(1) No sub-division of any plot within the ULB area shall be undertaken without the prior approval of the Local Bodies.
(2) Generally –
(a) plot to be subdivided shall be termed as mother plot;
(b) Sub-division shall not be allowed if the mother plot abuts a means of access having a width of less than 3.50 metres for plains;
(c) every individual plot obtained by sub-division of the mother plot shall abut a means of access having width of not less than 3.50 metres;
(d) the junctions of means of access within the mother plot shall be provided with splayed corners measuring not less than 2.50 metres on each side;
(e) these rules shall not apply to a scheme for Economically Weaker Section and Low Income Group Housing approved by the Government;
(f) sub-divisions may be allowed on the condition that the following facilities shall be provided by the owner at his own cost to the satisfaction of the Local Bodies;
i. drainage facilities with pucca drain ensuing drainage of each individual plot and of the means of access and passages leading to existing public drain or natural drainage channels;
ii. all weather means of access and related protective works, if necessary along with street lighting;
iii. street and passages along with street lighting;
iv. sanitary facilities including garbage disposal facilities;
v. water supply facilities;
(g) no permission for sub-division of a plot of land shall be granted unless each sub-divided plot is at least 100 Sq. metres in area for residential purposes and 40 sq. meters for other than residential purposes;
(h) no subdivision of a plot shall be granted unless a detailed layout plan of the area proposed to be sub-divided is submitted before the ULB duly integrating the site layout plan with the general use of the land in the adjoining areas.
The existing street pattern as also the other physical infrastructures facilities like drainage, sewerage, water supply, electricity supply with location of high tension or low tension electric line with poles axe also required to be shown.
(3) The maximum permissible length for the means of access shall be as given in the following table;
Maximum length of the means of access
| Width of means of access. | For means of access closed at one end. | For means of access open to street at both ends. |
|---|---|---|
| (1) 3.50 metres and above but not more than 7.00 metres. | 25.00 metres. | 75.00 metres |
| (ii) above 7.00 metres but not more than 10.00 metres. | 50.00 metres. | 150.00 metres |
| (iii)above 10.00 metres. | No restriction. | No restriction |
(4) For mother plot measuring more than 5000 Sq. metres in area sub-division may be allowed, provided 8%(eight percent) the total area of the mother plot is developed as public open space. The width of each such open space shall not be less than 10.00 metres and each such open space shall abut a street
having a width of not less than 7.00 metres. The minimum area of each such open space is one parcel shall be 400 Square metres. This open space shall be in addition to the land required for providing the means of access to the individual plots obtained by subdivision of mother plot.
(5) For mother plots measuring more than 25,000.00 sq. metres in area, subdivision may be allowed, provided seven percent of the total area of the mother plot reserved for facilities like school, health centre, market, police outpost, milk booth, post office, power sub-station, transport terminal, water treatment plant, sewerage treatment plant and the like. Such land shall abut a street having a width of not less than 10.00 metres in addition to the land necessary for means of access and for open spaces mentioned in sub-rule(3).
10 A. Amalgamation of land
(1) Amalgamation of plots within the ULB area shall be allowed with prior approval of the ULB followed by a Registered Agreement.
(2) Amalgarnated plot(s) should satisfy the criteria in Rule 4(1).
(3) Amalgamated plot should be considered as a unit for application of relevant Rules laid down in this Rule.
(4) Building on amalgamated plot should be constructed at a time for full plinth area otherwise approved building plan will be treated as cancelled.