- (1) Structural Design:- For any building construction work under the jurisdiction of these bye-laws, structural design/retrofitting shall only be carried out by a structural Engineer on Record (SER) or Structural Design Agency on Record (SDAR). Proof checking of various design/reports shall be carried out by the Council as per Table-VI wherever applicable.
Generally, the structural design of foundations, elements of mansory, timber, plain concrete, reinforced concrete, pre-stressed concrete and structural steel shall conform to the provision of part VI Structural Design Section-1 loads, Section-2 foundation, Section-3 wood, Section-4 masonry, Section-5 concrete & Section-6 Steel of National Building Code of India (NBC), taking into consideration the Indian Standards as given below.
(2) For General Structural Safety:
(a) IS 456-2000" Code of Practice for plain and reinforced concrete
(b) IS 800-1984" Code of Practice for general construction in steel
(c) IS 801-2975" Code of Practice for use of Cold formal Light Gauge Steel Structural Members in General Building Construction
(d) IS 875 (Part 2): 1987 Design Loads (other than earthquake) for buildings and structures part 2 Imposed Loads
(e) IS 875 (Part 3): 1987 Design Loads (other than eatrthquake) for buildings and structures part 3 Wind Loads
(f) IS 875 Part 4): 1987 Design Loads (other than earthquake) for buildings and structures part 4 Snow Loads
[24]
(g) IS 875 (Part 5): 1987 Design Loads (other than earthquake) for buildings and structures part 5 special laods and load combination
(h) IS 883-1966" Code of Practie for Design Structural Timber in Building
(i) IS 1904-1987" Code of Practice for Structural Safety of Buildings : foundation"
(j) IS 1905-1987" Code of Practice for Structural Safety of Buildings : Masonry walls
(k) IS 2911 (Part I): Section 1: 1979" Code of Practice for Design and Construction of Plie foundation Section 1
Part 1 : Section 2 Based Cast-in-situ piles
Part 1 : Sectuin 3 Driven pre-cast concrete Piles
Part 1 : Section 4 Based Pre-cast Concrete Piles
Part 2 : Timber Piles
Part 3 : Under Reamed Piles
Part 4 : Load Test on Piles
(3) For Cyclone/Wind Storm Protection :
a) IS : 875 (3)-1987 :code of Practice for Design Loads (other than earthquake) for Buildings and Structures, Part 3, Wind Loads”
b) Guidelines (Based on IS 875 (3) 1987) for improving the Cyclonic Resistance of Low rise houses and other building
(4) For Earthquake Protection :
a) IS : 1893-2002 “criteria for Earthquake Resistant Design of Structures (Fifth Revision)
b) IS : 13920-1993 “Ductile Detailing of Reinforced Concrete Structures subjected to Seismic forces-Code of Practice”
c) IS : 4326-1993 “Earthquake Resistant Design and Construction of Buildings - code of practice (Second Revision)”
d) IS : 13828-1993 “Improving Earthquake Resistant of Low Strength Masonry Buildings-Guidelines”
e) IS : 13827-1993 “Improving Earthquake Resistant of Earthen Buildings-Guidelines”
f) IS : 13935-1993 “Repair and Seismic Strengthening of Buildings-Guidelines”
(5) For Protection of Landslide Hazard :
a. IS : 14458 (Part 1) : 1998 Guidelines for retaining wall for hill area : Part 1 Selection of type wall.
b. IS : 14458 (part 2) ; 1997 Guidelines for retaining wall for hill area; Part 2 Design of retaining/breast wall.
c. IS: 14458 (Part 3):1998 Guidelines for retaining wall for hill area: Part 3 construction of dry stone walls
d. IS : 14496 (Part 2); 1998 guidelines for preparation of landslide-hazard zonation
e. maps in mountains terrains; Part 2 Macro-zonation.
Note : Whenever an Indian Standard including those referred in the National Building Code or the Indian National Building Code is referred; the latest revision of the same shall be followed except specific criteria, if any, mentioned above against that code.
56 Structural Design Basis Report :
In compliance of the design with the above Indian Standard, the Structural Engineer on Record will submit a structural design basis report in the format given in appendix-B convering the essential safety requirements specified in the Standard.
[25]
57 Review of Structural Design :
a) The Council shall create a Structural Design Review Panel (SDRP) consisting of Senior Structural Design Engineers on Record and Structural Design Agencies on Record, whose task will be to review and certify the design prepared by Structural Engineer on Record or Structural Design Agency on Record whenever referred by the competent authority
b) The Reviewing Agency shall submit addendum to the certificate or a new certificate in case of subsequent changes in structural design.
c) Table below gives requirements of SDRP for structures of different complexities.
PROOF CHECKING REQUIREMENTS FOR STRUCTURAL DESIGN
| No. | TYPE OF STRUCTURE | SUBMISSION FROM SER OR SDAR | TO BE PROOF CHECKED |
| 1 | Highrise building, buildings above 1000 square metre plinth area and more than Ground+2 and above | Structural Design Basis Report | To be checked |
| Preliminary design | To be checked | ||
| Structural design/drawings | To be checked | ||
| 2 | Public buildings with more than 1000 square metre plinth area and more than Ground+2 and above | Structural Design Basis Report | To be checked |
| Preliminary design | To be checked | ||
| Structural design/drawings | To be checked | ||
| 3 | Lifeline & Special buildings and Special Structures | Structural Design Basis Report | To be checked |
| Peliminary design | To be checked | ||
| Structural design/drawings | To be checked |
Notes :
* Public buildings means assembly of large number of people including schools, hospitals, courts etc.
* Special structure means large span structures such as a stadium, assembly halls or tall structures such as water tanks, TV tower, chimney, etc. and the requirement of third party verification will depend on the type of structure.
58 Supervision :
All construction including load bearing buildings upto 3 storeys shall be carried out under supervision of the Construction Engineer on Record (CER) or Construction management Agency on Record.
59 Building Service :
The planning, design and installation of lifts and escalators shall be carried out in accordance of Part VIII Building Services, Section 2 Electrical Installations, Section 3 Air Conditioning & Heating, Section V Installation of Lifts & Escalators of National Building Code of India, 2005.
60 Fire Safety Detection and Distinguishing System :
a) The Council while according permission shall follow the Code of Practice and Standards of Requirement recommended in the national Building Code of India.
[26]
b) Fire protection and extinguishing system shall conform the accepted standards and shall be installed as recommended in the National Building Code of India and to the satisfaction of Directorate of Fire Service.