61 Rain Water Harvesting :
a) Water Harvesting : Water harvesting through storing of water runoff including rainwater in all existing and new buildings on pilots of 100 square metre and above will be mandaroty. The plans submitted shall indicate the system of storm water drainage along with points of collection of rain water in surface reservoirs or in rechazrge wells.
b) Soft Cover : Provision for soft cover should be included in the plan for building sites :
i. For any building having a minimum covered area of 500 square metre, the applicant should provide soft cover of at least 15% of the plot area.
ii. For any other building, having lesser covered area, the soft cover should be at least 10% of the plot area.
62 Recycling of waste water :
All buildings having a covered area of 500 Sq.mts or minimum discharge of 10,000 litre and above per day shall incorporate waste water recycling system. The recycled water should be used for non drinking purposes.
63 Incentive for rainwater harvesting/Recycling of Waste water :
The incentives in terms of rebate of 10% on building permission fees will be given by the Council for owners or their successors-in-interest who undertake both recycling of waste water and rain water harvesting structures.
64 Energy Conservation Building :
Building or building complexes having a connected load of 100 KW will be regulated as per the Energy Conservation Code 2007 as amended. Generally buildings or complexes having air conditioned area of 1,000 sq.m. or more will also fail under this category.