5.2.1 General
There should be at least one water tap and arrangement for drainage in the vicinity of each water-closet or group of water-closet in all the buildings.
5.2.2 Each family dwelling unit on premises (abutting on a sewer or with a private sewage disposal system) shall have, at least, one water-closet and one kitchen type sink. A bath or shower shall also be installed to meet the basic requirements of sanitation and personal hygiene.
5.2.3 All other structures for human occupancy or use on premises, abutting on a sewer or with a private sewage-disposal system, shall have adequate sanitary facilities, but in no case less than one water-closet and one other fixture for cleaning purposes.
5.2.4 For Residences
5.2.4.1 Dwelling with individual convenience shall have at least the following fitments:
a) One bathroom provided with a tap and a floor trap;
b) One water-closet with flushing apparatus with an ablution tap; and
c) One tap with a floor trap or a sink in kitchen or wash place.
5.2.4.1.1 Where only one water-closet is provided in a dwelling, the bath and water-closet desirably shall be separately accommodated.
NOTE — Water-closets, unless indicated otherwise, shall be of Indian style (squatting type).
5.2.4.2 Dwellings without individual conveniences shall have the following fitments:
a) One water tap with floor trap in each tenement,
b) One water-closet with flushing apparatus and one ablution tap bath for every two tenements, and
c) One bath with water tap and floor trap for every two tenements.
5.2.5 For Buildings Other than Residences
5.2.5.1 The requirements for fitments for drainage and sanitation in the case of buildings other than residences shall be in accordance with Table 9 to Table 22. The following shall be, in addition, taken into consideration:
a) The figures shown are based upon one (1) fixture being the minimum required for the number of persons indicated or part thereof.
b) Building categories not included in the tables shall be considered separately by the Authority.
c) Drinking fountains shall not be installed in the toilets.
d) Where there is the danger of exposure to skin contamination with poisonous, infectious or irritating material, washbasin with eye wash jet and an emergency shower located in an area accessible at all times with the passage/ right of way suitable for access to a wheel chair, shall be provided.
e) When applying the provision of these tables for providing the number of fixtures, consideration shall be given to the accessibility of the fixtures. Using purely numerical basis may not result in an installation suited to the need of a specific building. For example, schools should be provided with toilet facilities on each floor. Similarly toilet facilities shall be provided for temporary workmen employed in any establishment according to the needs; and in any case one WC and one washbasin shall be provided.
f) All buildings used for human habitation for dwelling, work, occupation, medical care or
Table 9 Office Buildings
(Clause 5.2.5.1)
| Sl No | Fixtures | Public Toilets | Staff Toilets | ||
| Male(3) | Females(4) | Male(5) | Females(6) | ||
| i) Executive Rooms and Conference Halls in Office Buildings | |||||
| Toilet suite comprising one WC, one washbasin (with optional shower stall if building is used round the clock at user's option)Pantry optional as per user requirement | Unit could be common for Male/Female or separate depending on the number of user of each facility | For individual officer rooms | |||
| ii) Main Office Toilets for Staff and Visitors | |||||
| a) Water-closets | 1 per 25 | 1 per 15 | 1 per 25 | 1 per 15 | |
| b) Ablution tap with each water-closet | ← | 1 in each water-closet | → | ||
| c) Urinals | Nil up to 61 for 7-202 for 21-453 for 46-704 for 71-100 | — | Nil up to 6 | — | |
| Add @ 3% for101-200 | |||||
| Add @ 2.5 %Over 200 | |||||
| d) Washbasins | 1 per 25 | 1 per 25 | 1 per 25 | 1 per 25 | |
| e) Drinking water fountain | 1 per 100 | 1 per 100 | 1 per 100 | 1 per 100 | |
| f) Cleaner's sink | ← | 1 per floor | → | ||
| Table 10 Factories(Clause 5.2.5.1) | |||||
| Sl No | Fixtures | Offices/Visitors | Workers | ||
| Male(3) | Female(4) | Male(5) | Female(6) | ||
| i) | Water-closets(Workers & Staff) | 1 for up to 25 | 1 for up to 15 | 1 for up to 15 | 1 for up to 12 |
| 2 for 16-35 | 2 for 16-25 | 2 for 16-35 | 2 for 13-25 | ||
| 3 for 36-65 | 3 for 26-40 | 3 for 36-65 | 3 for 26-40 | ||
| 4 for 66-100 | 4 for 41-57 | 4 for 66-100 | 4 for 41-57 | ||
| 5 for 58-77 | 5 for 58-77 | ||||
| 6 for 78-100 | 6 for 78-100 | ||||
| For persons 101-200 add | 3% | 5% | 3% | 5% | |
| For persons over 200 add | 2.5% | 4% | 2.50% | 4% | |
| ii) | Ablution tap | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet |
| iii) | Urinals | Nil up to 6 | — | Nil up to 6 | — |
| 1 for 7-20 | 1 for 7-20 | ||||
| 2 for 21-45 | 2 for 21-45 | ||||
| 3 for 46-70 | 3 for 46-70 | ||||
| 4 for 71-100 | 4 for 71-100 | ||||
| For persons 101-200 add | 3% | 3% | |||
| For persons over 200 add | 2.50% | 2.50% | |||
| iv) | Washbasins | 1 per 25 or part thereof | 1 per 25 or part thereof | 1 per 25 or part thereof | 1 per 25 or part thereof |
| Washbasins in rows or troughs and taps spaced 750 mm c/c | |||||
| v) | Drinking water fountain | 1 per every 100 or part thereof with minimum one on each floor | 1 per every 100 or part thereof with minimum one on each floor | ||
| vi) | Cleaner's sink | 1 on each floor | 1 on each floor | 1 on each floor | 1 on each floor |
| vii) | Showers/Bathing rooms | ||||
Table 11 Cinema, Multiplex Cinema, Concerts and Convention Halls, Theatres
(Clause 5.2.5.1)
| Sl No. | Fixtures | Public | Staff | ||
| Male(3) | Female(4) | Male(5) | Female(6) | ||
| i) | Water-closets | 1 per 100 up to 400Over 400 add at 1 per 250 or part thereof | 3 per 100 up to 200Over 200 add at 2 per 100 or part thereof | 1 for up to 15 | 1 for up to 12 |
| ii) | Ablution tap | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet | 1 in each water-closet |
| 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals | |||||
| iii) | Urinals | 1 per 25 or part thereof | — | Nil up to 61 for 7-202 for 21-45 | — |
| iv) | Washbasins | 1 per 200 or part thereof | 1 for up to 152 for 16-35 | 1 for up to 122 for 13-25 | |
| v) | Drinking water fountain | 1 per 100 persons or part thereof | |||
| vi) | Cleaner's sink | 1 per floor | |||
| vii) | Showers/Bathing rooms | As per trade requirements | |||
| NOTES | |||||
| 1 Some WCs may be European style if desired. | |||||
| 2 Male population may be assumed as two-third and female population as one-third. | |||||
| Sl No. | Fixtures | Public | Staff | ||
| Male(3) | Female(4) | Male(5) | Female(6) | ||
| i) | Water-closets | 1 per 200 up to 400Over 400 add at 1 per 250 or part thereof | 1 per 100 up to 200Over 200 add at 1 per 150 or part thereof | 1 for up to 152 for 16-35 | 1 for up to 122 for 13-25 |
| ii) | Ablution tap | One in each water-closet | One in each water-closet | One in each water-closet | One in each water-closet |
| 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals | |||||
| iii) | Urinals | 1 per 50 | — | Nil up to 61 per 7 to 202 per 21-45 | — |
| iv) | Washbasins | 1 for every 200 or part thereof. For over 400, add at 1 per 250 persons or part thereof | 1 for every 200 or part thereof. For over 200, add at 1 per 150 persons or part thereof | 1 for up to 152 for 16-35 | 1 for up to 122 for 13-25 |
| v) | Drinking water fountain | ← | 1 per 100 persons or part thereof | → | |
| vi) | Cleaner's sink | ← | 1 per floor, Min | → | |
| vii) | Showers/Bathing rooms | ← | As per requirements | → | |
| NOTES | |||||
| 1 Some WC's may be European style if desired. | |||||
| 2 Male population may be assumed as two-third and female population as one-third. | |||||
| Sl No. | Fixtures | Patient Toilets | Staff Toilets | ||
| Male(3) | Female(4) | Male(5) | Female(6) | ||
| i) | Toilet suite comprising one WC and one washbasin and shower stall | Private room with up to 4 patients | For individual doctor's/officer's rooms | ||
| For General Wards, Hospital Staff and Visitors | |||||
| ii) | Water-closets | 1 per 8 beds or part thereof | 1 per 8 beds or part thereof | 1 for up to 152 for 16-35 | 1 for up to 122 for 13-25 |
| iii) | Ablution tap | One in each water-closet | One in each water-closet | One in each water-closet | One in each water-closet |
| 1 water tap with draining arrangements shall be vicinity of water-closets and urinals | provided for every 50 persons or part thereof in the | ||||
| iv) | Urinals | 1 per 30 beds | — | Nil up to 61 for 7 to 202 for 21-45 | — |
| v) | Washbasins | 2 for every 30 beds or part thereof. Add 1 per additional 30 beds or part thereof | 1 for up to 152 for 16-35 | 1 for up to 122 for 13-25 | |
| vi) | Drinking water fountain | 1 per ward | 1 per 100 persons or part thereof | ||
| vii) | Cleaner's sink | 1 per ward | — | ||
| viii) | Bed pan sink | 1 per ward | — | ||
| ix) | Kitchen sink | 1 per ward | — | ||
| NOTES | |||||
| 1 | Some WC's may be European style if desired. | ||||
| 2 | Male population may be assumed as two-third and female population as one-third. | ||||
| 3 | Provision for additional and special hospital fittings where required shall be made. | ||||
| Sl No. | Fixtures | Patient Toilets | Staff Toilets | ||
| Male(3) | Female(4) | Male(5) | Female(6) | ||
| i) | Toilet suite comprising one WC and one washbasin (with optional shower stall if building used for 24 h) | For up to 4 patients | For individual doctor's/officer's rooms | ||
| ii) | Water-closets | 1 per 100 persons or part thereof | 2 per 100 persons or part thereof | 1 for up to 152 for 16-35 | 1 for up to 122 for 13-25 |
| iii) | Ablution tap | One in each water-closet | One in each water-closet | One in each water-closet | One in each water-closet |
| 1 water tap with draining arrangements shall be vicinity of water-closets and urinals | provided for every 50 persons or part thereof in the | ||||
| iv) | Urinals | 1 per 50 persons or part thereof | — | Nil up to 61 for 7 to 202 for 21-45 | — |
| v) | Washbasins | 1 per 100 persons or part thereof | 2 per 100 persons or part thereof | 1 for up to 152 for 16-35 | 1 for up to 122 for 13-25 |
| vi) | Drinking water fountain | 1 per 500 persons or part thereof | 1 per 100 persons or part thereof | ||
| NOTES | |||||
| 1 | Some WC's may be European style if desired. | ||||
| 2 | Male population may be assumed as two-third and female population as one-third. | ||||
| 3 | Provision for additional and special hospital fittings where required shall be made. | ||||
| Sl No. | Fixtures | Staff Toilets | |
| Male | Female | ||
| (1) | (2) | (3) | (4) |
| i) | Toilet suite comprising one WC and one washbasin (with optional shower stall if building used for 24 h) | For individual doctor's/officer's rooms | |
| ii) | Water-closets | 1 per 25 persons or part thereof | 1 per 15 persons or part thereof |
| iii) | Ablution tap | One in each water-closet1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals | One in each water-closet |
| iv) | Urinals | Nil up to 61 for 7 to 202 for 21-45 | — |
| v) | Washbasins | 1 per 25 persons or part thereof | 1 per 25 persons or part thereof |
| vi) | Drinking water fountain | 1 per 100 persons or part thereof | |
| vii) | Cleaner's sink | 1 per floor, Min | |
| viii) | Kitchen sink | 1 per floor, Min | |
| NOTE — Some WC's may be European style if desired. | |||
Table 16 Hospitals Staff Quarters and Nurses Homes
(Clause 5.2.5.1)
| Sl No. | Fixtures | Staff Quarters | Nurses Homes | ||
| Male(3) | Female(4) | Male(5) | Female(6) | ||
| i) | Water-closets | 1 per 4 persons or part thereof | 1 per 4 persons or part thereof | 1 per 4 persons or part thereof2 for 16-35 | 1 per 4 persons or part thereof2 for 13-25 |
| ii) | Ablution tap | One in each water-closet1 water tap with draining arrangements shall be vicinity of water-closets and urinals | One in each water-closet | One in each water-closet | One in each water-closet |
| iii) | Washbasins | 1 per 8 persons or part thereof | 1 per 8 persons or part thereof | ||
| iv) | Bath (Showers) | 1 per 4 persons or part thereof | 1 per 4 to 6 persons or part thereof | ||
| v) | Drinking water fountain | 1 per 100 persons or part thereof, minimum1 per floor | 1 per 100 persons or part thereof, minimum1 per floor | ||
| vi) | Cleaner's sink | 1 per Floor | 1 per Floor | ||
| NOTES | |||||
| 1 | Some WC's may be European style if desired. | ||||
| 2 | For independent housing units fixtures shall be provided as for residences. | ||||
| Sl No. | Fixtures | Public Rooms | Non-Residential Staff | ||
| Male(3) | Female(4) | Male(5) | Female(6) | ||
| i) | Toilet suite comprising one WC, Washbasin with Shower or a Bath tub | Individual guest rooms with attached toilets | — | ||
| Guest Rooms with Common Facilities | |||||
| ii) | Water-closets | 1 per 100 persons up to 400Over 400 add at 1 per 250 or part thereof | 2 per 100 persons up to 200Over 200 add at 1 per 100 or part thereof | 1 for up to 152 for 16-353 for 36-654 for 66-100 | 1 for up to 122 for 13-253 for 26-404 for 41-575 for 58-776 for 78-100 |
| iii) | Ablution tap | One in each water-closet | One in each water-closet | One in each water-closet | One in each water-closet |
| iv) | Urinals | 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals | |||
| 1 per 50 persons or part thereof | — | Nil up to 61 for 7 to 202 for 21-453 for 46-704 for 71-100 | — | ||
| v) | Washbasins | 1 per WC/Urinal | 1 per WC | 1 for up to 152 for 16-353 for 36-654 for 66-100 | 1 for up to 122 for 13-253 for 26-404 for 41-57 |
| vi) | Bath (Showers) | 1 per 10 persons or part thereof | — | — | |
| vii) | Cleaner's sink | 1 per 30 rooms, minimum 1 per floor | |||
| viii) | Kitchen sink | 1 per kitchen | |||
| NOTES | |||||
| 1 | Some WC's may be European style if desired. | ||||
| 2 | Male population may be assumed as two-third and female population as one-third. | ||||
| 3 | Provision for additional and special fittings where required shall be made. | ||||
| Table 18 Restaurants(Clause 5.2.5.1) | |||||
| Sl No. | Fixtures | Public Rooms | Non-Residential Staff | ||
| Male(3) | Female(4) | Male(5) | Female(6) | ||
| i) | Water-closets | 1 per 50 seats up to 200Over 200 add at 1 per 100 or part thereof | 2 per 50 seats up to 200Over 200 add at 1 per 100 or part thereof | 1 for up to 152 for 16-353 for 36-654 for 66-100 | 1 for up to 122 for 13-253 for 26-404 for 41-575 for 58-776 for 78-100 |
| ii) | Ablution tap | One in each water-closet1 water tap with draining arrangements shall be provided for every 50 persons or part thereof of water-closets and urinals | One in each water-closet | One in each water-closet | One in each water-closet |
| iii) | Urinals | 1 per 50 persons or part thereof | — | Nil up to 61 for 7 to 202 for 21-453 for 46-704 for 71-100 | — |
| iv) | Washbasins | 1 per WC | 1 per WC | 1 per WC | 1 per WC |
| v) | Cleaner's sink | 1 per each restaurant | |||
| vi) | Kitchen sink/Dish washer | 1 per kitchen | |||
| NOTES | |||||
| 1 | Some WC's may be European style if desired. | ||||
| 2 | Male population may be assumed as two-third and female population as one-third. | ||||
| 3 | Provision for additional and special fittings where required shall be made. | ||||
Table 19 Schools and Educational Institutions
(Clause 5.2.5.1)
| Sl No. | Fixtures | Nursery School | Non-Residential | Residential | ||
| Boys | Girls | Boys | Girls | |||
| (1) | (2) | (3) | (4) | (5) | (6) | (7) |
| i) | Water-closets | 1 per 15 pupils or part thereof | 1 per 40 pupils or part thereof | 1 per 25 pupils or part thereof | 1 per 8 pupils or part thereof | 1 per 6 pupils or part thereof |
| ii) | Ablution tap | One in each water-closet | One in each water-closet | One in each water-closet | One in each water-closet | One in each water-closet |
| 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals | ||||||
| iii) | Urinals | — | 1 per 20 pupils or part thereof | — | 1 per 25 pupils or part thereof | — |
| iv) | Washbasins | 1 per 15 pupils or part thereof | 1 per 60 pupils or part thereof | 1 per 40 pupils or part thereof | 1 per 8 pupils or part thereof | 1 per 6 pupils or part thereof |
| v) | Bath/Showers | 1 per 40 pupils or part thereof | — | — | 1 per 8 pupils or part thereof | 1 per 6 pupils or part thereof |
| vi) | Drinking water fountain or taps | 1 per 50 pupils or part thereof | 1 per 50 pupils or part thereof | 1 per 50 pupils or part thereof | 1 per 50 pupils or part thereof | 1 per 50 pupils or part thereof |
| vii) | Cleaner's sink | 1 per each floor | ||||
| NOTES | ||||||
| 1 Some WC's may be European style if desired. | ||||||
| 2 For teaching staff, the schedule of fixtures to be provided shall be the same as in case of office building. | ||||||
| Table 20 Hostels(Clause 5.2.5.1) | |||||||
| Sl No. | Fixtures | Resident | Non-Resident | Visitor/Common Rooms | |||
| Males(3) | Females(4) | Males(5) | Females(6) | Males(7) | Females(8) | ||
| i) | Water-closets | 1 per 8 or part thereof | 1 per 6 or part thereof | 1 for up to 152 for 16-353 for 36-654 for 66-100 | 1 for up to 122 for 13-253 for 26-404 for 41-575 for 58-776 for 78-100 | 1 per 100up to 400Over 400 add at1 per 250 | 2 per 100up to 200Over 200 add at1 per 100 |
| ii) | Ablution tap | One in each water-closet | One in each water-closet | One in each water-closet | One in each water-closet | One in each water-closet | One in each water-closet |
| 1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals | |||||||
| iii) | Urinals | 1 per 25 or part thereof | — | Nil up to 61 for 7-202 for 21-453 for 46-704 for 71-100 | — | 1 per 50 or part thereof | — |
| iv) | Washbasins | 1 per 8 persons or part thereof | 1 per 6 persons or part thereof | 1 for up to 152 for 16-353 for 36-654 for 66-100 | 1 for up to 122 for 13-253 for 26-404 for 41-575 for 58-776 for 78-100 | 1 per WC/Urinal | 1 per WC |
| v) | Bath/Showers | 1 per 8 persons or part thereof | 1 per 6 persons or part thereof | — | — | — | — |
| vi) | Cleaner's sink | 1 per each floor | |||||
| NOTE — Some WC's may be European style if desired. | |||||||
| Sl No. | Fixtures | Shop Owners | Common Toilets in Market Building | Public Toilet for Floating Population | |||
| Males(3) | Females(4) | Males(5) | Females(6) | Males(7) | Females(8) | ||
| i) | Water-closets | 1 per 8 or part thereof | 1 for up to 152 for 16-353 for 36-654 for 66-100 | 1 for up to 122 for 13-253 for 26-404 for 41-575 for 58-776 for 78-100 | 1 per 50,(Minimum 2) | 1 per 50,(Minimum 2) | |
| ii) | Ablution tap | One in each water-closet | One in each water-closet | One in each water-closet | One in each water-closet | One in each water-closet | One in each water-closet |
| 1 water tap with draining arrangements shall be provided in receiving/sale area of each shop and for every 50 persons or part thereof in the vicinity of water-closets and urinals | |||||||
| iii) | Urinals | — | — | Nil up to 61 for 7-202 for 21-453 for 46-704 for 71-100 | — | 1 per 50 | — |
| iv) | Washbasins | 1 per 8 percent or part thereof | 1 for up to 152 for 16-353 for 36-654 for 66-100 | 1 for up to 122 for 13-253 for 26-404 for 41-57 | — | — | |
| v) | Bath/Showers | 1 per 8 persons or part thereof | 1 per 6 persons or part thereof | — | — | 1 per 50 persons | 1 per 50 persons |
| NOTES | |||||||
| 1 Toilet facilities for individual buildings in a market should be taken same as that for office buildings.2 Common toilets in the market buildings provide facilities for persons working in shops and their regular visitors.3 Special toilet facilities for a large floating population of out of town buyers/sellers, labour, drivers of vehicles for whom special toilet (public toilets). | |||||||
Table 22 Airports and Railway Stations
(Clause 5.2.5.1)
| Sl No. | Fixtures | Junction Stations, Intermediate Stations and Bus Stations | Terminal Railway and Bus Stations | Domestic and International Airports | |||
| Males(3) | Females(4) | Males(5) | Females(6) | Males(7) | Females(8) | ||
| i) | Water-closets | 3 for up to 1 000Add 1 peradditional 1 000or part thereof | 4 for up to 1 000Add 1 peradditional 1 000or part thereof | 4 for up to 1 000Add 1 peradditional 1 000or part thereof | 5 for up to 1 000Add 1 peradditional 1 000or part thereof | Minimum 2For 200 5For 400 9For 600 12For 800 16For 1 000 18 | Minimum 2For 200 8For 400 15For 600 20For 800 26For 1 000 29 |
| ii) | Ablution tap | One in each water-closet1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity ofwater-closets and urinals | |||||
| iii) | Urinals | 4 for up to 1 000Add 1 peradditional 1 000 | — | 6 for up to 1 000Add 1 peradditional 1 000 | — | One in each water-closet | One in each water-closet |
| iv) | Washbasins | 1 per WC/Urinal | 1 per WC | 1 per WC/Urinal | 1 per WC | 1 per WC/Urinal | 1 per WC |
| v) | Bath/Showers | 2 per 1 000 | 3 per 1 000 | 4 per 1 000 | |||
| vi) | Drinking water fountain or taps (in common lobby for male/female) | 2 per 1 000 or part thereof | 3 per 1 000 or part thereof | 4 per 1 000 or part thereof | |||
| vii) | Cleaner's sink | 1 per toilet compartmentwith 3 WC's | 1 per toilet compartmentwith 3 WC's | 1 per toilet compartmentwith 3 WC's | 1 per toilet compartmentwith 3 WC's | 1 per toilet compartmentwith 3 WC's | 1 per toilet compartmentwith 3 WC's |
| viii) | Toilet for Disabled | 1 per 4 000 | 1 per 4 000 | 1 per 4 000 | 1 per 4 000 | 1 per 4 000(Minimum 1) | 1 per 4 000(Minimum 1) |
| NOTES | |||||||
| 1 Some WC's may be European style if desired. | |||||||
| 2 Male population may be assumed as three-fifth and female population as two-fifth. | |||||||
any purpose detailed in the various tables, abutting a public sewer or a private sewage disposal system, shall be provided with minimum sanitary facilities as per the schedule in the tables. In case the disposal facilities are not available, they shall be provided as a part of the building design for ensuring high standards of sanitary conditions in accordance with this section.
g) Workplaces where creches are provided, they shall be provided with one WC for 10 persons or part thereof, one washbasin for 15 persons or part thereof, one kitchen sink with floor trap for preparing food/milk preparations. The sink provided shall with a drinking water tap.
h) In all types of buildings, individual toilets and pantry should be provided for executives, and for meeting/seminar/conference rooms, etc as per the user requirement.
j) Where food is consumed indoors, water stations may be provided in place of drinking water fountains.