Particulars to accompany application of re-erecting a building:- Every person who intends to erect or re-erect or alter a building shall give notice in writing to the Chairman of his intention in the form prescribed at Appendix 'A' with duplicate copy of Town Planning Department, Government of Manipur and such notice shall be accompanied by Plans and Statements in triplicate as required under Bye-law 5. The Plans may be ordinary prints on ferro paper. One set of such Plans shall be retained in the office of the Chairman for record after the issue of the permit or a refusal. One copy of such plan shall be retained in the office of Town Planning Department.
-
Every government department, as far as possible shall comply with all the provisions of these bye-laws. They shall also notify with plans, their intention, to the Chairman but may not wait for the permit for starting the work. Where objections have been pointed out by the Board, it shall be obligatory for the department to take necessary action to obviate the objections as laid down in the Government Building Act, 189 (4 of 1899).
-
Plans accompanying Notice:- The following shall accompany the notice:-
(1) Site plan—The site plans sent with an application for permit shall be drawn to a scale of not less than 8 m to 1 cm (or 64 ft, to 1 in) and shall show:
(a) the boundaries of the side and of any contiguous land belonging to the owner thereof;
(b) the position of the site relating to neighbouring streets;
(c) the name of the street in which the building is proposed to the situated;
[7]
(d) all existing building standing on the site;
(c) the position of the building and of all other buildings, if any, which the applicant intends to erect upon his contiguous land referred to in (a) in relation to;
(i) the boundaries of the site, and in case where the site has been partitioned the boundaries of the portion owned by the applicant and also of the portion owned by the other owners;
(ii) all adjacent streets, buildings and premises within a distance of 12 m (or 40ft.) of the site and of the contiguous land, if any referred to in (a); and
(iii) if there is no street within a distance of 12 m. (or 40 ft) of the site, the nearest existing street;
(f) the means of acces from the street to the building and to all other buildings, if any, which the applicant intends to erect upon his contiguous land referred to in (a);
(g) the position and the number of storeys of all other buildings within 12 m.(or 40 ft.) of the site.
(h) the position, forms and dimensions of kitchens, staircases, privies, urinals, drains, cesspools, stables, cattle sheds, cow-houses, wells and other appurtenances of the buildings;
(i) free passage or way in front of the building;
(j) space to be left about the building to secure a free circulation of air, admission of light and access for scavenging purposes;
(k) the width of the street, if any, in front of the building, if any, at the side or rear of the building; and
(1) such other particulars as may be prescribed by the Road;
(m) north point; and
(n) the wiidth of front, side and rear yard, existing road side trees, lamp and Telephone posts.
(2) Building plans:- The plans of the building and elevations and sections accompanying the notice shall be accurately drawn to a scale of 1m to 1cm (or 8 ft. to 1 in) and coloured. Adequate arrangement for proper drainage shall also be indicated. The plans shall include;
(a) floor plans of all floors together with the covered area, access to buildings and
[8]
basement plan. Such drawing shall clearly indicate the sizes and spacing of all supporting members, sizes of room. Sizes of windows, ventilators, door openings and stair rooms;
(b) exact location of essential services e.g. WC, sink, bath and the like;
(c) sectional drawing showing clearly the sizes of footing, thickness of basement walls and all roof slabs and floor slabs, wall construction, sizes and spacing of framing members, ceiling heights and parapet heights with their materials. The section should indicate the drainage and slope of the roof. At least one section should be taken through the staircase,
(d) all street elevation
(e) details of served privy, if any;
(f) dimensions of the projected portions beyond the permissible building line;
(g) terrace plan indicating the drainage and the slope of the roof; and
(h) indication of the north line;
(i) The plans of the building and elevations and sections accompanying the notice shall be accurately drawn to scale of 1 m. to 1 cm. (or 8ft. to 1 inch) and coloured showing different types of works. Adequate arrangement for proper drainage shall also be indicated.
(j) building plans for bamboo houses, huts and sheds may have no sections and elevations.
(3) Private Water supply and Sewage Disposal System—Plan and sections of Private water supply and sewage disposal system, if any, shall also be included,
(4) Every person who intends to erect, re-erect or make material/structural alteration shall obtain building permit by giving an application in writing to the Council in the prescribed form given in Form I to VI duly signed by the "Licensed Architect/Engineer/Town Planner etc.
(5) Specifications:- Specifications, both general and detailed, giving kind and grade of materials to be used, duly signed by the registered architect/engineer, shall accompany the notice.
(6) Building Plans for Lifeline and Special Buildings:- The following additional information shall be furnished/indicated in the building plans in addition to the item specified 5(1), 5(2) and 5(3):
i. Access to fire appliances/vehicles with details of vehicular turning circle/and
197
clear motorable access way round the building.
ii. Size (width) of main and alternate staircase along with balcony approach, corridor ventilated lobby approach;
iii. Location and details of lift enclosure;
iv. Location and size of fire lift;
v. Smoke stop lobby/door where provided;
vi. Refuse chutes; refuse chamber, services duct, etc.
vii. vehicular parking spaces
viii. Refuge area if any;
ix. Details of building service-air conditioning system with position of dambers, mechanical ventilation system, electrical services, boilers, gas pipes etc.
x. Details of exits including provision of ramps etc. for hospitals and special risks.
xi. Location of generator, transformer and switchgear room;
xii. Smoke exhauster system if any;
xiii. Details of fire alarm system network;
xiv. Location of centralized control, connecting all fire alarm system, built in fire protection arrangements and public address system etc.
xv. Location and dimension of static water storage tank and pump room;
xvi. Location and details of fixed fire protection installations such as sprinklers, wet risers, hose reels, derenchers, co 2 installation etc. and
xvii. The proper signs/symbols and abbreviation of all fire fighting systems shall be
xviii. Service Plants: The services plans shall include all details of building and plumbing services, and also plans, elevations and sections of private water supply, sewage disposal system and rainwater harvesting system, if any (Part 8 'building Services' and Part 9 'Plumbing Services' of the National Building Code).
xix. Specifications: Specifications, both general and detailed, giving type and grade of materials to be used, duly signed by the registered architect, structural engineer shall accompany the plans.
[10]
xx. Structural Sufficiency Certificate: The plans shall be accompanied by structural sufficiency certificate signed by the structural engineer and the owner jointly to the effect that the building is safe against various loads, forces and effects the building is safe against various loads, forces and effects including due to natural disasters, such as, earthquake, landslides cyclones, floods, etc. stipulated under chapter VII of this Bye-law, Part 6 'Structural Design' of the National Building Code and other relevant Codes in Form IV. The structural engineer shall also have the details to substantiate his design.
- Deviations during construction:-(i) If during the construction of a buildings any deviation of a substantial nature from the sanctioned plan is intended to be made, sanction of the Council shall be obtained before the change is made.
(ii) The Council may arrange from time to time, during the course of construction of a building for such inspection as the council may consider necessary.
- Fees—
(1) No notice as referred to above in bye-law 3 shall be deemed valid unless and until the person giving notice has paid the fees given below to the Council and an attested copy of the receipt of such payment is attached with the notice:
| For R.C.C., masonry & brickworks: | ||
| 1. | Cost of the application Form (Form I-VI) | Rs. 100/- per set |
| 2. | Buildings of plinth area upto 200 square | Rs. 100/- per square metre |
| 3. | Building of plinth area from 200 square metre and above | Rs. 120/- per square metre |
| 4. | For additional storey above Ground +1 | Rs. 100/- per square metre |
| 5. | Application Fees for Cinema, Theatre, multiplex, Hotels with Conference Halls in addition to the normal fees | Rs. 10,000/- in addition to normal fees at Sl. 1 to 3. |
| Loadbearing buildings | ||
| 1. | The plinth area upto 200 square metre | Rs. 50/- per square metre |
| 2. | The plinth area from 200 square metre and above | Rs. 100/- per square metre |
| Revalidation of already approved Building Plans | ||
| 1. | Revalidation of Plans | Rs. 1,000/- per Annum |
| Installation of Communication Towers | ||
| 1. | Fee for installation of Towers | Rs. 1,00,000/- per unit |
| 2. | For every Service Provider in case of sharing in addition to fee for installation of Towers. | Rs. 50,000/- per unit |
| 3. | Renewal fee for every service provider | Rs. 50,000/- per unit |
| Opening of ATM booths | ||
| 1. | Application fee for one booth | Rs. 10,000/- |
| Application for a Filling Station | ||
| Application fee for a filling station | Rs. 40,000/- | |