65 Applicability :
These byelaws are applicable to all private and public buildings (proposed and existing) used by the public and shall not be restricted to a single floor or storey but shall allow free & full accessibility to the entire building.
[27]
66 Definitions :
a) Non-Ambulatory Disabilities: Impairment that regardless of cause or manifestation, for all practical purpose, confines individuals to wheelchairs.
b) Semi-Ambulatory Disabilities: Impairments that cause individual with difficulty or insecurity, individuals using braces or crutches, arthritis, and those with pulmonary and cardiac ills may be semi-ambulatory.
c) Hearing Disabilities : Deafness or hearing handicaps that might make individual insecure in public area because he is unable to communicate or hear warning signals.
d) Sight disabilities : Total blindness or impairments affecting sight to the extent that the individuals functioning in public areas in insecure or exposed to danger.
e) Wheel Chair : Chair used by disable people for mobility. The standard size of the wheel chair shall be taken as 1050mm x 750mm.
67 Guiding/Warning Floor Materials :
The floor materials to guide or warn the visually impaired persons with a change of colour or material with different texture and easily distinguishable from the rest of the surrounding floor materials is called guiding warning floor materials. The materials with different texture give audible signals with sensory warning when a person moves on this surface with walking stick, it is meant to give the directional effect or warn a peron when at critical places.
68 Visual Signage :
Appropriate identification of specific facilities within a building for the persons with disabilities should be done with proper signage. Visually impaired persons make use of other senses such as hearing and touch to compensate for the lack of vision, whereas visual signals benefit those with hearing disabilities.
Signs should be designed and located so that they are easily readable by using suitable letter size (not less than 20 mm) high. For visually impaired persons, information board in Braille on the wall at a suitable height and it should be possible to approach them closely. To ensure safe walking there should not be any protruding sign which creates construction in walking. Public address system may also be provided in busy public areas. The symbols/information/should be in contrasting colour and properly illuminated because people with limited vision may be able to differentiate amongst primary colours.
69 Site Planning :
To accommodate the persons with disabilities and elderly people each building and its site should be planned and designed as an integral unit from the very beginning of the design proces.
a) Walks and Paths :
Walking should be smooth, hard level surface suitable for walking and wheeling. The minimum walkway width should be 1200 mm. And for moderate two ways traffic should be 1650 mm -1800 mm. Longitudinal walk gradient should be 3 to 5% (30mm to 0.50 mm in meter). When walk exceed 60 meter in length it is desirable to provide rest area adjacent to walk at convenient
[28]
intervals with space for bench seats. For comfort the seat should be between 350 mm to 425 heights but not over 450 mm. Texture change in walkways adjacent to sitting will be desirable for blind persons.
b) Parking : For parking of vehicles the following provisions shall be made :
i. Surface parking for two car spaces shall be provided near entrance for the persons with disabilities with maximum travel distance of 30 m from building entrance.
ii. The width of parking shall be a minimum of 3.60 m
iii. The information stating that the space is reserved for wheel chair users shall be conspicuously displayed.
iv. Guiding floor materials shall be provided for a device, which guides visually impaired persons with audible signals, or other devices, which served the same purpose, shall be provided.
c) Building requirements :
The specified facilities for the building for persons with disabilities shall be as follows :
a. Approach to plinth level: Every building should have at least one entrance accessible to the disabled and shall be indicated by proper signage. This entrance shall be approached through a ramp together with the stepped entry.
b. Ramped Approached : Shall be finished with non-slip materials. Minimum width of ramp shall be 1000 mm with maximum gradient 1:12 length of ramp shall not exceed 9.0 m having 800 mm. high handrails on both sides.
c. Exist/Entrance Door : Minimum clear opening of the entrance door shall be 900 mm.
d. Entrance Landing : Entrance landing shall be provided adjacent to ramp with a minimum dimension of 1800 mm x 2000 mm. finishes shall have a non-slip surface with a texture traversable by a wheel chair.
e. Corridor connecting the entrance/exit for the handicapped : The corridor shall be provided as follows :
i. "Guiding floor materials' shall be provided for device than emit sound to guide visually impaired persons.
ii. The minimum width shall be 1500 mm.
iii. in case of level difference, slope ways shall be provided with a slope of 1.2.
f. Handrails shall be provided for ramps/slope ways.
g. Stairways : One of the stairways near the entrance/exit for the disabled shall have the following provisions :