55 Plinth.-
(1) The plinth or any part of a building or any accessory building shall be so located with respect to the crest of the road level that adequate drainage of the site, in such situations, the stilted portion should be suitably stiffened to resist design earthquake forces assured and it shall in no case be at a height less than 60 centimeters.
Provisions shall have to be followed as per IS Guide listed in Annexure. Suitably add provisions for "Low income housing (plinth max 40 Sq. meters) as per IS: 8888-1993 Guide for requirements for low-income housing".
(2) Every inner courtyard shall be raised at least 15 centimeters above the level of the center of the nearest street and shall be satisfactorily drained.
(3) In case of buildings having parking provision at ground floor, the plinth height in no case is at a height less than 15 centimeters.
56 Habitable Room. –
(1) No habitable room shall have an area less than 9.50 sq. meters having a minimum width of 2.40 meters, where there is only one room. In case of more than one room, one of these rooms shall be not less than 9.50 sq. meters with a width of 2.40 meters at the minimum and the others shall not be less than 7.50 sq. meters in area with a minimum width of 2.10 meters.
(2) No habitable room shall have, a height of less than 2.75 meters measures from the surface of the floor to the lowest point of the ceiling or the underside of any slab:
Provided that in the case of any centrally air-conditioned building, the height of any habitable room shall not be less than 2.4 meters measured from the surface of the floor to the underside of any slab or false ceiling, as the case may be :
Provided farther that the height from the surface of the floor up to the beam shall not be less than 2.4 meters;
Provided also that in the case of any pitched roof the average height shall not be less than 2.75 meters and the minimum height at caves level shall be 2.1 meters.
(3) All rooms in any buildings irrespective of their use group, utilized for human habitation shall conform to sub-rules (1), (2) and (3)
(4) Any room to be used as retail shop shall have a minimum clear height of 2.3 meters measured from floor to bottom of the ceiling or beam, whichever is lower;
57 Roof.-
(1) The roof of a building shall be so constructed or framed as to permit effectual drainage of the rain water there from by means of sufficient rain-water pipes of adequate size, wherever required, and so arranged, joined and fixed as to ensure that the rainwater is carried away from the building without causing dampness in any part of the walls or foundations of the building or those of an adjacent building.
(2) The ULB may require rain-water pipes to be connected to a drain or sewer through a covered channel formed beneath any street to connect the rain-water pipe to a road gutter or any other approved device.
(3) Rain-water pipes shall be affixed to the outside of the walls of the buildings in recesses or chases cut or formed in such walls or in such other manner as may be approved by the ULB.
(4) Every terrace on the top most storey of any building shall have a common access and shall not be sub-divided.
58 Kitchen. –
(1) No kitchen shall have a floor area of less than 4.5 sq. meters and width of less than 1.8 meters:
Provided that if any kitchen is to be used for eating purposes also, such shall not be less than 9.5 sq. meters and the width shall not be less than 2.4 meters.
(2) No kitchen shall have a height less than 2.5 meters measured from the surface of a floor to the lowest point in the ceiling or the underside of any slab except from the portion to accommodate any floor or any upper floor.
(3) Every room to be used as kitchen shall have –
(a) unless separately provided with any pantry meant for the washing of kitchen utensils which shall land directly or through a sink to grated and trapped connection to waste pipe;
(b) an impermeable floor;
(c) a window of not less than 1 sq. meter in area opening directly to an interior or exterior open space, or into any shaft;
(d) a flue, if necessary;
(e) a refuse chute for discharge of solid wastes, in case of any building exceeding 18.0(eighteen) meters in height.
59 Pantry.-
(1) No pantry shall have a floor area of less than 3 sq. meters and a width of less than 1.4 meters.
(2) Every pantry shall have -
(a) a means of the washing kitchen utensils, if not provided in the kitchen, which shall lead directly or through a sink to grated and trapped connection to any waste pipe;
(b) an impermeable floor.
60 Bath room and water closet.-
(1) No bathroom shall have a floor area of less than 1.8 sq. meters, with a width of less than a1.2 meters and a height less than 2.2 meters measured from the surface of a floor to the lowest point of the ceiling or the underside of any slab:
Provided that if it is combined bathroom and a water closet such floor area shall not be less than 2.6 sq. meters.
(2) No water closet shall have a floor area of less than 1.1 sq. meters and a width less than 0.9 meter.
(3) Notwithstanding the provisions of sub-rule (1) or sub-rule(2), the case of any building referred to in rule 54, -
(a) an independent bathroom may have a floor area of 1.45 sq. meters;
(b) a combined bathroom and water closet may have a floor area of 2.0 sq. meters, with a minimum width of 1.1 meters.
(4) Every bathroom or water closet shall –
(a) be so situated that at least one of its walls shall open to an interior or exterior open space or shaft and shall have an interior or exterior open space or shaft and shall have an opening in the form of window or ventilator or lurver not less than 0.37 sq. meter in area;
(b) not be directly over any room other than a latrine or water closet or a washing place or a bathroom or a terrace unless it has a water tight floor;
(c) have the platform or set made of water tight non-absorbent materials;
(d) be enclosed by walls or partitions and the surface of every such wall or partition shall be finished with smooth impervious material to a height of not less than 1 meter above the floor of such room;
(e) be provided with a door completely closing the entrance to it; and
(f) be provided with an impervious floor covering with an impervious floor covering sloping towards any drain with a suitable grade and not towards any veranda or other room.
(5) No room containing any water closet shall be used for any purpose except, as a lavatory and no such room shall open directly into any kitchen or cooking space or pantry by a door, window or other opening.
61 Loft.-
(1) A loft may be permitted in buildings of all use groups.
(2) The area of any such loft shall be restricted to 25 percent of the area of the floor or any room other than inhabited room, provided that 100 percent of the area may be covered over any corridor.
(3) Maximum height between any loft and ceiling shall be 1.20 meters and the clear height below the loft shall not be less than 2.10 meters.
62 Ledge or tand. -
(1) A ledge or tand in a habitable room shall not cover more than 15 percent of the floor on which it is constructed and shall not interfere with the ventilation of the room under any circumstances.
(2) The ledge shall be provided at a minimum height of 2.1 meters from floor level.
(4) The maximum width of any ledge or tand shall be 0.60 meter.
63 Mezzanine floor. -
(1) A mezzanine floor may be permitted only between the ground floor and first floor of any building.
(2) A mezzanine floor may be permitted over a habitable room provided that –
(a) it conforms to any standard for a habitable room as regards lighting and ventilation;
(b) it is so constructed as not to interfere under any circumstances with the ventilation;
(c) such mezzanine floor is not subdivided into smaller compartments;
(d) such mezzanine floor or part of it shall not be used as kitchen; and
(e) in no case a mezzanine floor shall be subdivided so as to make it liable to be converted into unventilated compartments.
(3) An area up to 25 percent of the covered area on the ground floor shall be allowed.
(5) The height of any mezzanine floor shall not be less than 2.1 meters.
64 Store room:-
No store room in any residential building shall have a floor area less than 1.5 sq. meters and a height of less than 2.1 meters.
65 Garage. -
(1) No garage for cars shall be less than 2.5 meters x 5 meters.
(2) The minimum head room in a garage shall be 2.1 meters.
(3) The size of any garage where more than one motorcar is parked shall be calculated on the basis of the number of vehicles to be parked there.
(4) No garage for trucks shall be less than 3.75 meters x 10.00 meters with a minimum head room of 3.00 meters.
66 Basement -
(1) Subject to specifications, if any, made in this behalf under the Tripura Town and Country Planning Act, 1975, the ULB may specify any area or ward where the construction of any basement shall not be permitted.
(2) A basement may be used as –
(a) a parking space;
(b) an air-conditioning plant room or room for other machines used for any building service or for other purposes,
(c) a space for a stand by generator for power supply,
(d) a storage space for house hold or other goods of non-inflammable nature,
(e) a strong room or bank locker,
(f) a dark room,
(g) a stack room in any library, or
(h) a business building, or mercantile building (retail), or assembly building, if it is air-conditioned.
(3) Outer walls of a basement shall not extend to the exterior open spaces as required under these rules.
(4) No basement or portion thereof shall be used for residential purpose.
(5) No kitchen, bathroom or water closet shall be permitted in any basement unless the sewer levels permit the same and there is no chance of back flow and flooding of sewerage. If permitted, such kitchen, bathroom or water closet shall be placed against an external wall of the basement, which shall also be the external wall of the building and shall be adequately lighted and ventilated. Detailed plans showing arrangement for drainage including pumping system shall be submitted in such cases.
(6) Every basement shall -
(a) in every part be at least 2.4 meters in height from the floor to the underside of the roof slab or ceiling or any false roofing;
(b) have adequate arrangement so that surface drainage does not enter the basement, and have adequate arrangement for pumping out water, if necessary;
(c) have water-tight walls and floors which shall be so designed that the effect of the surrounding soil and moisture, if any, is taken into account in design and adequate damp-proofing treatment is given;
(d) have access by means of two or more ramps and a staircase, which are separated from the main and alternate staircase providing access and exit from higher level floors, the width of each ramp shall not be less than 3.5 meters and the slope shall not be steeper than 1(one) vertical to 6(six) horizontal and the distance between the ramps shall be such as may be determined by the Mayor/Chairperson of the ULB.
(e) in the case of such basement being used for a purpose as referred to in clause(g) of sub-rule(2), have sufficient numbers of access ways and exit ways so that the travel distance is not more than 15 meters;
(f) have adequate ventilation as required far any occupancy or use group under these rules :
provided that any deficiency may be met by providing adequate mechanical ventilation in the form of bowlers, exhaust fans at the, rate of one exhaust fan for every 50 sq. meters of the basement area, or by air-conditioning;
67 Chimney.-
(1) Any chimney shall conform to the requirements of the latest version of IS: 1645-1960 Code of practice for fire safety of buildings (general), chimneys, flues, flue pipes and hearths.
(2) Any chimney shall be built at least 0.9 meter above any flat roof;
Provided that the top of any chimney shall not be below the top of any adjacent wall and, in the case of a slopping roof, the top of the chimney shall not be less than 0.6 meters above the ridge thereof in which the chimney penetrates.
68 Parapet.-
A parapet wall and guardrails shall be provided on the edge of any roof terrace or balcony and it shall not be more than 1.5 meters in height.
69 Boundary wall.-
No boundary wall shall exceed 2 meter in height above the centerline of the road abutting to the plot, the solid portion of compound walls shall not exceed 1.5 meters in height. The foundation of boundary wall, below ground level, shall not encroach upon any adjacent land outside the plot area.
70 Lighting and ventilation of room.-
(1) Every habitable room, kitchen/ staircase and bathroom or water closet shall have, for the admission of light and air one or more apparatuses, such as windows, glazed doors and fan lights, opening directly to the external/air or into an open verandah.
(2) In any case where light and ventilation requirements are not met through day lighting and natural ventilation, the same shall be ensured through artificial lighting and mechanical ventilation as per the latest provisions of section 1 of Lighting and Ventilation of part VIII on Building Services of the latest edition of the National Building Code of India :
Provided that the minimum aggregate area of the openings of habitable room and kitchens, excluding doors, shall in no case be less than one-tenth of the floor area.
(3) No portion of any habitable room shall be assumed to be lighted if it is more than 7.5 meters from the opening assumed for lighting that portion.
(4) The planning, design and installation of lighting and ventilation, electrical installations and fittings, air-conditioning and heating work, a caustics, sound insulations and noise control the number, type and installations of lifts and escalators shall be carried out in accordance with the provisions of building services of the latest edition of the National Electrical Code of India :
Provided that for electrical installation in respect of any buildings the provisions of the latest edition of the National Electrical Code and Indian Electricity Rules shall apply:
Provided further that the planning, design, construction and installation of water supply, drainage, sanitation and gas supply systems shall be in accordance with the provisions of planning services of the latest edition of National Code of India.