratio(FAR)shallbe3;
Provided that, the applicant may get the Floor Area Ratio(FAR) increased from the authority competent to approve it,on payment of a fee for additionalFloor AreaRatio(FAR)beyond 3upto 5, at such rates as determined by the authority competent to approve subject to minimum as may be determined byState Government from time to time.
Tripura Gazette, Extraordinary Issue, January 17, 2025 A. D.
Provided further that, for relaxation of Floor Area Ratio(FAR) beyond5, approvalof state government shall be necessaryand on payment of a fee for additionalFloor Area Ratio(FAR) beyond 5,at such rates as may be determinedbyStateGovernment from time totime.
Provided further that, The base Floor Area Ratio(FAR) in case of commercial buildings inmunicipaland development areas shall be 5 and the base FARin Central Business Districts(CBDs)and transitoriented development( TOD)corridorsshallbe 5+2."
By order of the Governor,