A certificate to the effect that this report will be completed and submitted at least one month before commencement of construction shall be submitted with the application for Building Development Permission.
-
In addition to the completed report following additional information shall be submitted, at the latest, one month before commencement of construction.
2.1 Foundations.
2.1.1 In case raft foundation has been adopted indicate K value used for analysis of the raft.
2.1.2 In case pile foundations have used give full particulars of the piles, type, dia, length, capacity.
2.1.3 In case of high water table indicate system of countering water pressure, and indicate the existing water table, and that assumed to design foundations.
2.2 Idealization for earthquake analysis.
2.2.1 In case of a composite system of shear walls and rigid frames, give distribution of base shear in the two systems on the basis of analysis and that used for design of each system.
2.2.2 Indicate the idealization of frames and shear walls adopted in the analysis with the help of sketches.
2.3 Submit framing plants of each floor.
2.4 In case of basements, Indicate the system used to contain earth pressures.
[50]
| Part 4 Buildings in structural steel | |||
| 1 | Adopted method of Design | O SimpleO Semi-rigidO Rigid | IS:00;CL.3.4.4IS:800;CL.3.4.5IS:800;CL.3.4.6 |
| 2 | Design based on | O Elastic analysisO Plastic analysis | IS:00;Section-9SP:6(6) |
| 3 | Floor construction | O CompositeO Non compositeO Boarded | |
| 4 | Roof construction | O CompositeO Non-compositeO MetalO Any other | |
| 5 | Horizontal force resisting system adopted | O FramesO Braced framesO Frames and shear Walls | Note:Seismic forceAs per IS:1893 would depend on system |
| 6 | Slenderness ratios maintained | Members defined in Table 3.1, IS:800 | IS:800;CL.3.7 |
| 7 | Member of deflection limited to | Beams, Rafters Crane Girders Purlins Top of columns | IS:800;CL.3.13 |
| 8 | Structural members | O Encased in concreteO Not encased | IS:800;Section-10 |
| 9 | Proposed thickness Specified for corrosion materials | O General weld-ableO High strengthO Cold formedO Tubular | IS:2062IS:8500IS:801,811IS:806 |
| 10 | Minimum metal protection | O Hot rolled sectionsO Cold formed sectionsO Tubes | IS:800;CL.3.8CL.3.8.1 to CL.3.8.4CL.3.8.5CL.3.8.5 |
| 11 | Structural connections | O RivetsO CT BoltsO SHFG BoltsO Black Bolts | IS:800;Section-8IS:1929,2155,1149 |
[51]
| O Welding-filedShop (Specifywelding typeproposed)O Composite | IS : 6639, 1367IS : 3757, 4000IS : 1363, 1367IS : 816, 814,13957280, 3613,64196560, 813,9595 | ||
|---|---|---|---|
| 12 | Minimum fire ratingProposed with method | O Rating......hoursO Method proposed-- In tumescent painting- Spraying- Quilting- Fire retardant boarding | IS : 1641, 1642,1643 |
[52]
FORM I