81 Structural design -
(1) Structural design and safety
For any building under the jurisdiction of these regulations structural design/ retrofitting shall only be carried out by an empanelled Structural Engineer. Proof checking of various designs/reports shall be carried out by competent authority as per Table at clause (e) below wherever applicable.
(a) Additional provisions in building regulations/bye-laws for natural hazard prone areas
Generally, the structural design of foundations, elements of masonry, timber, plain concrete, reinforced concrete, pre-stressed concrete and structural steel shall confirm to
the provisions of Part 6: Structural Design -
Section - 1 Loads, Forces and Effects
Section - 2 Soils and Foundations,
Section - 3 Timber and Bamboos,
Section - 4 Masonry,
Section - 5 Concrete &
Section-6 Steel
Section - 7 prefabrication System, building and Mixed/ Composite Construction of National Building Code of India (NBC), taking into consideration the Indian Standards as amended upto date as given below:
For General Structural Safety
-
IS: 456:2000 "Code of Practice for Plain and Reinforced Concrete."
-
IS: 800-2007 "Code of Practice for General Construction in Steel."
-
IS: 801-1975 "Code of Practice for Use of Cold Formal Light Gauge Steel Structural Members in General Building Construction."
-
IS 875 (Part 2): 1987 Design loads (other than earthquake) for buildings and structures Part 2 Imposed Loads.
(Reference of Table 4.1- “Occupant Load” may be considered for design load)
-
IS 875 (Part 3): 1987 Design loads (other than earthquake) for buildings and structures Part 3 Wind Loads.
-
IS 875 (Part 4): 1987 Design loads (other than earthquake) for buildings and structures Part 4 Snow Loads.
-
IS 875 (Part 5): 1987 Design loads (other than earthquake) for buildings and structures Part 5 special loads and load combination.
-
IS: 883:1994 "Code of Practice for Design of Structural Timber in Building."
-
IS: 1904:1986 (R 2005) "Code of Practice for Design of Structural Safety of Buildings: Foundation"
-
IS: 1905:1987 (R 2005) “Code of Practice for Design of Structural Safety of Buildings: Masonry Walls”
-
IS 2911 (Part 1): Section 1: 2010 “Code of Practice for design and Construction of Pile Foundation Section 1
Part 1: Section 2 Bored Cast-in-situ Piles Part 1: Section 3 Driven Precast Concrete Piles Part 1: Section 4 Bored Precast Concrete Piles Part 2: Timber Piles Part 3: Under Reamed Piles Part 4: Load Test on Piles
For Cyclone/Wind Storm Protection
-
IS 875 (3): 1987 “Code of Practice for Design Loads (other than Earthquake) for Buildings and Structures, Part 3, Wind Loads”
-
Guidelines (Based on IS 875 (3)-1987) for improving the Cyclonic Resistance of Low rise houses and other building.
For Earthquake Protection
-
IS: 1893 (Part I)- 2002 “Criteria for Earthquake Resistant Design of Structures (Fifth Revision)”
-
IS: 13920-1993 “Ductile Detailing of Reinforced Concrete Structures subjected to Seismic Forces – Code of Practice”
-
IS: 4326-2013 “Earthquake Resistant Design and Construction of Buildings – Code of Practice (Second Revision)”
-
IS: 13828-1993 “Improving Earthquake Resistance of Low Strength Masonry Buildings – Guidelines”
-
IS: 13827-1993 “Improving Earthquake Resistance of Earthen Buildings—Guidelines”
-
IS: 13935-2009 "Seismic Evaluation, Repair and Seismic Strengthening of Buildings – Guidelines"
For Protection of Landslide Hazard
-
IS 14458 (Part 1): 1998 Guidelines for retaining wall for hill area: Part 1 Selection of type of wall.
-
IS 14458 (Part 2): 1997 Guidelines for retaining wall for hill area: Part 2 Design of retaining/breast walls.
-
IS 14458 (Part 3): 1998 Guidelines for retaining wall for hill area: Part 3 Construction of dry stone walls.
-
IS 14496 (Part 2): 1998 Guidelines for preparation of landslide -- Hazard zonation maps in mountainous terrains: Part 2 Macro-Zonation.
Note: Whenever an Indian Standard including those referred in the National
Building Code or the National Building Code is referred, the latest revision of the same shall be followed except specific criteria if any, mentioned above against that code.
(b) Structural Design Basis Report (SDBR)
In compliance of the design with the above Indian Standard, the empanelled Structural Engineer will submit a structural design basis report in the Proforma attached herewith covering the essential safety requirements specified in the standard.
The "Structural Design Basis Report (SDBR)" consists of four parts -
Part 1: General Information / Data
Part 2: Load bearing Masonry Buildings
Part 3: Reinforced Concrete Buildings
Part 4: Steel Buildings
i) Drawings and Documents to be submitted for approval of appropriate authorities shall include SDBR as detailed bow:
Part 1: Completed
Part 2: (if applicable) - completed
Part 3: (if applicable) – undertaking that completed Part 3 will be submitted before commencement of construction.
Part 4: (if applicable) - undertaking that completed Part 4 will be submitted before commencement of construction.
ii) SDBR as detailed below shall be submitted to the appropriate authority as soon as design of foundation is completed, but not later than one month prior to commencement of construction.
Part 1: Completed
Part 2: Part 3: Part 4 (if applicable) Completed
(c) Seismic strengthening /retrofitting
Prior to seismic strengthening /retrofitting of any existing structure, evaluation of the existing structure as regards structural vulnerability in the specified wind/seismic hazard zone shall be carried out. If as per the evaluation the seismic resistance is assessed to be less than the specified minimum seismic resistance as given in the note below, action will be initiated to carry out the upgrading of the seismic resistance of the building as per applicable standard guidelines.
Note:
-
For masonry building reference shall be made to IS 4326 and IS 13935
-
For concrete buildings and structures reference shall be made to IS 15988: 2013 Seismic evaluation and strengthening of existing RCC buildings.
(d) Building with Soft Storey
In case of buildings with a flexible storeys, such as the ground storey consisting of open spaces for parking that is “Still building” or any other storey with open halls, special arrangements are to be made to increase the lateral strength and stiffness of the soft/open storey such as Steel bracing/ Shear walls /Brick infills between columns.
Dynamic analysis of building is to be carried out including the strength and stiffness effects of infills and inelastic deformations in the members, particularly; those in the soft storey and the structural members are to be designed accordingly. Alternatively, the following design criteria
are to be adopted after carrying out the earthquake analysis, neglecting the effect of infill walls in other storeys:
a. The column and beams of the soft storey shall be designed for 2.5 times the storey shears and moments, calculated under seismic loads specified in the other relevant clauses: or
b. Besides the columns designed and detailed for the calculated storey shears and moments, shears walls shall be placed symmetrically in both directions of the building as far away from the centre of the building as feasible; to be designed exclusively for 1.5 times the lateral storey shear force calculated as before. For details of design and provisions, IS 1893, Part 1 shall be referred.
(e) Review of structural design
i) The Competent Authority shall review and suggest addendum to the certificate or a new certificate in case of subsequent changes in structural design.
iii) Table below gives requirements of empanelled Structural Engineer for different seismic zones namely III, IV and V and for structures of different complexities.
iv) In seismic Zone II, buildings & structures greater than 40m in height will require proof checking as per details at Sl. No. 3 of Table below.
Proof Checking Requirements for Structural Design
| Sl. No. | Type of Structure | Submission from empanelled Structural Engineer | To be Proof Checked |
| 1 | Load Bearing Buildings upto three storeys | SDBR* | Not to be checked |
| 2 | Building upto seven storeys (R.C.C/Steel framed structure) | SDBR | To be checked |
| Preliminary design | To be checked | ||
| 3 | Building greater than seven storey (R.C.C/Steel framed structure) | SDBR | To be checked |
| Preliminary design | To be checked | ||
| Detailed structural design and structural drawings | To be checked | ||
| 4 | Special Structures | SDBR | To be checked |
| Preliminary design | To be checked | ||
| Detailed structural design and structural drawings | To be checked |
* SDBR – Structural Design Basis Report
Notes:
-
Table 4.1 may be referred for Occupant Load Live load for different building types.
-
At the preliminary proposal stage of a project, the objective is to undertake feasibility study comparison of a number of possible alternatives of structural schemes and determine the most cost effective one, detailed structural calculations are not necessary for each alternative scheme. However, it is conservative assumption it is possible to derive simplified calculations for analysis and design. This is called "Preliminary or appropriate analysis, and design"
After the most cost effective scheme is selected and signed-off by the Client, the detailed calculations are performed on the selected scheme to determine the precise structural members and composition (size, dimension and stress behavior), and this is called the “Detailed structural design”.
In the aforesaid, the design of structural members is typically assumed to account for all the stress loads identified from section xx to be applicable in the given project
- Special structure means large span structures as stadium, assembly halls, or tall structures such as water tanks. TV tower, chimney, etc.
(f) Certification regarding structural safety in design Empanelled Structural Engineer shall give a certificate of structural safety of design as per standard proforma.
(g) Constructional safety
(i) Supervision All construction except load bearing building upto 3 storeys shall be carried out under supervision under empanelled Construction Engineer for various seismic zones.
(ii) Certification of structural safety in construction Empanelled Construction Engineer shall give a certificate of structural safety of construction at the time of completion.
(h) Quality control and inspection All material and workmanship shall be of good quality conforming generally to accepted standards of Public Works Department and Indian standard specification and codes as included in part-V Building Materials and Part-VII Construction practices and safety of National Building Code Of India.
(i) Inspection All the construction for high-rise buildings higher than seven storeys, public building and special structures shall be carried out under quality inspection program prepared and implemented under the empanelled Quality Auditor in seismic zones.
(ii) Certification of safety in quality of construction Empanelled Quality Auditor shall give a certificate of quality control. Quality Inspection Programme to be carried on the site shall be worked out by empanelled Quality Auditor in consultation with the owner, builder.
Note: Section (g) and (h) shall not be applicable government buildings that are designed and constructed under the supervision of in house architect/ engineer.
(I) Control and signage & outdoor display structures, cellphone towers and telephone towers.
Following provisions shall apply for telecommunication infrastructure-
(2) Structural requirements of low income housing
Notwithstanding anything contained herein, for the structural safety and services for development of low income housing, the relevant provision of applicable IS: 8888 part I shall be enforced along with Annex C of part 3 NBC.
(3) Alternative Materials, Methods of Design and Construction and Tests
The provision of the Bye-Laws are not intended to prevent the use of any material or method of design or construction not specifically prescribed by the bye-law provided any such alternative has been approved. The building materials approved by B.I.S. or any statutory body will form part of the approved building material and technology as part of the Bye-Laws.
The Authority shall promote and encourage use of Pre-fabricated factory made building components for medium to large scale projects that have significant impact. The use of ready mix concrete (RMC) shall also be encouraged for in-situ concrete constructions.
(4) While submitting the plan for Ground Floor / Basement floor of the building, the plan should clearly specify the height of the building for which foundation of the building has been designed and all relevant provisions of the Rules related to that designed height of the building should be followed from the beginning i.e. from Ground Floor / Basement floor of the building.
82 Quality of materials and workmanship.-
All materials and workmanship shall be of good quality conforming generally to the accepted standards of the Public Works Department of the Government of Tripura or Indian Standard Specifications as indicated in part V on Building Materials and part VII on Constructional practices and safety of the latest edition of the National Building code of India.
83 Alternative materials, method of design and construction.-
The ULB may approve any alternative material or method of design or construction if the competent authority of the ULB is satisfied that such alternative is satisfactory and conforms to the provisions of the relevant parts of the National Building Code of India regarding materials, method of design and construction and that materials, methods of design or work are for the purpose intended equivalent to those specified in the code in quality, strength, compatibility, effectiveness, fire and water resistance, durability and safety.
84 Tests.-
Whenever there is insufficient evidence of compliance with the provisions of these rules or there is evident that any claim for alternative materials, or design, the ULB may require tests to be made sufficiently in advance or require performance certificate from a body authorized by a state or central government, as proof of compliance and such tests shall be made at the expenses of the owner and in such manner as the ULB may direct.