Provisions in the following guidelines shall apply :
-
"Guidelines and Space Standards for Barrier Free Built Environment for Disabled and Elderly Persons", (1998), Central Public Works Department, GoI.
-
"Manual on Barrier Free Environment", (2002), O/o the Chief Commissioner for Persons with Disabilities, Ministry of Urban Development, GoI.
-
"National Building Code", (2005), Bureau of Indian Standards.
-
“National Policy for Persons with Disabilities”, (2006), Ministry of Social Justice and Empowerment, GoI.
-
"Harmonized Guidelines and Space Standards for Barrier Free Built Environment for Persons with Disabilities and Elderly Persons", (Draft 2014), Ministry of Urban Development, GoI.
(3) Types of buildings to adopt barrier free guidelines
(a) Buildings to be designed for Ambulant Disabled People
Higher Secondary School, Conference Hall, Dance Halls, Youth Centers, Youth Clubs, Sport Centers, Sport Pavilions, Boar Club Houses, Ice Rinks, Bowling Centers, Swimming Pools, Police Stations, Law Courts, Courts Houses, Sport Stadiums, Theaters, Concrete Halls, Cinemas, Auditoria, Small Officers (the maximum plinth area 1400 sq.mt.) Snack Bars, Cafes and banqueting rooms (for capacity above 50 dinners).
a. In sport stadiums provisions shall be made for non-ambulant spectators(small wheel-chair).
b. @ 1:1000 up to 10,000 spectators and @ 1:2000 for spectators above 10,000.
c. In Theaters, Concert Halls, Cinemas and Auditoria provisions shall be made for non-ambulant spectators (Small Wheel Chairs) @ 1/250 up to 1000 spectators and 1/5000 for spectators above 1000.
(b) Buildings to be designed for Non-Ambulant Disabled People.
Schools for differently abled and all other buildings and along with Botanical gardens, Religious Buildings, Elderly People Clubs, Village Halls, Day Centers, Junior Training Centers, Post Offices, Banks, Dispensaries, Railway Stations, Shops, Super Markets, and Departmental Stores.
Note: Large wheel chair criteria shall be applicable on ground floors of the following building, post offices, banks, dispensaries, railway station, shops, supermarkets, and departmental stores.
(c) Buildings to be designed for Non-Ambulant People (Using small wheel chairs)
Public lavatories in Tourist Sports, Clubs Motels, Professional and Scientific Institution, Museum, Art Galleries, Public Libraries, Laborites, Universities, College for further Education, Teachers Training Colleges, Technical Colleges, Exhibition Halls, Dentist Surgeries, Administrative Department of the Hospitals, Service Stations, Car Parking, Buildings, Airports Terminals, Bus Terminals, Factories, Employing differently abled for sedentary works, Large Offices, (with plinth area abode 1400 sq.mt.), Tax Offices, Passport Offices, Pension Offices, and Labour Offices, Cafes, Banqueting Rooms and Snack Bars (For capacity above 100 dinners).
Level of the roads, access paths and parking areas shall be described in the plan along with specification of the materials.
(i) Access Path / Walk Way
Access path from plot entry and surface parking to building entrance shall be minimum of 1800 mm wide having even surface without any steps. Slope, if any, shall not have gradient greater than 5%. Selection of floor material shall be made suitably to attract or to guide visually impaired persons (limited to coloured floor material whose colour and brightness is conspicuously different from that of the surrounding floor material or the material that emits different sound to guide visually impaired persons; hereinafter referred “o” as “guiding floor material”. Finishes shall have a non-slip surface with a texture traversable by a wheel chair. Kerbs wherever provided should blend to a common level.